• 제목/요약/키워드: separation of Hg(II)

검색결과 11건 처리시간 0.023초

액체 크로마토그래피에서 Poly-NTOE(1, 12-diaza-3, 4:9, 10-dibenzo-5, 8-dioxacyclopentadeca-1, 12-ylene-2, 7-dihydroxyoctamethylene)를 이용한 Hg(II)의 분리 (Separation of Hg(II) by using the poly-NTOE(1, 12-diaza-3, 4:9, 10-dibenzo-5, 8-dioxacyclopentadeca-1, 12-ylene-2, 7-dihydroxyoctamethylene) in Liquid Chromatography)

  • 김해중;신영국;김시중
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.259-264
    • /
    • 1995
  • 수용액서 poly-NTOE(1, 12-diaza-3, 4:9, 10-dibenzo-5, 8-dioxacyclopentadeca-1, 12-ylene-2, 7-dihydroxyoctamethylene)를 흡착시킨 실리카겔을 고정상으로 하는 액체 크로마토그래피를 이용하여 혼합 금속이온용액으로부터 전이금속 및 후전이금속이온들의 분리효율을 결정하였다. pcly-NTOE와 금속이온들간의 결합상수 및 분리인자들의 순위는 전이금속이온의 경우 Co(II)Zn(II)였으며, 후전이금속이온들의 경우 Cd(II)

  • PDF

DBHQ-OPP foam에 의한 Hg(II)의 흡착과 분리 (On the Separation and Adsorption of Hg(II) by DBHQ-OPP Foam)

  • 성창근;문영자;김찬조
    • 농업과학연구
    • /
    • 제10권2호
    • /
    • pp.345-353
    • /
    • 1983
  • 수용액에 존재하는 중금속이온중의 Hg(II)을 정량적으로 분리 회수하기 위하여 DBHQ(5. 7-dibromo-8-hydroxyquinoline)을 Open-pore polyurethane foam (OPP foam)에 침윤시켜 수지의 응용성을 연구하였다. Hg(II)의 흡착은 DBHQ와 1:2 몰비의 착물형성이 이루어지며 Hg(II)의 흡착과 분리는 Batch법으로 실험하여 최적조건을 결정하였다. 가장 양호한 흡착은 DBHQ의 등전점인 pH5.0 부근에서 그리고 분리하는데는 4M-HCl, 50% 아세톤 용매를 사용하였을 경우가 비교적 정량적인 흡착과 분리가 이루어지는 조건이었으며 이와같은 결과를 기초로 DBHQ-OPP foam에 대한 Hg(II)의 흡착 및 분리에 대한 반응메카니즘을 제안했다.

  • PDF

공침-부선기술에 의한 수용액 시료 중 흔적량 수은 [Hg(II)]의 분리 및 농축 (Separation and Concentration of Trace Mercury [Hg(II)] in Water Sample by Coprecipitation Flotation Technique)

  • 이강석;최희선;김선태;김영상
    • 대한화학회지
    • /
    • 제35권4호
    • /
    • pp.355-361
    • /
    • 1991
  • 수용액 시료 중 흔적량 수은[Hg(II)]을 공침-부선기술에 의하여 분리-농축하는 방법에 관하여 연구하였다. 물시료 1000ml에 0.1M Ce$^{3+}$ 용액 3.0 ml를 가하고, 1.0M NaOH 용액으로 pH를 11.0으로 되게 조절하여 Hg(II)를 Ce(OH)$_3$와 함께 공침시켰다. 0.1${\%}$ sodium oleate 용액 2.0 ml를 가하여 만든 소수성 침전을 질소기체로 bubbling하여 용액 표면으로 띄웠다. 뜬 침전을 감압 플라스크에 모으고 2.0M HNO$_3$ 5.0 ml 로 녹였다. 탈이온수로 용액을 묽혀 25.00 ml로 정확히 만들었다. Hg(II)의 함량을 냉증기-원자흡수 분광법으로 정량하였다. 정량과정에서 Ag$^+$, Br$^-$, I$^- $ 등의 간섭은 관찰되지 않았다. 고려대학교 서창캠퍼스의 폐수에서 Hg(II)의 분석결과는 1.98 ng/ml 이었고, 이 값에 대한 상대표준편차는 3.6${\%}$이었다. 또 이 폐수에 1.0과 2.0ng/ml의 Hg(II)를 첨가하여 분석한 회수율은 각각 95와 91${\%}$이었다. 이런 결과로부터 본 분석법이 물시료 중 흔적량 Hg(II)의 정량에 꽤 정확하고 재현성이 있음을 확인할 수 있었다.

  • PDF

역상 액체 크로마토그래피에 의한 몇가지 금속 이온들의 Piperidinedithiocarbamate 킬레이트 동시분리분석 (Simultaneous Separation Analysis of Some Metal Ions in Piperidinedothiocarbamate Chelates by Reversed-Phase Liquid Chromatography)

  • 이원;방승훈;김미경
    • 분석과학
    • /
    • 제13권1호
    • /
    • pp.27-33
    • /
    • 2000
  • 역상 액체크로마토그래피를 이용하여 Ni(II), Pd(II), Co(II), Cu(II) 및 Hg(II) 이온과 peperidinedithiocarbamate (PDTC)가 형성하는 킬레이트들을 분리하고, 금속이온의 동시 정량을 시도하였다. Novapak $C_{18}$ 분리관에서 methanol/water 혼합용액을 용리액으로 사용하고 pH, 추출용매의 종류 및 이동상의 세기 등 분리도에 영향을 주는 몇 가지 인자들의 영향을 조사하였으며, 각 금속 PDTC 킬레이트의 용매세기인자 범위는 $0{\leq}log\;k^{\prime}{\leq}1$의 범위임을 확인하였다. 각 금속이온들의 검정곡선은 $0{\sim}1.2{\mu}g/mL$의 농도범위에서 직선관계가 잘 성립하는 것을 확인하였으며, 상대표준편차는 1.96~3.31% 범위로 재현성있는 결과를 얻었다. 최적 분리 조건에서 합성시료 중에 함유된 미량 금속이온들은 상대오차 ${\pm}2.0%$ 범위내에서 동시분리 정량이 가능하였다.

  • PDF

Preparation and Characterization of a Surface Renewable Solid State Hg/HgO Reference Electrode Utilizing Gold Amalgam

  • Kim, Won;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권3호
    • /
    • pp.439-442
    • /
    • 2007
  • A solid state Hg(Au)/HgO reference electrode was prepared utilizing gold amalgam solid particles. Solid fine powder of the gold amalgam was prepared by chemical reduction of Au(III) with NaBH4 followed by reduction of Hg(II) in the presence of gold fine particles. The solid content in the suspension of the gold amalgam particles and fine mercury oxide particles in DMF containing PVC was precipitated by the addition of a large amount of water to give solid Hg(Au)/HgO/PVC mixture. After drying, the mixture was pressure-molded to a physically stable Hg(Au)/HgO composite reference electrode material. The electrochemical characteristics of the electrode as a reference electrode were very similar to an ordinary Hg/HgO reference electrode. The electrode material can be molded and fabricated in any desired shape and size. The surface can be renewed by a simple polishing process whenever contaminated or deactivated. The applicability of the electrode in the electrochemical detection of carbohydrates after anion exchange separation was evaluated.

거대고리 운반체에 의한 중금속이온의 에멀죤 액체막 수송 (Emulsion Liquid Membrane Transport of Heavy Metal Sons by Macrocyclic Carriers)

  • 정오진
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.223-232
    • /
    • 1995
  • 액체막의 운반체로 사용할 새로운 2개의 거대고리화합물을 합성하였다. 이들 결과들은 이 시스템을 구성하는데 있어서 이론의 응용성을 증명하여 준다. source phase의 공존이온으로서 $SCN^-$,$I^-$$Cl^-$이온을 그리고 receicing phases에서 $S_2O_3^{2-}$$P_2O_7^{4-}$을 이용한 액세막계로서부터 중금속 이온들에 대한 선택적 수송효율을 검토하였다. source phase의 M(II)이 $Cd(SCN)_2$$(P[SCN^-]= 0.40M)$, $Hg(SCN)_2([SCN^-]=0.40M)$, Pd(CN)$([CN^-]= 0.40M)$일때 M(II)의 수송율은 최대값을 나타낸다. 각가의 경쟁 양이온에 대한 Cd(II)이나 Pd(II)은 source phase가 00.3M-$S_2O_3^{2-}$이나 0.3M-$P_2O_7^{4-}$ 일때 가장 잘 분리된다.이 연구의 결과에서, 이 액체막계에서 효과적인 거대고리-매질수송을 하기 위해서는 두개의 규칙이 반드시 필요하다. 첫째, tiluence중으로 $M^{n+}$이온이 효과적으로 추출되고, 즉 만일 $M^{n+}$ 거대고리화합물 상호작용에 대한 logK값과 $M^{n+}$-거대고리화합물($L_1$이나 $L_2$)의 상호작용에 대한 logK값의 비가 충분히 크다면 receiving phase와 toluene의 접촉면으로부터 쉽게 중금속이온($Cd^{2+}$,$Pb^{2+}$$Hg^{2+}$)들이 떨어져 나온다. $L_1$(3,5-benzo-10,13,18,21-tetraoxa-1,7-diazabicyclo(8,5,5)eicosnan)은 $Cd^{2+}$$Pb^{2+}$ 이온과 안정한 착물을 형성한다. 그리고 $L_1$은 수용액중에서 용해하기가 매우 어렵다. 그리고 $Cd^{2+}$$L_1$$Pb^{2+}$$L_1$착물은 $Cd^{2+}-{(S_2O_3)}_2^{2-}$$Pd^{2+}-P_2O_7^{4-}$착물보다 비교적 불안정하다. 다른 한편으로 $Hg^{2+}-L_1$착물의 안정도는 $Hg^2-{2+}-(S_2O_3)_2^{2-}$이나 $Pb^{2+}-P0_2O_7^{4-}$의 그것보다 그리고 $L_2$(5,8,15,18,23,26-hexaoxa-1,12-diazabicyclo(10,8,8)octacosan)의 tuluene에 대한 분배계수는 $L_1$의 그것보다 훨씬 작다. 따라서 $Hg^{2+}$-$L_1$이나 $M^{n+}$이나 $M^{n+}-L-2(M^{2+}=Cd^{2+}, Pb^{2+}$이나 $Hg^{2+})$의 안정도수상수가 매우 큼에도 불구하고 이들 양이온의 수송량은 매우 적다.

  • PDF

혼합용매에서의 양이온교환수지에 의한 전이원소의 분리와 분배계수 (Separation and Distribution Coefficients of Some Transition Metal Ions in Some Mixed Solvents)

  • 차기원;김시중;박기채
    • 대한화학회지
    • /
    • 제17권6호
    • /
    • pp.434-438
    • /
    • 1973
  • 메탄올, 에탄올, 이소프로판올, 아세톤 및 디메틸술폭사이드와 물과의 혼합용매에서 니켈(II), 카드뮴(II), 아연(II) 및 수은(II)의 분배계수(C)를 Rexyn 101(나트륨형) 이온교환수지와 0.2M 염화나트륨용리액을 써서 측정하였다. 금속이온의 logC 값은 혼합용매의 유전상수의 역수에 따라 직선적으로 감소하였다. 그리고 금속이온의 분배계수는 같은 유전상수를 가진 비양성자성 유기분자와의 혼합용매에서는 유기분자의 염기도가 증가할수록, 그리고 양성자성 유기분자와의 혼합용매에서는 유기분자의 크기가 작을수록 감소하였다. 측정된 분배계수값으로부터 착화제의 첨가없이 염화나트륨이 0.2M 인 40%메탄올 용리액과 70% 에탄올 용리액을 단계적으로 사용하여 금속 이온들을 정량적을 분리할 수 있음을 알았다.

  • PDF

Mercury recovery from aqueous solutions by polymer-enhanced ultrafiltration using a sulfate derivative of chitosan

  • Carreon, Jose;Saucedo, Imelda;Navarro, Ricardo;Maldonado, Maria;Guerra, Ricardo;Guibal, Eric
    • Membrane and Water Treatment
    • /
    • 제1권4호
    • /
    • pp.231-251
    • /
    • 2010
  • The sulfatation of chitosan, by reaction with chlorosulfonic acid under controlled conditions, allowed increasing the pH range of chitosan solubility. The biopolymer was characterized using FTIR and $^{13}C$-NMR spectroscopy, elemental analysis and titration analysis and it was tested for mercury recovery by polymer enhanced ultrafiltration (PEUF). In slightly alkaline conditions (i.e., pH 8) mercury recovery was possible and at saturation of the polymer the molar ratio $-NH_2$/Hg(II) tended to 2.6. Polymer recycling was possible changing the pH to 2 and the polymer was reused for 3 cycles maintaining high metal recovery. The presence of chloride ions influences metal speciation and affinity for the polymer and "playing" with metal speciation allowed using the PEUF process for mercury separation from cadmium; at pH 11 the formation of hydroxo-complexes of Hg(II) limits it retention. Cake formation reveals the predominant controlling step for permeation flux.

발아 옥수수 amylases의 정제 및 특성 (Partial Purification and Some Properties of Amylases from Germinating Corn(Zea mays L.))

  • Lee, Tae-Ho;Jung, Tae-Yung;Park, Mi-yeon
    • 한국식품영양과학회지
    • /
    • 제19권6호
    • /
    • pp.625-635
    • /
    • 1990
  • 발아중인 옥수수에서의 전분의 가수분해효소인 amylases의 종류를 규명하고자 황산 암모늄염석법, DEAE-Sephadex A-50을 이 용한 이온교환칼럼법과 Sephadex G-100 Gel filtration chromatography 방법으로 정제하였으며 전분가수분해 효소는 3개의 peak가 나타났으며, 이를 각각 모아서 정제한 결과 각각의 비활성은 70.47(units/mg), 62.98(units/mg), 80.39(units/mg)으로 저단백식품의 하나인 옥수수임에도 불구하고 높은 활성을 나타내었다. 이것은 발아중 가수분해되는 전분체내에 이 효소의 작용이 커졌음을 유리당의 양이 증가하였음으로 알 수 있었다. 또한 고속액체 크로마토그라피를 이용하여 분석한 결과 3종류의 amylases중에 amylases(I)은 $\alpha$-amytotetrose의 종류로 밝혀졌으며, amylase(II)와 (III)는 각각, 주로 maltotetrose의 단위로 가수분해하는 전분 분해 효소이나. 서로 생물학적 성격에서 약간씩의 차이를 보이므로 같은 종류는 아닐 것으로 사료되었다.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF