• 제목/요약/키워드: sensorless drive

Search Result 327, Processing Time 0.035 seconds

A Study of the ZCP Estimation Methods considering Discretization Error and High Speed BLDC Sensorless Drive (이산화 오차를 고려한 ZCP 추정방법과 고속 BLDC 센서리스 구동에 관한 연구)

  • Seo, Eunjeong;Sohn, Jeongwon;Sunwoo, Myoungho;Lee, Wootaik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.95-102
    • /
    • 2014
  • This paper presents zero crossing point(ZCP) estimation methods considering discretization error for a high speed brushless DC(BLDC) motor drive. The ZCP is estimated by detecting the change of back-EMF polarity for the BLDC sensorless drive, and the discretization error exist on the estimated ZCP. The discretization error of the ZCP is a cause of the delay of a commutation timing of current and increment of a current ripple factor. Besides a delay of a ZCP estimation brings on the limitation of a speed range for the BLDC sensorless drive. The compensation method based on the error analysis with probability theory for reducing the effects of the discretization error of the ZCP is proposed. Also a ZCP estimation method according to the Back-EMF patterns is proposed to widen the speed range for the BLDC sensorless drive. The proposed methods are verified by the experiment.

Sensorless Control Using the Back EMF of PM Generator for 2MW Variable Speed Wind Turbine (역기전력을 이용한 2MW급 가변속 풍력터빈용 영구자석 동기기의 센서리스 제어)

  • Im, Ji-Hoon;Oh, Sang-Geun;Song, Seung-Ho;Lee, Hyen-Young;Kwon, Oh-Jeong;Jang, Jeong-Ik;Lee, Kwon-Hee
    • Journal of Wind Energy
    • /
    • v.2 no.2
    • /
    • pp.54-60
    • /
    • 2011
  • A PMSG in variable speed wind turbine needs to know the position of rotor for vector control. Since the position sensor has the disadvantage in terms of cost, complexity of the system, a sensorless algorithm is needed. The sensorless strategy using the back EMF estimation is used for PMSG Wind Turbine. This algorithm is comparatively easy to implement than other strategies. This paper introduces the application of stable sensorless control for 2MW direct drive PMSG. In order to confirm the sensorless algorithm, the implementation is proceeded using 2MW direct drive PMSG from no-load condition to full-load condition. To drive 2MW PMSG artificially, 2MW PMSG connected PMSG through the mechanical coupling.

Sensorless control of a SPMSM for driving cooling fans (냉각 팬 구동을 위한 SPMSM의 센서리스 제어)

  • Kim, Sang-Hoon;Kim, Ji-Min
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.15-20
    • /
    • 2014
  • Recently, PMSMs(Permanent Magnet Synchronous Motors) have become increasingly popular in various high-performance motor drive applications. However, the high-performance drive of PMSMs needs a position sensor such as a resolver, which increases not only the price of the system but also reduces the system reliability. This paper is on the implementation of sensorless control of a SPMSM, which drives a fan for cooling in appliances. In this paper, the rotor position for high-performance drive of a SPMSM is derived from back electromotive force (EMF) information proportional to the rotor speed. Also, the initial rotor position information for start-up is estimated from a saturation phenomenon of inductance. The validity of the proposed sensorless drives was confirmed by the experiment on the SPMSM drive systems for cooling fans of refrigerators and laptop computers.

  • PDF

Speed Sensorless Vector Control for AC servo Motor Using Flux observer

  • Hong, Jeng-pyo;Kwon, Soon-Jae;Hong, Soon-Ill
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.185-191
    • /
    • 2004
  • This study describes the scheme of vector drive system without speed sensor for AC servo motor using theory of a flux observer and based on the field oriented vector control. The new method of speed estimation is presented from operate with the position and magnitude of the secondary flux which obtain from the voltage reference and detected current. As the estimated speed is settled by the flux and the machine-specific parameters. this method don't need to adjust the gain of the parameter. Based on the derived theory for vector control. the scheme for sensorless vector drive of AC servo motor is designed and realized. And the experiment verifies it passable to realize the sensorless vector drive based on a field-oriented type.

Fuzzy back-EMF Observer for Improving Performance of Sensorless brushless DC motor drive (BLDC 전동기용 센서리스 드라이브의 성능 향상을 위한 퍼지 역기전력 관측기)

  • Park, Byoung-Gun;Kim, Tae-Sung;Ryu, Ji-Su;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.220-223
    • /
    • 2005
  • In this paper, a novel sensorless brushless DC (BLDC) motor drive method using the fuzzy back-EMF observer is proposed to improve the performance of conventional sensorless drive methods. Most existing back-EMF sensing methods need additional circuit and have a low performance intransient state or low speed range. Therefore, this paper proposes the fuzzy back-EMF observer and an algorithm using this observer to estimate a speed and a position of the rotor. The robustness of the proposed algorithm is proved through the simulation compared with other sensorless drive methods.

  • PDF

A Study on Low-Cost Sensorless Drive of Brushless DC Motor for Compressor Using Random PWM

  • Shin, Duck-Shick;Kim, Dae-Kyong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.91-96
    • /
    • 2013
  • Recently, it is increased to apply sensorless drive for BLDC (Brushless DC) motor to household electrical appliances, especially in the refrigerators and air conditioners, to reduce the cost and the acoustic noise by the operation and to make their functions more comfortable for human beings. In this paper, low-cost sensorless drive for BLDC motor is implemented by random PWM (Pulse Width Modulation). The experimental results show that the electromagnetic noise was reduced and the sound quality was improved by BLDC motor sensorless random PWM Control.

A Study on Speed control Sensorless BLDC using AVR (AVR을 이용한 Sensorless BLDC의 속도제어에 관한 연구)

  • Won, Jin-Kuk;Mon, Ji-Woo;Kim, Byong-Kuk;Son, Dong-Hyuk;Lee, Byung-Jun;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1144-1145
    • /
    • 2007
  • This paper is investigated the sensorless drive for BLDC motor using microprocessor. Since the BLDC motor should be commutated according to a rotor position, the sensors are required to detect the position. But the sensors increase cost and volume, complicate the motor configuration, and do not operate properly in some operating environments such as high temperature conditions, so that the necessity of sensorless commutation algorithm is getting increased. This paper is proposed the method to drive BLDC motor without position-detecting sensor using Back EMF. Back EMF commutation method was implemented the sensorless drive system which could control the rotational speed and monitor the behavior of a motor.

  • PDF

A Fuzzy Back-EMF Observer for Sensorless Drive of BLDC Motor (브러시리스 전동기의 센서리스 구동을 위한 퍼지 역기전력 관측기)

  • Park, Byoung-Gun;Kim, Tae-Sung;Ryu, Ji-Su;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2007
  • In this paper, a novel sensorless drive for brushless DC (BLDC) motor using the fuzzy back-EMF observer is proposed to improve the performance of conventional sensorless drive methods. Existing sensorless drive methods of the BLDC motor have low performance at transients or low speed range and occasionally require additional circuits. To cope with these problems, the back-EMF of the BLDC motor must be precisely estimated by a fuzzy logic, which is suitable to estimate the back-EMF which has a trapezoidal shape. The proposed algorithm using fuzzy back-EMF observer can achieve robust control for the change of an external condition and continuously estimate position of the rotor at transients as well as at steady state. The superiority of the proposed algorithm is proved through the simulation compared with other sensorless drive methods.

A Sensorless Switched Reluctance Drive System Based on the Improved Simplified Flux Method

  • Li, Zhenguo;Song, Andong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.477-482
    • /
    • 2012
  • This paper describes a new rotor position sensorless control method for SRM drives based on an improved simplified flux linkage method. In the traditional simplified flux linkage method, every phases take turns conduction and current chopping control method is used. Every phases take turns conduction means turning on the incoming working phase while turning off the working phase. This conduction mode causes coupling between turn-on and turn-off angles, which goes against optimal efficiency or torque ripple minimization with sensorless speed control. In the improved simplified flux linkage method, turn-off angle is calculated by flux loop, the turn-on angle can be given arbitrarily and has no relations with the turn-off angle, and the current chopping control method is used. The speed and rotor position can be estimated then. Finally, a sensorless SRM speed control system and an experiment platform with DSP are built and validity of this method is confirmed.

Sensorless Drive of Brushless DC Motors Using an Unknown Input Observer (미지입력 관측기를 이용한 BLDC 전동기 센서리스 드라이브에 대한 연구)

  • Ryu, Ji-Su;Hyun, Dong-Seok;Kim, Tae-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.65-71
    • /
    • 2006
  • In this paper, a novel motor control method is proposed to improve the performance of sensorless drive of BLDC motors. In the terminal voltage sensing method, which is a great portion of sensorless control, a precise rotor position cannot be obtained when excessive input is applied to the drive during synchronous operation mode. Especially in the transient state, the response characteristic decreases. To cope with this problem, the unknown input (back-EMF) is modelled as the additional state of system in this paper. Taking into account the disturbance adopted by the back-EMF, the observer can be obtained by the augmented system equation. An algorithm to detect the back-EMF of the BLDC motor using the state observer is constructed. As a result, the novel sensorless drive of BLDC motors that can strictly estimate rotor position and speed is proposed.