• Title/Summary/Keyword: sensitivity experiment

Search Result 747, Processing Time 0.035 seconds

Deep Interpretable Learning for a Rapid Response System (긴급대응 시스템을 위한 심층 해석 가능 학습)

  • Nguyen, Trong-Nghia;Vo, Thanh-Hung;Kho, Bo-Gun;Lee, Guee-Sang;Yang, Hyung-Jeong;Kim, Soo-Hyung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.805-807
    • /
    • 2021
  • In-hospital cardiac arrest is a significant problem for medical systems. Although the traditional early warning systems have been widely applied, they still contain many drawbacks, such as the high false warning rate and low sensitivity. This paper proposed a strategy that involves a deep learning approach based on a novel interpretable deep tabular data learning architecture, named TabNet, for the Rapid Response System. This study has been processed and validated on a dataset collected from two hospitals of Chonnam National University, Korea, in over 10 years. The learning metrics used for the experiment are the area under the receiver operating characteristic curve score (AUROC) and the area under the precision-recall curve score (AUPRC). The experiment on a large real-time dataset shows that our method improves compared to other machine learning-based approaches.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

Status of squeezed vacuum experiment and introduction to EPR (한국천문연구원의 진공양자조임 광원 개발 및 EPR 실험 소개)

  • Kim, Chang-Hee;Lee, Sungho;Park, June Gyu;Kim, Yunjong;Jeong, Ueejeong;Je, Soonkyu;Seong, Hyeon Cheol;Han, Jeong-Yeol
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.37.2-37.2
    • /
    • 2021
  • One of the main limitations to the ground- based gravitational-wave (GW) detector sensitivity is quantum noise, which is induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be effective approach to mitigate the quantum noise in the interferometer detector and it is currently used in advanced detectors. However, the current frequency-independent squeezed vacuum cannot reduce quantum radiation pressure noise at low frequencies. A possible solution to reduce quantum noise in the broadband spectrum is the injection of frequency-dependent squeezed (FDS) vacuum. We will report the current status of squeezing experiment at KASI and introduce to the EPR (Einstein-Podolsky-Rosen) entangled state of light, which can realize FDS light without the need for an additional, external cavity.

  • PDF

Inhibitory Effect of Purple Corn 'Seakso 1' Husk and Cob Extracts on Lipid Accumulation in Oleic Acid- Induced Non-Alcoholic Fatty Liver Disease HepG2 Model (올레산 유도 비알코올성 지방간세포에서 자색옥수수 색소 1호 포엽과 속대 추출물의 지질 축적 억제 효과)

  • Lee, Ki Yeon;Kim, Tae hee;Kim, Jai Eun;Bae, Son wha;Park, A-Reum;Lee, Hyo Young;Choi, Sun jin;Park, Jong yeol;Kwon, Soon bae;Kim, Hee Yeon
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.93-101
    • /
    • 2020
  • Seakso 1, a maize hybrid, was developed in 2008 by Gangwon Agricultural Research and Extension Services in Korea and registered in 2011. It is single-cross hybrid, semi-flint, deep-purple variety of corn, variety of are yellow, while the husks and cobs are purple. Due to the sensitivity of Seakso 1 to excess moisture after seeding, water supply should be carefully managed, and it should be harvested at a suitable time to obtain the highest anthocyanin content. This study investigated the hepatoprotective effect of Saekso 1 corn husk and cob extracts (EHCS) in oleic acid-induced non-alcoholic fatty liver disease (NAFLD) in HepG2 cells. EHCS showed a high level of lipid accumulation inhibiting effect. EHCS also suppressed triglyceride accumulation and inhibited expression of lipid marker genes, such as sterol regulatory element binding protein-1c (SREBP-1c) and sterol regulatory element binding protein-1a (SREBP-1a). Analysis by western blot of the expression of p-AMPK, p-SREBP1, PPARα, and FAS proteins showed that the incidence of SREBP1 protein, a major factor involved in lipid metabolism in the liver, has decreased significantly after treatment with the extracts. Moreover, the protein-induced expression of FAS, a major enzyme involved in the biosynthetic pathways of fatty acids, was decreased significantly in all concentrations. These results suggest that EHCS is a potent agent for the treatment of NAFLD.

The Comparison of Effective of Stretching Exercise and Stabilizing Exercise for The Patients with Myofascial Pain Syndrome at The Shoulder Girdle (견관절부 근막동통증후군의 근육내 전기자극치료시 신장운동과 안정화운동의 효과 비교)

  • Kim, Sang-Eun;Lee, Hyun-Ok;Kim, Jong-Soon;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.49-61
    • /
    • 2005
  • Summary of Background Data: Myofascial pain syndrome (MPS) is a common painful muscle disorder caused by trigger points occurring in myofascial. MPS is a major cause of chronical pain and is the subject of further clinical examination. Purpose: To uncover effective intramuscular stimulation therapy (IMS), the patients' actively participation stretching exercise and stabilizing around shoulder girdle where trigger point provoking myofascial pain syndrome in usually occurred. Methods: 45 myofascial pain syndrome patients were randomly chosen and divided into 3 groups. The first group (G1) received only IMS therapy, The second group (G2) had both IMS and active stretching exercises administered and the final group (G3) was given IMS therapy and stabilizing exercises. Therapy intervention was given for 3 weeks, 3 times a week and then only stretching exercise for the second group and stabilizing exercise for the third group was given for another 3 weeks. The visual analogue scale was dine before the experiment, 3 weeks after the experiment and 6weeks after the experiment to measure subjective degrees of pain and pressure pain threshold to measure sensitivity improvement of trigger point and functional ability questionnaire to measure daily life performance. Results: There were no significant changes after 3 weeks but after 6 weeks, between GI and G2 and between G1 and G3 showed significant change of pain, pressure pain threshold and daily life performance. There were significant improvement of the measurement of degrees of pain, pressure pain threshold and improvement of daily life performance at different times for G1 showed change 3 weeks after the experiment, but there were no changes 6 weeks after the experiment. There were significant improvement of the measurement at different times for G2 and G3 showed change 3 weeks after the experiment and 6 weeks after the experiment. Conclusions: IMS therapy proved to be effective in inactivation of trigger points of the myofascial pain syndrome patients and stretching and stabilizing exercises beside it keep remedial value longer by improvement of pain and dysfunction that occurred by the trigger point.

  • PDF

Discrimination of geographical origin for soybeans using ED-XRF (ED-XRF (Energy Dispersive X-ray Fluorescence spectrometer)를 이용한 콩 원산지 판별)

  • Lee, Ji-Hye;Kang, Dong-Jin;Jang, Eun-Hee;Hur, Suel-Hye;Shin, Byeung-Kon;Han, Guk-Tak;Lee, Seong-Hun
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.125-129
    • /
    • 2020
  • In this study we developed a method for determining the geographic origin of soybeans by combining energy dispersive X-ray fluorescence spectrometry with statistical analysis. In 2018, 197 soybean samples (100 Korean domestic samples and 97 foreign samples) were collected for the construction of a geographic origin model. The mineral concentrations of 26 elements were measured and determined via the fundamental parameters approach. One-way analysis of variance, t-test, and canonical discriminant analysis were employed to reveal five elements (P, Ni, Br, Zn, and Mn) that could be used for the determination of geographic origins. The sensitivity, specificity, and efficiency for the above method were 91.0, 95.9, and 93.4%, respectively. Validation results from 60 samples collected in 2019 showed a predictive rate of 93.3% for Korean domestic soybeans and 100.0% for foreign soybeans. In conclusion, the combination of energy dispersive X-ray fluorescence spectrometry and chemometrics could be used to effectively determine the geographic origin of soybeans.

A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling (3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램)

  • Perez, Marlon;Hernandez, Daniel;Michel, Eric;Cho, Min Hyoung;Lee, Soo Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.107-119
    • /
    • 2014
  • Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visual comparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a $C^{{+}{+}}$- and MATLAB-based software tool called Phased Array Coil Evaluator (PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results, and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil position coordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. After making the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform has been made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulation and experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiled gradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTD simulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivities element-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodic maintenance of phased array coils in a more accurate and consistent manner.

Response of Systemic Fungicides of Rhizoctonia spp. Causing Rhizoctonia Blight on Turfgrass (잔디에 Rhizoctonia 마름병을 유발하는 Rhizoctonia spp.의 침투성 살균제에 대한 반응)

  • Chang, Taehyun;Lee, Seong Jun
    • Weed & Turfgrass Science
    • /
    • v.2 no.4
    • /
    • pp.387-394
    • /
    • 2013
  • The Rhizoctonia blight causing by Rhizoctonia spp. is an important disease of turfgrass, requiring fungicide application to maintain acceptable conditions for turfgrass good qualities in the golf course. The experiment was conducted to determine the mean 50% effective concentration inhibiting mycelial growth ($EC_{50}$) value of to flutolanil, pyraclostrobine and hexaconazole to Rhizoctonia solani AG-1 IB, Rhizoctonia cerealis and Rhizoctonia solani AG2-2IV isolated from Gyeongbuk province of Korea in vitro. Five discriminatory concentrations of each fungicide were used to detect in vitro sensitivity. The mean of $EC_{50}$ values to three systemic fungicides was the lowest isolate of R. solani AG-1 IB. However, the sensitivity of fungicides to Rhizoctonia solani AG2-2IV were higher mean $EC_{50}$ value of 0.026 ${\mu}g\;a.i.\;ml^{-1}$ of pyraclostrobine and 0.044 ${\mu}g\;a.i.\;ml^{-1}$ of flutolanil. R. cerealis was the lowest sensitivity to hexaconazole which was an average $EC_{50}$ value of 0.022 ${\mu}g\;a.i.\;ml^{-1}$. Inhibition of mycelial growth rate (%) by three combine fungicides using the $EC_{50}$ value of each fungicide was the highest R. solani AG2-2IV. Results of this study were may confirmed in vitro response fungicide of three Rhizoctonia species for control of Rhizoctonia blight in the field.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF