• 제목/요약/키워드: sensitive detection

검색결과 1,726건 처리시간 0.026초

Easy Detection of Amyloid β-Protein Using Photo-Sensitive Field Effect

  • Kim, Kwan-Soo;Ju, Jong-Il;Song, Ki-Bong
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.339-344
    • /
    • 2012
  • This article describes a novel method for the detection of amyloid-${\beta}$($A{\beta}$) peptide that utilizes a photo-sensitive field-effect transistor (p-FET). According to a recent study, $A{\beta}$ protein has been known to play a central role in the pathogenesis of Alzheimer's disease (AD). Accordingly, we investigated the variation of photo current generated from p-FET with and without intracellular magnetic beads conjugated with $A{\beta}$ peptides, which are placed on the p-FET sensing areas. The decrease of photo current was observed due to the presence of the magnetic beads on the channel region. Moreover, a similar characteristic was shown when the Raw 264 cells take in magnetic beads treated with $A{\beta}$ peptide. This means that it is possible to simply detect a certain protein using magnetic beads and a p-FET device. Therefore, in this paper, we suggest that our method could detect tiny amounts of $A{\beta}$ for early diagnosis of AD using the p-FET devices.

자기진단 CPGFRP의 파괴예측기능 평가를 위한 콘크리트 적용실험 (Evaluation of Fracture Detection Function for the Concrete by Self-Diagnosis CPGFRP)

  • 최현수;박진섭;정민수;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.27-31
    • /
    • 2003
  • To maintain serviceability of concrete structure more than proper it is necessary not only predict service life through periodical monitor but also need monitoring system to recognize optimal time and method for repair. Recently, CPGFRP, replacing some GFRP with CF, is developed and used for monitoring concrete fraction. But dramatic resistance change of CPGFRP is showed below 0.5% strain and it is not small strain in terms of monitoring micro crack in concrete. In other word, monitoring with CF is not suitable in low stress but hight stress. In this study, we accessed applicable possibility and reliability of CPGFRP composite as monitoring sense that is proved very sensitive to stress through domestic and oversea previous study. CPGFRP composite plays a role in specimen like steel and increases flexural strength. CPGFRP composite shows resistance increasement in micro crack. In particular, CPGFRP is more sensitive than strangage in low stress. Resistance change ratio curve is very similar to strain curve so sensitivity and reliability is very excellent to monitor concrete fracture.

  • PDF

14N Mines Pulsed-ENDOR of Proximal Histidine and Heme of Aquometmyoglobin and Fluormetmyoglobin

  • Lee, Hong-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권12호
    • /
    • pp.1769-1772
    • /
    • 2002
  • Previous $^{19}F\;and\;^{1,2}H$ electron-nuclear double resonance (ENDOR) study of fluorometmyoglobin (MbF) in frozen-solution state provided sensitive tools sensing subtle structural changes of the heme that are not obtainable from X-ray. [Fann et al., J. Am. Chem. Soc. 1995, 117, 6019] Because of the intrinsic inhomogeneouse EPR line broadening effect of MbF in frozen-solution state, detection of the intrinsic inhomogeneouse EPR line broadening effect of MbF in frozen-solution state, detection of the electronic and geometrical changes of the heme ring itself and the proximal histidine by using $^{14}N$ CW ENDOR was interfered. In the present study, hyperfine-sensitive $^{14}N$ Mims ENDOR technique of pulsed-EPR was employed to probe the changes. With two different $\tau$ values of 128 and 196 ns, $^{14}N$ ENDOR signals of the heme and proximal histidine were completely resolved at $g'_{II}(=g_e=2)$. This study present that X-band $^{14}N$ Mims ENDOR sequence can sensitively detect the small changes of the spin densities and p orbital populations of the proximal and the heme nitrogens, caused by ligand and pH variation of the distal site.

A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection

  • Alam, Seikh Mafiz;Jeon, Chi-Wan;Karim, Mohammad Mainul;Lee, Sang-Hak;Wabaidur, Saikh Mohammad;Suh, Yeoun-Suk;Chung, Hye-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.102-106
    • /
    • 2009
  • A rapid and sensitive chemiluminescence (CL) method using flow-injection (FI) has been developed for the determination of mandelic acid which is based on the enhancement of mandelic acid to the CL intensity of ${Ru(bipy)_{3}}^{2+}$-Ce(IV) system. The enhancement effect was dependent on the concentration of mandelic acid, based on which, CL system was established for the determination of mandelic acid. The concentrations of ${Ru(bipy)_{3}}^{2+}$+, Ce(IV), and $H_2SO_4$ were optimized. Under the optimum experimental conditions, the linear range and detection limit are 1.46-342.0 ${\mu}g/ml$ and 0.072 ${\mu}g/ml$, respectively. The correlation coefficient (R) was 0.99732. The utility of this method was demonstrated by determining mandelic acid in capsules and human urine sample.

Simple and Rapid Identification of Low Level Hepatitis B Virus DNA by the Nested Polymerase Chain Reaction

  • Jang, Jeong-Su;Lee, Kong-Joo
    • Archives of Pharmacal Research
    • /
    • 제19권6호
    • /
    • pp.469-474
    • /
    • 1996
  • A rapid and sensitive method has been developed to detect hepatitis B virus DNA (HBV) by nested polymerase chain reaction (PCR) technique with primers specific for the surface and core regions in capillary thermal cycler within 80 min. The lower limit for detection by present PCR method is $10^{-5}$ pg of recombinant HBV DNA which is equivalent to that determined by one round of PCR amplification and Southern blot hybridization analysis. When boiled HBV positive serum was serially diluted 10-fold, HBV DNA was successfully determined in $1{\mu}l-10^{-3}$ of serum. HBV DNA was detected by present method in 69 clinical samples including HBsAg positives and negatives by enzyme-linked immunosorbent assay (ELISA). When serum samples were amplified by nested PCR using surface and core region primers, HBV DNAs were detected in 37 of 69 samples (53.6%) and 18 of 69 samples (26.1%), respectively. These results can inform the infectious state of HBsAg positive pateints. A simple and rapid nested PCR protocol by using boiled serum as DNA template has been described for the clinical utility to determine HBV DNA in human serum.

  • PDF

A statistical reference-free damage identification for real-time monitoring of truss bridges using wavelet-based log likelihood ratios

  • Lee, Soon Gie;Yun, Gun Jin
    • Smart Structures and Systems
    • /
    • 제12권2호
    • /
    • pp.181-207
    • /
    • 2013
  • In this paper, a statistical reference-free real-time damage detection methodology is proposed for detecting joint and member damage of truss bridge structures. For the statistical damage sensitive index (DSI), wavelet packet decomposition (WPD) in conjunction with the log likelihood ratio was suggested. A sensitivity test for selecting a wavelet packet that is most sensitive to damage level was conducted and determination of the level of decomposition was also described. Advantages of the proposed method for applications to real-time health monitoring systems were demonstrated by using the log likelihood ratios instead of likelihood ratios. A laboratory truss bridge structure instrumented with accelerometers and a shaker was used for experimental verification tests of the proposed methodology. The statistical reference-free real-time damage detection algorithm was successfully implemented and verified by detecting three damage types frequently observed in truss bridge structures - such as loss of bolts, loosening of bolts at multiple locations, sectional loss of members - without reference signals from pristine structure. The DSI based on WPD and the log likelihood ratio showed consistent and reliable results under different damage scenarios.

PCR Diagnosis of Entamoeba histolytica Cysts in Stool Samples

  • Moon, Joung-Ho;Cho, Shin-Hyeong;Yu, Jae-Ran;Lee, Won-Ja;Cheun, Hyeng-Il
    • Parasites, Hosts and Diseases
    • /
    • 제49권3호
    • /
    • pp.281-284
    • /
    • 2011
  • Amebiasis is a protozoan disease caused by Entamoeba histolytica and a potential health threat in areas where sanitation and hygiene are inappropriate. Highly sensitive PCR methods for detection of E. histolytica in clinical and environmental samples are extremely useful to control amebiasis and to promote public health. The present study compared several primer sets for small subunit (SSU) rDNA and histone genes of E. histolytica cysts. A 246 bp of the SSU rDNA gene of pure cysts contained in phosphate-buffered saline (PBS) and in stool samples was successfully amplified by nested PCR, using the 1,147-246 bp primer set, of the primary PCR products which were pre-amplified using the 1,147 bp primer as the template. The detection limit of the nested PCR using the 1,147-246 primer set was 10 cysts in both groups (PBS and stool samples). The PCR to detect histone gene showed negative results. We propose that the nested PCR technique to detect SSU rDNA can be used as a highly sensitive genetic method to detect E. histolytica cysts in stool samples.

Determination of N-nitrosodimethylamine in zidovudine using high performance liquid chromatography-tandem mass spectrometry

  • Yujin Lim;Aelim Kim;Yong-Moon Lee;Hwangeui Cho
    • 분석과학
    • /
    • 제36권6호
    • /
    • pp.281-290
    • /
    • 2023
  • Zidovudine is an antiretroviral agent prescribed for the prevention and treatment of human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS). It is typically recommended to be used in combination with other antiretroviral drugs. Zidovudine has the potential to generate N-nitrosodimethylamine (NDMA) in the presence of dimethylamine and nitrite salt under acidic reaction conditions during the drug manufacturing process. NDMA is a potent human carcinogen that may be detected in drug substances or drug products. An analytical method was developed to determine NDMA in pharmaceuticals including zidovudine using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The analysis involved reversed-phase chromatography on a Kinetex F5 column with a mobile phase comprising water-acetonitrile mixtures. The detection of positively charged ions was conducted using atmospheric pressure chemical ionization (APCI). The calibration curve demonstrated excellent linearity (r = 0.9997) across the range of 1-50 ng/mL with a highly sensitive limit of detection (LOD) at 0.3 ng/mL. The developed method underwent thorough validation for specificity, linearity, accuracy, precision, robustness, and system suitability. This sensitive and specific analytical method was applied for detecting NDMA in zidovudine drug substance and its formulation currently available in the market, indicating its suitability for drug quality management purposes.

A Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay (ELISA) Based on a Monoclonal Antibody Specific to Thermal Stable-Soluble Protein in Pork Fat for the Rapid Detection of Pork Fat Adulterated in Heat-Processed Beef Meatballs

  • Sol-A Kim;Jeong-Eun Lee;Dong-Hyun Kim;Song-min Lee;Hee-Kyeong Yang;Won-Bo Shim
    • 한국축산식품학회지
    • /
    • 제43권6호
    • /
    • pp.989-1001
    • /
    • 2023
  • Processed foods containing pork fat tissue to improve flavor and gain economic benefit may cause severe issues for Muslims, Jews, and vegetarians. This study aimed to develop an indirect enzyme-linked immunosorbent assay (iELISA) based on a monoclonal antibody specific to thermal stable-soluble protein in pork fat tissue and apply it to detect pork fat tissue in heat-processed (autoclave, steam, roast, and fry) beef meatballs. To develop a sensitive iELISA, the optimal sample pre-cooking time, coating conditions, primary and secondary dilution time, and various buffer systems were tested. The change in the iELISA sensitivity with different 96-well microtiter microplates was confirmed. The detection limit of iELISA performed with an appropriate microplate was 0.015% (w/w) pork fat in raw and heat-treated beef. No cross-reactions to other meats or fats were shown. These results mean that the iELISA can be used as an analytical method to detect trace amounts of pork fat mixed in beef.

Identification and genetic characterization of bacterial isolates causing brown blotch on cultivated mushrooms in Korea

  • Chan-Jung Lee;Hye-Sung Park;Seong-Yeon Jo;Gi-Hong An;Ja-Yun Kim;Kang-Hyo Lee
    • 한국버섯학회지
    • /
    • 제22권2호
    • /
    • pp.37-47
    • /
    • 2024
  • Fluorescent bacteria were isolated from sporocarps that browned into various mushrooms during survey at places of the production in Korea. We examined the pathogenicity, biodiversity, and genetic characteristics of the 19 strains identified as Pseudomonas tolaasii by sequence analysis of 16S rRNA and White Line Assay. The results emphasize the importance of rpoB gene system, fatty acid profiles, specific and sensitive PCR assays, and lipopeptide detection for the identification of P. tolaasii. As a result of these various analyses, 17 strains (CHM03~CHM19) were identified as P. tolaasii. The phylogenetic analysis based on the 16S rRNA gene showed that all strains were clustered closest to P. tolaasii lineage, two strains (CHM01, CHM02) were not identified as P. tolaasii and have completely different genetic characteristics as a result of fatty acids profile, specific and sensitive PCR, lipopetide detection, rpoB sequence and REP-PCR analysis. Pathogenicity tests showed 17 strains produce severe brown discolouration symptoms to button mushrooms and watersoaking of sporophore tissue within three days after inoculation. But two strains did not produce discolouration symptoms. Therefore, these two strains will be further investigated for correct species identification by different biological and molecular characteristics.