• Title/Summary/Keyword: self-stabilization structure

Search Result 21, Processing Time 0.025 seconds

A Study on the Stabilization Process of Truss Structure Stabilized by Cable Tension (장력안정트러스 구조물의 안정화기법에 관한 연구)

  • 권택진;한상을;김충한;최옥훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.330-339
    • /
    • 1996
  • The primary objective of this paper is to grasp characteristics of unit system, for the stabilization of stablized truss structure that is an assemblage of unit system by prestress. This unit system is composed of a central post and eight cables, and is connected by hinge joints, and stabilized by the self-equilibrated stress system. As this unit structures itself is a statically closed and stabilized system individually, it can be employed to assemble a structure with a variety of configuration. In this paper, for the stabilization of truss structure stabilized by cable tension, it is proposed the self-equilibrated axial mode equation and the range of the various geometrical parameter about unit system.

  • PDF

A Study on the Stabilization Process of Tensegrity System using the Force Density Method (내력밀도법을 이용한 텐세그러티 구조물의 안정화 기법에 관한 연구)

  • Sur, Sam-Yeol;Koh, Kwang-Ung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.4 s.10
    • /
    • pp.77-84
    • /
    • 2003
  • Tensegrity systems are stable structures which are reticulated spatial structures composed of compressive straight members, struts and cables. But there are some difficulties concerning surface stability, surface formation and construction method. One of the ways to solve this problem reasonably is combination of tesile members and rigid members. This structure is a type of flexible strutural system which is unstable initially because the cable material has little initial rigidity. Therefore tensegrity structure need to be introduced to the Initial stress for the self-equilibrated system having stable state. The rigidification of tensegrity systems is related to selfstress states which can be achieved only when geometrical and mechanical requirements are simultaneously satisfied. In this paper, for the stabilization of tesnsegrity structure it is proposed the modified self-equilibrated equation and the range of the various geometrical parameter about unit system. And we generate the model of double layed single curvature arch using the new squew quadruplex unit system.

  • PDF

Stabilization Control of Inverted Pendulum by Self tuning Fuzzy Inference Technique (자기동조 피지추론 기법에 의한 도립진자의 안정화 제어)

  • Shim, Young-Jin;Kim, Tae-Woo;Lee, Oh-Keol;Park, Young-Sik;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.83-85
    • /
    • 1997
  • In this paper, a self-tunning fuzzy inference technique for stabilization of the inverted pendulum system is proposed. The facility of this self-tunning fuzzy controller which has swing-up control mode and a stabilization one, moves a pendulum in an initial natural stable equilibrium point and a cart in arbitrary position, to an unstable equilibrium point and a center of rail. Specially, the virtual equilibrium point(${\phi}_{VEq}$) which describes functionally considers the interactive dynamics between a position of cart and a angle of inverted pendulum is introduced. And comparing with the convention optimal controller, the proposed self-tunning fuzzy inference structure made substantially the inverted pendulum system robust and stable.

  • PDF

Determination of the Boundary of Parameters for Stabilization of Truss Structures Stabilized by Cable Tension (장력안정트러스 구조물의 안정화를 위한 매개변수의 범위 결정에 관한 연구)

  • 권택진;한상을;최옥훈
    • Computational Structural Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 1997
  • The charateristics of stabilization for stabilized truss unit-structures with cable and truss are investigated in this paper. This unit system is composed of a central post and eight cables, and is connected by hinge joints, and stabilized by self-equilibrated stress field. As this unit structure itself is a statically closed and stabilized system individually, it can be employed to assemble structures with various configurations. In this study, for stabilization of truss structures stabilized by cable tension, the structural concept of unit structures, the range of various geometrical parameters and the relationship of governing parameters about unit systems are explained.

  • PDF

Determination of Operating frequency its Design of the Self-exited electronic Ballast (자려식 전자안정기의 동작 주파수 결정과 설계)

  • 박종연;전경준;한재현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.315-318
    • /
    • 2002
  • In this paper, we have studied about the determination methode of the operating frequency, and the design technique for the self-exited electronic ballast. Because we use the saturation characteristics of the ferrite core, the variation of the B/H curve characteristics for the selected core in the most important factor for the stabilization. Although it is impossible to fix the operation frequency, the self-exited electronic ballast is widely used because of its cost and the simplicity of its structure.

  • PDF

Supramolecular Nanomaterials Derived from Self-Assembly of Dendritic Building Blocks

  • Park, Chi-Young;Lee, Sang-Wha;Lim, Ji-No;Lim, Moon-Seob;Kim, Chul-Hee
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.91-92
    • /
    • 2006
  • The fine-tuned dendrons provide unique supramolecular self-assemblies in various environments such as in water, organic media, and solid-liquid interfaces. They form nanotubes, vesicles, thin films, columns, lamellar nanoribbons depending on the condition of self-assembly process. Unique characteristics of self-assembly of the amide dendrons are described. In addition, elucidation of the structural correlation between the building blocks and the assemblies, stabilization of assembled structure, and transformation of supramolecular assemblies by using external stimuli. Particular emphasis is placed on the formation of cyclodextrin-covered organic nanotubes derived from self-assembly of amide dendrons and their supramolecular transformation. Finally, unique biosensory characteristics of the self-assembled nanotubes will be discussed.

  • PDF

A caving self-stabilization bearing structure of advancing cutting roof for gob-side entry retaining with hard roof stratum

  • Yang, Hongyun;Liu, Yanbao;Cao, Shugang;Pan, Ruikai;Wang, Hui;Li, Yong;Luo, Feng
    • Geomechanics and Engineering
    • /
    • v.21 no.1
    • /
    • pp.23-33
    • /
    • 2020
  • An advancing cutting roof for gob-side entry retaining with no-pillar mining under specific geological conditions is more conducive to the safe and efficient production in a coalmine. This method is being promoted for use in a large number of coalmines because it has many advantages compared to the retaining method with an artificial filling wall as the gateway side filling body. In order to observe the inner structure of the gateway cutting roof and understand its stability mechanism, an equivalent material simulation experiment for a coalmine with complex geological conditions was carried out in this study. The results show that a "self-stabilization bearing structure" equilibrium model was found after the cutting roof caving when the cut line deviation angle was unequal to zero and the cut height was greater than the mining height, and the caving roof rock was hard without damage. The model showed that its stability was mainly controlled by two key blocks. Furthermore, in order to determine the optimal parameters of the cut height and the cut line deviation angle for the cutting roof of the retaining gateway, an in-depth analysis with theoretical mechanics and mine rock mechanics of the model was performed, and the relationship between the roof balance control force and the cut height and cut line deviation angle was solved. It was found that the selection of the values of the cut height and the cut line deviation angle had to conform to a certain principle that it should not only utilize the support force provided by the coal wall and the contact surface of the two key blocks but also prevent the failure of the coal wall and the contact surface.

The Effect of solid Waste Landfill Method on Decomposition of pollutants in Semi-aerobic Landfill Structure (준호기성 매립구조에 있어서 폐기물 매립방법이 오염물질의 분해에 미치는 영향)

  • Lee, Nam-Hoon;Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.4
    • /
    • pp.153-159
    • /
    • 2000
  • Large-scale simulated lysimeter experiments were conducted for 4 years as a fundamental study to develop enhanced landfill stabilization method, which accelerate stabilization time and make efficient practical use of self-purification capacity of pollutants in semi-aerobic solid waste landfill. The amount of TOC(total organic carbon) decomposition increased as the landfill depth increased. In case of T-N(total nitrogen), the self-purification capacity increased linearly with the landfill thickness until it reached a maximum level of 6 m. Beyond this level, the self-purification capacity was not increased. The results from lysimeter experiments indicate that 6m of landfill thickness is optimum for self-purification capacity of pollutants considering the mass balance of TOC and T-N.

  • PDF

Study on Selection of HTS Wire for Fabrication of Fault Current-limiting Type HTS Cables (사고전류 제한형 초전도케이블 제작을 위한 초전도 선재 선정에 관한 연구)

  • Heo, Soung-Ouk;Kim, Tae-Min;Han, Byung-Sung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.12
    • /
    • pp.904-908
    • /
    • 2013
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through a high-capacity and high-$T_c$ superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate measure to protect it. Therefore, appropriate measures are needed to protect HTS cables. The fault-current-limiting HTS cable that was suggested in this study performs an ideal transport current function in normal operations and plays a role in limiting a fault current in abnormal operation (i.e., when a fault current is applied). It has a structure that facilitated its self-current-limiting ability through device change and reconfiguration in the existing HTS cable without extra switching equipment. To complete this structure, it is essential to investigate about the selection of the superconducting wire. Therefore, in this paper, HTS wire using two types of different stabilization layer is compared and examined the stability and current limiting properties under the existence of a fault current.

Load Frequency Control using Parameter Self-Tuning fuzzy Controller (파라미터 자기조정 퍼지제어기를 이용한 부하주파수제어)

  • 탁한호;추연규
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.2
    • /
    • pp.50-59
    • /
    • 1998
  • This paper presents stabilization and adaptive control of flexible single link robot manipulator system by self-recurrent neural networks that is one of the neural networks and is effective in nonlinear control. The architecture of neural networks is a modified model of self-recurrent structure which has a hidden layer. The self-recurrent neural networks can be used to approximate any continuous function to any desired degree of accuracy and the weights are updated by feedback-error learning algorithm. When a flexible manipulator is rotated by a motor through the fixed end, transverse vibration may occur. The motor toroque should be controlled in such a way that the motor rotates by a specified angle, while simultaneously stabilizing vibration of the flexible manipuators so that it is arresed as soon as possible at the end of rotation. Accurate vibration control of lightweight manipulator during the large changes in configuration common to robotic tasks requires dynamic models that describe both the rigid body motions, as well as the flexural vibrations. Therefore, a dynamic models for a flexible single link robot manipulator is derived, and then a comparative analysis was made with linear controller through an simulation and experiment. The results are proesented to illustrate thd advantages and imporved performance of the proposed adaptive control ove the conventional linear controller.

  • PDF