• 제목/요약/키워드: self-adhesive

검색결과 303건 처리시간 0.026초

계면 누수를 통한 자착형 방수시트의 저온 부착 특성에 관한 연구 (A study on the characteristic of adhesion on the low temperature concrete of self adhesive waterproofing sheet using interface leakage test.)

  • 최수영;김명지;이정훈;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2014
  • Recently, waterproof construction used to self adhesive waterproofing sheet in the actual field in winter for reduce cost and term. However self adhesive waterproofing sheet's quality is declined in low temperature condition. So, this study was to confirm on the low temperature condition of concrete substrate effecting the adhesion of self adhesion waterproofing sheet using interface leakage test. As a result of this study, self adhesion waterproofing sheet must not be used at temperature below 5℃. Also, adhesion between waterproofing sheet and concrete is declined in low temperature.

  • PDF

Self-Alignment and Bonding of Microparts Using Adhesive Droplets

  • Sato, Kaiji;Lee, Keun-Uk;Nishimura, Masahiko;Okutsu, Kazutoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.75-79
    • /
    • 2007
  • This paper describes the self-alignment and bonding of microparts using adhesive surface tension to assemble microsystems in air. The alignment and bonding were tested experimentally using adhesive droplets, and the resulting performance was evaluated. The adhesive, which was inorganic and water-soluble before hardening, was diluted with water to a ratio of 10:1 so that its surface tension generated a sufficient restoring force for self-alignment. The experimental results showed that the average of the alignment errors obtained using the adhesive on $1.0\times1.0\times0.15-mm$ microparts was less than $2{\mu}m$ in the X and Y directions and 0.2 degrees in the e direction. These alignment errors were almost the same as those obtained using water. The use of a suitable adhesive had no negative effects on the alignment accuracy. The average tensile strength of the adhesive bond after self-alignment was $0.61N/mm^2$.

Effect of Hydrophobic, Neutral Adhesive on the Dentin Bond Strength of Self-etching Adhesive

  • Bae, Ji-Hyun;Choi, Yong-Hoon;Jung, Moon-Kyung;Cho, Byeong-Hoon
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.5-11
    • /
    • 2009
  • Objectives : This study investigated the hypothesis that the dentin bond strength of self-etching adhesives (SEAs) may be improved by applying a coat of hydrophobic, neutral adhesive resin in addition to SEA. Method and Materials : The bond strengths of two SEAs - Experimental SEA (EX) and Adper Prompt (AP) - were measured with three bonding protocols. The D/E resin of All-Bond 2 was applied as the hydrophobic, neutral adhesive. Clearfil SE Bond (SE, self-etching primer system) and All-Bond 2 (AB, total etching system) were used as references. The following protocols were used: (1) EX1 (EX 1 coat); (2) EX2 (EX 2 coats); (3) EX+ (EX 1 coat + D/E resin); (4) AP1 (AP 1 coat); (5) AP2 (AP 2 coats); (6) AP+ (AP 1 coat + D/E resin); (7) SE (SE primer + SE bond); (8) SE+ (SE primer + D/E resin); (9) AB (etching + AB primer + D/E resin). Filtek Z250 composite resin was built up and the microtensile bond strength (MTBS) values of the specimens were compared. The fractured surfaces were observed using SEM. Results : When SEA was used as self-etching primer and hydrophobic, neutral adhesive was applied as well, MTBS was significantly higher than that when either one coat or two coats of SEA only were used (p < 0.05). Conclusion : The hydrophobic, neutral adhesive improved the integrity of the bonded interface obtained with SEA.

  • PDF

Bond strength of self-adhesive resin cements to composite submitted to different surface pretreatments

  • dos Santos, Victor Hugo;Griza, Sandro;de Moraes, Rafael Ratto;Faria-e-Silva, Andre Luis
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.12-16
    • /
    • 2014
  • Objectives: Extensively destroyed teeth are commonly restored with composite resin before cavity preparation for indirect restorations. The longevity of the restoration can be related to the proper bonding of the resin cement to the composite. This study aimed to evaluate the microshear bond strength of two self-adhesive resin cements to composite resin. Material and Methods: Composite discs were subject to one of six different surface pretreatments: none (control), 35% phosphoric acid etching for 30 seconds (PA), application of silane (silane), PA + silane, PA + adhesive, or PA + silane + adhesive (n = 6). A silicone mold containing a cylindrical orifice ($1mm^2$ diameter) was placed over the composite resin. RelyX Unicem (3M ESPE) or BisCem (Bisco Inc.) self-adhesive resin cement was inserted into the orifices and light-cured. Self-adhesive cement cylinders were submitted to shear loading. Data were analyzed by two-way ANOVA and Tukey's test (p < 0.05). Results: Independent of the cement used, the PA + Silane + Adhesive group showed higher microshear bond strength than those of the PA and PA + Silane groups. There was no difference among the other treatments. Unicem presented higher bond strength than BisCem for all experimental conditions. Conclusions: Pretreatments of the composite resin surface might have an effect on the bond strength of self-adhesive resin cements to this substrate.

Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

  • Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.155-159
    • /
    • 2012
  • Objectives: To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems. Materials and Methods: Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil $S^3$ Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05). Results: All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil $S^3$ Bond, dry dentin surface and 10 sec air drying time showed higher bond strength. Conclusions: Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.

CRUSHING CHARACTERISTIC OF DOUBLE HAT-SHAPED MEMBERS OF DIFFERENT MATERIALS JOINED BY ADHESIVE BONDING AND SELF-PIERCING RIVET

  • Lee, M.H.;Kim, H.Y.;Oh, S.I.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.565-570
    • /
    • 2006
  • The development of a light-weight vehicle is in great demand for enhancement of fule efficiency and dynamic performance. The vehicle weight can be reduced effectively by using lightweight materials such as aluminum and magnesium. However, if such materials are used in vehicles, there are often instances when different materials such as aluminum and steel need to be joined to each other. The conventional joining method, namely resistance spot welding, cannot be used in joining different materials. Self-piercing rivet(SPR) and adhesive bonding, however, are good alternatives to resistance spot welding. This paper is concerned with the crushing test of double hat-shaped member made by resistance spot welding, SPR and adhesive bonding. Various parameters of crashworthiness are analyzed and evaluated. Based on these results, the applicability of SPR and adhesive bonding are proposed as an alternative to resistance spot welding.

셀프레벨링 모르타르용 Primer 성상에 따른 특성평가에 관한 실험적 연구 (An Experimental Study on the Characteristics of Evaluation with Feature of Self Levelling Primer)

  • 강동균;김경덕;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.505-508
    • /
    • 2006
  • Self-leveling mortar is walkable bottom mortar which can maintain the horizontality of self fluid and have the the quick-setting quality, the low-human-effort practicable material of high-quality bottom in construction. In accordance with more adhesive strength with bottom side and absorption control, Primer is used for purpose to prevent pin-hole occurrence by self leveling mortar application prior to construction. This study is composed measurement of absorption, adhesive strength. Used material is NP-40 as nonionic emulsifying agent, uses SA-210L as negative ion emulsifying agent, uses APS, SBS as ridical initiator. A result of test, in accordance with image of Primer, as low temperature and application frequency, indicates low absorption rate and adhesive strength, as solid powder and dryness time is increse, absorption rate and adhesive strength lowly shows figure.

  • PDF

Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구 (A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer)

  • 김유경;이진우;차경석
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.325-332
    • /
    • 2004
  • 본 연구의 목적은 산부식과 전처리 과정을 결합하여 접착 단계를 단순화시킨 self-etching primer의 임상적인 유용성 을 판단하고자, self-etching primer로 브라켓을 접착하는 방법과 기존의 $37\%$ 인산으로 부식하여 접착하는 방법을 사용하여, 광중합시 사용되는 광원 및 브라켓 종류에 따른 전단결합강도와 접착파절양상에 관하여 비교 연구하는 것이다. 사람의 상하악 소구치를 포매하여 만든 시편을 부식 및 전처리 방법에 따라 각각 $37\%$ 인산으로 산부식 후 Transbond XT primer를 사용하여 접착한 군과 Transbond Plus self-etching primer를 사용하여 접착한 군으로, 광원 종류에 따라 가시광선과 plasma arc light을 이용하여 중합한 군으로 나누었고, 브라켓 종류에 따라 금속브라켓과 세라믹 브라켓을 사용하여 접착한 군으로 분류하여 각 군간의 전단결합강도와 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 광원과 브라켓 종류가 동일한 조건일 때, self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군간의 전단결합강도는 통계적으로 유의한 차가 없었다. 2. 금속브라켓을 접착한 경우, 광원과 부식 및 전처리 방법에 따른 전단결합강도는 통계적으로 유의한 차가 없었다. 3. Self-etching primer와 XT primer를 사용하여 접착한 군 모두에서 세라믹 브라켓을 사용하여 접착한 군의 전단결합 강도는 금속브라켓을 사용하여 접착한 군보다 통계적으로 유의하게 컸다(p<0.001). 4. 접착제 잔류지수는 self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군에서 통계적인 유의한 차가 없었으며, 세라믹 브라켓을 사용하여 접착한 군에서 금속브라켓을 사용하여 접착한 군보다 유의하게 커서, 법랑질-레진 접착 계면 부위의 파절이 더 많은 것으로 나타났다. 이상의 결과로 미루어 보아 Transbond Plus self-etching primer를 사용하여 브라켓을 접착하는 것은 적절한 결합강도를 얻으면서도 사용이 간편하고 시술 시간을 단축시킬 수 있으므로 임상적으로 유용할 것으로 판단된다.

The effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin

  • Acar, Ozlem;Tuncer, Duygu;Yuzugullu, Bulem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.88-95
    • /
    • 2014
  • PURPOSE. The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS. Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA) 2) Aqua-Prep F-(Fluoride), 3) Bisblock-(Oxalate), 4) Cervitec Plus-(Clorhexidine), 5) Smart protect-(Triclosan), 6) Nd:YAG laser, 7) No treatment (control). After applying the selected agent, RelyX U200 self-adhesive resin cement was used to bond composite resin blocks to dentin. All groups were subjected to thermocycling for 1000 cycles between $5-55^{\circ}C$. Each bonded specimen was sectioned to microbars ($6mm{\times}1mm{\times}1mm$) (n=20). Specimens were submitted to microtensile bond strength test at a crosshead speed of 0.5 mm/min. Kolmogorov-Smirnov, Levene's test, Kruskal-Wallis One-way Analysis of Variance, and Conover's nonparametric statistical analysis were used (P<.05). RESULTS. Gluma, Smart Protect and Nd:YAG laser treatments showed comparable microtensile bond strengths compared with the control group (P>.05). The microtensile bond strengths of Aqua-Prep F, and Cervitec Plus were similar to each other but significantly lower than the control group (P<.05). Bisblock showed the lowest microtensile bond strength among all groups (P<.001). Most groups showed adhesive failure. CONCLUSION. Within the limitation of this study, it is not recommended to use Aqua-prep F, Cervitec Plus and Bisblock on dentin when used with a self-adhesive resin cement due to the decrease they cause in bond strength. Beside, pre-treatment of dentin with Gluma, Smart protect, and Nd:YAG laser do not have a negative effect.

Interface between calcium silicate cement and adhesive systems according to adhesive families and cement maturation

  • Nelly Pradelle-Plasse;Caroline Mocquot;Katherine Semennikova;Pierre Colon;Brigitte Grosgogeat
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.3.1-3.14
    • /
    • 2021
  • Objectives: This study aimed to evaluate the interface between a calcium silicate cement (CSC), Biodentine and dental adhesives in terms of sealing ability. Materials and Methods: Microleakage test: 160 standardized class II cavities were prepared on 80 extracted human molars. The cavities were filled with Biodentine and then divided into 2 experimental groups according to the time of restoration: composite resin obturation 15 minutes after Biodentine handling (D0); restoration after 7 days (D7). Each group was then divided into 8 subgroups (n = 5) according to the adhesive system used: etch-and-rinse adhesive (Prime & Bond); self-etch adhesive 2 steps (Optibond XTR and Clearfil SE Bond); self-etch adhesive 1 step (Xeno III, G-aenial Bond, and Clearfil Tri-S Bond); and universal used as etch-and-rinse or self-etch (ScotchBond Universal ER or SE). After thermocycling, the teeth were immersed in a silver nitrate solution, stained, longitudinally sectioned, and the Biodentine/adhesive percolation was quantified. Scanning electron microscopic observations: Biodentine/adhesive interfaces were observed. Results: A tendency towards less microleakage was observed when Biodentine was etched (2.47%) and when restorations were done without delay (D0: 4.31%, D7: 6.78%), but this was not significant. The adhesives containing 10-methacryloyloxydecyl dihydrogen phosphate monomer showed the most stable results at both times studied. All Biodentine/adhesive interfaces were homogeneous and regular. Conclusions: The good sealing of the CSC/adhesive interface is not a function of the system adhesive family used or the cement maturation before restoration. Biodentine can be used as a dentine substitute.