• Title/Summary/Keyword: self-Inspection

Search Result 270, Processing Time 0.027 seconds

Self-Diagnosis Property of Fracture in Carbon Fiber Composite Mortar (탄소섬유 분말 혼입 모르타르 복합 구조체의 파괴예측 자가진단 특성)

  • Park, Seok-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.113-120
    • /
    • 2007
  • A new material was tested and its applicability was investigated so as to give the capability of self-diagnosis of fracture in composite mortar. In the research for giving self-diagnosis capability, conductive mortar intermixed with cokes and carbon fiber powder(milled carbon fiber) was developed and its using for self-diagnosis material was proposed. Then after examining change in the value of electric resistance and AE characteristics before and after the occurrence of cracks at each weight-stage, the relationships of each factors were analyzed. As the results, it can be recognized that a new composite material with cokes and carbon fiber powder(milled carbon fiber) can be applied for self-diagnosis of fracture in mortar specimen.

Development of Health Monitoring System Using Self Magnetization Magnetostrictive Sensor (자기자화자왜센서를 이용한 설비 off-line Health Monitoring 시스템 개발)

  • Kim, Yi-Gon;Moon, Hong-Sik;Kim, Jun;Kim, Ji-Hyeon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.481-486
    • /
    • 2012
  • This thesis examines the development and application of 'Health Monitoring System' which monitors periodically the state of a pipe of petrochemical plant by using magnetostrictive sensor technology. The existing guided-wave inspection methods cannot be applied to welding part inspection in pipe, and has a limit of precision when applied to general parts because of noise, reflected waves, and so on. This technology uses the information on displacement of a defect through periodic monitoring, which makes more precise inspection, and can be utilized very usefully in a petrochemical plant.

Effects of Serial Passage on the Characteristics and Chondrogenic Differentiation of Canine Umbilical Cord Matrix Derived Mesenchymal Stem Cells

  • Lee, K.S.;Cha, S.H.;Kang, H.W.;Song, J.Y.;Lee, K.W.;Ko, K.B.;Lee, H.T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.4
    • /
    • pp.588-595
    • /
    • 2013
  • Mesenchymal stem cells (MSCs) are often known to have a therapeutic potential in the cell-mediated repair for fatal or incurable diseases. In this study, canine umbilical cord MSCs (cUC-MSCs) were isolated from umbilical cord matrix (n = 3) and subjected to proliferative culture for 5 consecutive passages. The cells at each passage were characterized for multipotent MSC properties such as proliferation kinetics, expression patterns of MSC surface markers and self-renewal associated markers, and chondrogenic differentiation. In results, the proliferation of the cells as determined by the cumulative population doubling level was observed at its peak on passage 3 and stopped after passage 5, whereas cell doubling time dramatically increased after passage 4. Expression of MSC surface markers (CD44, CD54, CD61, CD80, CD90 and Flk-1), molecule (HMGA2) and pluripotent markers (sox2, nanog) associated with self-renewal was negatively correlated with the number of passages. However, MSC surface marker (CD105) and pluripotent marker (Oct3/4) decreased with increasing the number of subpassage. cUC-MSCs at passage 1 to 5 underwent chondrogenesis under specific culture conditions, but percentage of chondrogenic differentiation decreased with increasing the number of subpassage. Collectively, the present study suggested that sequential subpassage could affect multipotent properties of cUC-MSCs and needs to be addressed before clinical applications.

Mechanical and Electrical Characteristics of Concrete Members Enlarged with Self-Sensing Cementitious Materials for Repair (자기감지형 보수재로 단면증타된 콘크리트 부재의 역학 및 전기적 특성 )

  • Gun-Cheol Lee;Geon-Woo Im;Chang-Min Lee;Sung-Won Hong;Young-Min Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.139-146
    • /
    • 2023
  • In this study, compressive strength and adhesion strength were measured as repair materials to evaluate the mechanical and electrical properties of compression and shear specimens with self-sensing repair materials. As a result of the experiment, the strength improvement rate of the compression test specimen was higher than the section enlargement area ratio, but the shear test specimen did not show an improvement in strength as much as the section enlargement area ratio. Compression experiments under load showed high correlation between FCR-Strain and FCR-Stress, confirming self-sensing performance. However, the shear test did not show as much correlation as the compression test. Accordingly, it is judged that the self-sensing repair material is suitable for the compression member on which the compression load acts in the building.

Determination of Key Factors and Evaluation of Their Importance in the Elevator Safety Quality Rating System for the Purpose of Adjusting the Elevator Inspection Cycle (승강기 검사주기 조정을 위한 안전품질 등급제 핵심항목 선정 및 중요도 평가)

  • Kyung-Min Roh;Kwan-Hee Han
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.70-78
    • /
    • 2022
  • Recently, elevator inspection and self-examination were strengthened through the revision of the Elevator Safety Management Act, but there have been no significant reduction in serious accidents and major failures. Therefore, the government intends to lay the foundation for reflecting the safety quality rating system, which adjusts the elevator inspection cycle, as a policy to induce safety management of preemptive and active management entities. This study systematically reviewed and classified the safety quality rating system for elevator inspection cycle adjustment in previous studies, collected expert opinions, and reconstructed the key items into realistic evaluation items, and evaluated and scored the relative importance of each factor through the AHP technique.

Evaluation of Self-Healing Performance for Mortar Beams Containing Self-Healing Materials (자기치유 재료 혼입 모르타르 보의 자기치유 성능 평가)

  • Shin, DongIk;Muhammad, Haroon;Min, Kyung Sung;Lee, Kwang-Myong;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.67-73
    • /
    • 2020
  • In this study, the self-healing performance of mortar beams containing self-healing materials was evaluated through experiments. Normal mortar beams and self-healing mortar beams were used In the experiments. The self-healing performance was evaluated by comparing the mortar compressive strength, member strength, and self-healing effects of cracks. The experimental results showed that the compressive strength of mortar containing self-healing material was smaller than that of normal mortar, but the ratio of 118 days compressive strength to 28 days compressive strength was the same. The member strength tended to increase with increasing curing period. In normal mortar specimens, the member strength did not recover even if the curing period increased, but the strength of the self-healing mortar specimens tended to recover as reaction products were produced. The crack width tended to decrease after the healing periods in both specimens, but the reaction product was observed only in the self-healing mortar specimens.

Development of an Inspection Item and its Application for the Hygienic Improvement of Food service Establishments Using (식품접객 업소의 위생개선을 위한 검사항목 개발과 활용에 관한 연구 -HACCP 모델을 이용한 기여인자 분석방법으로)

  • 홍종해;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.7 no.2
    • /
    • pp.133-145
    • /
    • 1992
  • The sanitation inspection is the most frequently used procedure to protect foods prepared in foodservice establishments. In order to enhance foodservice inspections and to improve post-inspection remedial measures, more practical evaluation methods for sanitation are required. The HACCP approach is based upon factors which contribute to foodborne disease rather than of factors which relate to aesthetics. Contributing factors for foodborne diseases from food service establishments reported in USA, Candada, and England were analyzed to identify potential hazards during practical foodservice operations. Hazards were classified at critical control points by risk ranking, Twenty-two observable practical indicators relating to each contributing factor were selected and adjusted to standardized procedures and hazard determiners at critical control points, The weights for each inspection item were ranked as 1, 2, 3, 4, or 5 according to the risk level of contributing factors. And also application for the inspection item in different 6 types of work procedures were suggested for the use of specialized foodservice establishment and cafeteria, and of manager's self inspection in each establishment.

  • PDF

Development of an Inspection Item and its Application for the Hygienic Improvement of Foodservice Establishments Using - Hazard Analysis Critical Control Point(HACCP) Model- (식품접객업소(食品接客業所)의 위생개선(衛生改善)을 위(爲)한 검사항목(檢査項目) 개발(開發)과 활용(活用)에 관(關)한 연구(硏究) -HACCP 모델을 이용(利用)한 기여인자(寄與因子) 분석방법(分析方法)으로-)

  • Hong, Chong-Hae;Lee, Yong-Wook
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1992.07a
    • /
    • pp.33-45
    • /
    • 1992
  • The sanitation inspection is the most frequently used procedure to protect foods prepared in foodservice establishments. In order to enhance foodservioe inspections and to improve post-inspection remedial measures, more practical evaluation methods for sanitation are required. The HACCP approach is based upon factors which contribute to foodborne disease rather than on factors which relate to aesthetics. Contributing factors for foodborne disease from foodservice establishments reported in USA, Canada, and England were analyzed to identify potential hazards during practical foodservioe operations. Hazards were classified at critical control points by risk ranking. Twenty-two observable practical indicators relating to each contributing factor were selected and adjusted to standardized procedures and hazard determiners at critical contral points. The weights for each inspection item were ranked as 1, 2, 3, 4 or 5 according to the risk level of contributing factors. And also application for the inspection item in different 6 types of work procedures was suggested for the use of specialized foodservice establishment and cafeteria, and of manager's self inspection in each establishment.

  • PDF

Effectiveness of Direct Safety Regulations on Manufacturers and Users of Industrial Machines: Its Implications on Industrial Safety Policies in Republic of Korea

  • Choi, Gi Heung
    • Safety and Health at Work
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 2017
  • Background: Despite considerable efforts made in recent years, the industrial accident rate and the fatality rate in the Republic of Korea are much higher than those in most developed countries in Europe and North America. Industrial safety policies and safety regulations are also known to be ineffective and inefficient in some cases. Methods: This study focuses on the quantitative evaluation of the effectiveness of direct safety regulations such as safety certification, self-declaration of conformity, and safety inspection of industrial machines in the Republic of Korea. Implications on safety policies to restructure the industrial safety system associated with industrial machines are also explored. Results: Analysis of causes in industrial accidents associated with industrial machines confirms that technical causes need to be resolved to reduce both the frequency and the severity of such industrial accidents. Statistical analysis also confirms that the indirect effects of safety device regulation on users are limited for a variety of reasons. Safety device regulation needs to be shifted to complement safety certification and self-declaration of conformity for more balanced direct regulations on manufacturers and users. An example of cost-benefit analysis on conveyor justifies such a transition. Conclusion: Industrial safety policies and regulations associated with industrial machines must be directed towards eliminating the sources of danger at the stage of danger creation, thereby securing the safe industrial machines. Safety inspection further secures the safety of workers at the stage of danger use. The overall balance between such safety regulations is achieved by proper distribution of industrial machines subject to such regulations and the intensity of each regulation. Rearrangement of industrial machines subject to safety certification and self-declaration of conformity to include more movable industrial machines and other industrial machines with a high level of danger is also suggested.

A Survey on the Sanitary Condition of Kitchens of School Lunch Program

  • Kim, Jong-Gyu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.174-176
    • /
    • 2003
  • A survey was conducted to investigate the sanitary condition of school kitchens in one region of Korea. A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools for food, sanitation and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during food preparation, processing and service. The inspection results showed their sanitary condition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4∼22.4$^{\circ}C$, and the range of relative humidity was 62.4∼69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22.5 to 26.5 CFU/15 min. These results indicate that the levels of sanitary condition of kitchens in the schools were not satisfactory for safe foodservice although the inspection showed good results. This study suggests that the school kitchens should be monitored and strict inspection is necessary.

  • PDF