• Title/Summary/Keyword: self-Inspection

Search Result 273, Processing Time 0.03 seconds

Natural Frequencies of Laminated Composite Plates with Attached Mass Under an Uniform Axial-Loading (등분포 축하중을 받고 첨가질량이 재하된 적층복합판의 고유진동수에 관한 연구)

  • Hong, Chang-Woo;Kim, Kyeong-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.181-190
    • /
    • 2000
  • Vibration analysis for some of simple supported antisymmetric composite laminated plate loaded uniform axial-loading and attached mass was carried out. Because it is complicated to analyze this type of plate by theory of antisymmetric laminate possibility for application of theory of special orthotropic laminate was studied, and natural frequency of laminated plate attached mass was calculated. Stiffness $B_{16}$, $B_{26}$, $D_{16}$, $D_{26}$ for this type of antisymmetric laminated plate converge on zero as the number of ply increases and it is possible to use classical theory by reason that considered plate has quasi-homogeneity without relevance to variation of angle. Difference between results by theory of antisymmetric and special orthotropic laminate is 0.36~1.96%, therefore it is convenient to analyze this by use of theory of special orthotropic laminate. When composite laminated plate with attached mass is analyzed range that Was able to neglect self-weight of plate was proposed.

  • PDF

Development of Real-time Flatness Measurement System of COF Film using Pneumatic Pressure (공압을 이용한 COF 필름의 실시간 위치 평탄도 측정 시스템 개발)

  • Kim, Yong-Kwan;Kim, JaeHyun;Lee, InHwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2021
  • In this paper, an inspection system has been developed where pneumatic instruments are used to stretch the film using compressed air, thus the curl problem can be overcome. When the pneumatic system is applied, a line scan camera should be used instead of an area camera because the COF surface makes an arc by the air pressure. The distance between the COF and the inspection camera should be kept constant to get a clear image, thus the position of COF is to be monitored on real-time. An operating software has been also developed which is switching on/off the pneumatic system, determining the COF position using a camera vision, displaying the contour of the COF side view, sending self-diagnosis result and etc. The developed system has been examined using the actual roll of COF, which convince that the system can be an effective device to inspect the COF rolls in process.

An Experimental Study for Structural Safety Evaluation of PSC Box Girder Bridge with FRP Struts (FRP 스트럿을 가진 PSC 박스거더교의 구조안전성 평가를 위한 실험 연구)

  • Song, Jae-Joon;Park, Jong-Hwa;Park, Kyung-Hoon;Jo, Byung-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.205-213
    • /
    • 2008
  • The structure of PSC box girder with FRP strut has a form of supporting the cantilever part in the widened upper slab by modifying the existing PSC box girder efficiently, and it is able to build an economical and aesthetically pleasing bridge as it reduces the size of the lower structure by reducing the self-weight of the upper structure. In this research, loading test of PSC Box Girder using full-scale mock-up was conducted and FEM analysis was performed. By comparing results, structural safety of the FRP strut and the upper slab following application of the strut in the PSC Box Girder Bridge were evaluated.

A Study on the Development of Self-Repairing Smart Concrete Using Microorganism (미생물(微生物)을 이용한 자기수부성(自己修復性) 스마트 콘크리트 개발에 관한 기초연구)

  • Kim, Wha-Jung;Chun, Woo-Young;Ko, Kwan-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.441-444
    • /
    • 2008
  • This study was conducted to develop self-repairing ability for concrete so that inspection could be available even in the event of minute cracks, for more economic concrete structure maintenance and longevity. This is a basic attempt to develop self-repairing concrete using the biochemical reaction of bacteria through an innovative method. In this study, the characteristics and problems posed by self-repairing concrete as proposed in international scientific journals were examined, and the potential of new concrete reformation and performance improvement using bio-mineralization was explored. Bio-mineralization, which is an action of creating bio-minerals using an organism, was proposed. A new concept of bacteria such as bacillus pasteurii using bio-mineralization that precipitates calcium carbonate, as well as the possibility of mechanical performance and durability of concrete and repair of cracks, was introduced. Directions for further study through basic experiments and developmental feasibility of self-repairing concrete were also presented.

  • PDF

Micro Joining Process Using Solderable Anisotropic Conductive Adhesive (Solderable 이방성 도전성 접착제를 이용한 마이크로 접합 프로세스)

  • Yim, Byung-Seung;Jeon, Sung-Ho;Song, Yong;Kim, Yeon-Hee;Kim, Joo-Heon;Kim, Jong-Min
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.73-73
    • /
    • 2009
  • In this sutdy, a new class ACA(Anisotropic Conductive Adhesive) with low-melting-point alloy(LMPA) and self-organized interconnection method were developed. This developed self-organized interconnection method are achieved by the flow, melting, coalescence and wetting characteristics of the LMPA fillers in ACA. In order to observe self-interconnection characteristic, the QFP($14{\times}14{\times}2.7mm$ size and 1mm lead pitch) was used. Thermal characteristic of the ACA and temperature-dependant viscosity characteristics of the polymer were observed by differential scanning calorimetry(DSC) and torsional parallel rheometer, respectively. A electrical and mechanical characteristics of QFP bonding were measured using multimeter and pull tester, respectively. Wetting and coalescence characteristics of LMPA filler particles and morphology of conduction path were observed by microfocus X-ray inspection systems and cross-sectional optical microscope. As a result, the developed self-organized interconnection method has a good electrical characteristic($2.41m{\Omega}$) and bonding strength(17.19N) by metallurgical interconnection of molten solder particles in ACA.

  • PDF

Effects of Sexuality Education in One Elementary School Students (초등학생 대상 성교육 효과 분석 연구)

  • Seo, Soon-Hee;Lee, Moo Sik;Na, Beag Ju;Kang, Mun Young;Hong, Jee Young
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.13 no.3
    • /
    • pp.73-86
    • /
    • 2012
  • Objectives: This study was conducted to explore the effect of the sexuality education in elementary school in regard to students' knowledge, attitude, and role identity about sex. Methods: We classified students into experimental group and control group, and carries out the planned sexuality education to the experimental group. Study subjects were 200 students in one elementary school. Experimental group compromised of 50 boys and 50 girls, and control group so did. Self-administered questionnaire was used for preliminary investigation from 15th to 16th, October in 2009. The post investigation was carried out to the control group 5 weeks later, and to the experimental group for 5 weeks (total 10 hours, 2hours each a week) after the sexuality education from 23th of November to 25th of November, 2009. Results: Experimental group had significantly higher post-inspection scores of sex-related knowledge, attitude against sex, sex-related role identity (excluding leadership dominance, concession, cheerfulness gentleness and sympathy shyness) than pre-inspection scores. Conversely, control group had insignificantly higher post-inspection scores (excluding all scores of sex-related knowledge and scores of atttitude against sex including psychological development and pregnancy). Conclusions: Our study suggested that sexuality education in elementary school have an impact on forming knowledge, attitude, and role identity regarding the sex.

  • PDF

Comparative Analysis of the Prerequisite Items Applicable to the HACCP in Livestock Processing Plants (축산물가공장 HACCP 선행요건 평가항목 개선을 위한 비교분석)

  • Hong, Chong-Hae;Cho, Da-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 2008
  • We analyze the HACCP Prerequisites of National Veterinary Research and Quarantine Service (NVRQS), Korea Food and Drug Administration(KFDA), and US Food Safety and Inspection Service (FSIS) and recommend contents and ranges to be complemented and used for the preparation of guidelines. We used the HACCP Notice of the Processing Livestock Act, the HACCP Application Manual for Livestock Processing Plants, the HACCP Notice of the Food Sanitation Act, US GPO 9 CFR and 21 CFR, US FSIS Directive 11,000.1, and HACCP-based Inspection reference guide of Consumer Services, North Carolina Department of Agriculture. The Prerequisites of NVRQS and KFDA are composed of 66 and 84 items respectively, without detailed guidelines for their application. This may decisively affect the application in the field and the evaluation activities. Water supplies, washing and disinfection monitoring tools, and examining and correcting plan are required to be improved. If the standards of compliance of each Prerequisite item as well as performance guidelines are given, the application and evaluation will be performed more effectively. The evaluation items should be associated with Prerequisite operations such as non-compliance complement, self-evaluation, and record keeping. Hazards found during official inspection should be promptly controlled not to contaminate the work places and processing items. As the HACCP is expected to spread from farms to tables, the standardized Prerequisite program among the official governments should be prepared.

A Study on the Priority of 『Personal Information Safety Measure』 Using AHP Method: Focus on the Defferences between Financial Company and Consignee (AHP 기법을 이용한 금융회사 『개인정보의 안전성 확보조치 기준』 우선순위에 관한 연구: 금융회사 위·수탁자 간 인식 차이를 중심으로)

  • KIM, Seyoung;KIM, Inseok
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.4
    • /
    • pp.31-48
    • /
    • 2019
  • To survive in the trend of the fourth industrial revolution, companies are putting a lot of attention and effort into personalization services using the latest technologies such as big data, artificial intelligence and the Internet of Things, while entrusting third parties to handle personal information on the grounds of work efficiency, expertise and cost reduction. In such an environment, consignors need to check trustees on a more effective and reasonable basis to ensure personal information safety for trustees. This study used AHP techniques to derive the importance and priority of each item of "Personal Information Safety Assurance Measures" for financial companies and trustees, and objectively compared and analyzed differences in perceptions of importance between financial institutions and trustees. Based on this, the company recognizes the difference between self-inspection of financial institutions and inspection of trustees and presents policy grounds and implications for applying differentiated inspection standards that reflect the weights appropriate for the purpose.

Pool proof safety through the old apartments redesigned to ensure safety study (노후아파트 안전관리를 통한 풀 푸르프 재설계로 안전성 확보에 관한 연구)

  • Baek, Dong Seung;Lee, Jong Hyun;Park, Sung Bong
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.280-287
    • /
    • 2018
  • Purpose: The study is based on comparative review of the actual inspection of apartments and aims at proposing easy accessible and useful safety control which is enhanced from pre-existing safety apparatus. Method: On the basis of preceding research data of apartment buildings, the study presents reported problems and real condition of apartment buildings based on Housing Related Legislation and Housing Act. Results: Safety management plans and safety inspection for buildings are needed. When conducting a safety check, traceability management system for internal/exterior facilities should be available. Most important of all, 24 hour a day of self-management system for elevators, fire protection, and security cameras is necessary. Conclusion: Through the study, there should be a process of confirming problems of building security management; such as checking the management condition through apartments' resident representatives, and seeking improvement measures.

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".