• 제목/요약/키워드: selective sensitivity

검색결과 192건 처리시간 0.028초

급, 만성 요천추부 신경근병증 환자의 신체진찰과 근전도의 임상적 의미 (Clinical Value of Physical Examination and Electromyography in Acute and Chronic Lumbosacral Radiculopathy)

  • 정유형;정하목;강석;윤준식
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.90-96
    • /
    • 2020
  • Objective: To investigate the diagnostic accuracy of two physical examinations (straight leg raise [SLR] and Bragard test) and electromyography (EMG) in patients with lumbosacral monoradiculopathy in acute and chronic state on confirmation of different diagnostic criteria (MRI vs MRI and diagnostic selective nerve root block [DSNRB]). Method: We identified 297 participants retrospectively from the departmental database. MRI evidence of L5 or S1 nerve root compression and a positive result in diagnostic SNRB served as reference standards. They were divided into two groups by the symptom duration: lasting more than 12 weeks in the chronic group and less than 12 weeks in the acute group. The diagnostic value of clinical tests and EMG were compared. Results: The clinical tests (SLR and Bragard test) done in acute stage on detection by MRI and DSNRB had the highest sensitivity (68%) compared to the chronic stage (63%), but sensitivity was low (57%) on confirmation of MRI alone. However, there was no significant difference on sensitivity and specificity of EMG regardless of reference standards and symptom duration. Electromyography was a significant predictor of neuropathic abnormalities on both acute (OR, 6.3; 95% CI, 2.4 to 16.7; p<0.01) and chronic (OR, 6.8; 95% CI, 2.9 to 16.3; p<0.01). Conclusion: In general, individual physical tests are easy to do and a combination of those tests could be a sensitive indicator of L5 or S1 radiculopathy. Furthermore, the use of provocation tests could provide useful information, especially in proceeding therapeutic selective nerve root block.

선로정수에 대한 선택적인 고유치감도 기법의 개발 (Development of Selective Eigen-Sensitivity Techniques for Line Parameter)

  • 심관식;남해곤;김용구;송성근;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1299-1301
    • /
    • 1999
  • This paper describes a initial screening methods for weak line selection using sensitivity matrix. The elements of sensitivity matrix for line suceptance have 1 or -1, 0. From this property of sensitivity matrix, the eigen-sensitivity for line suceptance can be computed very simply and selected weak line for small signal stability or transient stability. The proposed algorithm is applied to small signal stability of New England 39-bus system and also applied to voltage stability of New England 30-bus system too.

  • PDF

PCR을 이용한 육류 내 Campylobacter sp. 및 Campylobacter jejuni의 분리 검출 (Selective Detection of Campylobacter sp. and Campylobacter jejuni in Meat Food by Polymerase Chain Reaction)

  • 주종원;홍경포;김용휘;조상범
    • 동아시아식생활학회지
    • /
    • 제18권5호
    • /
    • pp.753-759
    • /
    • 2008
  • 본 연구는 식품 샘플에서 단시간 내에 간단한 방법으로 Campylobacter jejuni를 검출하기 위하여 10가지의 Campylobacter genus-specific primer와 C. jejuni species-specific oligonucleotide를 제작하였고, amplification efficiency test를 통하여 4종으로 축소한 후 다시 specificity, sensitivity analysis를 통하여 최종적으로 CB4, CJ1 2종의 oligonucleotide primer를 선별하였다. 선별된 oligonucleotide primer는 각각 Campylobacter genus specific, Campylobacter jejuni에 대한 species specific한 특성을 지닌다. 또한, sensitivity analysis를 통하여 isolated colony에서 reaction tube당 $10^0{\sim}10^1$까지의 detection limit을 확보하였다. 육류 시료에서는 Sensitivity가 $10^1{\sim}10^2$으로 떨어지는 양상을 보였으며, 이는 쇠고기나 돼지고기에 존재하는 hemoglobin이나 immunoglobulin 등의 PCR inhibitor의 영향에 의한 것으로 추정된다.

  • PDF

Biologically-Inspired Selective and Sensitive Trinitrotoluene Sensors Using Conjugated Lipid-like Polymer Nanocoatings for CNT-FET Sensors

  • Jaworski, Justyn;Kim, Tae-Hyun;Yokoyama, Keisuke;Chung, Woo-Jae;Wang, Eddie;Lee, Byung-Yang;Hong, Seung-Hun;Majumdar, Arun;Lee, Seung-Wuk;Kwon, Ki-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.495-495
    • /
    • 2011
  • Miniaturized sensors capable of both sensitive and selective real-time monitoring of target analytes are tremendously valuable for various applications ranging from hazard detection to medical diagnostics. The wide-spread use of such sensors is currently limited due to insufficient selectivity for target molecules. We developed selective nanocoatings by combining trinitrotoluene (TNT) receptors bound to conjugated polydiacetylene (PDA) with single-walled carbon nanotube-field effect transistors (SWNT-FET). Selective binding events between TNT molecules and phage display derived TNT receptors were effectively transduced to sensitive SWNT-FET conductance sensors through the PDA coating. The resulting sensors exhibited unprecedented 1 fM sensitivity toward TNT in real time, with excellent selectivity over various similar aromatic compounds. Our biomimetic receptor coating approach may be useful for the development of sensitive and selective micro and nanoelectronic sensor devices for various other target analytes.

  • PDF

척추동맥에 근접한 경부 자창 1례 (A Cervical Stab Wound Near Vertebral Artery : A Case Report)

  • 주영훈;김종훈;김민식;선동일
    • 대한기관식도과학회지
    • /
    • 제13권2호
    • /
    • pp.57-60
    • /
    • 2007
  • The management of penetrating zone II neck injuries without hard signs of vascular injury has been controversial. The controversy lies between mandatory exploration and a selective approach to the management of theses injuries. Authors that advocate mandatory exploration state its low complication rate and high sensitivity in support of this approach. Surgeons in support of selective management argue selective management has comparable efficacy with lower morbidity in comparison with mandatory exploration. Recently we experienced a case of stab wound near vertebral artery and operatively explored, therefore we report a case along with review of literature.

  • PDF

Reconfigurable Selective Harmonic Elimination Technique for Wide Range Operations in Asymmetric Cascaded Multilevel Inverter

  • Kavitha, R;Rani, Thottungal
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1037-1050
    • /
    • 2018
  • This paper presents a novel reconfigurable selective harmonic elimination technique to control harmonics over a wide range of Modulation Indexes (MI) in Multi-Level Inverter (MLI). In the proposed method, the region of the MI is divided into various sectors and expressions are formulated with different switching patterns for each of the sectors. A memetic BBO-MAS (Biogeography Based Optimization - Mesh Adaptive direct Search) optimization algorithm is proposed for solving the Selective Harmonic Elimination - Pulse Width Modulation (SHE-PWM) technique. An experimental prototype is developed using a Field Programmable Gate Array (FPGA) and their FFT spectrums are analyzed over a wide range of MI using a fluke power logger. Simulation and experimental results have validated the performance of the proposed optimization algorithms and the reconfigurable SHE-PWM technique. Further, the sensitivity of the harmonics has been analyzed considering non-integer variations in the magnitude of the input DC sources.

개량된 Bifidobacterium의 선택배지 개발 (Improved Selective Medium for Isolation and Enumeration of Bifidobacterium sp.)

  • 지근억;이세경;김인희
    • 한국식품과학회지
    • /
    • 제26권5호
    • /
    • pp.526-531
    • /
    • 1994
  • 한국인의 장내 균총 조사를 하던 중 Bifidobacterium 선택배지로 개발된 Mitsuoka의 BS배지에서 상당수의 Bifidobacterium이 사멸되는 것으로 나타났다. 이에 보다 개량된 Bifidobacterium의 선택배지를 조제하기 위하여 한국인들로부터 Bifidobacterium들을 비선택 배지및 기존의 선택배지에서 분리한 뒤 동정하였다. 분리 동정된 균주들에 대하여 항생제와 대사저해제에 대한 감수성 조사 및 특이 기질검사를 하여 선택배지 조제의 기초 자료로 활용하여 Bifidobacterium이 선택적으로 자랄 수 있는 배지로 TP배지를 고안하였다 TP배지는 상용되는 Mitsuoka의 BS배지보다 Bifidobacterium 선택성이 우수하였고 colony 성장속도도 빨랐다.

  • PDF

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • 제1권2호
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

Polymeric Lead(II)-selective Electrode Based on N,N'-Bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an Ion Carrier

  • Kim, Hee-Cheol;Lee, Hyo-Kyoung;Choi, A-Young;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.538-542
    • /
    • 2007
  • Polymeric electrodes for lead ion based on N,N'-bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an ion carrier were prepared. The membrane electrode (m-3) containing o-NPOE as a plasticizer and 50 mol% additive of ionophore gives an excellent Nernstian response (29.59 mV/decade) and the limit of detection of ?log a (M) = 5.74 to Pb2+ in Pb(NO3)2 solution at room temperature. The prepared electrode provided good sensitivity and outstanding selectivity and response for Pb2+ over a wide variety of other metal ions in pH 7.0 buffer solutions. The good sensitivity and selectivity towards lead ion are attributed to the strong complexation of lead ion to N,N'-bis-thiophen-2-ylmethylene-pyridine-2,6-diamine which has geometrically the proper cavity to coordinate to the ligand.

Nano-Scale Immobilization of Antibody for the Construction of Immunosensor

  • Cho, Il-Hoon;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.701-705
    • /
    • 2003
  • Performance of an immunosensor can usually be assessed in terms of its analytical sensitivity and specificity. Sensitivity, i.e., the detection limit of analyte, is particularly determined by the amount of analyte molecules bound to the capture antibody immobilized onto a solid surface. In order to increase the binding complexes, we have investigated an immobilization method of antibody allowing for a molecular arrangement of the protein on a selective surface of a nano-patterned solid substrate. This has not been accomplished only by a surface treatment with a chemical, but also by fragmentation of immunoglobulin. Such approach would offer a protocol of antibody immobilization for the construction of nano-immunosensor and eventually improve the sensitivity of detection.

  • PDF