• 제목/요약/키워드: selective sensitivity

검색결과 192건 처리시간 0.026초

수경재배 시 다량 이온 농도 측정을 위한 이온 선택성 전극의 응용 (Application of Ion-Selective Electrodes to Measure Ionic Concentrations of Macronutrients in Hydroponics)

  • 김민수;박두산;조성인
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.37-43
    • /
    • 2007
  • This study was carried out to investigate the applicability of PVC membrane-based ion-selective electrodes for macronutrients (K, Ca, and N) by measuring of potassium, calcium, nitrate ions in hydroponic nutrient solution. The capabilities of two ion-selective membranes with varying chemical compositions for each ion were evaluated in terms of sensitivity, selectivity, and lifetime to choose sensing elements suitable for measuring typical ranges of nutrient concentrations in hydroponic solutions. The selected calcium and nitrate ion-selective membranes showed effectively sensitive responses to calcium and nitrate ions with lifetimes of 25 and 15 days, respectively. The addition of a cation additive to the potassium membrane cocktail allowed its sensitivity to be increased whereas its lifetime was reduced from 30 days to 10 days.

선택적 주의 관점에서 본 조명에 의한 주의 자원과 공간 기억의 변화 (The Change of 'Attention Resources' and 'Space-Memory' by Lighting focusing on 'Selective Attention)

  • 서지은
    • 한국실내디자인학회논문집
    • /
    • 제25권2호
    • /
    • pp.41-49
    • /
    • 2016
  • The purpose of this study is to analyze the change and to compare to the difference of 'selective elements' and 'space-memory' focusing on the theory, 'selective attention' through the survey results. In this study, In this study, the lighting is considered a important factor in the change of 'selective elements'. this survey is to find the selective elements of participants and to measure the spatial sensitivity of respondents through 'self- test'. The analysis in this study is conducted by descriptive statistics, t-test and one way ANOVA by SPSS program 22. The results of this study are as following; Firstly, 'attention-element' could be classified with 4 types, 'shape', 'material', 'contrast' and 'combination'. 'shape' could divide into 'structure' and' furniture and object'. In case of 'material', it could section with 'pattern' and 'color'. Secondly, through the results of study, 'attention-element' is different each space during the day in detail. But we could know that 'shape' is the important element of the 'attention-elements' during the day through comparison of this result. That means users consider this as a important factor when they evaluate the space. Therefore, it is effective way designers to consider 'shape' as the first element when they want to conduct the special sensitivity of users in the space through planning. On the other hand, what selective elements of users are different by the lighting situation should be acknowledged by designers. And they should think the kinds of selective elements are more various when lighting turns on than turns off.. Thirdly, through the results such as the meaningful difference of space-memory of users according to the change of 'attention-elements', designers should judge about which kind of feeling of users to the space do you want lead in the design process. For the effective feedback between spaces and users to induce the same emotion of users, designers need to consider the unified design and the individual design both. Also, we will regard the differences in the users' emotion to the space according to the lighting situation when we design the space.

식품 유래 대장균군의 발색 배지 분리 효율 비교 (Comparative Evaluation of Selective Chromogenic Media for Coliforms Bacteria Isolated from Food)

  • 이다연;김희언;이진성;김근성;조용선
    • 한국식품위생안전성학회지
    • /
    • 제31권3호
    • /
    • pp.222-225
    • /
    • 2016
  • 식품에서 대장균군을 효율적으로 분리하기 위해 대장균군 선택배지 5종: Chromocult Chromocult coliform agar (Merck), Hicrome coliform agar (Sigma), CHROMagar ECC, Brilliance E.coli/coliform medium (OXOID), endo agar (Merck)을 선별하여 식품 분리 대장균군 83종 및 표준균주 21종에 대해서 민감도와 특이도를 분석한 결과 Chromocult coliform agar와 HICrome coliform agar에서 94%도 민감도가 가장 높았으며, Brilliance E.coli/coliform medium는 93%, CHROMagar ECC는 92%, ENDO agar는 74%의 민감도를 나타냈다. Chromocult coliform agar와 HICrome coliform agar는 대장균군의 회수율도 높았다. 그러므로 Chromocult coliform agar와 HICrome coliform agar는 대장균군을 분리하는데 가장 효율적인 배지로 생각된다.

민들린 평판의 아이소-지오메트릭 형상 설계민감도 해석 (Isogeometric Shape Design Sensitivity Analysis of Mindlin Plates)

  • 이승욱;조선호
    • 한국전산구조공학회논문집
    • /
    • 제26권4호
    • /
    • pp.255-262
    • /
    • 2013
  • 본 논문에서는 아이소-지오메트릭 기법을 기반으로 민들린 후판에 대한 형상 설계민감도 해석법을 제시하였다. 아이소-지오메트릭 기법은 정확한 기하학적 형상의 표현, 요소 사이의 높은 연속성 등 바람직한 강점들을 가지고 있으며 궁극적으로는 해석해로의 빠른 수렴성과 정확한 설계민감도를 제공한다. 선형 형상함수를 사용하는 유한요소법과는 달리 아이소-지오메트릭 기법에서는 높은 차수의 NURBS 기저함수를 활용하여 CAD 형상의 법선벡터와 곡률을 정확하게 고려한다. 전단 잠김(Shear locking) 현상을 극복하기 위해서 선택적 감소적분(Selective reduced integration) 기법을 사용하였다. 이 간단한 방법은 복잡한 정식화 과정 없이 정확한 아이소-지오메트릭 형상 설계민감도 해석을 수행한다. 굽힘 문제에 대한 수치예제를 통하여 제안된 아이소-지오메트릭 해석과 유한요소 해석을 비교하였으며, 유한차분 설계민감도와 비교하여 아이소-지오메트릭 형상 설계민감도는 매우 정확함을 확인하였다.

Transceiver for Human Body Communication Using Frequency Selective Digital Transmission

  • Hyoung, Chang-Hee;Kang, Sung-Weon;Park, Seong-Ook;Kim, Youn-Tae
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.216-225
    • /
    • 2012
  • This paper presents a transceiver module for human body communications whereby a spread signal with a group of 64 Walsh codes is directly transferred through a human body at a chip rate of 32 Mcps. Frequency selective digital transmission moves the signal spectrum over 5 MHz without continuous frequency modulation and increases the immunity to induced interference by the processing gain. A simple receiver structure with no additional analog circuitry for the transmitter has been developed and has a sensitivity of 250 ${\mu}V_{pp}$. The high sensitivity of the receiver makes it possible to communicate between mobile devices using a human body as the transmission medium. It enables half-duplex communication of 2 Mbps within an operating range of up to 170 cm between the ultra-mobile PCs held between fingertips of each hand with a packet error rate of lower than $10^{-6}$. The transceiver module consumes 59 mA with a 3.3 V power supply.

게이팅 스프링 가설을 적용한 전정기관 유모세포의 반강성 메커니즘 모델 (Modeling Negative Stiffness Mechanism of Vestibular Hair Cell by Applying Gating Spring Hypothesis to Inverted Pendulum Array)

  • 임고은;박수경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.405-408
    • /
    • 2007
  • Vestibular hair cells, the sensory receptors of vestibular organs, selectively amplify miniscule stimuli to attain high sensitivity. Such selective amplification results in compressive nonlinear sensitivity, which plays an important role in expanding dynamic range while ensuring robustness of the system. In this study, negative stiffness mechanism, a mechanism responsible for the selective amplification by vestibular hair cells, is applied to a simple mechanical system consisting of an array of inverted pendulums. The structure and working principle of the system have been inspired by gating spring hypothesis proposing that opening and closing of transduction channels contributes to the global stiffness of vestibular hair bundle. Parameter study was carried out to analyze the effect of each parameter on the compressive nonlinearity of suggested model.

  • PDF

Design and Synthesis of Metallopeptide Sensors: Tuning Selectivity with Ligand Variation

  • Kim, Joung-Min;Joshi, Bishnu Prasad;Lee, Keun-Hyeung
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권9호
    • /
    • pp.2537-2541
    • /
    • 2010
  • We chose a fluorescent pentapeptide sensor (-CPGHE) containing a dansyl fluorophore as a model peptide and investigated whether the selectivity and sensitivity of the peptides for heavy and transition metal ions could be tuned by changing amino acid sequence. In this process, we developed a selective peptide sensor, Cp1-d (-HHPGE, $K_d\;=\;670\;nM$) for detection of $Zn^{2+}$ in 100% aqueous solution and a selective and sensitive peptide sensor, Cp1-e (-CCHPGE, $K_d\;=\;24\;nM$) for detection of $Cd^{2+}$ in 100% aqueous solution. Overall results indicate that the selectivity and sensitivity of the metallopeptide sensors to specific heavy and transition metal ions can be tuned by changing amino acid sequence.

Development of Nested PCR Primer Set for the Specific and Highly Sensitive Detection of Human Parvovirus B19

  • Cho, Kyu-Bong
    • 대한의생명과학회지
    • /
    • 제24권4호
    • /
    • pp.390-397
    • /
    • 2018
  • For the specific detection of human Parvovirus B19 (HuPaV-B19), we designed ten specific PCR primers from 3,800~4,500 nucleotides of HuPaV-B19 complete genome (NC_000883.2). Seventeen candidate PCR primer sets for specific detecting HuPaV-B19 were constructed. In specific reaction of HuPaV-B19, seventeen PCR primer sets showed specific band, however five PCR primer sets were selected basis of band intensity, amplicon size and location. In non-specific reaction with seven reference viruses, four PCR primer sets showed non-specific band, however one PCR primer set is not. Detection sensitivity of final selective PCR primer set was $100fg/{\mu}L$ for 112 minute, and PCR amplicon is 539 base pairs (bp). In addition, nested PCR primer set was developed, for detection HuPaV-B19 from a low concentration of contaminated samples. Selection of nested PCR primer set was basis of sensitivity and groundwater sample tests. Detection sensitivity of final selective PCR and nested PCR primer sets for the detection of HuPaV-B19 were $100fg/{\mu}L$ and $100ag/{\mu}L$ basis of HuPaV-B19 plasmid, it was able to rapid and highly sensitive detection of HuPaV-B19 than previous reports. We expect developed PCR primer set in this study will used for detection of HuPaV-B19 in various samples.

바이오나노 전자 코 (BionanoElectronic Nose)

  • 김경호;오윤광;권오석
    • 진공이야기
    • /
    • 제5권1호
    • /
    • pp.9-12
    • /
    • 2018
  • Electronic nose has been developed for detection of various hazardous molecules, especially vapor organic compounds (VOCs), by adsorption and desorption phenomenon. However, although conventional electronic noses have provided many advantages such as simple detection and high sensitivity, they still need advanced technologies for selective specificity in real samples. In this review, we provide bionanoelectronic noses with natural receptors for selective odorant detection. This review includes from fabrication of natural receptors and conducting nanomaterials to bioelectronic noses. We also discussed their perspective applications for the future at the conclusion.

Evaluation of the Selective Enrichment Culture to Recover Clostridium difficile

  • An, Byoungrak;Kim, Heejung;Lee, Kyungwon
    • 대한임상검사과학회지
    • /
    • 제46권4호
    • /
    • pp.140-142
    • /
    • 2014
  • To evaluate the recovery rates to increase toxigenic C. difficile, the selective enrichment broth culture methods were compared with commonly used cytotoxin assays and toxigenic culture. First, the enrichment culture, using the selective medium broth for 2 to 5 days, was performed and then, toxigenic C. difficile was confirmed by C. difficile toxin gene-specific PCR after being cultured on C. difficile selective agar. The sensitivity of C. difficile from the enrichment culture (100%) was higher than that of C. difficile selective agar culture (93.8%), while positive predictive values (PPV) were low; 72.7% (16/22) and 88.2% (15/17). PPV of the enrichment culture are not high. Recently, combinations of C. difficile selective agar culture, C. difficile A & B assays, glutamate dehydrogenase, and nucleic acid amplification method are widely used. The enrichment culture was disadvantageous in PPV, turn-around time, and cost. So, what we performed is not considered as a common method of diagnosis of C. difficile-associated diarrhea.