• Title/Summary/Keyword: selective detection

Search Result 576, Processing Time 0.03 seconds

Effects of Some Crude Drug Extracts on the Brain Neurotransmitters in the Ethanol-Treated Rats (수종의 생약 추출물이 에탄올 투여 흰쥐의 뇌 부위별 신경전달물질에 미치는 영향)

  • Linh, Pham-Tuan;Lee, Soon-Chul;Kim, Young-Ho;Hong, Seon-Pyo;Song, Chang-Woo;Kang, Jong-Seong
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.630-635
    • /
    • 2000
  • The concentration of neurotransmitters in rat brain was determined by HPLC-ECD (electrochemical detection) method and the effects of methanol extracts of some crude drugs, such as Polygala Radix, Myristicae Semen, Zizyphi Semen, Acori graminei Rhizoma, Visci Herba, Liriopsis Tuber, Myrrha on the concentration of neurotransmitters in the ethanol-treated rat brain were investigated. By the administration of ethanol, dopamine (DA), 3, 4-dihydroxyphenyl acetic acid (DOPAC) and serotonin (5-HT) levels in frontal cortex and 5-HT level in hippocampus were significantly increased compared with the neurotransmitter levels in the brain of saline-treated rats. The ${\gamma}$-aminobutyric acid (GABA) level in frontal cortex was decreased by the same treatment. There was a tendency that the DA level in frontal cortex and striatum of ethanol-treated rats were increased by the administration of crude drug extracts. Especially, Myrrha and Visci Herba significantly increased the DA level of frontal cortex in ethanol-treated rats, while they significantly decreased the 5-HT level in the same region of the brain. GABA level in striatum of ethanol-treated rats was significantly decreased by Myristicae Semen, Visci Herba and Myrrha. These results suggest that the tested crude drug extracts have selective interaction with neurotransmitters in specified region of central nervous system.

  • PDF

Determination of Amitrole in Water Samples by Evaporation and GC/MS (증발법과 GC/MS를 이용한 수질 시료 중의 Amitrole의 분석법 연구)

  • Yoon, So Hee;Hong, Ji Eun;Pyo, Hee Soo;Park, Song Ja
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.483-487
    • /
    • 2003
  • Amitrole is well-known as a non-selective herbicide and it is able to cause contamination of driking water as well as pollution of ground water and surface water. However, it is difficult to extract from water because it has a high solubility for water whereas a low solubility for general organic solvents. This method is described for the determination of amitrole in water samples by GC/MS. After evaporation of 10 mL water sample by a vacuum evaporator, amitrole was derivatized with isobutyl chloroformate (iso-BCF) on room temperature for 15~20 min. As a result, the sensitivity for GCfMS was improved as N-isobutoxycarbonyl amitrole derivative was formed. The linearity of the calibration curve showed good as 0.997. The recoveries were obtained more than 94.9% and relative standard deviations were less than 2.8% at $1.0{\mu}g/L$, $10.0{\mu}g/L$ and $100.0{\mu}g/L$. The limit of detection showed $0.1{\mu}g/L$ with a signal-to-noise ratio (S/N) of 3.

Differential Pulse Voltammetric Determination of Iron(III) Ion with a Sodium Dodecyl Sulfate Modified Glassy Carbon Electrode (시차펄스전압전류법에서 도데실황산나트륨이 수식된 유리탄소전극에 의한 선택성 있는 철(III) 이온의 정량)

  • Ko, Young Chun;Kim, Jin Ah;Chung, Keun Ho
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.427-432
    • /
    • 1997
  • A selective method for the determination of iron(III) ion with a sodium dodecyl sulfate(SDS) modified glassy carbon electrode was proposed. It was based on the electrostatic attraction and complexation of the SDS modifier, $(DS^-)_n-Fe^{3+}$. The determination of iron(III) ion was performed by a differential pulse voltammetry(DPV), and the reduction peak potential of $(DS^-)_n-Fe^{3+}$ was +0.466(${\pm}0.002$)V vs. Ag/AgCl. For the determination of iron(III) ion, a linear calibration curve was obtained within the iron(III) ion concentration range of $0.50{\times}10^{-5}{\sim}10{\times}10^{-5}mol/L$, and the detection limit was $0.14{\times}10^{-5}mol/L$. $Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$, $Pb^{2+}$, $Zn^{2+}$, and $Mn^{2+}$ showed little or no effect on the determination of iron(III) ion, respectively. But, ion such as each $CN^- $ and $SCN^-$ interfered seriously.

  • PDF

Electrical properties of n-type $WO_{3}$ based gas sensors (N-형 $WO_{3}$계 가스센서의 전기적 특성)

  • Yang, Jong-In;Kim, Il-Jin;Lim, Han-Jo;Han, Sang-Do;Chung, Kwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.188-196
    • /
    • 1998
  • The sensing and electrical characteristics of $WO_{3}$-based n-type semiconductor gas sensors are investigated. In normal air condition, $TiO_{2}$(4 wt. %)-doped $WO_{3}$-based sensor fabricated without any binder shows the grain boundary ( GB ) potential barrier height of 0.26 V. Sensors fabricated with alumina, PVA and silica sol binders show 0.17, 0.22 and 0.26 V of GB potential barrier height, respectively. In the ambience of 120 ppm $NO_{x}$ concentration, the GB potential barrier height of the sensor fablicated without binder is increased to 0.59 V. The sensors were fabricated with alumina, PVA, silica sol binders show 0.43, 0.66 and 0.52 V of potential barrier, respectively. Thus the variation of the potential barrier at GB is largest in the sensor fabricated with the PVA binder. This is found to be the main reason why the sensor fabricated with the PVA binder shows the best sensitivity. It is also found that the decrease of sensitivity at a temperature higher than the optimum operation temperature is due to the temperature dependence of the sensor resistance in normal air condition rather than the desorption of the adsorbed $NO_{x}$ gas particles. In the ambience of 250 ppm CO concentration, the GB potential barrier heights of the sensors fabricated without binder and with PVA binder are about 0.2 V showing negligible change compared to the case of normal air ambience. This fact indicates that these sensors are good candidates for the selective detection of $NO_{x}$ gas in the mixture of CO and $NO_{x}$ gases.

  • PDF

Monitoring of Butyltin Compounds in PVC Food Packaging - Determination of Butyltin Compounds in PVC Wrap and Gasket for Food Packaging by GC/MS (식품용 염화비닐수지제 기구 및 용기.포장 중 부틸주석화합물의 모니터링 - GC/MS를 이용한 염화비닐수지제 식품용 랩 및 가스킷 재질 중 부틸주석화합물 잔류량 분석)

  • Sung, Jun-Hyun;Yoon, Hae-Jung;Choi, Hyun-Cheol;Jeon, Dae-Hoon;Eom, Mi-Ok;Kim, Hyung-Il;Park, Na-Young;Lee, Eun-Joon;Lee, Young-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.715-720
    • /
    • 2007
  • The levels of butyltin compounds in poly(vinyl chloride) (PVC) food packaging using gas chromatography/mass spectrometry (GC/MS) were monitored. The analytical method, involving the ethylation with sodium tetraethylborate, was found to be selective and sensitive for mono-n-butyltin (MBT), di-n-butyltin (DBT), and tri-n-butyltin (TBT), validated by a $0.005\;{\mu}g/mL$ limit of detection (LOD), an $R^2>0.999$ for linearity, and >90% of recovery, respectively. Finally, none of the commercial food wraps and gaskets showed detectable levels of butyltin compounds.

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

A Correlation Study between the Environmental, Personal Exposures and Biomarkers for Volatile Organic Compounds (대기 중 휘발성유기오염물질의 환경, 개인 및 인체 노출의 상관성 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.197-205
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health problem throughout the world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. Personal exposure measurements are needed to evaluate the relationship between microenvironmental concentrations and actual exposures. It is also important to investigate exposure frequency, duration, and intensity, as well as personal exposure characteristics. In addition to air monitoring, biological monitoring may contribute significantly to risk assessment by allowing estimation of absorbed doses, rather than just the external exposure concentrations, which are evaluated by environmental and personal monitoring. This study was conducted to establish the analytic procedure of VOCs in air, blood, urine and exhaled breath and to evaluate the relationships among these environmental media. The subjects of this study were selected because they are occupationally exposed to high levels of VOCs. Environmental, personal, blood, urine and exhalation samples were collected. Purge & trap, thermal desorber, gas chromatography and mass selective detector were used to analyze the collected samples. Analytical procedures were validated with the“break through test”, 'quot;recovery test for storage and transportation”,“method detection limit test”and“inter-laboratory QA/QC study”. Assessment of halogenated compounds indicted that they were significantly correlated to each other (p value < 0.01). In a similar manner, aromatic compounds were also correlated, except in urine sample. Linear regression was used to evaluate the relationships between personal exposures and environmental concentrations. These relationships for aromatic and halogenated are as follows: Halogen $s_{personal}$ = 3.875+0.068Halogen $s_{environmet}$, ($R^2$= .930) Aromatic $s_{personal}$ = 34217.757-31.266Aromatic $s_{environmet}$, ($R^2$= .821) Multiple regression was used to evaluate the relationship between exposures and various exposure deter-minants including, gender, duration of employment, and smoking history. The results of the regression model-ins for halogens in blood and aromatics in urine are as follows: Halogen $s_{blood}$ = 8.181+0.246Halogen $s_{personal}$+3.975Gender ($R^2$= .925), Aromatic $s_{urine}$ = 249.565+0.135Aromatic $s_{personal}$ -5.651 D.S ($R^2$ = .735), In conclusion, we have established analytic procedures for VOC measurement in biological and environmental samples and have presented data demonstrating relationships between VOCs levels in biological media and environmental samples. Abbreviation GC/MS, Gas Chromatography/Mass Spectrometer; VOCs, Volatile Organic Compounds; OVM, Organic Vapor Monitor; TO, Toxic Organicsapor Monitor; TO, Toxic Organics.

Pharmacokinetic/Pharmacodynamic Analysis of Metoprolol in Dogs (실험견에서 Metoprolol 약리효과의 약동/력학적 검토)

  • Oh, Dong-Jin;Jang, In-Jin;Lee, Kyung-Hun;Yim, Dong-Seok;Kim, Hyung-Kee;Shin, Sang-Goo;Park, Chan-Woong;Shin, Jae-Gook
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.2
    • /
    • pp.251-259
    • /
    • 1995
  • Pharmacokinetics and pharmacodynamics of metoprolol, a selective beta-l blocker, were examined for 360 minutes after intravenous bolus administration of metoprolol to 6 dogs. Plasma concentration and excreted amount in the urine metoprolol were measured by liquid chromatography with fluorescence detection. PR interval and heart rate were measured by ECG monitoring. Blood pressure was monitored through intraarterial catheter in femoral artery and cardiac output by thermodilution method using Swan-Ganz catheter. To analyze the effect site concentration-response relationship, plasma concentration and pharmacological effects were simultaneously fitted to a two pharmacokinetic compartment linked to pharmacodynamic model with NONLIN program. Results are as follows. 1) The plasma concentration of metoprolol after intrvenous injection decreased biexponentially. The terminal half-life estimated was $1.33{\pm}0.40$ hours and the volume of distribution at steady state (Vdss) and the total body clearance were $1.04{\pm}0.4\;L/kg,\;6.55{\pm}2.21\;L/hr$, respectively. The central compartment volume of distribution and peripheral compartment volume of distribution were $0.35{\pm}0.14L/kg\;and\;0.69{\pm}0.34L/kg$. The renal clearance and intercompartment clearance were $0.53{\pm}0.25\;L/min\;and\;0.35{\pm}0.19\;L/min$. 2) Simulated biophase concentration-response curve shows hyperbolic relationship and the estimated concentration-effect relationship was best explained by Emax model when the prolongation of PR interval and the reduction of the heart rate were used as pharmacodynamic parameters. Emax and EC50 were estimated to be $26.3{\pm}4.7\;msec\;and\;88.8{\pm}82.3\;g/ml$ for PR interval, and $48.7{\pm}18.8\;beats/min\;and\;113.5{\pm}78.7\;ng/ml$ for heart rate, respectively. 3) The changes of cardiac output-effect site concentration relationship was best fitted by a linear model and the slope of the relationship was $0.005{\pm}0.003$. Diastolic blood pressure-effect site concentration relationship was also explained by the linear model and the slope of the relationship was $0.038{\pm}0.034$.

  • PDF

A Performance Monitoring System for Heterogeneous SOAP Nodes (이기종 SOAP 노드의 실시간 성능 모니터링 시스템)

  • Lee Woo-Joong;Kim Jungsun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.6
    • /
    • pp.484-498
    • /
    • 2004
  • In this paper. we propose a novel performance monitoring scheme for heterogeneous SOAP nodes. The scheme is basically based on two-level (kernel-level and user-level) packet filtering of TCP flows. By TCP flow, we mean a sequence of raw packet streams on a TCP transaction. In this scheme, we detect and extract SOAP operations embedded in SOAP messages from TCP flows. Therefore, it becomes possible to monitor heterogeneous SOAP nodes deployed on diverse SOAP-based middlewares such as .Net and Apache AXIS. We present two implementation mechanisms for the proposed scheme. The first mechanism tries to identify SOAP operations by analyzing all fragmented SOAP messages on TCP flows. However, a naive policy would incur untolerable overhead since it needs to copy all packets from kernel to user space. The second mechanism overcomes this problem by selectively copying packets from kernel to user space. For selective copying, we use a kernel-level packet filtering method that makes use of some representative TCP flags.(e.g. SIN, FIN and PSH). In this mechanism, we can detect SOAP operations only from the last fragment of SOAP messages in most cases. Finally, we implement a SOAP monitoring system using a component ca]led SOAP Sniffer that realizes our proposed scheme, and show experimental results. We strongly believe that our system will play a vital role as a tool for various services such as transaction monitoring and load balancing among heterogeneous SOAP nodes.

Determinations of Toltrazuril and Toltrazuril Sulfone Levels in Olive Flounder Paralichthys olivaceus Samples Using Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 넙치(Paralichthys olivaceus)시료의 톨트라주릴 및 톨트라주릴 설폰 분석)

  • Hong, Do Hee;Kim, Ah Hyun;Lee, Ka Jeong;Yoon, Minchul;Son, Kwang Tae;Kim, Myoung Sug;Kim, Na Young;Jung, Sung Hee;Jo, Mi Ra
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.5
    • /
    • pp.461-467
    • /
    • 2019
  • Several studies investigating the prevention and treatment of external parasites in farmed olive flounder Paralichthys olivaceus have found that the anticoccidial agent toltrazuril sulfone is an effective antiparasitic. Prior to undertaking a full-scale study, we developed analytical methods to detect the levels of toltrazuril and toltrazuril sulfone in farmed flounder samples using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS). This analysis showed that LC-MS/MS changed the mobile phase and collision energy of toltrazuril and toltrazuril sulfone. This was validated using established conditions. Sample pre-treatment for this process involved extraction with dichloromethane and purification by liquid-liquid extraction in formic acid, acetonitrile, and h-hexane, followed by determination of all compounds by LC-MS/MS. Separation was achieved within 10 min by gradient elution using a Capcell Pak C18 ($3.0{\mu}m$, $100{\times}2.0mm$) analytical column (Shiseido UG 120V) with a mixture of 0.1% (v/v) formic acid and acetonitrile. Multiple reaction monitoring was used for selective detection of toltrazuril and toltrazuril sulfone. This method yields satisfactory results for linearity, precision, and limits of quantification. Therefore, the method established in our study will serve as a basis for further research on parasite control by toltrazuril and toltrazuril sulfone.