• 제목/요약/키워드: selective detection

검색결과 576건 처리시간 0.028초

Naphthalene Trisulfonic Acid 및 Naphthalene Disulfonic Acid을 이용한 음이온 간접자외선흡광검출 이온크로마토그래피 (Ion Chromatography of Anions with Indirect UV-Photometric Detection by using Naphthalene Trisulfonic Acid and Naphthalene Disulfonic Acid as an Eluent)

  • 이광필;전휘경;서현경;권세목;박긍식
    • 분석과학
    • /
    • 제12권2호
    • /
    • pp.111-115
    • /
    • 1999
  • 간접자외선흡광검출 이온크로마토그래피를 7가지 음이온($H_2PO_4^-$, $Cl^-$, $NO_2^-$, $NO_3^-$, $I^-$, $SO_4^{2-}$, $SCN^-$)분리에 적용하였다. 컬럼은 저용량의 강염기성 음이온 교환체를 가진 상용화된 TSK-guardgel QAE-SW (ca. 0.3 meq./g; 4.6 mm i.d${\times}$150 mm)를 사용하였다. 선택적이고 신속한 이온분리방법을 연구하기 위하여 naphthalene trisulfonic acid(NTS) 및 naphthalene disulfonic acid(NDS) 용리액에 대한 분리거동을 조사하였다. 더 나아가, 0.20 mM NTS 용리액에 5% 아세토리트릴을 첨가하여 음용수에 적용한 결과, 양이온과 음이온을 동시에 분리 할 수 있었다.

  • PDF

PVC 포장재에서 식품유사용매와 식품으로 이행되는 알킬페놀 (Migration of Alkylphenols from PVC Food Packaging Materials to Food Simulants and Foods)

  • 이선희;임흥열;신효선
    • 한국식품과학회지
    • /
    • 제33권4호
    • /
    • pp.416-422
    • /
    • 2001
  • 식품포장용 PVC제인 wrap, sheet 및 gasket으로부터 식품 유사용매와 식품으로 이행되는 알킬페놀류를 HPLC와 GC/MSD로 분석하였다. 세 가지 모든 재질에서 7개의 nonyl phenol 이성질체만이 검출되었고 다른 알킬페놀류는 검출되지 않았으며, wrap이 sheet와 gasket보다 그 함량이 높았다. 각 포장재질로부터 수용성 식품유사용매(증류수, 4% acetic acid, 20% ethanol)와 지용성 식품유사용매(n-heptane)에 의한 nonyl phenol의 용출량은 처리온도 $60^{\circ}C$보다는 $95^{\circ}C$에서, 수용성보다는 지용성 식품유사용매에서 각각 많았고, 또한 wrap에서 sheet와 gasket보다 그 양이 많았다. PVC gasket을 사용한 과일쥬스, olefin계 gasket을 사용한 유아용 쥬스, olefin계 병마개를 사용한 음료에서 nonyl phenol이 각각 포장재로부터 이행되었으며, 포장하기 전의 이들 식품에서도 nonyl phenol이 검출되었다.

  • PDF

Urease 저해활성 측정 cuvette assay에 의한 중금속 이온 검출 (Detection of Heavy Metal Ions by the Cuvette Assay Measuring Urease Inhibitory Activity)

  • 김동경;박경림;강은미;박인선;김남수
    • Applied Biological Chemistry
    • /
    • 제46권2호
    • /
    • pp.74-78
    • /
    • 2003
  • Urease 활성이 중금속 이온에 의하여 저해되는 현상을 알아보기 위하여 발색시약을 사용하는 광학적인 방법으로 효소반응에 의한 암모니아 발생량을 측정하였다. 암모니아 농도에 따른 cuvette assay 시의 흡광도 중가는 암모니아 농도 3.0 mg/l 까지 직선성을 보였으며 이 때의 상관계수는 0.998(r)이었다. 중금속 이온에 의한 urease의 저해활성을 알아보기 위하여 기질에 단일 중금속 이온의 농도별 용액을 가하여 흡광도를 측정한 결과 효소의 저해도는 Hg(II)>Pb(II)>Cu(II)>Cd(II)>Zn(II) 이온의 순으로 나타났다. 한 가지의 중금속 이온 농도를 고정하고 다른 중금속 이온을 각기 다른 농도로 가하면서 urease활성을 측정하였을 때 효소의 저해도는 대체로 개별 중금속 이온에 의한 저해의 총합으로 나타났다. 상기의 결과는 본 연구의 방법이 Hg(II) 이온에 대한 선택적 검출법으로서 뿐만 아니라 여러 형태의 시료 중에 존재가능한 중금속 이온들을 정성적으로 판별하는 방법으로 활용될 수 있음을 보여주었다.

우리나라 식물검역 격리재배 시스템과 2005-2012년 실적보고 (Plant quarantine isolated cultivation system in Korea and results of recorded in 2005-2012)

  • 이시원;박정안;이오미;신용길
    • 농업과학연구
    • /
    • 제40권4호
    • /
    • pp.281-287
    • /
    • 2013
  • 우리나라의 격리재배는 102속, 약 250여종의 식물에 대해 실시하고 있으며, 직접경검법, 배양법, 선택배지, 생리생화학, ELISA 및 PCR 검사방법을 사용한다. 2005-2012년, 우리나라에서 수행된 격리재배는 총 8,307건이며 이중 구근류가 5,165건(62.2%)로 가장 많았고, 묘목류가2,119건(25.0%), 종자 796건(9.6%), 삽수 150건(1.8%), 접수 70건(0.8%) 및 기타 7건(0.1%) 이었다. 불합격 사례는 총 413건으로 약 4.97%였고, 발견된 병의 종류는 총 47종으로 나타났다. 종류별로는 바이러스가 27종으로 가장 많은 수를 차지했으며, 곰팡이 16종, 바이로이드 1종, Chromalveolata 1종 및 기타 2종으로 나타났다. 가장 많은 검역건을 올린 병원체는 Arabis mosaic virus (77건), Tobacco rattle virus (70건), Lily symptomless virus (46건), Penicillium expansum (46건)이다.

Generation of Anti-HLA-DR4 Specific Antibodies by Immunization of the Recombinantly Expressed Allelic Subtype-Specific Region of the $HLA-DRB1^*0405$ Molecules

  • Park, Jung-Hyun;Cho, Eun-Wie;Lee, Yun-Jung;Chung, Jin;Hahm, Kyung-Soo;Kim, Kil-Lyong
    • BMB Reports
    • /
    • 제31권2호
    • /
    • pp.111-116
    • /
    • 1998
  • HLA-DR4 is the dominant allele of MHC class II genes in Koreans. In particular, the $DRB1^*0405$ subtype has been reported to be almost exclusively expressed in Far East Asians, and has also been observed to be strongly associated with rheumatoid arthritis in Koreans and the Japanese. Identification of this specific allele has been mainly performed by PCR-based methods, which is often time consuming, costly, and involves tedious procedures such as the isolation of genomic DNA, PCR, and gel electrophoresis. To develop a more convenient tool for screening vast amounts of samples as well as to generate reagents which might also be used in other applications, in this study, antibodies were produced against this specific HLA subtype. By PCR, an allelespecific region covering the ${\beta}1$ domain of $DRB1^*0405$ was amplified and recombinantly expressed in E.coli. Immunization of Lewis rats with the purified protein yielded an allele specific antiserum. Western blot analysis showed the selective detection of the HLA-DR ${\beta}-chain$. Using this antiserum, established cell lines and peripheral blood lymphocytes were analyzed on their HLA haplotype by fluorescence activated flow cytometry. These novel antibodies will provide a powerful tool in the detection and investigation of DR4 alleles.

  • PDF

An Aptamer-Based Electrochemical Sensor That Can Distinguish Influenza Virus Subtype H1 from H5

  • Lee, Jin-Moo;Kim, JunWon;Ryu, Ilhwan;Woo, Hye-Min;Lee, Tae Gyun;Jung, Woong;Yim, Sanggyu;Jeong, Yong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권11호
    • /
    • pp.2037-2043
    • /
    • 2017
  • The surface protein hemagglutinin (HA) mediates the attachment of influenza virus to host cells containing sialic acid and thus facilitates viral infection. Therefore, HA is considered as a good target for the development of diagnostic tools for influenza virus. Previously, we reported the isolation of single-stranded aptamers that can distinguish influenza subtype H1 from H5. In this study, we describe a method for the selective electrical detection of H1 using the isolated aptamer as a molecular probe. After immobilization of the aptamer on Si wafer, enzyme-linked immunosorbent assay (ELISA) and field emission scanning electron microscopy (FE-SEM) showed that the immobilized aptamer bound specifically to the H1 subtype but not to the H5 subtype. Assessment by cyclic voltammetry (CV) also demonstrated that the immobilized aptamer on the indium thin oxide-coated surface was specifically bound to the H1 subtype only, which was consistent with the ELISA and FE-SEM results. Further measurement of CV using various amounts of H1 subtype provided the detection limit of the immobilized aptamer, which showed that a nanomolar scale of target protein was sufficient to produce the signal. These results indicated that the selected aptamer can be an effective probe for distinguishing the subtypes of influenza viruses by monitoring current changes.

Multiplex PCR 기법을 이용한 Salmonella Enteritidis와 S. Typhimurium의 특이적 검출에 관한 연구 (Identification of Salmonella Enteritidis and S. Typhimurium by multiplex polymerase chain reaction)

  • 이우원;이승미;이강록;이동수;박호국
    • 한국동물위생학회지
    • /
    • 제32권2호
    • /
    • pp.147-153
    • /
    • 2009
  • Salmonella species are the most important etiologic agents of food-borne acute gastroenteritis. The most common serotypes isolated from humans are Salmonella enterica serotype Typhimurium (S. Typhimurium) and S. Enteritidis. Traditional detection methods for Salmonella are based on cultures using selective media and characterization of suspicious colonies by biochemical and serological tests. These methods are generally time-consuming and not so highly sensitive. Recently, the polymerase chain reaction (PCR) has been used as a highly sensitive, specific, and rapid test for the presence of pathogenic bacteria. In this study, a multiplex PCR (m-PCR) was used to detect S. Typhimurium and S. Enteritidis. We selected m-PCR target genes, which were the spv (virulence plasmid specific for S. Enteritidis) and sefA (S. Enteritidis fimbrial antigen) genes, fliC (H1-i antigen specific for S. Typhimurium) and a randomly cloned sequence specific for the genus Salmonella. With m-PCR, random sequence was detected from all strains of Salmonella spp, spv and sefA were detected from all strains of S. Enteritidis (100%), and fliC was detected from all strains of S. Typhimurium (100%). This assay indicate that the specificity of the m-PCR make them potentially valuable tools for detection of S. Typhimurium and S. Enteritidis.

전기방사법으로 합성된 SnO2-Cr2O3 복합나노섬유의 이산화탄소 가스감응 특성 (CO2 Sensing Properties of SnO2-Cr2O3 Composite Nanofibers Via Electrospinning Method)

  • 이재형;김재훈;김진영;김상섭
    • 한국표면공학회지
    • /
    • 제50권4호
    • /
    • pp.289-295
    • /
    • 2017
  • Detection of $CO_2$ gas in both indoor and outdoor atmospheres is now becoming an important issue because of greenhouse effect and climate crisis. In this study, gas sensors based on $SnO_2-Cr_2O_3$ composite nanofibers were fabricated by the electrospinning method to detect $CO_2$ gas. The gas sensors showed a response to ppm level of $CO_2$ gas from room temperature to $200^{\circ}C$ while the highest response was observed at $150^{\circ}C$. The gas response is enhanced by the catalytic property of $Cr_2O_3$. Selective $CO_2$ detection is obtained through the chemical reaction of $Cr_2O_3$ to chromium carbonate. All the results suggest the $SnO_2-Cr_2O_3$ composite material is promising for the use of $CO_2$ gas sensors.

이온 이동에 적합한 아크릴고분자 박막의 조성과 수소이온, 수산화이온, 구리이온의 선택적 검출 (Acrylic Polymer Composition Suitable for Ion Delivery and Selective Detection of Proton, and Hydroxyl and Cu(II) Ions)

  • 이다혜;우희정;도정윤
    • 폴리머
    • /
    • 제38권6호
    • /
    • pp.801-808
    • /
    • 2014
  • 광경화 아크릴고분자 필름에서 이온이동에 관한 연구를 하였다. 고분자에 결합된 아민기와 카르복실산 작용기의 함량을 조절하여 수소이온과 수산화이온의 이동에 적합한 필름을 제조하였다. 수소이온 이동 검출을 위해 p-methylred(PMR) 유도체를 사용하였고 수산화이온 검출을 위해 페놀프탈레인 유도체를 합성하여 각각 고분자에 도입하였다. 수소이온의 이동은 아민기의 함량이 많을수록 빠르게 진행되었고 수산화이온은 카르복실산의 함량이 높을수록 빠르게 이동하였다. 수소이온 이동은 필름표면과 내부로 빠르게 진행하였고 PMR 포함 필름의 흡수스펙트럼을 통해 관찰되었다. 산 용액에 감응하는 필름을 사용하여 색상변화의 가역성을 관찰하였고 연속 50회를 실시하는 동안 정확히 재현되었다. 구리(II) 이온은 카르복실산 작용기의 함량이 높은 필름에서 빠르게 이동하였다. 로다민이 도입된 필름에서 구리이온의 배위로 로다민의 고리열림 반응이 진행되었고 광흡수 및 발광특성 측정을 통해 구리이온의 이동을 추적하였다.

GC-MS에 의한 혈중 5-fluorouracil의 정량법 (The Determination of 5-Fluorourasil in Human Plasma by a Gas Chromatography-Mass Spectrometry)

  • 신호상;서배석;오윤숙;박성우
    • 분석과학
    • /
    • 제11권1호
    • /
    • pp.36-41
    • /
    • 1998
  • GC-MS를 이용한 사람의 혈중 5-fluorouracil(5-FU)의 정량법이 연구되었다. 5-FU은 isopropanol-ether(20:80) 혼합용매 10ml로서 추출하였고 pentafluoro-benzylation에 의해 유도체화 하였다. 시료주입은 자동으로 수행하였으며 분리에 사용한 칼럼은 비극성 capillary column이었고 검출은 MSD로 하였다. 위의 조건하에서 내인성 물질들의 방해현상은 없었고 검출한계는 0.5 ml의 혈액시료를 사용하였을 때 3 ng/ml이었으며 추출효율은 80%이상을 나타냈다. 5-FU로 항암치료를 받는 환자의 시료 500개중에 혈중 5-FU의 농도 측정에 적용하였으며 이 방법이 우수한 monitoring법임을 알 수 있었다.

  • PDF