• Title/Summary/Keyword: selective detection

Search Result 576, Processing Time 0.032 seconds

Highly ordered In2O3 zig-zag nanocolumns for selective detection of acetone (아세톤의 선택적 감지를 위한 In2O3 zig-zag nanocolumns)

  • Jae Han Chung;Ho-Gyun Kim;Yun-Haeng Cho;Junho Hwang;See-Hyung Park;Sungwoo Sohn;Su Bin Jung;Eunsol Lee;Kwangjae Lee;Young-Seok Shim
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.1
    • /
    • pp.38-48
    • /
    • 2024
  • We fabricated In2O3 zig-zag nanocolumns(ZZNCs) by oblique angle deposition method based on e-beam evaporator for highly sensitive and selective CH3COCH3 sensor. Our results indicate that as the ZZNCs layer stacks, the gas response also increases. In comparison to thin films, ZZNCs at 5 layer show a 117-fold enhancement in gas response and a rapid response time (~2 s). When measured with various gases, it showed a high selectivity towards acetone. Under conditions of 80% R.H., exposure to CH3COCH3 gas theoretically indicated a detection limit of 1.2 part-per-billion(ppb). These results suggest the potential of In2O3 ZZNCs as a breath analyzer for the diagnosis of diabetes.

Memory-Free Skin-Detection Algorithm and Implementation of Hardware Design for Small-Sized Display Device (소형 DISPLAY 장치를 위한 비 메모리 피부 검출 알고리즘 및 HARDWARE 구현)

  • Im, Jeong-Uk;Song, Jin-Gun;Ha, Joo-Young;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1456-1464
    • /
    • 2007
  • The research of skin-tone detection has been conducting continuously to enlarge the importance in security, surveillance and administration of the information and 'Password Control System' for using face and skin recognition in airports, harbors and general companies. As well as tile rapid diffusion of the application range in image communications and an electron transaction using wide range of communication network, the importance of the accurate detection of skin color has been augmenting recently. In this paper, it will set up the boundaries of skin colors using the information of Cb and Cr in YCbCr color model of human skin color which is from hundreds compiled portrait images for each race, and suggest a efficient yet simple structure about the skin detection which has been followed by whether the comprehension of the boundaries of skin or not with adaptive skin-range set. With the possibility of the 1D Processes which does not use any memory, it is able to be applied to relatively small-sized hardware and system such as mobile apparatuses. To add the selective mode, it is not only available the improvement of tie skin detection, but also showing the correspondent results about previous face recognition technologies using complicated algorithm.

Memory in visual search: Evidence from search efficiency (시각 탐색에서의 기억: 탐색 효율성에 근거한 증거)

  • Baek Jongsoo;Kim Min-Shik
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • Since human visual system has limited capacity for visual information processing, it should select goal-relevant information for further processing. There have been several studies that emphasized the possible involvement of memory in spatial shift of selective attention (Chun & Jiang, 1998, 1999; Klein, 1988; Klein & MacInnes, 1999). However, other studies suggested the inferiority of human visual memory in change detection(Rensink, O'Regan, & Clark, 1997; Simons & Levin, 1997) and in visual search(Hotowitz & Wolfe, 1998). The present study examined the involvement of memory in visual search; whether memory for the previously searched items guides selective attentional shift or not. We investigated how search works by comparing visual search performances in three different conditions; full exposure condition, partial exposure condition, and partial-to-full exposure condition. Revisiting searched items was allowed only in full exposure condition and not in either partial or partial-to-full exposure condition. The results showed that the efficiencies of attentional shift were nearly identical for all conditions. This finding implies that even in full exposure condition the participants scarcely re-examined the previously searched items. The results suggest that instant memory can be formed and used in visual search process. These results disagree with the earlier studies claiming thar visual search has no memory. We discussed the problems of the previous research paradigms and suggested some alternative accounts.

  • PDF

The Effect of Apple Tree Growth and Apple Yield from the Misuse of Non Selective Herbicide, Glufosinate-ammonium (비선택성 제초제 Glufosinate-ammonium 오용이 사과나무의 품종별 생육반응 및 수확에 미치는 영향)

  • Lee, In-Yong;Park, Yong-Seog;Kim, Sung-Min;Kang, Cheol-Ah;Chun, Byeong-Chul;Park, Jae-Eup
    • Korean Journal of Weed Science
    • /
    • v.30 no.4
    • /
    • pp.454-459
    • /
    • 2010
  • This study was conducted to investigate the phytotoxic reaction and the impact on the growth of apple fruit included the yield amount by misuse of non-selective herbicide, glufosinate-ammonium in apple field and for the study, 4 cultivars of apple were tested. The results showed that the highest phytotoxic degree was observed on Sansa-cultivar and then the degree was diminished on Tsugaru, Hongro and Fuji in order in the application year. In one year after application, the highest phytotoxic degree was showed on Fuji and then diminished on Tsugaru, Hongro and Sansa in order. However, in one year after application, the phytotoxic symptom was negligible in comparison with the degree in the year of application and the flowering and fruiting were reduced 30% only in Fuji, but in the other cultivars, the phytotoxic symptoms were not observed. Meanwhile, the residue of glufosinate-ammonium was below the detection limit as 0.04ppm in all tested cultivars and in 2years after application, the phytotoxic symptom was not observed in all cultivars of the apple.

Production of Monoclonal Antibodies against Vibrio parahaemolyticus and Development of High Sensitive Immuno-Selective Filtration Method (Vibrio parahaemolyticus에 대한 단클론성 항체 개발과 고감도 면역선택여과법의 개발)

  • Kim, Jeong-Sook;Choi, Young-Dong;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • The objectives of this study are to produce monoclonal antibodies (MAbs) against Vibrio parahaemolyticus and to develop an immuno-selective filtration (ISF) method for the rapid and sensitive detection of V. parahaemolyticus. The characterization of the MAb produced from HKVP 4H9-9 hybridoma cell was validated by enzyme-linked immunosorbent assay (ELISA) and western blot. The produced MAb was specific to V. parahaemolyticus and showed weak cross-reaction to V. alginolyticus, V. vulnificus and Staphylococcus aureus. After optimization of the method, $5{\times}10^1cell/mL$ of V. parahaemolyticus in a pure culture could be detectable. Although weak cross-reactivity to V. vulnificus, V. alginolyticus and Staphylococcus aureus was observed, the ISF was confirmed to be highly specific to V. parahaemolyticus. Especially, the ISF showed the most sensitivity compared to the immunoassays currently reported is easier to perform and quicker than ID-ELISA.

Amplified fragment length polymorphism fingerprinting analysis of Staphylococcus aureus isolated from bovine mastitis milk (소 유방염 유래 Staphylococcus aureus의 AFLP 지문분석)

  • Kim, Yeon-soo;Kim, Sang-kyun;Hwang, Eui-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.157-165
    • /
    • 2001
  • Amplified fragment length polymorphism(AFLP) technique is based on the polymorphism detection through selective PCR amplification of restriction fragments from digested genomic DNA and thus includes the procedures of the total DNA digestion by endonucleases, ligation of adapters to the ends of the fragments, and following the selective amplification of the restricted DNA fragments. This study were aimed to : (1) determine the genetic variability of S aureus strains, (2) estimate genetic diversity within and among these strains, (3) compare phylogenetic relationships among these strains as genetic markers using AFLP techniques. Genomic DNA was digested with a particular combination of three restriction enzymes with specific recognition sites and the DNA fragments were ligated to restriction specific adapters and amplified using the selective primer combinations. In the S aureus strain, the number of scorable AFLP bands detected per each primer combination varied from 29 to 102, with an average of 61.59 using 27 primer combinations. A total of 1,663 markers were generated, 904 bands of which were polymorphic, showing a 33.48% level of polymorphism with these primer combinations. Among the primer combinations, E02/T02, E02/T03, E04/H02, E02/T01 and E04/H03 primer combinations showed a high level of polymorphism with 0.78, 0.76, 0.74, 0.71 and 0.70, respectively. But T03/H01, E01/T02 and E01/T03 primer combinations showed a low level of polymorphism with 0.38, 0.37 and 0.15, respectively, Therefore, the former primer combinations will be the most effective for AFLP analysis of S aureus. In SA1 sub-types the level of polymorphism of S aureus KCTC 1927 was similar to that of S aureus CU 01(0.825) and higher than those of other strains such as S aureus CU 02 (0.715), S aureus KCTC 2199(0.625), S aureus KCTC 1916(0.607) and S aureus KCTC 1621 (0.553). In SA2 sub-types the level of polymorphism of S aureus CU 07 was similar to that of S aureus CU 08(0.935) and higher than those of both S aureus CU 04(0.883) and S aureus CU 05(0.883) and lower than those of S aureus CU 03(0.583). In SA3 subtypes the level of polymorphism of S aureus CU 11 was similar to that of S aureus CU 12(0.913) and lower than that of S aureus CU 15(0.623). The results proved that AFLP marker analysis of S aureus strain could be used to study the epidemiology of mastitis and in addition, common genotype in geographic region could be useful for the development of an effective vaccine or DNA marker for easy diagnosis of mastitis caused by S aureus infection.

  • PDF

K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers (중성운반체를 이용한 K+ 이온선택성 PVC막 전극)

  • Kim, Yong-Ryul;Cho, Kyoung-Sub;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.734-741
    • /
    • 1998
  • Electrode characteristics were studied in the interface between sample solutions and $K^+$ ion selective PVC membrane electrodes containing neutral carriers, dibenzo-18-crown-6(D18Cr6) and valinomycin(Val). The effect of doping of base electrolytes, the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, and concentration variation of sample solution on the response characteristics of electrode such as the measured Nernstian slope, the detection limit, the linear response range, and potentiometric selectivity coefficients, were studied. In order to synthesize the membrane D18Cr6 and Val as neutral carriers were used, and complex between the carrier and $K^+$ ions were used as active materials. PVC membrane electrodes were made of plasticizers (DBP, DOS, and DBS), the base electrolyte[potassium tetraphenylborate(KTPB)], and solvent(THF). The chemical structure of carrier D18Cr6 was best for electrode and ideal electrode characteristics were appeared especially in case of doping of TPB. The optimum carrier content was about 3.23 wt % in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the electrode characteristics was improved. But its characteristics were lowered below the optimum membrane thickness because of the elution of carrier, deterioration of membrane strength, etc. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were in the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

PN code Acquisition Method Using Array Antenna Systems for DS/CDMA (DS/CDMA 배열 안테나 시스템에서 PN 동기 획득 방법)

  • Cho, Hui-Nam;Choi, Seung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.196-199
    • /
    • 2004
  • This paper presents a structure of the searcher using the space diversity in array antenna system operating in the DS/CDMA signal environments. The new technique exploits the fact that the In-phase and Quadrature components of interferers can respectively be viewed as independent Gaussian noise at each antenna element in most practical CDMA (Code Division Multiple Access) signal environments. The proposed PN acquisition scheme is a single dwell serial PN acquisition system consisting of two stage, that is, the searching stage and the verification stage. The searching stage correlates the received signals with the local PN oscilator for obtaining the synchronous energy at the entire uncertainty region. The verification stage compares the searching energy with the optimal threshold, which is pre-designed in the Lock-Detector, and decides whether the acquisition is successful or fail. In this paper, we analyzed the relationship of both diversity order and the mean acquisition time. In general, It is known that the mean acquisition time decreases significantly as the number of antenna elements increases. But, the enhancement of the performance is saturated in terms of PN acquisition scheme. Therefore, to decrease the mean acquisition time, we must design the optimal array antenna system by considering the operating SNR range of the receiver, the detection probability, and the false alarm probability. The performance of the proposed acquisition scheme is analyzed in frequency-selective Rayleigh fading channels. In this paper, the effect of the number of antenna elements on acquisition scheme is considered in terms of the detection probability, false alarm probability. and the mean acquisition time.

  • PDF

An Oxalic Acid Sensor Based on Platinum/Carbon Black-Nickel-Reduced Graphene Oxide Nanocomposites Modified Screen-Printed Carbon Electrode

  • Income, Kamolwich;Ratnarathorn, Nalin;Themsirimongkon, Suwaphid;Dungchai, Wijitar
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.416-423
    • /
    • 2019
  • A novel non-enzymatic oxalic acid (OA) sensor based on the platinum/carbon black-nickel-reduced graphene oxide (Pt/CBNi-rGO) nanocomposite is reported. The nanocomposites were prepared by the ethylene glycol reduction method. Their morphology and chemical composition were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and transmission electron microscopy (TEM). The results clearly demonstrated the formation of the Pt/CB-Ni-rGO nanocomposite. The electrocatalytic activity of the Pt/CB-Ni-rGO electrode was investigated by cyclic voltammetry. It was determined that the appropriate amount of Pt enhanced the catalytic activity of Pt for oxalic acid electro-oxidation. Moreover, the modified electrode was determined to be highly selective for oxalic acid without interference from compounds commonly found in urine including uric acid and ascorbic acid. The chronoamperometric signal gave a wide linearity range of 20 μM-60 mM and the detection limit (3σ) was found to be 2.35 μM. The proposed method showed high selectivity, stability, and good reproducibility and could be used with micro-volumes of sample for the detection of oxalic acid. Finally, the oxalic acid content in artificial and control urine samples were successfully determined by our proposed electrode.