• Title/Summary/Keyword: selective detection

Search Result 576, Processing Time 0.027 seconds

Spectrophotometric Investigation of Germanium Complex Solution with o-Chlorophenylfluorone and Determination of Trace Amounts of Germanium

  • Hong-Wen Gao;Wei-Guo Liu
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.11
    • /
    • pp.1090-1094
    • /
    • 2000
  • A reaction between germanium (Ge) and the ligand, o-chlorophenylfluorone (o-CPF) has been carried out. The reaction sensitive at pH 4.5 in the presence of triton x-100 was selective in the presence of EDTA. The spectral correction technique was ap plied to the analysis of the reaction instead of single wavelength spectrophotometry because the absorption of excess of o-CPF was not negligible. An updated determination of the properties of the Ge(IV)-o-CPF complex is given, which involved the complex ratio, stepwise absorptivity and stability constant of the complex. In present work, the results show that the complex $Ge(o-CPF)_3was$ formed and its cumulative stability constant was 1.09 ${\times}$1016 . For sample analysis, the detection limit of germanium was 0.01 mg/L, and the recoveries were between 96.4% and 102%, with relative standard deviations of less than 6.5%.

Breath Gas Sensors for Diabetes and Lung Cancer Diagnosis

  • Byeongju Lee;Jin-Oh Lee;Junyeong Lee;Inkyu Park;Dae-Sik Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Recently, the digital healthcare technologies including non-invasive diagnostics based on Internet of Things (IOT) are getting attention. Human exhaled breath contains a variety of volatile organic compounds (VOCs), which can provide information of malfunctions of the body and presence of a specific disease. Detection of VOCs in exhaled breath using gas sensors are easy to use, safe, and cost-effective. However, accurate diagnosis of diseases is challenging because changes in concentration of VOCs are extremely small and lots of body factors directly or indirectly influence to the conditions. To overcome the limitations, highly selective nanosensors and artificial intelligent electronic nose (E-nose) systems have been mainly researched in recent decades. This review provides brief reviews of the recent studies for diabetes and lung cancer diagnosis using nanosensors and E-nose systems.

Detection of ROIs using the Bottom-Up Saliency Model for Selective Visual Attention (관심영역 검출을 위한 상향식 현저함 모델 기반의 선택적 주의 집중 연구)

  • Kim, Jong-Bae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.314-317
    • /
    • 2011
  • 본 논문은 상향식 현저함 모델을 이용하여 입력 영상으로부터 시각적 주의를 갖는 영역들을 자동으로 검출하는 방법을 제안한다. 제안한 방법에서는 인간의 시각 시스템과 같이 사전 지식 없이 시각정보의 공간적인 분포에 근거하여 장면을 해석하는 상향식 현저함 모델 방법을 입력 영상에 적용하여 관심 물체 영역을 검출하는 연구이다. 상향식 현저함 방법은 Treisman의 세부특징이론 연구에서 제시한 바와 같이 시각적 주의를 갖는 영역은 시각정보의 현격한 대비차이를 가지는 영역으로 집중되어 배경에서 관심영역을 구분할 수 있다. 입력 영상에서 현저함 모델을 통해 3차원 현저함 맵을 생성한다. 그리고 생성된 현저함 맵으로부터 실제 관심영역들을 검출하기 위해 제안한 방법에서는 적응적 임계치 방법을 적용하여 관심영역을 검출한다. 제안한 방법을 관심영역 분할에 적용한 결과, 영역 분할 정확도 및 정밀도가 약 88%와 89%로 제시되어 관심 영상분할 시스템에 적용이 가능함을 알 수 있다.

Synthesis of Novel 18F-Labeled-Nitroimidazole-Based Imaging Agents for Hypoxia: Recent Advances

  • Anh Thu Nguyen;Hee-Kwon Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.83-93
    • /
    • 2023
  • Hypoxia indicates the condition of low oxygen levels in tissues. In oncology, hypoxia can induce cancer progression and metastasis, as well as cause resistance to cancer therapies. The detection of hypoxia by using molecular imaging, particularly, positron emission tomography (PET) has been extensively studied due to many advantages. Nitroimidazoles, the moieties that can be trapped in hypoxic tissues due to selective reduction, have been used to design and synthesize of hypoxia-targeting radiopharmaceuticals. This review provides a summary of synthetic routes towards 18F-labeled-nitroimidazole radiotracers for PET imaging of hypoxia.

Selective Detection of Salmonella sp. and Salmonella Typhimurium in Meat by Polymerase Chain Reaction (PCR을 이용한 육류 내 Salmonella sp. 및 Salmonella Typhimurium 분리 검출)

  • Joo, Jong-Won;Hong, Kyung-Pyo;Kim, Yong-Hui;Cho, Sang-Buem
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.2
    • /
    • pp.295-300
    • /
    • 2009
  • The specificity and sensitivity of oligonucleotide primers were examined for the rapid detection of Salmonella in meat samples. The oligonucleotide primers used in this study were designed with the modification of mdh and invA sequence in the chromosome of Salmonella Typhimurium. Through the subsequent analysis of the specificity and sensitivity of the primers, two types of oligonucleotide primers, SLM1 and SLT4 were selected for the detection of Salmonella genus specific and S. Typhimurium species specific, respectively. The lowest detection limit of each primer was represented as 1 cell per reaction when reacted with a prepared DNA solution. The detection efficiency of the two primers was analysed with beef and pork samples intentionally contaminated with a mixture of Salmonella culture, and three preparation methods -, namely direct reaction after extraction, enrichment after extraction, and DNA extraction after enrichment for PCR reaction, - were also compared. No differences were found in the results according to meat sources and preparation methods.

  • PDF

Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide

  • Ganjali, Mohammad Reza;Norouzi, Parviz;Yousefian, Nasrin;Faridbod, Farnoush;Adib, Mehdi
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1581-1586
    • /
    • 2006
  • A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of $1.0{\times}10^{-2}-1.0{\times}10^{-7}$ M. The detection limit of the electrode is $7.0{\times}10^{-8}$ M ($\sim$10 ng/mL) and the response time is 15 s from $1.0{\times}10^{-2}$ up to $1.0{\times}10^{-4} $M and 30 s in the range of $1.0 {\times}10^{-5}-1.0{\times}10^{-7}$ M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.

Implementation of TCP Retransmitted Packet Loss Recovery using ns-2 Simulator (ns-2 시뮬레이터를 이용한 TCP 재전송 손실 복구 알고리듬의 구현)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.741-746
    • /
    • 2012
  • Transmission control protocol(TCP) widely used as a transport protocol in the Internet includes a loss recovery function that detects and recovers packet losses by retransmissions. The loss recovery function consists of the two algorithms; fast retransmit and fast recovery. There have been researches to avoid nonnecessary retransmission timeouts (RTOs), which leads to selective acknowledgement (SACK) option and limited transmit scheme that are standardized by IETF (Internet Engineering Task Force). Recently, a method that covers the case in which a retransmitted packet is lost again has been propsed. The method, however, is not proved in terms of the additive increase multiplicative decrease (AIMD) principle of TCP congestion control. In this paper, therefore, we analyzed the method in terms of the principle by ns-simulations.

A Comparison of three Enrichment Media for Isolating Salmonella (Salmonella균(菌) 분리용(分離用) 증균배지(增菌培地)의 비교실험(比較實驗))

  • Kim, Yong-Ja;Lee, Seung-Yun;Park, Kee-Deuk;Min, Chang-Hong
    • The Journal of the Korean Society for Microbiology
    • /
    • v.11 no.1
    • /
    • pp.33-48
    • /
    • 1976
  • The practical significance of using a selective enrichment procedure for detecion and enumeration of salmonella is well recognized. There are still various selective enrichment media has been communly used. Early years selenite broth was recomnended as an enrichment media for the isolating of salmonella. Hajna introduced a modified tetrathionate broth and demonstrated the greater efficiency to compare with the previous enrichment media. Raj also described that the new medium called dulcitol selenite enrichment and has been found to be very satisfactory, especially general implication in food poisoning. Authors tried to compare these 3 enrichment media for isolating salmonella. 1. When salmonella strains were inoculated $1{\sim}10^6$ cells per tube to these 3 enrichment media, mostly similar results were obtained between selenite broth and DS broth. In these 2 enrichment broth were showed $10^7/ml-10^8/ml$ cells of all tested salmonella strains. But in the case of TT broth it was found that the growth was $10^3/ml{\sim}10^4/ml$ cells for tested strain. 2. When E. coli, Proteus, Citrobacter were inoculate $10{\sim}10^6$ cells per tube to these 3 enrichment media. It was suggested that DS broth was showed more inhibitory action than that of selenite broth. TT broth showed high inhibition to these 3 organisms tested. 3. It was generally known that the incubation time is influenced to the frequency of salmonella detection. For this tendency, DS broth and selenite broth were showed similar results within 24 hrs to 48hrs incubation to the test. But DS broth showed more inhibitory action to E. coli and Proteus than that of selenite broth. 4. When $1{\sim}10$ cells were inoculated(per tube) to these 3 enrichment media, DS broth was found to be more sensitive than that of selenite broth.

  • PDF

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

Spectrofluorimetric Determination of Pb ion in Aqueous Media Using an Optical Sensor (광센서를 이용한 수용액 중 납이온의 형광분광법적 정량)

  • Lee, Sang Hak;Seo, Hyo Suk
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.407-411
    • /
    • 2002
  • A method to determine lead ion in aqueous media using an optical sensor loaded on a fluorescent optode membrane incoporating a metal ion-selective ionophore, a proton-selective chromoionophore and lipophilic anionic sites has been studied. The effects of pH and thickness of membrane on the fluorescence intensity were investigated. The effects of foreign ions such as $Na^+$, $K^+$, $Mn^{2+}$ and $Zn^{2+}$ on the determination of lead ion were also studied. The linear range in the calibration curve for the determination of lead ion was found to be 5.0${\times}10^-7$ to 5.0${\times}$$10^-3$M and the correlation coefficient in this range was -0.99107 under the optimal experimental conditions. The relative standard deviation of the blank signals was 3.0% and the detection limit of lead ion was 5.0${\times}$$10^-9$M.