Seismic Analysis of 3D-Truss by Response Spectrum (응답스펙트럼에 의한 트러스 구조물의 내진해석)

  • 안주옥;이승재
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.159-168
    • /
    • 1999
  • In seismic analysis, there are two main ways - uniform load method and dynamic analysis, dynamic analysis can be divided into response spectrum analysis and time history analysis. In case of which get the complexion of the vibration with 3-axis of coordinate direction in each mode of free vibration mode happened owing to complication of the shape, 3-dimensional dynamic analysis is recommended to perform as multi-mode spectral analysis in standard specification for highway bridge. The purpose of this study is to understand the dynamic behavior by performing multi-mode seismic analysis according to responses analysis and time history anal)'sis in using record of earthquake. In accordance with the criterion of seismic design as defined in standard specification for highway bridge by using modified records of the El Centre and Coyote Lake earthquake, response spectrum was constructed by using the tripartite logarithmic plot. The 3-span continuous space truss bridge was selected as model of numerical analysis. As the result performed time history analysis and analysis of response spectrum for the model of numerical analysis, the result of time history analysis was slightly larger than that of response spectrum analysis. This coincide with the tendency of the result came from the analysis when using a jagged response spectrum analysis, This coincide with the tendency of the result came from the analysis when using a jagged response spectrum for a single excitation. In the Process of performing these two analysis. response spectrum analysis is more effective than time history analysis in saving times in analyzing data.

  • PDF

A response spectrum method for seismic response analysis of structures under multi-support excitations

  • Li, Jian-Hua;Li, Jie
    • Structural Engineering and Mechanics
    • /
    • v.21 no.3
    • /
    • pp.255-273
    • /
    • 2005
  • Based on the random vibration theory, a response spectrum method is developed for seismic response analysis of linear, multi-degree-of-freedom structures under multi-support excitations is developed. Various response quantities, including the mean and variance of the peak response, the response mean frequency, are obtained from proposed combination rules in terms of the mean response spectrum. This method makes it possible to apply the response spectrum to the seismic reliability analysis of structures subjected to multi-support excitations. Considering that the tedious numerical integration is required to compute the spectral parameters and correlation coefficients in above combination rules, this paper further offers simplified procedures for their computation, which enhance dramatically the computational efficiency of the suggested method. The proposed procedure is demonstrated for tow numerical examples: (1) two-span continuous beam; (2) two-tower cabled-stayed bridge by using Monte Carlo simulation (MC). For this purpose, this paper also presents an approach to simulation of ground motions, which can take into account both mean and variation properties of response spectrum. Computed results based on the response spectrum method are in good agreement with Monte Carlo simulation results. And compared with the MSRS method, a well-developed multi-support response spectrum method, the proposed method has an incomparable computational efficiency.

Development of a Design Seismic Wave Time History Generation Technique Corresponding to the Recorded Seismic Wave-Based Design Response Spectrum (계측 지진파 기반 설계응답스펙트럼에 상응하는 설계 지진파 시간이력 생성 기법 개발)

  • Oh, Hyun Ju;Park, Hyung Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.687-695
    • /
    • 2021
  • With the recent occurrence of large-scale earthquakes in Korea, the importance of seismic design has greatly increased. Seismic design standards stipulate that dynamic time history analysis be performed for important or special structures. In the seismic analysis and design of such structures, determining a rational design input seismic wave is a very important factor in ensuring the reliability of the analysis and design. In the seismic design standards, rational design seismic waves must reflect the characteristics of the area (fault) and satisfy the design response spectrum for each seismic performance level. This requirement can be partially satisfied by modifying the actual seismic wave measured in the area (fault) according to the design response spectrum. In this study, a method of correcting and generating seismic wave time histories according to the design response spectrum based on actual measured seismic waves using the harmonic wavelet transform was proposed. To examine the applicability of the proposed technique, the technique was applied to earthquakes of magnitude 5.8 and 5.4, respectively, that occurred in Gyeongju (2016) and Pohang (2017), and the seismic wave time histories corresponding to the design response spectrum were modified and generated.

Efficient seismic analysis of multi-story buildings

  • Lee, Dong Guen;Kim, Hee Cheul
    • Structural Engineering and Mechanics
    • /
    • v.4 no.5
    • /
    • pp.497-511
    • /
    • 1996
  • The equivalent static force procedure and the response spectrum analysis method are widely used for seismic analyses of multi-story buildings. The equivalent static force procedure is one of the most simple but less accurate method in predicting possible seismic response of a structure. The response spectrum analysis method provides more accurate results while it takes much longer computational time. In the response spectrum method, dynamic response of a multi-story building is obtained by combining modal responses through a proper procedure such as SRSS or CQC method. Since all of the analysis results are expressed in absolute values, structural engineers have difficulties to combine them with the results obtained from the static analysis. Design automation is interrupted at this stage because of the difficulty in the decision of the most critical design load. Pseudo-dynamic analysis method proposed in this study provides more accurate seismic analysis results than those of the equivalent static force procedure since the dynamic characteristics of a structure is considered. And the proposed method has an advantage in combination of the analysis results due to gravity loads and seismic loads since the direction of the forces can be considered.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Seismic response and retrofitting proposals of the St. Titus Chruch, Heraklion, Crete, Greece

  • Tzanakis, Michael J.;Papagiannopoulos, George A.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • v.10 no.6
    • /
    • pp.1347-1367
    • /
    • 2016
  • The purpose of this work is to investigate the seismic behavior of St. Titus Church in Heraklion, Crete, Greece as well as the need of its seismic retrofitting. A numerical model of the Church is constructed using shell finite elements and it is then seismically examined using response spectrum and linear time-history analyses. Effects of soil-structure interaction have been also taken into account. The Church without retrofit is expected to exhibit extensive tensile failures and many compressive ones. Aiming to maintain the architectural character of the structure as well as to increase its seismic resistance, a retrofitting procedure involving injection of cement grout in conjunction with reinforced concrete jacketing to the internal side of the masonry walls is proposed. A numerical implementation of the proposed seismic retrofitting is performed and its effect is evaluated by response spectrum and linear time-history analyses. From the results of these analyses, it is shown that compressive failures are eliminated while only few tensile failures of local character take place.

Simulation of Artificial Earthquake Wave Compatible with Seismic Design Spectrum and Its Response Characteristics (내진 설계용 스펙트럼에 적합한 인공지진파의 작성과 응답 특성)

  • Jun, Dae-Han;Kang, Pyeong-Doo;Kim, Jae-Ung
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.141-148
    • /
    • 2006
  • This study describes a generation of artificial earthquake wane compatible with seismic design spectrum. In seismic response analysis of building structures, the input ground accelerations have considerable effect on dynamic characteristics of structures. Therefore, it is important to properly select input ground motions for seismic response analysis. In this paper, the artificial earthquake wave are generated according to previously recorded earthquake waves in past earthquake events. The artificial wave have identical phase angles to the recorded earthquake wane, and their overall response spectra are compatible with seismic design spectrum with 5% of critical viscous damping. Each simulated earthquake wave has a identical phase angles to the original recorded ground acceleration, and match to design response spectra in the range of period from 0.02 to 10.0 seconds. It is concluded that the artificial earthquake waves simulated in this paper ate applicable as input ground motions for a seismic response analysis of building structures.

  • PDF

Evaluation of Seismic Fragility Curve of Seismically Isolated Nuclear Power Plant Structures for Artificial Synthetic Earthquakes Corresponding to Maximum-Minimum Spectrum (최대-최소 스펙트럼에 대응하는 인공합성지진에 대한 면진된 원전구조물의 지진취약도 곡선 평가)

  • Kim, Hyeon-Jeong;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.89-99
    • /
    • 2019
  • In order to increase the seismic safety of nuclear power plant (NPP) structures, a technique to reduce the seismic load transmitted to the NPP structure by using a seismic isolation device such as a lead-rubber bearing has recently been actively researched. In seismic design of NPP structures, three directional (two horizontal and one vertical directions) artificial synthetic earthquakes (G0 group) corresponding to the standard design spectrum are generally used. In this study, seismic analysis was performed by using three directional artificial synthetic earthquakes (M0 group) corresponding to the maximum-minimum spectrum reflecting uncertainty of incident direction of earthquake load. The design basis earthquake (DBE) and the beyond design basis earthquakes (BDBEs are equal to 150%, 167%, and 200% DBE) of G0 and M0 earthquake groups were respectively generated for 30 sets and used for the seismic analysis. The purpose of this study is to compare seismic responses and seismic fragility curves of seismically isolated NPP structures subjected to DBE and BDBE. From the seismic fragility curves, the probability of failure of the seismic isolation system when the peak ground acceleration (PGA) is 0.5 g is about 5% for the M0 earthquake group and about 3% for the G0 earthquake group.

Investigation of seismic performance of super long-span cable-stayed bridges

  • Zhang, Xin-Jun;Zhao, Chen-Yang;Guo, Jian
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.493-503
    • /
    • 2018
  • With the further increase of span length, the cable-stayed bridge tends to be more slender, and becomes more susceptible to the seismic action. By taking a super long-span cable-stayed bridge with main span of 1400m as example, structural response of the bridge under the E1 horizontal and vertical seismic excitations is investigated numerically by the multimode seismic response spectrum and time-history analysis respectively, the seismic behavior and also the effect of structural nonlinearity on the seismic response of super long-span cable-stayed bridge are revealed. Furthermore, the effect of structural parameters including the girder depth and width, the tower structural style, the tower height-to-span ratio, the side-tomain span ratio, the auxiliary piers in side spans and the anchorage system of stay cables etc on the seismic performance of super long-span cable-stayed bridge is investigated numerically by the multimode seismic response spectrum analysis, and the favorable earthquake-resistant structural system of super long-span cable-stayed bridge is proposed.

Conditional mean spectrum for Bucharest

  • Vacareanu, Radu;Iancovici, Mihail;Pavel, Florin
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.141-157
    • /
    • 2014
  • The Conditional Mean Spectrum represents a powerful link between the seismic hazard information and the selection of strong ground motion records at a particular site. The scope of the paper is to apply for the city of Bucharest for the first time the method to obtain the Conditional Mean Spectrum (CMS) presented by Baker (2011) and to select, on the basis of the CMS, a suite of strong ground motions for performing elastic and inelastic dynamic analyses of buildings and structures with fundamental periods of vibration in the vicinity of 1.0 s. The major seismic hazard for Bucharest and for most of Southern and Eastern Romania is dominated by the Vrancea subcrustal seismic source. The ground motion prediction equation developed for subduction-type earthquakes and soil conditions by Youngs et al. (1997) is used for the computation of the Uniform Hazard Spectrum (UHS) and the CMS. The disaggregation of seismic hazard is then performed in order to determine the mean causal values of magnitude and source-to-site distance for a particular spectral ordinate (for a spectral period T = 1.0 s in this study). The spectral period of 1.0 s is considered to be representative for the new stock of residential and office reinforced concrete (RC) buildings in Bucharest. The differences between the Uniform Hazard Spectrum (UHS) and the Conditional Mean Spectrum (CMS) are discussed taking into account the scarcity of ground motions recorded in the region of Bucharest and the frequency content characteristics of the recorded data. Moreover, a record selection based on the criteria proposed by Baker and Cornell (2006) and Baker (2011) is performed using a dataset consisting of strong ground motions recorded during seven Vrancea seismic events.