• Title/Summary/Keyword: seismic earthquake response

Search Result 1,592, Processing Time 0.026 seconds

Evaluation of Ductility Factors for MDOF Systems in Special Steel Moment Resisting Frames (철골 연성 모멘트 골조에 대한 다자유도 시스템의 연성계수 평가)

  • Kang, Cheol-Kyu;Han, Young-Cheol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.13-22
    • /
    • 2004
  • Ductiluty factor has played an important role in seismic design as it is key component of response modification factor(R). In this stuty, ductility factors() are calculated by multiplying ductility factor for SDOF systems() and MDOF modification factors(). Ductility factors() for SDOF systems are computed from nonlinear dynamic analysis undergoing different level of displacement ductiluty demands and period when subjected to a large number of recorded earthquake ground motions. The MDOF modification factors() are proposed to account for the MDOF systems, based on previous studies. A total of 108 prototype steel frames are designed to investigate the ductility factors considering the number of stories(4, 8 and 16-stories), framing system(Perimeter Frames, PF and Distributed Frames, DF), failure mechanism(Strong-Column Weak-Beam, SCWB and Weak-Column Strong-Beam, WCSB), soil profiles(SA, SC and SE in UBC 1997) and seismic zone factors(Z=0.075, 0.2 and 0.4 in UBC 1997). It is shown that the number of stories, failure mechanisms (SCWB, WCSB), and soil profiles have great influence on the ductility factors, however, the structural system(Perimeter frames, Distributed frames), and seismic zones have no influence on the ductility factors.

Incorporation preference for rubber-steel bearing isolation in retrofitting existing multi storied building

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Hussain, Raja Rizwan;Hosen, Md. Akter;Huda, Md. Nazmul
    • Computers and Concrete
    • /
    • v.16 no.4
    • /
    • pp.503-529
    • /
    • 2015
  • Traditionally, multi-story buildings are designed to provide stiffer structural support to withstand lateral earthquake loading. Introducing flexible elements at the base of a structure and providing sufficient damping is an alternative way to mitigate seismic hazards. These features can be achieved with a device known as an isolator. This paper covers the design of base isolators for multi-story buildings in medium-risk seismicity regions and evaluates the structural responses of such isolators. The well-known tower building for police personnel built in Dhaka, Bangladesh by the Public Works Department (PWD) has been used as a case study to justify the viability of incorporating base isolators. The objective of this research was to establish a simplified model of the building that can be effectively used for dynamic analysis, to evaluate the structural status, and to suggest an alternative option to handle the lateral seismic load. A finite element model was incorporated to understand the structural responses. Rubber-steel bearing (RSB) isolators such as Lead rubber bearing (LRB) and high damping rubber bearing (HDRB) were used in the model to insert an isolator link element in the structural base. The nonlinearities of rubber-steel bearings were considered in detail. Linear static, linear dynamic, and nonlinear dynamic analyses were performed for both fixed-based (FB) and base isolated (BI) buildings considering the earthquake accelerograms, histories, and response spectra of the geological sites. Both the time-domain and frequency-domain approaches were used for dynamic solutions. The results indicated that for existing multi-story buildings, RSB diminishes the muscular amount of structural response compared to conventional non-isolated structures. The device also allows for higher horizontal displacement and greater structural flexibility. The suggested isolation technique is able to mitigate the structural hazard under even strong earthquake vulnerability.

Analysis of Response Spectrum of Ground Motions from Odaesan Earthquake (2007/01/20) (오대산지진(2007/01/20) 관측자료를 이용한 응답스펙트럼 분석)

  • Kim, Jun-Kyoung
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.871-877
    • /
    • 2007
  • The response spectrum was studied using the observed pound motion from the Odaesan Earthquake (2007/01/20), and then the results were compared to the seismic design response spectra (Reg Guide 1.60) applied to the domestic nuclear power plants. For the response spectrum analysis, 21 horizontal and 8 vertical observed Pound motions were used for normalization and statistical analysis. The results showed that the MPOSD (Mean Plus One Sigma Standard Deviation) response spectra above 10 Hz revealed higher values than the design response spectra and those below 10 Hz revealed much lower values fur both horizontal and vertical response spectra. These results suggest that the response spectra (Reg. Guide 1.60), used as seismic design code for nuclear facilities in Korea, especially above about 10 Hz, should be reexamined fur apllication to the nuclear power plants structures operated in the Korean Peninsula.

Effect of relative stiffness on seismic response of subway station buried in layered soft soil foundation

  • Min-Zhe Xu;Zhen-Dong Cui;Li Yuan
    • Geomechanics and Engineering
    • /
    • v.36 no.2
    • /
    • pp.167-181
    • /
    • 2024
  • The soil-structure relative stiffness is a key factor affecting the seismic response of underground structures. It is of great significance to study the soil-structure relative stiffness for the soil-structure interaction and the seismic disaster reduction of subway stations. In this paper, the dynamic shear modulus ratio and damping ratio of an inhomogeneous soft soil site under different buried depths which were obtained by a one-dimensional equivalent linearization site response analysis were used as the input parameters in a 2D finite element model. A visco-elasto-plastic constitutive model based on the Mohr-Coulomb shear failure criterion combined with stiffness degradation was used to describe the plastic behavior of soil. The damage plasticity model was used to simulate the plastic behavior of concrete. The horizontal and vertical relative stiffness ratios of soil and structure were defined to study the influence of relative stiffness on the seismic response of subway stations in inhomogeneous soft soil. It is found that the compression damage to the middle columns of a subway station with a higher relative stiffness ratio is more serious while the tensile damage is slighter under the same earthquake motion. The relative stiffness has a significant influence on ground surface deformation, ground acceleration, and station structure deformation. However, the effect of the relative stiffness on the deformation of the bottom slab of the subway station is small. The research results can provide a reference for seismic fortification of subway stations in the soft soil area.

Seismic Analysis of Liquid Storage Structures sing Eulerian Formulation (Eulerian 기법을 이용한 유체저장구조물의 지진해석)

  • 윤정방;김재민;김영석;전영선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.43-48
    • /
    • 1991
  • In this paper the liquid sloshing effects in rectangular liquid stroage structures under earthquake loadings are studied. The study focuses on the investigation of the effect of the flexibility of the stroage wall. The storage structure is modelled using beam elements. The motion of the liquid is expressed by the Laplace equation. The equation of motion is formulated including the coupling between the wall motion and the sloshing motion. Seismic analyses have been carried out utilizing the response spectra method.

  • PDF

Nonlinear Aseismic Analysis of Spent Fuel Storage Racks(I) (핵폐기물 저장설비의 비선형 내진해석(I))

  • Lee, Chong-Dong;Chang, Jae-Wan;Yoo, Bong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.191-198
    • /
    • 1993
  • This paper presents the analysis briefs to evaluate the structural adequacy of the KMRR spent fuel storage racks which stack modules in three layers. The seismic analysis models are idealized to consider the overall dynamic motions such as rocking, sliding and liftoff in the event of an postulated earthquake. The displacement time histories of the floor obtained from the floor response spectra in three orthogonal directions are simultaneously applied to the nonlinear seismic model of the structure with gap and friction elements.

  • PDF

Seismic response control of benchmark highway bridge using variable dampers

  • Madhekar, S.N.;Jangid, R.S.
    • Smart Structures and Systems
    • /
    • v.6 no.8
    • /
    • pp.953-974
    • /
    • 2010
  • The performance of variable dampers for seismic protection of the benchmark highway bridge (phase I) under six real earthquake ground motions is presented. A simplified lumped mass finite-element model of the 91/5 highway bridge in Southern California is used for the investigation. A variable damper, developed from magnetorheological (MR) damper is used as a semi-active control device and its effectiveness with friction force schemes is investigated. A velocity-dependent damping model of variable damper is used. The effects of friction damping of the variable damper on the seismic response of the bridge are examined by taking different values of friction force, step-coefficient and transitional velocity of the damper. The seismic responses with variable dampers are compared with the corresponding uncontrolled case, and controlled by alternate sample control strategies. The results of investigation clearly indicate that the base shear, base moment and mid-span displacement are substantially reduced. In particular, the reduction in the bearing displacement is quite significant. The friction and the two-step friction force schemes of variable damper are found to be quite effective in reducing the peak response quantities of the bridge to a level similar to or better than that of the sample passive, semi-active and active controllers.

A study on preventing the fall of skew and curved bridge decks by using rubber bearings

  • Ijima, Katsushi;Obiya, Hiroyuki;Aramaki, Gunji;Kawasaki, Noriaki
    • Structural Engineering and Mechanics
    • /
    • v.12 no.4
    • /
    • pp.347-362
    • /
    • 2001
  • The paper deals with preventing the collapse of by the means of supporting the bridges by rubber bearings and pedeck structures of skew and curved bridges during earthquakes, rmitting pounding between the decks and the abutments. Seismic response during pounding is characterized by various phenomena, such as the caging of bridge decks between abutments during an earthquake or decks popping out. These behaviors depend on only a small difference in seismic intensity. Regarding the global characteristics of a seismic response, smaller clearance between a deck and its abutments results in smaller impact damage of the abutments as well as lesser deformation of the rubber bearings. Similarly, smaller clearance between a deck and the side blocks results in smaller damage. The stiffnesses of the bearings and the stiffness ratio between them control the deck displacement. In short to medium length bridges, zero clearance between a deck and the abutments or the deck and the side blocks is the most effective way in preventing the deck from falling and limits the damage to the abutments or the side blocks.

Seismic response assessment of high-strength concrete frames strengthened with carbon fiber reinforced polymers

  • Rahmdel, Javad Mokari;Vahid-Vahdattalab, Farzin;Shafei, Erfan;Zirakian, Tadeh
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.735-744
    • /
    • 2021
  • In recent years, the use of new materials and technologies with the aim of developing high-performing and cost-effective structures has greatly increased. Application of high-strength concrete (HSC) has been found effective in reducing the dimensions of frame members; nonetheless, such reduction in dimensions of structural elements in the most cases may result in the lack of accountability in the tolerable drift capacity. On this basis, strengthening of frame members using fiber reinforced polymers (FRPs) may be deemed as an appropriate remedy to address this issue, which albeit requires comprehensive and systematic investigations. In this paper, the performance of properly-designed, two-dimensional frames made of high-strength concrete and strengthened with Carbon Fiber Reinforced Polymers (CFRPs) is investigated through detailed numerical simulation. To this end, nonlinear dynamic time history analyses have been performed using the Seismosoft software through application of five scaled earthquake ground motion records. Unstrengthened (bare) and strengthened frames have been analyzed under seismic loading for performance assessment and comparison purposes. The results and findings of this study show that use of CFRP can be quite effective in seismic response improvement of high-strength-concrete structures.

Self-centering passive base isolation system incorporating shape memory alloy wires for reduction in base drift

  • Sania Dawood;Muhammad Usman;Mati Ullah Shah;Muhammad Rizwan
    • Smart Structures and Systems
    • /
    • v.31 no.5
    • /
    • pp.531-543
    • /
    • 2023
  • Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.