• 제목/요약/키워드: seismic design/analysis method

검색결과 684건 처리시간 0.027초

현행 내진설계 규준에서 요구되는 수평강도의 평가 방법 (Method of Evaluation of the Strength Required in Current Seismic Design Code)

  • 한상환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.193-200
    • /
    • 1997
  • Current seismic design code is based of the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, base shear forces required to maintain target ductility ratio were first calculated from nonlinear dynamic analysis on the single degree of freedom system. And then, base shear foeces specified in seismic design code compare with above results. If the strength(base shear) required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of static nonlinear analysis(push-over analysis).analysis).

  • PDF

동적 해석법을 이용한 내진설계 결과의 비교 고찰 (Comparative Study on the Results of Seismic Design by Dynamic Analysis Method)

  • 이성우;노홍식;심규점
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.81-89
    • /
    • 1991
  • Recently increasing number of highrise buildings are aseismically designed by dynamic analysis method. To perform comparative study on the results of seismic design by dynamic analysis method, five-to thirty-story building models of ductile moment resisting frames and braced frames are considered. Base shears of these models using the spectrum of equivalent static method in the current Korean code and the ones of dynamic analysis method in the UBC-88 code are compared. Based on this study design spectra to be used in the dynamic analysis in Korea are proposed and the results are compared.

  • PDF

지진환경과 설계기준과 호환하는 대표 입력 지진파의 생성 (Generation of Seismic Environment and Design Code Compatible Representative Earthquake Motion)

  • 정창균;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.771-776
    • /
    • 2010
  • Since the importance of seismic design is greater, dynamic analysis is more widely using than past. The input motion is one of the most important factors of dynamic analysis. However, in Korea input motions are selected from U.S. and Japan those are captured from large magnitude earthquakes without considering seismic environment or generated in frequency domain. In this research, the methodology for generating input motions those are considered seismic environment and design code is proposed. The seismic environment compatibility is considered by performing deaggregation and the design code compatibility is considered by time-domain artificial time history accelration generation method. The results shows that seismic environment and design code compatible input motions are successfully generated.

  • PDF

An approach of seismic design for sheet pile retaining wall based on capacity spectrum method

  • Qu, Honglue;Li, Ruifeng;Hu, Huanguo;Jia, Hongyu;Zhang, Jianjing
    • Geomechanics and Engineering
    • /
    • 제11권2호
    • /
    • pp.309-323
    • /
    • 2016
  • As the forefront of structural design method, capacity spectrum method can be applied conveniently, and through this method, deformation demand of structure can be considered. However, there is no research for the seismic application in the structure of sheet pile retaining wall to report. Therefore, focusing on laterally loaded stabilizing sheet pile wall, which belongs to flexible cantilever retaining structure and meets the applying requirement of capacity spectrum method from seismic design of building structure, this paper studied an approach of seismic design of sheet pile wall based on capacity spectrum method. In the procedure, the interaction between soil and structure was simplified, and through Pushover analysis, seismic fortification standard was well associated with performance of retaining structure. In addition, by comparing the result of nonlinear time history analysis, it suggests that this approach is applicable.

등가정적해석법에 의한 수계 파이프 시스템의 내진설계 (The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.100-105
    • /
    • 2012
  • 본 연구에서는 수계소화설비 가압송수장치의 파이프라인에 대한 내진설계를 수행하였다. 내진해석에 필요한 내진설계용 스펙트럼에 대응하는 인공지진 진동파형을 작성하였고, 작성된 인공지진 진동에 대한 응답 스펙트럼 가속도를 결정하여 등가정적하중을 결정하였다. 내진설계를 위한 공학적 기반을 구축하였으며, 수계 및 가스계 파이프 시스템의 내진설계를 위한 등가정적해석법을 제시하였다. 또한 본 연구의 결과로부터 수계설비의 파이프라인뿐만 아니라 소방설비의 내진설계 및 성능평가에 응용할 수 있는 기틀을 마련하였다. 향후 진도규모 및 지반종류에 따른 추가적인 연구가 수행된다면 소방시스템의 신뢰성 향상과 안전성 제고, 성능위주설계가 이루어질 수 있을 것으로 본다.

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

3D-based equivalent model of SMART control rod drive mechanism using dynamic condensation method

  • Ahn, Kwanghyun;Lee, Kang-Heon;Lee, Jae-Seon;Chang, Seongmin
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1109-1114
    • /
    • 2022
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the feasibility and applicability of a 3D-based equivalent model using dynamic condensation method for seismic analysis of a SMART control rod drive mechanism. The equivalent model is utilized for complicated seismic analysis during the design of the SMART. While the 1D-based beam-mass equivalent model is widely used in the nuclear industry for its calculation efficiency, the 3D-based equivalent model is suggested for the seismic analysis of SMART to enhance the analysis accuracy of the 1D-based equivalent model while maintaining its analysis efficiency. To verify the suggested model, acceleration response spectra from seismic analysis based on the 3D-based equivalent model are compared to those from the 1D-based beam-mass equivalent model and experiments. The accuracy and efficiency of the dynamic condensation method are investigated by comparison to analysis results based on the conventional modeling methodology used for seismic analysis.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

기존 학교 건축물의 내진성능평가 및 보강방안 제안 (Proposed Seismic Performance Evaluation Enhancement for Existing School Building)

  • 황지훈;장정현;양경석;최재혁
    • 교육시설 논문지
    • /
    • 제19권4호
    • /
    • pp.29-38
    • /
    • 2012
  • Recently large scale earthquake s are occurred around the world following the damage of buildings. So the interest of preparing for earthquake seismic design and seismic performance has becoming high. School buildings are though used for educational purpose; they are also used as emergency shelter for local residents during earthquake disaster. However, the current seismic design ratio of our country (Korea) is 3.7% and if massive earthquake is occurred it follows a serious damage. In order to overcome this situation, seismic performance evaluation is carried out for existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear static analysis on existing school buildings for ATC-40 and FEMA-356 are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to verify the effect of retrofit enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effect of seismic retrofit time history analysis using nonlinear dynamic analysis is also performed and nonlinear behavior of earthquake load of seismic retrofit of structures was also investigated.

도시철도 지중 콘크리트 구조물의 내진해석법 적용에 관한 연구 (A Study of seismic analysis method of urban rail transit's underground concrete structure)

  • 이희영;이동호;김은겸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1159-1164
    • /
    • 2005
  • Seismic analysis methods in use on ground structure are equivalentstatic analysis, response-displacement method and dynamic analysis etc. Equivalentstatic analysis does not considerdynamic effect, and dynamic analysis process is very complex. then 'Urbanrail transit earthquake-resistance design standard (2005.06)' is persuading that analyze by response displacement method that consider enough dynamic effect of ground structure statically. But, It is very complex and difficult to apply response-displacement method in the field. So, modified equivalentstatic analysis or pseudo static analysis that is easy to apply in the field and have rationality of design is practically used. In this study, I try to prescribe the applicable scale of structure and static analysis that have calculative effectiveness about response-displacement method by comparing and analyzing the result of each analysis method according to the scale of urban rail transit' box type concrete structure and by performing seismic analysis that apply modified equivalentstatic analysis, pseudo static analysis and response-displacement method changing the kind of ground, depth of bedrock, size of structure.

  • PDF