• 제목/요약/키워드: seismic amplification

검색결과 279건 처리시간 0.027초

인공 매립 지반에서의 지진파 증폭 특성 (Seismic Motion Amplification Characteristics at Artificial Reclaimed Land)

  • 김용성;문용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1134-1139
    • /
    • 2005
  • Seismic motion amplification owing to the input motion level at bedrock is one of the important topics to understand various geomaterials behavior. The extremely valuable borehole records at Port Island were obtained during the 1995 Hyogoken Nanbu Earthquake and also before and after the main event. In this study, the seismic motion amplification at the soft reclaimed ground was discussed. Comparison of measured records with numerical simulation results were made with focus on seismic motion amplification characteristics at the soft reclaimed ground.

  • PDF

구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수 (Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes)

  • 임승현;최인길;전법규;곽신영
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

수직비정형과 비틀림비정형을 동시에 가지는 저층 RC 건물의 내진성능에 관한 연구 (Study on the Seismic Performance for Low-rised RC Building with Vertical and Torsional Irregularities)

  • 최인혁;백은림;이상호
    • 대한건축학회논문집:구조계
    • /
    • 제35권12호
    • /
    • pp.137-148
    • /
    • 2019
  • Korean piloti-type buildings are comprised of pilotis in the first story and shear walls in the upper stories. This vertical irregularity causes excessive lateral plastic deformation on the first story while the upper stories stay elastic. Meanwhile, asymmetric position of structural components such as core walls and columns of RC piloti-type buildings tends to produce torsional irregularities of the structures. Korean Building Code(KBC2016) requires the special seismic load and torsional amplification factor to apply to the piloti-type buildings lower than six-story or 20m if it has vertical and torsional irregularities when the building corresponds to seismic design category C or D. Many Korean low-rised RC buildings fall into the class. Therefore, the special earthquake load and torsional amplification factor are often applied to a building simultaneously. However, it has not been studied enough how much influence each parameter has on buildings with vertical and torsional irregularities at the same time. The purpose of this study is to evaluate the effect of factor special seismic load and torsional amplification on seismic performance of irregular buildings. In this study, a damaged 4th story piloti-type building by the Pohang earthquake was selected and the earthquake response analysis was carried out with various seismic design methods by the KBC 2016. The effect of the design parameters on seismic performance was analyzed by the dynamic analysis of models with special seismic load and torsional amplification factor based on the selected building. It was concluded that the application of the torsional amplification factor to the reference model to which special seismic design was applied, does not significantly affect the seismic performance.

Dynamic simulation models for seismic behavior of soil systems - Part II: Solution algorithm and numerical applications

  • Sahin, Abdurrahman
    • Geomechanics and Engineering
    • /
    • 제9권2호
    • /
    • pp.169-193
    • /
    • 2015
  • This paper is the second part of the study for determining the seismic behavior of soil systems. The aim of this part is to present solution approaches for determining seismic site amplification. For this purpose, two solution techniques are used. The first technique is equivalent linear analysis which is mostly used in literature. The other technique is real time parameter updating approach and this approach uses the possibilities of Simulink effectively. A graphical user interfaced (GUI) program called DTASSA standing for Discrete-Time Analysis of Seismic Site Amplification is developed. In DTASSA, automatic block diagram producing system is developed and seismic site amplification for multiple soil layers may easily be investigated in real time. Numerical applications have been carried out to check the reliability of developed algorithm. The results of DTASSA are compared with SUA, EERA and NERA programs for the particular example problems.

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

다양한 다층 지반모형에 대한 지진동 증폭 (Earthquake Amplification for Various Multi-Layer Ground Models)

  • 정수근;김호연;김대현
    • 지질공학
    • /
    • 제33권2호
    • /
    • pp.293-305
    • /
    • 2023
  • 지진이 발생할 때 대한 지진동 증폭 현상을 확인하기 위해 1g 진동대와 연성토조(Laminar Shear Box, LSB)를 이용하여 모형지반을 조성하였고, 3가지 모델에 대하여 지진동 증폭현상에 대하여 확인하였다. 3가지의 모형지반을 선정하였으며 모든 모형지반에서 조밀한 층과 느슨한 층으로 나누었고, 지반모형의 경우는 다층 수평지반, 다층 제방지반, 다층 분지지반모형으로 선정하였다. 각 지반모형을 제작하며 가속도계 매설을 진행하였으며, 인공지진파, Sinesweep파와 Sine 10 Hz의 지진파를 통하여 증폭현상을 확인하였다. 최대지반가속도(Peak ground acclelration, PGA)와 응답스펙트럼 가속도(Spectrum acceleration, SA)를 통해 지진동 증폭현상을 확인하였다. 수평 다층지반에서 조밀한 지반을 통과 후 느슨한 지반에서 가속도 증폭이 조밀한 지반에 비해 크게 발생하는 것을 확인할 수 있었으며, 다른 두 모형지반에서는 층의 경계면을 통과 후 점차 중심부에서 가속도 증폭이 더 크게 발생하는 것을 확인할 수 있었다.

매립 지반에서의 지진파 증폭 특성 (Seismic Motion Amplification Characteristics at Reclaimed Ground)

  • 김용성;김기영;전제성
    • 한국농공학회논문집
    • /
    • 제47권5호
    • /
    • pp.51-61
    • /
    • 2005
  • In this study, borehole records were analyzed to verify the amplification of seismic motion at the soft reclaimed ground before and after the main event of the 1995 Hyogoken Nambu Earthquake at Port Island, Japan. From the analysis, it was shown that the amplification of seismic motion occurred near the soft ground surface (within 30 m below) where confining stress is low. Moreover, it was found that recovery of dynamic soil stiffness at the liquefied ground began gradually 3 hours after the liquefaction and completed in 10 days, when the ground exhibited the same seismic motion characteristics as those before the liquefaction.

Seismic microzonation of Kolkata

  • Shiuly, Amit;Sahu, R.B.;Mandal, Saroj
    • Geomechanics and Engineering
    • /
    • 제9권2호
    • /
    • pp.125-144
    • /
    • 2015
  • This paper presents the probabilistic seismic microzonation of densely populated Kolkata city, situated on the world's largest delta island with very soft alluvial soil deposit. At first probabilistic seismic hazard analysis of Kolkata city was carried out at bedrock level and then ground motion amplification due to sedimentary deposit was computed using one dimensional (1D) wave propagation analysis SHAKE2000. Different maps like fundamental frequency, amplification at fundamental frequency, peak ground acceleration (PGA), peak ground velocity (PGV), peak ground displacement (PGD), maximum response spectral acceleration at different time period bands are developed for variety of end users, structural and geotechnical engineers, land use planners, emergency managers and awareness of general public. The probabilistically predicted PGA at bedrock level is 0.12 g for 50% exceedance in 50 years and maximum PGA at surface level it varies from 0.095 g to 0.18 g for same probability of exceedance. The scenario of simulated ground motion revealed that Kolkata city is very much prone to damage during earthquake.

Evaluating the effective spectral seismic amplification factor on a probabilistic basis

  • Makarios, Triantafyllos K.
    • Structural Engineering and Mechanics
    • /
    • 제42권1호
    • /
    • pp.121-129
    • /
    • 2012
  • All contemporary seismic Codes have adopted smooth design acceleration response spectra, which have derived by statistical analysis of many elastic response spectra of natural accelerograms. The above smooth design spectra are characterized by two main branches, an horizontal branch that is 2.5 times higher than the peak ground acceleration, and a declining parabolic branch. According to Eurocode EN/1998, the period range of the horizontal, flat branch is extended from 0.1 s, for rock soils, up to 0.8 s for softer ones. However, from many natural recorded accelerograms of important earthquakes, the real spectral amplification factor appears to be much higher than 2.5 and this means that the spectrum leads to an unsafe seismic design of the structures. This point is an issue open to question and it is the object of the present study. In the present paper, the spectral amplification factor of the smooth design acceleration spectra is re-calculated on the grounds of a known "reliability index" for a desired probability of exceedance. As a pilot scheme, the seismic area of Greece is chosen, as it is the most seismically hazardous area in Europe. The accelerograms of the 82 most important earthquakes, which have occurred in Greece during the last 38 years, are used. The soil categories are taken into account according to EN/1998. The results that have been concluded from these data are compared with the results obtained from other strong earthquakes reported in the World literature.

Occurrence mechanism of recent large earthquake ground motions at nuclear power plant sites in Japan under soil-structure interaction

  • Kamagata, Shuichi;Takeqaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권5호
    • /
    • pp.557-585
    • /
    • 2013
  • The recent huge earthquake ground motion records in Japan result in the reconsideration of seismic design forces for nuclear power stations from the view point of seismological research. In addition, the seismic design force should be defined also from the view point of structural engineering. In this paper it is shown that one of the occurrence mechanisms of such large acceleration in recent seismic records (recorded in or near massive structures and not free-field ground motions) is due to the interaction between a massive building and its surrounding soil which induces amplification of local mode in the surface soil. Furthermore on-site investigation after earthquakes in the nuclear power stations reveals some damages of soil around the building (cracks, settlement and sand boiling). The influence of plastic behavior of soil is investigated in the context of interaction between the structure and the surrounding soil. Moreover the amplification property of the surface soil is investigated from the seismic records of the Suruga-gulf earthquake in 2009 and the 2011 off the Pacific coast of Tohoku earthquake in 2011. Two methods are introduced for the analysis of the non-stationary process of ground motions. It is shown that the non-stationary Fourier spectra can detect the temporal change of frequency contents of ground motions and the displacement profile integrated from its acceleration profile is useful to evaluate the seismic behavior of the building and the surrounding soil.