• Title/Summary/Keyword: secondary wastewater

Search Result 165, Processing Time 0.028 seconds

Experimental investigation of the effect of baffles on the efficiency improvement of irrigation sedimentation tank structures

  • Nouri, Alireza Zamani;Heydari, Mohammad Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.63 no.4
    • /
    • pp.567-574
    • /
    • 2017
  • Sedimentation tanks are essential structures to filter the suspended sediments in the inlet flow which are constructed at the inlet of the basins forked from rivers and irrigation canals. The larger the constructed tank, the better the sedimentation process is conducted. However, the construction and dredging costs increase. In this regard, improving the performance and sedimentation efficiency seem necessary by alternative methods. One of these effective methods is using baffle plates. Most of the studies carried out in this field are on the use of these baffles in the primary and secondary sedimentation tanks. Hence, this study is carrier out with the objective of increasing the retention efficiency in the irrigation sedimentation tanks using baffles. To reach this goal, the experiments were carried out in a flume with length 8 meters, width 0.3 meters, and height 0.5 meters, considering a sedimentation tanks with a length of 3 meters, in three different inlet concentration, three flow rates and three Froude numbers. The baffles were mounted at the bottom of the tank and the effects of the angle, height and position in the tanks were investigated. The results showed that on average, employing the baffles increased the sedimentation efficiency 5 to 6% and the highest value was obtained for angle 60 with respect to the flow direction. According to the results of this study, the most favorable height and position of these baffles were obtained to be in 40% of the depth of the flow and 50% of the length of the sedimentation tank, respectively. Also, by increasing the number of baffles, the sedimentation efficiency decreased. Regarding the sedimentation regions in this case, more than 80% of the settled sediments were observed in the middle of the tank measured from the inlet.

Performance Evaluation of Tertiary Post-denitrification Processes for the Reuse of Secondary Effluent from Wastewater Treatment Plant (하수2차처리수의 재이용을 위한 후탈질공정의 평가)

  • Lee, Chanho;Yun, Zuwhan;Yi, Yun Seok;Lee, Han Saem;Ahn, Dong Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.642-649
    • /
    • 2007
  • The effectiveness of add-on tertiary treatment processes for the polishing of the effluent of a biological nutrient removal (BNR) system from a modified $A^2/O$ process has been examined under the field condition with pilot-scale plants. The add-on treatment processes of 1) combined biofilm anoxic reactor and sand filtration, and 2) two-stage denitrification filter had been operated with various operating conditions. The experimental results indicated that two-stage denitrification filter could produced a better polished tertiary effluent. Filtration rate of $150m^3/m^2{\cdot}d$ for the 2-stage denitrifying filter could decrease the nitrate removal probably due to shorter detention time that caused insufficient reaction for denitrification. Two stage denitrification filter operated with M/N ratio of 3.0 and filtration rate of $100m^3/m^2{\cdot}d$ produced the tertiary effluent with nitrate and SS concentraitons of 2.8 mg/L and 2.3 mg/L, respectively. When the operating temperature reduced $30^{\circ}C$ to $18^{\circ}C$, $NO_3{^-}-N$ removal efficiency decreased from 73% to 68%.

Impact of Factors on community-level health-related Quality of Life: Community Unit Analysis (지역사회 건강관련 삶의 질에 영향을 미치는 요인: 지역사회 단위 분석)

  • Jeong, Yong-Rae;Hahm, Myung-Il;Min, In-Soon;Kang, Eunjeong
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.276-285
    • /
    • 2015
  • The aim of this study was to identify the impact of community factors on the community-level Health-Related Quality of Life (HRQOL) in Korea. This was a cross-sectional study conducted in 2012 using secondary data(n=209) of the Korean Statistical Information Service. The framework was based on community factors provided by the International Council of Science (ICSU) and community factors were categorized based on six aspects. Multiple regression was applied to community factors depending on the community EQ-5D index. Smoking rate, "Good" self-rated health rate, water and wastewater coverage rate, and financial independency rate were significantly and positively associated with the EQ-5D score. Net migration rate(more move out than move in), obesity rate, unmet needed health care rate, and community type(rural than urban) were significantly and negatively associated with the EQ-5D score. This study identifies association for the impact of community factors on the community-level HRQOL and can provide useful evidence for development of community health promotion policies.

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.

Modeling Fate and Transport of Organic and Nitrogen Species in Soil Aquifer Treatment-(I) Model Development and Verification (토양/대수층 처리(soil aquifer treatment)에서 유기물과 질소화합물 제거와 이송 모델링-(I) 모델 개발 및 검증)

  • Kim Jung-Woo;Kim Jeong-Kon;Cha Woo-Suk;Choi Hee-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.9-15
    • /
    • 2005
  • Soil aquifer treatment is a water reuse technology that secondary or tertiary treated wastewater is infiltrated into the aquifer in which physical and biochemical reactions occur. Major consideration in SAT is the removal and transport of DOC and nitrogen species. In this study, reaction mechanism in SAT was examined considering nitrification, denitrification and organic oxidation. In addition, SAT modeling system was developed as the reaction mechanism was applied to groundwater flow and transport model. In verification of the reaction module by 1-dimensional unsaturated soil column test, the experimental data of all of the species, ammonium, nitrate, DOC and DO, were well matched with the simulation results. In sensitivity analysis, ammonium partition coefficient, dissolved oxygen inhibition constant and biomass decay rate affect ammonium, DOC and DO concentration of effluent, respectively.

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준)

  • Yang, Hong-Mo;Rhee, Chong-Ouk
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • A model of pond system is developed for treatment and recycling of excreta from twenty-five adult dairy cattle. It is composed of wastewater treatment ponds and small fish ponds. Those are three facultative ponds in series; primary-secondary-tertiary pond and these are designed to rear carps without feeding. A pit is constructed at the bottom of primary pond for efficient sludge sedimentation and effective methane fermentation. It is contrived to block into it the penetration of oxygen dissolved in the upper layer of pond water. The excreta from the cattle housed in stalls are diluted by water used for clearing them. The washed excreta flow into the pit. The average yearly $BOD_5$ concentration of influent is 398.7mg/l. That of the effluent from primary, secondary and tertiary pond of the system is 49.18, 27.9, and 19.8.mg/l respectively. Approximate 88, 93, and 95 % of BOD5 are removed in each pond. The mean yearly SS concentration of influent is 360.5 mg/l That of the effluent from each pond is 53.4, 45.7, and32.7mg/l respectively. Approximate 86, 88, and 91% of SS are removed in each pond. The $BOD_5$ concentration of secondary and tertiary pond can satisfy 30mg/l secondary treatment standard. The SS concentration of effluent from tertiary pond, however, is slightly greater than the standard, which results from activities of carps growing in the pond. The average yearly total nitrogen concentration of influent is 206.8mg/l and that of the effluent from each pond is 48.6, 30.8, and 21.0mg/l respectively. Approximate 74, 88, and 90% of total nitrogen are removed in each pond. The mean yearly total phosphorous concentration of influent is 20.7mg/l and that of the effluent from each pond is 5.3, 3.2, and 2.1mg/l respectively. Approximate 97, 98, and 99% of total phosphorous are removed in each pond. The high removal of nitrogen and phosphorous results from active growth of algae in the upper layer of pond water. Important pond design parameters for southern part of Korea -- areal loading of BOD5, liquid depth, hydraulic detention time, free board, and pond arrangement -- are taken up.

  • PDF

Survey of Physicochemical Methods and Economic Analysis of Domestic Wastewater Treatment Plant for Advanced Treatment of Phosphorus Removal (총인 수질기준강화를 위한 국내 하수종말처리장의 물리화학적처리 특성조사 및 경제성 분석)

  • Park, Hye-Young;Park, Sang-Min;Lee, Ki-Cheol;Kwon, Oh-Sang;Yu, Soon-Ju;Kim, Shin-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.212-221
    • /
    • 2011
  • Wastewater treatment plants (WWTPs) are required to meet the reinforced discharge standards which are differentiated as 0.2, 0.3 and 0.5 mg-TP/L for the district I, II and III, respectively. Although most of WWTPs are operating advanced biological phosphorus removal system, the supplementary phosphorus treatment facility using chemical addition should be required almost at all WWTPs. Therefore, water quality data from several exemplary full-scale plants operating phosphorus treatment process were analyzed to evaluate the reliability of removal performance. Additionally, a series of jar tests were conducted to find optimal coagulants dose for phosphorus removal by chemical precipitation and to describe characteristics of the reaction and sludge production. Chemical costs and the increasing sludge volume in physicochemical phosphorus removal process were estimated based on the results of jar tests. The minimum coagulant (aluminium sulfate and poly aluminium chloride) doses to keep TP concentration below 0.5 and 0.2 mg/L were around 25 and 30 mg/L (as $Al_2O_3$), respectively, in the mixed liquor of activated sludge. In the tertiary treatment facility, relatively lower coagulant doses of 1/12~1/3 the minimum doses for activated sludge were required to achieve the same TP concentrations of 0.2~0.5 mg/L. Increase in suspended solids concentration due to chemical precipitates in mixed liquor was estimated at 10~11%, compared to the concentration without chemical addition. When coagulant was added into mixed liquor, chemical (aluminium sulfate) cost was estimated to be 4~10 times higher than in secondary effluent coagulation/separation process. Sludge production to be wasted was also 4~10 times higher than secondary effluent coagulation/separation process.

Polycyclic Aromatic Hydrocarbons in Industrial Organic Sludge from Wastewater Treatment Facilities in Korea (폐수처리시설에서 발생된 유기성 슬러지에 함유된 다환방향족탄화수소의 농도 특성)

  • Nam, Seong-Nam;Lee, Mi-Young;Yeon, Jinmo;Jeon, Taewan;Shin, Sun Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.574-582
    • /
    • 2012
  • This study presents the concentrations of the polycyclic aromatic hydrocarbons (PAHs) listed as priority pollutants by United States Environmental Protection Agency (US EPA), in 98 sludges from 54 industrial wastewater treatment facilities of South Korea. The mean concentrations of ${\Sigma}_{16}PAHs$ were ranged from 32.5 ${\mu}g/kg-dw$ to 1189.3 ${\mu}g/kg-dw$ by industries, and the highest content was found in the petrochemical industry, followed by chemical, clothing manufacturing and dying, pulp and papermaking, secondary wastewater treatment, and food/beverage producing industries. Comparisons to the EU and Danish standards of ${\Sigma}_{16}PAHs$ in sewage sludge for land application showed only two samples (one from petrochemical, and the other from chemical industry) exceeded the limits. ANOVA test with PAH concentrations as variables revealed no statistically significant influences by industrial types and sampling time (i.e., seasonal variations). Pearson correlations between individual PAHs showed strong relationships (r>0.7) among 4-ring PAHs. Concentrations of acenaphthylene, anthracene, fluoranthene, benzo(a)anthracene, benzo(f)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene presented strong correlations to ${\Sigma}_{16}PAHs$. Principal component analysis discriminated entire samples into three groups by two principal components (PC1 and PC2) with 70% of data variations, in which industrial types were not of importance, but a dominance of certain PAHs. Samples in group-I, which is high PC1 and low PC2, were characterized by a dominance of 2-ring PAHs, and in group-II, PC1 and PC2 showed a linear relation, was dominant 4-ring PAHs. Group-III with low PC1 and high PC2 includes 17 samples showing a noticeably high contribution of 3-ring PAHs to ${\Sigma}_{16}PAHs$. This study provides concentrations of PAHs in industrial sludges collected from a wide variety of sources (six industrial types) and two seasons of sampling events, and the comparison of ${\Sigma}_{16}PAHs$ with other studies are also discussed.

Microbial Risk Assessment in Treated Wastewater Irrigation on Paddy Rice Plot (하수처리수를 관개한 후 벼재배 시험구에 대한 미생물 위해성 평가)

  • Jung, Kwang-Wook;An, Youn-Joo;Jang, Jae-Ho;Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.2 s.112
    • /
    • pp.225-236
    • /
    • 2005
  • The protection of public health In wastewater reclamation and reuse is one of the most important issues. Monitoring data of Escherichia coli were collected from paddy rice plots in 2003 and 2004 experiments. Five treatments were used and each one was triplicated to evaluate the changes of E. coli: surface water, biofilter effluent (secondary level), UV-disinfected water and pond treatment. Microbial risk was quantified to assess human health risk by exposure to E. coli in paddy rice plots, which were irrigated with reclaimed wastewater. Beta-Poisson model was used to estimate the microbial risk of pathogen ingestion that may occur to farmer and neighbor children. Monte-Carlo analysis (10,000 trials) was used to estimate the risk characterization of uncertainty. In the following analysis, two scenarios were related to the reduction of risk against direct ingestion and exposure times. Scenarios A and B were assumed that the risk was 1,000 and 10,000 times lower than direct ingestion.'Golfers were assumed to be 0.001 L of reclaimed water by contact with balls and their cloths. Opportunity of contact in paddy rice field with pathogens was more frequent than handing golf balls, because of agricultural activity was practiced in ponded water in paddy rice culture. As a result of microbial risk assessment using total data of experimental period, risk value of E. coli in 2003 and 2004 experiment ranged from $10^{-5}$ to $10^{-8}$ and $10^{-4}$ to $10^{-8}$, respectively. The risk values in biofilter effluent irrigation was the highest, which is $10^{-4}$ in 2003 and $10^{-5}$ in 2004 experiments with scenario A. Ranges of $10^{-6}$ to $10^{-8}$ were considered at reasonable levels of risk for communicable disease transmission from environmental exposure and the risk value above $10^{-4}$ was considered to be attributable to the risk of infection. Irrigation with UV-disinfected water in the paddy field during the agricultural Period showed significantly lower microbial risk than others, and their levels of risk value were within the range of actual paddy rice field with surface water.