• 제목/요약/키워드: secondary beam

검색결과 302건 처리시간 0.023초

Nd:YAG 레이저를 이용한 자동차 배터리용 SS41 다층박판 이종두께 T형상 용접 특성 (T-joint Welding Characteristics of Multi-thin Plate Dissimilar Thickness of SS41 of Automobile Battery by using Nd:YAG Laser)

  • 양윤석;황찬연;유영태
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1078-1088
    • /
    • 2012
  • In this paper, we present research experimental results about the different thickness T-joint welding of the high power continuous wave(CW) Nd:YAG laser for the secondary battery of a vehicle. Although the conventional method used for the secondary battery is a argon TIG welding, we utilize a laser welding to improve Tungsten Inert Gas(TIG) welding's weakness. The laser, which has a couple of advantage such as aspect ratio, low Heat Affected Zone(HAZ), good welding quality and fast productivity utilized in this work is a CW Nd:YAG laser. In order to observe laser welding sections, we used a optical microscope. Through the analysis of the metallographic, hardness, aspect ratio, and heat input, we obtained the desired data in condition of 1800 W laser beam power and 1.8 m/min and 2.0 m/min laser beam travel speeds. In order to compare electric resistances of the argon TIG welding and laser welding, we made an actual battery and the electric resistance of the laser welding is reduced by 40~45% comparing with the argon TIG welding.

산소 플라즈마 처리후의 이차전자방출계수(γ)를 이용한 MgO 보호막의 일함수(φW) 변화 (Work Function Changes on MgO Protective Layer after O2plasma Treatment from Ion-induced Secondary Electron Emission Coefficient)

  • 정재천;유세기;조재원
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.259-263
    • /
    • 2005
  • The changes in secondary electron emission coefficient(${\gamma}$) and work function($\Phi$$_{\omega}$) have been studied on the surface of MgO protective layer aster plasma(Ar. $O_2$) treatment using ${\gamma}$-focused ion beam (${\gamma}$-FIB) system. The values of ${\gamma}$ varied as follows: $O_2$-treated MgO > Ar-treated MgO > Non-treated MgO, and the work functions varied in the reverse order. The result indicates that both the physical etching and the chemical reaction of $O_2$-plasma removed the contaminating materials from the surface of MgO.

Behavior of SFRC interior beam-column joints under cyclic loading

  • Khalaf, Noor Ayaad;Qissab, Musab Aied
    • Structural Monitoring and Maintenance
    • /
    • 제7권3호
    • /
    • pp.167-193
    • /
    • 2020
  • In this paper, the behavior of interior steel fiber reinforced concrete beam - column joints (BCJs) under cyclic loading is investigated. An experimental program including tests on twelve reinforced concrete (BCJs) specimens under cyclic loading was carried out. The test specimens are divided into two groups having different geometry: group (G1) (symmetrical BCJs specimens) and group (G2) (nonsymmetrical BCJs specimens). The parameters considered in this study are the steel fibers (SFs) content by volume of concrete (Vf), the spacing of shear reinforcement at the joint region, and the area of longitudinal flexural reinforcement. Test results show that the addition of 0.5% SFs with stirrups spacing S=Smax has effectively enhanced the overall performance of BCJs with respect to energy dissipation, ductility ratio, spreading and width of cracks. The failure of specimens is governed mainly by the formation of a plastic hinge at the face column and outside the beam-column junction. Secondary shear cracks were also observed in the beam-column junctions.

냉음극형 대면적 전자빔의 공간적 분포 특성 (Characteristics of spatial distribution of cold cathode type large aperture electron beam)

  • 우성훈;;조주현;김광훈;이홍식;임근희;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2170-2172
    • /
    • 1999
  • A low energy large aperture(LELA) pulsed electron beam generator of a cold cathode type has been developed for environmental applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. We have fabricated the LELA electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large aperture electron beam in air. The electron beam current density has been investigated as a function of glow discharge current, accelerating voltage and radial distribution in front of the exit window foil. The plasma density and electron temperature have been measured in order to confirm the relation with the electron beam current density. We are going to upgrade the LELA electron beam generator in the electron energy, electron beam current and stability of operation for various applications.

  • PDF

Low Frequency Vibration Energy Harvester Using Stopper-Engaged Dynamic Magnifier for Increased Power and Wide Bandwidth

  • Halim, Miah Abdul;Kim, Dae Heum;Park, Jae Yeong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.707-714
    • /
    • 2016
  • We present a piezoelectric energy harvester with stopper-engaged dynamic magnifier which is capable of significantly increasing the operating bandwidth and the energy (power) harvested from a broad range of low frequency vibrations (<30 Hz). It uses a mass-loaded polymer beam (primary spring-mass system) that works as a dynamic magnifier for another mass-loaded piezoelectric beam (secondary spring-mass system) clamped on primary mass, constituting a two-degree-of-freedom (2-DOF) system. Use of polymer (polycarbonate) as the primary beam allows the harvester not only to respond to low frequency vibrations but also generates high impulsive force while the primary mass engages the base stopper. Upon excitation, the dynamic magnifier causes mechanical impact on the base stopper and transfers a secondary shock (in the form of impulsive force) to the energy harvesting element resulting in an increased strain in it and triggers nonlinear frequency up-conversion mechanism. Therefore, it generates almost four times larger average power and exhibits over 250% wider half-power bandwidth than those of its conventional 2-DOF counterpart (without stopper). Experimental results indicate that the proposed device is highly applicable to vibration energy harvesting in automobiles.

MgO의 전자선 증착율에 따른 PDP 방전 특성 분석 (Analysis of PDP Discharging Properties Depending on Electron Beam Evaporation Rate of MgO Layer)

  • 김용재;권상직
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.716-719
    • /
    • 2007
  • The effects of the evaporation rate of MgO films using an electron beam on the MgO properties and the discharge characteristics of a plasma display panel (PDP) were investigated and analyzed. MgO films were deposited with the various MgO evaporation rates. The MgO properties such as the crystal orientation, the surface roughness, and the film structure were inspected using XRD (X-ray diffraction), AFM (atomic force microscopy). From the experiments and Paschen law, the maximum value of the secondary electron emission coefficient $({\gamma})$ was obtained at the evaporation rate of $5{\AA}/sec$. The XRD results and cathode-luminescence (CL) spectra show the ${\gamma}$ values are correlated with F/F+ centers of the molecular structure of MgO films. The minimum firing voltage and the maximum luminous efficiency were obtained at an evaporation rate of $5{\AA}/sec$. In the MgO film deposited at $5{\AA}/sec$, the (200) orientation and F+ center were most intensive.

2거더 강-콘크리트 합성형 철도교의 거동에 대한 2차부재의 영향 평가 (The Effect of Secondary Members on the Behavior of Steel-Concrete Composite Two-Girder Railway Bridges)

  • 배두병;조준희
    • 한국철도학회논문집
    • /
    • 제8권1호
    • /
    • pp.41-50
    • /
    • 2005
  • Steel -Concrete Composite two girder railway bridges applying high performance steel with extra thick plate have economic and aesthetic advantages due to the simplification of manufacturing and construction process. However, steel bridges are seldom adopted in domestic railway bridge, since steel bridges are not efficient as R.C bridges considering dynamic characteristics and noise, etc. While highway bridges do not have lower horizontal bracing and larger interval of diaphragm cross beam, railway bridges install lower horizontal bracings to control the torsion due to heavy eccentrical line load. Accurate finite element analysis were performed with the parameters of existence of bracing and bracing shape, with the cross beam interval and stiffness, etc. To find out the effects of secondary members such as horizontal bracings and diaphragms, static md dynamic analysis have been performed by using finite element method. In this study, few member plate-girder bridges are analyzed with variable span lengths to examine the dynamic behavior and limits of damping. And though lateral bracings are members against torsion, but lateral bracing's absence is no big problem. Time history analysis using mode superposition method makes proof of this result.

SIMS와 GDMS를 이용한 구리와 탄탈 박막내의 주요불순물 분석 (Analysis of dominant impurities in Cu and Ta films using SIMS and GDMS)

  • 임재원
    • 한국진공학회지
    • /
    • 제13권2호
    • /
    • pp.79-85
    • /
    • 2004
  • 본 논문은 구리와 탄탈 박막내에 불순물로써 함유되기 쉬운 수소와 탄소, 그리고 산소 원소에 대해 이차이온 질량분석기(secondary ion mass spectrometry)와 글로우방전 질량분석기(glow discharge mass spectrometry)를 이용하여 분석하였고, 이들의 분석결과에 대해서 고찰하였다. 구리와 탄탈 박막은 실리콘 기판 위에 비질량 분리형 이온빔 증착장비를 이용하여 기판 바이어스를 걸지 않은 경우와 -50 V(구리 박막) 또는 -125 V(탄탈 박막)의 기판바이어스를 걸은 상태에서 증착하였다. 세슘 이온빔을 이용하여 분석한 SIMS 결과에서, 기판 바이어스를 걸지 않은 경우, 상당히 많은 피크들이 강하게 관찰되었는데 이는 위의 주요불순물들의 결합에 의한 상태로 검출된 것으로 이들 주요불순물들의 조합에 의해 가능한 질량번호를 산출하여 SIMS 결과의 모든 피크들을 해석할 수 있었다. 또한, 박막 내의 주요불순물들의 정량적인 GDMS 분석에 의해 SIMS 결과와의 일치성을 확인할 수 있었다.

Chemical Imaging Analysis of the Micropatterns of Proteins and Cells Using Cluster Ion Beam-based Time-of-Flight Secondary Ion Mass Spectrometry and Principal Component Analysis

  • Shon, Hyun Kyong;Son, Jin Gyeong;Lee, Kyung-Bok;Kim, Jinmo;Kim, Myung Soo;Choi, Insung S.;Lee, Tae Geol
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.815-819
    • /
    • 2013
  • Micropatterns of streptavidin and human epidermal carcinoma A431 cells were successfully imaged, as received and without any labeling, using cluster $Au_3{^+}$ ion beam-based time-of-flight secondary ion mass spectrometry (TOF-SIMS) together with a principal component analysis (PCA). Three different analysis ion beams ($Ga^+$, $Au^+$ and $Au_3{^+}$) were compared to obtain label-free TOF-SIMS chemical images of micropatterns of streptavidin, which were subsequently used for generating cell patterns. The image of the total positive ions obtained by the $Au_3{^+}$ primary ion beam corresponded to the actual image of micropatterns of streptavidin, whereas the total positive-ion images by $Ga^+$ or $Au^+$ primary ion beams did not. A PCA of the TOF-SIMS spectra was initially performed to identify characteristic secondary ions of streptavidin. Chemical images of each characteristic ion were reconstructed from the raw data and used in the second PCA run, which resulted in a contrasted - and corrected - image of the micropatterns of streptavidin by the $Ga^+$ and $Au^+$ ion beams. The findings herein suggest that using cluster-ion analysis beams and multivariate data analysis for TOF-SIMS chemical imaging would be an effectual method for producing label-free chemical images of micropatterns of biomolecules, including proteins and cells.

상악에서 발생한 석회화를 동반한 치성각화낭 (Odontogenic keratocyst with dystrophic calcifications in the maxilla)

  • 김태영;허경회
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.99-101
    • /
    • 2010
  • Odontogenic keratocyst (OKC) with secondary inflammation involving the maxillary sinus was presented. Radiological diagnosis of this case was made based on the various findings from the cone-beam computed tomography, computed tomography and magnetic resonance images. There were calcified materials and impacted tooth within the lumen of the lesion, which is not uncommon in OKC. Histopathologic findings confirmed this lesion as OKC with secondary inflammation.