• Title/Summary/Keyword: secY

Search Result 5,778, Processing Time 0.033 seconds

The Role of Heart Rate Recovery: Possibility of Heart Disease and Exercise Program Application (회복 시 심박수의 역할: 심장질환과 운동프로그램 적용 가능성)

  • Lee, Hae Sung;Kim, Jong-Hee
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.34 no.3
    • /
    • pp.166-172
    • /
    • 2019
  • Heart rate is a relatively simple and non-invasive method that is used as an important physiological indicator in many studies and has a close relationship with heart structure and function, cardiovascular disease and sudden cardiac death. In general, appropriately low heart rate during resting means effective heart function and cardiovascular fitness; heart rate at recovery is an important indicator of health and disease condition. We found a beagle dog (Dog_1) with a high heart rate in the previous preliminary experiment. Therefore, purpose of this study was to compare the heart rate response of the Dog_1 with the control group during 12 weeks of interval exercise, to evaluate the structural and functional abnormalities of the heart and to verify the applicability of exercise program. Heart rate was checked during 12 weeks of interval exercise, and after the exercise was over, imaging examination and hematological and serum biochemistry were performed. As a result, Dog_1 (165.6 ± 1.5) showed significantly higher heart rate in low intensity session of interval exercise than control group (133.3 ± 0.5, p < 0.01). In addition, Dog_1 (181.2 ± 1.4) showed significantly higher heart rate than control group (155.1 ± 0.9) in high intensity session (p < 0.01). The heart rate (30 sec, 60 sec) during recovery state was higher in Dog_1 (30 sec: 156.8 ± 4.0, 60 sec: 166.8 ± 5.8) than in the control group (30 sec: 111.2 ± 2.5, 60 sec: 104.0 ± 5.1, p < 0.01). The results of the imaging examination of Dog_1 with high heart rate confirmed that the heart had no functional and structural abnormalities. All beagles with the interval exercise program did not show maladjustment, and in the hematological and serum biochemistry results, all the parameter were within the reference range. If the interval exercise program of this study is used in the future, it is expected to be used as an important basic data to achieve the purpose of health, welfare, and physical fitness improvement of dogs.

A study on the maneuverabilities of the marine research vessel CHARMBADA (해양조사선 참바다호의 조종성능에 관한 연구)

  • An, Young-Su;Bae, Gwang-Min;Jang, Choong-Sik;Jung, Yun-Soo;Kang, Il-Kwon;Kim, Bo-Yeon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.1
    • /
    • pp.56-69
    • /
    • 2010
  • This study was intended to determine the maneuverability of the vessel CHARMBADA. When the rudder angle was at $10^{\circ}$, $20^{\circ}$ and $30^{\circ}$, the maximum advance by slow, half and full ahead were varied in the range of 523.6-131.3m, 528.8-177.2m and 530.6-219.7m, respectively. The maximum transfer was 799.9-181.3m, 792.1-232.8m and 807.7-316.9m, respectively. The turning circle ability was better during starboard turning. When the rudder angle was $10^{\circ}$, $20^{\circ}$ and $30^{\circ}$, variation in the maximum advances was 392.0m, 245.0m and 153.0m. The maximum transfer was 528.0m, 339.0m and 218.0m, respectively based on the regression equations. As the rudder angle became bigger, the maximum advance or maximum transfer became smaller by the exponential function. The advance inertia took 127sec, 145sec, 181sec each until the vessel speed was 7.0konts, 12.0konts, 17.0konts. The static inertia took 245sec, 269sec, 300sec each until the vessel speed was under 2.0konts and the advance distance was 114.4m, 181.2m, 197.0m each. Accordingly, the static inertia was inclined to increase to scale according to the increase in vessel speed. For the CHARMBADA, the smaller the rudder angle was, the much bigger the turning circle became due to adhesion to the skeg, thereby lowering the vessel's turning ability.

Effects of Circuit Weight Training on Isokinetic Muscle Strength and Body Composition in elderly (서킷 웨이트트레이닝이 노인들의 등속성 근력과 신체구성에 미치는 영향)

  • Chang Ghung-Hoon;Jeong Dong-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.168-181
    • /
    • 2003
  • The purpose of this study was to investigate the effects of circuit weight training(CWT) on isokinetic muscle strength and body composition in elderly. The subjects who engaged in this experiment exercised at 40$\%$ of 1-RM, 12 repetitions, followed by 15 sec as the subject moved to the each break training program which was consist of the circuit of 10 stations performed on 3 set a day, circuits 3 days a week during 10 weeks. The assessment of isokinetic factor was in concentric flexors and extensors of right and left knee joint. Tests were performed on the Cybex 770 Isokinetic Dynamometer and body composition were estimated the three parts of chest, abdomen and anterior thigh by using skinfold caliper, calculated the average and followed by Seri and Brozek way. Statistical analysis were performed using analysis of variance paired t-test, accepting level for all significant was above $\alpha$=.05 and $\alpha$=.01. Following is as a result of 10 weeks circuit weight training. 1. At the $60_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly (p < .01). 2. At the $180_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly (p < .01). 3. At the $60_{\circ}$ /sec, the right and left knee isokenetic concentric flexors and extensors average power increased significantly(p < 0.5, p < .01) and at the $180_{\circ}$ /sec, the right extensors didn't show any statistical significant. 4. At the $60_{\circ}$ /sec, the right and left knee Isokinetic concentric flexors and extensors total work increased significantly(p < .05, p < .01) but at the $180_{\circ}$ /su right concentric flexors didn't show any statistical significant. 5. The body composition changed significantly(p < .01). These results suggest that 10 weeks circuit weight training increases the peak torque, average power, total work significantly and decreases the $\%$body fat significantly.

  • PDF

Influence of Hip Abduction Velocity and Position on the Onset Times of Gluteus Medius and Tensor Fascia Latae Relative to Quadratus Lumborum in Healthy Subject: A Pilot Study

  • Kim, Jung-Bin;Yun, Chang-Kyo;Hwang-Bo, Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.105-110
    • /
    • 2016
  • PURPOSE: The aim of this study was to investigate the influence of hip abduction velocity and position change on the relative onset times of the gluteus medius, the tensor fascia latae, and the quadratus lumborum in healthy subjects. METHODS: For this study, 15 healthy young adults were recruited. The subjects were asked to move their hip joints up to 35 degrees of abduction at a speed of $70^{\circ}/sec$ and $17.5^{\circ}/sec$ in the supine and side-lying positions. Electromyography data was collected for the gluteus medius, tensor fascia latae, and quadratus lumborum to determine the onset times. RESULTS: There were significant differences between the fast speed ($70^{\circ}/sec$) and the slow speed ($17.5^{\circ}/sec$) in hip abduction in a supine position and in a side-lying position, relatively. The onset time of the gluteus medius was faster than that of the tensor fascia latae and the quadratus lumborum in the side-lying position at the speed of $70^{\circ}/sec$ and $17.5^{\circ}/sec$. CONCLUSION: The findings of this study indicated that hip abduction in a side-lying position is an effective method to recruit the gluteus medius earlier than the tensor fascia latae and the quadratus lumborum. Thus, the exercise position is considered necessory in the purpose of rehabilitation for gluteus medius muscle strengthening program.

A Study on the Optimal Make of X-ray Ionizer using the Monte Carlo N-Particle Extended Code(II) (Monte Carlo N-Particle Extended Code를 이용한 연 X선 정전기제거장치의 최적제작에 관한 연구(II))

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.29-33
    • /
    • 2017
  • In order to solve this sort of electrostatic failure in Display and Semiconductor process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. There exist variable factors such as type of tungsten thickness deposited on target, Anode voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. Here, MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was compared according to target material thickness using MCNPX and actual X-ray tube source under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W). At the result, In Tube voltage 5 keV and distance 100 mm, optimal target thickness is $0.05{\mu}m$ and fastest decay time appears + decay time 0.28 sec. - deacy time 0.30 sec. In Tube voltage 10keV and distance 100 mm, optimal target Thickness is $0.16{\mu}m$ and fastest decay time appears + decay time 0.13 sec. - deacy time 0.12 sec. In the tube voltage 15 keV and distance 100 mm, optimal target Thickness is $0.28{\mu}m$ and fastest decay time appears + decay time 0.04 sec. - deacy time 0.05 sec.

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

Estimation of Deposition Rates of Dustfall and Metallic Elements in Kunsan (군산지역의 강하분진 및 금속원소의 침착속도 추정)

  • 김성천
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.431-443
    • /
    • 2000
  • The purpose of this experimental study is to investigate seasonal deposition flux variations and deposition velocities of the total dusfall and various inorganic elements in it. Total 41 dustfall and TSP samples were collected from November, 1997 through December, 1998 in Kunsan. Each sample was analyzed by and AAS to determine he levels of 5 inorganic elements: Zn, Cd, Cr, Fe and Pb. Deposition fluxes, soluble/total fractions and deposition velocities for each element were extensively investigated. Estimated dry deposition fluxes of dustfall and elements in Kunsan were in the range of 14.6~48.8(mean 25.6) ton/$\textrm{km}^2$/yr for dustfall, 14.5~72.6(mean 44.1)kg/$\textrm{km}^2$/yr for Zn, 0.9~0.5(mean 3.0) kg/$\textrm{km}^2$/yr for Cd, 2.1~239.2(mean 63.9) kg/$\textrm{km}^2$/yr for Cr, 331.6~1,082.7(mean 873.9) kg/$\textrm{km}^2$/yr for Fe, 5.2~178.4(mean 49.2) kg/$\textrm{km}^2$/yr for Pb, respectively. And the concentra-tion of TSP and elements in Kunsan were 71$\mu\textrm{g}/m^3$ for TSP, $29.9ng/m^3$ for Zn, $0.6ng/m^3$ for Cd, $0.1 ng/m^3$ for Cr, $1,061.0 ng/m^3$ for Fe, $4.0 ng/m^3$ for Pb, respectively. And the estimated deposition velocity of dustfall and elements in Kunsan were 1.13$\times$ 10(sup)-2 cm/sec for dustfall, 4.67$\times$ 10(sup)-2 cm/sec for Zn, 16.92 cm/sec for Cd, 15.69 cm/sec for Cr, 1.72$\times$ 10(sup)-2 cm/sec for Fe, 0.36 cm/sec for Pb, respectively.

  • PDF

Electrofusion and preparation of transgenic plant by direct insert of marker gene (Marker gene의 직접삽입에 의한 transgenic plant의 제조 및 전기융합)

  • Hong, Kyung-Ae;Riu, Ki-Jung;So, In-Sup;Kim, Yang-Lok;U, Zang-Kual
    • Applied Biological Chemistry
    • /
    • v.36 no.6
    • /
    • pp.562-566
    • /
    • 1993
  • The conditions required for plant transformation through the electroporation system and for the electrofusion of the prtoplasts were investigated for geranium (Pelargonium zonale hybrids). The optimum condition for electroporation was 1.77 kV/cm for $40\;{\mu}sec$ under which 70% of the protoplasts were viable and 58% of the viable protoplasts were stained with methylene blue. The pBin19 DNA plasmid used as a carrier vector was isolated from E.coli $DH5{\alpha}$ strain, purified, identified by the electrophoresis on agarose gel and electroporated into the protoplasts. The KM8 liquid medium gave better cell division than any other media. One MHz of AC frequency with 40 V/cm of amplitude for 15 sec followed by 0.5 kV/cm of DC amplitude for $60\;{\mu}sec$ was most efficient for the electrofusion of protoplasts.

  • PDF

A Study on The Non-Point Source Pollutant Load Routing Method (비점원 오염부하량 산정에 관한 연구)

  • Kim, Young-Seob;Lee, Gwan-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.1
    • /
    • pp.11-18
    • /
    • 2008
  • After execute quantitative analysis that choose station and compose floodgate quality of water net and use floodgate data and quality of water data analysis target Sign of the cock as 1 dimension access for Non-point pollution source pollution and estimate of Gaeuncheon's at Kyongsangbukdo report to the Throne in this research, presented parameter conclusion notation model (AGNPS) in real condition of our agricultural area through comparison with spot value and result is as following in reply. With result observation and analysis result of the AGNPS model the comparison which it will pay from the hazard which it analyzes 2005, the rainfall thought which is used in the analysis to select 8 heavy rain thoughts 2005 July - is data until of September. Actual amount of rainfall 6.0~195.0 mm one time the antecedent precipitation showed API5 case 0.0~507.0mm and were observed peak flows (Qpeak) each from the P-1 $0.026m^3/sec{\sim}9.265m^3/sec$, from the P-2 $0.010m^3/sec-2.747m^3/sec$ and from the P-3c $0.064m^3/sec-13.482m^3/sec$ to show. Also amendment AMC condition it will be cool and it uses and the AGNPS model conference the result which it occurs, analysis and regression analysis of actual flow for as 0.992 very the possibility of getting the result which is good there was a decisive coefficient which is cool. But the gun is (T-P) with the total nitrogen (T-N) decisive coefficient each as 0.794 and 0.849 the presumption which is reliability generally will pay and with the fact that it will be the possibility of getting it is judged.

  • PDF

Sensitivity Analysis and Optimization of Design Variables Related to an Algorithm for Loss of Balance Detection (균형상살 검출 알고리즘에서 검출과 관련된 설계변수의 민감도 해석 몇 최적화)

  • Ko, B.K.;Kim, K.H.;Son, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • This study suggested an optimized algorithm for detecting the loss of balance(LOB) in the seated position. And the sensitivity analysis was performed in order to identify the role of each design variable in the algorithm. The LOB algorithm consisted of data processing of measured signals, an internal model of the central nervous system and a control error anomaly(CEA) detector. This study optimized design variables of a CEA detector to obtain improved values of the success rate(SR) of detecting the LOB and the margin time(MT) provided for preventing the falling. Nine healthy adult volunteers were involved in the experiments. All the subjects were asked to balance their body in a predescribed seated posture with the rear legs of a four-legged wooden chair. The ground reaction force from the right leg was measured from the force plate while the accelerations of the chair and the head were measured from a couple of piezoelectric accelerometers. The measured data were processed to predict the LOB using a detection algorithm. Variables S2, h2 and hd are related to the detector: S2 represents a data selecting window, h2 a time shift and hd an operating period of the LOB detection algorithm. S2 was varied from 0.1 to 10 sec with an increment of 0.1 sec, and both h2 and hd were varied from 0.01 to 1.0 sec with an increment of 0.01 sec. It was found that the SR and MT were increased by up to 9.7% and 0.497 sec comparing with the previously published case when the values of S2, h2 and hd were set to 4.5, 0.3 and 0.2 sec, respectively. Also the results of sensitivity analysis showed that S2 and h2 had considerable influence on the SR while these variables were not so sensitive to the MT.