• Title/Summary/Keyword: screw dislocation

Search Result 37, Processing Time 0.024 seconds

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

Results after Operative Treatment for Maisonneuve Fracture (Maisonneuve 골절에서 수술적 치료의 결과)

  • Lee, Jun-Young;Ha, Sang-Ho;Sohn, Hong-Moon;Lee, Kwang-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.72-78
    • /
    • 2007
  • Purpose: This study is to analysis the outcome of patient with surgically treated Maisonneuve fracture and find out the factors that might influence the outcome. Material and methods: 20 patients who had surgical treatment due to Maisonneuve fracture between February, 2001 to March, 2005 were studied. The patients were followed for at least 1 year and average follow up period was 25 months. The average age was 41 years, 16 were male and 4 were female. Mechanism of injury according to Rouge-Hansen classification was supination-external rotation. In all cases, percutaneous screw fixation was applied proximal to tibiofibular syndesmosis. The screws were removed after 8 weeks under local anesthesis. Clinical, functional and radiographic results were evaluated. Results: 17 cases (85%) showed satisfying clinical and radiographic results. The mean functional score according to Ankle Scoring System was 91 (83 to 95). Complication occurred in 1 case with underlying systemic disease and 2 cases with initial ankle joint dislocation. Conclusion: Surgical treatment of Maisonneuve fracture showed relatively satisfying result. However, initial injury state and accompanying disease seem to have great effect on the result.

  • PDF

Alloying Effects of BCC-Fe Based Low-Alloy Steel on Mechanical and Thermal Expansion Properties for a Plant Engineering: Ab Initio Calculation (플랜트 엔지니어링을 위한 BCC-Fe 기반 저합금강의 기계적 및 열팽창 특성 합금 효과: Ab Initio 계산)

  • Myungjae Kim;Jongwook Kwak;Jiwoong Kim;Kyung-Nam Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.10
    • /
    • pp.422-429
    • /
    • 2023
  • High-strength low-alloy steel is one of the widely used materials in onshore and offshore plant engineering. We investigated the alloying effect of solute atoms in α-Fe based alloy using ab initio calculations. Empirical equations were used to establish the effect of alloying on the Vicker's hardness, screw energy coefficient, and edge dislocation energy coefficient of the steel. Screw and edge energy coefficients were improved by the addition of V and Cr solute atoms. In addition, the addition of trace quantities of V, Cr, and Mn enhanced abrasion resistance. Solute atoms and contents with excellent mechanical properties were selected and their thermal conductivity and thermal expansion behavior were investigated. The addition of Cr atom is expected to form alloys with low thermal conductivity and thermal expansion coefficient. This study provides a better understanding of the state-of-the-art research in low-alloy steel and can be used to guide researchers to explore and develop α-Fe based alloys with improved properties, that can be fabricated in smart and cost-effective manners.

Comprehensive Structural Characterization of Commercial Blue Light Emitting Diode by Using High-Angle Annular Dark Filed Scanning Transmission Electron Microscopy and Transmission Electron Microscopy (고각 환형 암시야 주사투과전자현미경기법과 투과전자현미경기법을 이용한 상용 청색 발광다이오드의 종합적인 구조분석)

  • Kim, Dong-Yeob;Hong, Soon-Ku;Chung, Tae-Hoon;Lee, Sang Hern;Baek, Jong Hyeob
    • Korean Journal of Materials Research
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • This study suggested comprehensive structural characterization methods for the commercial blue light emitting diodes(LEDs). By using the Z-contrast intensity profile of Cs-corrected high-angle annular dark field scanning transmission electron microscope(HAADF-STEM) images from a commercial lateral GaN-based blue light emitting diode, we obtained important structural information on the epilayer structure of the LED, which would have been difficult to obtain by conventional analysis. This method was simple but very powerful to obtain structural and chemical information on epi-structures in a nanometer-scale resolution. One of the examples was that we could determine whether the barrier in the multi-quantum well(MQW) was GaN or InGaN. Plan-view TEM observations were performed from the commercial blue LED to characterize the threading dislocations(TDs) and the related V-pit defects. Each TD observed in the region with the total LED epilayer structure including the MQW showed V-pit defects for almost of TDs independent of the TD types: edge-, screw-, mixed TDs. The total TD density from the region with the total LED epilayer structure including the MQW was about $3.6{\times}10^8cm^{-2}$ with a relative ratio of Edge- : Screw- :Mixed-TD portion as 80%: 7%: 13%. However, in the mesa-etched region without the MQW total TD density was about $2.5{\times}10^8cm^{-2}$ with a relative ratio of Edge- : Screw- :Mixed-TD portion of 86%: 5%: 9 %. The higher TD density in the total LED epilayer structure implied new generation of TDs mostly from the MQW region.

Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis (요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰)

  • Kwon, Ji-Won;Kim, Jin-Gyu;Ha, Joong-Won;Moon, Seong-Hwan;Lee, Hwan-Mo;Park, Yung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • Purpose: Pedicle screw insertion has been traditionally used as a surgical treatment for degenerative lumbar spine disease. As an alternative, the cortical-bone trajectory screw allows less invasive posterior lumbar fixation and excellent mechanical stability, as reported in several biomechanical studies. This study evaluated the clinical and radiological results of a case of early failure of cortical-bone screw fixation in posterior fixation and union after posterior decompression. Materials and Methods: This study examined 311 patients who underwent surgical treatment from 2013 to 2018 using cortical orbital screws as an alternative to traditional pedicle screw fixation for degenerative spinal stenosis and anterior spine dislocation of the lumbar spine. Early fixation failure after surgery was defined as fixation failure, such as loosening, pull-out, and breakage of the screw on computed tomography (CT) and radiographs at a follow-up of six months. Results: Early fixation failure occurred in 46 out of 311 cases (14.8%), screw loosening in 46 cases (14.8%), pull-out in 12 cases (3.9%), and breakage in four cases (1.3%). An analysis of the site where the fixation failure occurred revealed the following, L1 in seven cases (15.2%), L2 in three cases (6.5%), L3 in four cases (8.7%), L4 in four cases (8.7%), L5 in four cases (8.7%), and S1 in 24 cases (52.2%). Among the distal cortical bone screws, fixation failures such as loosening, pull-out, and breakage occurred mainly in the S1 screws. Conclusion: Cortical-bone trajectory screw fixation may be an alternative with comparable clinical outcomes or fewer complications compared to conventional pedicle screw fixation. On the other hand, in case with osteoporosis and no anterior support structure particularly at L5-S1 fusion sites were observed to have result of premature fixation failures such as relaxation, pull-out, and breakage.

Open Reduction of Acromioclavicular Joint for the Acromioclavicular Joint Dislocations (견봉 쇄골 관절 탈구에 대한 견봉 쇄골 관절의 관혈적 정복술)

  • Song, Hyun-Seok;Choi, Nam-Yong;Han, Suk-Ku;Nah, Ki-Ho;Nam, Won-Sik;Yang, Hyuk-Jae;Park, Sung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.189-195
    • /
    • 2006
  • Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.

Biepicondylar Fracture of the Humerus in an Adult Female: A Case Report

  • Seong, Minkyu;Choi, Jungyun;Yum, Jaekwang
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.249-251
    • /
    • 2016
  • iepicondylar fracture of the humerus is very rare in adults. To date, there have been limited evidence of this injury in the English literature. We report a case of a 65-year-old female with a biepicondylar fracture of the left distal humerus without dislocation. Open reduction and internal fixation with K-wires, cannulated screw, and suture anchor were performed. We obtained stability of the elbow and a satisfactory functional outcome. Because this type of injury is associated with varus and valgus instability, operative reduction and fixation are essential in order to gain stability and early recovery of normal function.

Surface Structure and X-ray Topography of $NdAl_3(BO_3)_4$ Single Crystals Grown from High Temperature Solution of $BaO-B_2O_3-Nd_2O_3-Al_2O_3$ System ($BaO-B_2O_3-Nd_2O_3-Al_2O_3$계 고온 용액으로부터 성장된 $NdAl_3(BO_3)_4$ 단결정의 표면구조와 X-선 Topography)

  • 정선태;강진기;김정환;정수진
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 1994
  • By surface structure and X-ray topographic observation, growth mechanism of NAB single crystal grown by TSSG technique using a BaB4O7 flux was studied. Surface structure of grown crystals were investigated by optical microscope. Growth history and crystal defects included within grown crystal were investigated using X-ray topography. The {001} faces were grown by 2-D nucleation growth. As decreasing cooling rate, growth mechanism of {111} and {11} was changed from 2-D nucleation growth to the growth by screw dislocation. Only surface striations developed parallel to a-axis were observed on {010} faces. Growth sector of NAB crystals were divided into {001}, {111}, {010}, {021}, {11}. The inclusion which was usually trapped between {001} faces was investigated.

  • PDF

The Substructure Near Indents With Temperature During Microindentation on Basal (0001) Plane in Sapphire Single Crystals (사파이어 단결정의 basal (0001) 결정면에 미세압흔시 온도에 따른 압흔 주위 미세구조에 관한 연구)

  • Yun, Seok-Yeong
    • Korean Journal of Materials Research
    • /
    • v.10 no.11
    • /
    • pp.784-788
    • /
    • 2000
  • The Vickers microhardness was measured on the basal (0001) plane of sapphire single crystals in the temperature range from 25$^{\circ}C$to 1000$^{\circ}C$. The substructure surrounding the indents was investigated using selective chemical polishing and etching, optical microscopy, and trasmission electron microscopy (TEM). At room temperature, cracks were predominant, and at intermediate temperatures (400$^{\circ}C$and 600$^{\circ}C$), extensive rhombohedral twinning was observed. On the other hand, at higher temperatures, prism plane slip bands on prism plane {1120}(원문참조) were dominant in the microstructure. TEM observations revealed that the dislocation substructure at the vicinity of the indents consisted of fairly straight dislocations lying in basal and/or prism planes and aligned along the <1100> and <1120> directions. The details of the glide dissociation of perfect <110> screw dislocations into three collinear 1/3<1100> partials on the prism plane and the Peierls potential for sapphire single crystals were discussed.

  • PDF

Properties of AlN epilayer grown on 6H-SiC substrate by mixed-source HVPE method (6H-SiC 기판 위에 혼합소스 HVPE 방법으로 성장된 AlN 에피층 특성)

  • Park, Jung Hyun;Kim, Kyoung Hwa;Jeon, Injun;Ahn, Hyung Soo;Yang, Min;Yi, Sam Nyung;Cho, Chae Ryong;Kim, Suck-Whan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.3
    • /
    • pp.96-102
    • /
    • 2020
  • In this paper, AlN epilayers on 6H-SiC (0001) substrate are grown by mixed source hydride vapor phase epitaxy (MS-HVPE). AlN epilayer of 0.5 ㎛ thickness was obtained with a growth rate of 5 nm per hour. The surface of AlN epilayer grown on 6H-SiC (0001) substrate was investigated by field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray spectroscopy (EDS). Dislocation density was considered through HR-XRD and related calculations. A fine crystalline AlN epilayer with screw dislocation density of 1.4 × 109 cm-2 and edge dislocation density of 3.8 × 109 cm-2 was confirmed. The AlN epilayer on 6H-SiC (0001) substrate grown by using the mixed source HVPE method could be applied to power devices.