• 제목/요약/키워드: screen tests

검색결과 184건 처리시간 0.022초

식육중 잔류 향균물질의 검출을 위한 Bacillus megaterium 디스크 검사킷트 개발 (Development of Baccillus megaterium Disk Assay Kit for the Determination of Antibacterial Residues in Animal Tissues)

  • 손성완;조병훈;진남섭;이혜숙;윤순학;김재학;이재진;이영순
    • 한국식품위생안전성학회지
    • /
    • 제11권4호
    • /
    • pp.315-321
    • /
    • 1996
  • Various antimicrobial drug screen tests have been used in order to ensure food safety. However, the conventional screen tests, the Swab Test on Premises(STOP, USA), the Calf Antibiotic and Sulfa Test(CAST, USA) and the European Economic Community 4-plate Test(FPT, EU) are not sufficiently rapid or sensitive enough to detect low levels of sulfa drugs in meat. We developed a new screen test kit for the determination of the antimicrobial residues in meat called the Bacillus megaterium Disk Assay(BmDA). A comparison of BmDA with the older screen tests showed BmDA was as good as the older ones with several advantages. The new test kit is faster-it can be read in 4∼6 hours instead of 16∼18 hours. Moreover, BmDA can discriminate sulfa drugs from other antimicrobial drugs because p-aminobenzoic acid countacts the inhibiting action of sulfa drugs. Minimum detectable levels of sulfa drugs were significantly improved at the lever of 0.025*0.1 pp, compared with the level of 1.0 ppm in FPT. A comparison of BmDA with the older screen tests in HPLC confirmed meat samples exceeded the Korean tolerance value of 0.1 ppm showed BmDA was the most sensitive in the microbiological screen tests. As the microbiological screen tests have already known, a person familiar with simple laboratory techniques should have no difficulty in using it to detect antimicrobial residues in meat. This would be a simple, economic method of antimicrobial residues detection which might be succesfully used by many laboratories.

  • PDF

임베디드 웹 브라우저 기반의 3-Screen 영상서비스 개발 (Development of 3-Screen Video Service based on Imbedded Web Browser)

  • 송한춘;박명환
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권1호
    • /
    • pp.159-163
    • /
    • 2011
  • 본 논문에서는 하나의 애플리케이션을 개발/제작하여 모바일 스마트폰, 인터넷TV, 인터넷PC에서 동일하게 서비스를 제공할 수 있는 3-Screen 영상서비스 시스템을 개발하였다. 개발시스템은 동일한 임베디드 웹 브라우저를 각 3-Screen 영상서비스 단말에 탑재하여 영상서비스를 제공하게 된다. 개발시스템의 성능을 평가하기 위하여 농업생활 정보 애플리케이션을 본 논문에서 개발한 임베디드 웹 브라우저를 각 모바일 스마트폰, IPTV에 탑재하여 LG유플러스 통신망을 통하여 성능시험을 실시하였다. 성능시험결과 3-Screen서비스가 각 단말에서 원활하게 제공됨을 확인하였다. 논문의 구현결과는 향후 3-Screen 기반의 다양한 애플리케이션 개발에 활용이 가능할 것이다.

한국판 기능적 동작 검사의 신뢰도와 타당도 (Reliability and Validity of the Korean Version of the Functional Movement Screen)

  • 안승헌;이제훈
    • The Journal of Korean Physical Therapy
    • /
    • 제22권5호
    • /
    • pp.83-93
    • /
    • 2010
  • Purpose: The purpose of this study was to determine the reliability and validity of the Functional Movement Screen (FMS) for assessing Korean athletes. Methods: A total of 48 patients (37 males and 11 females) participated in this study. Data were acquired after translation of the FMS from English to Korean and cross-cultural adaptation of the this questionnaire. To determine inter-rater reliability, the relationship between the FMS scores obtained by two raters was evaluated using the Kappa coefficient, which was in total agreement with the Intra-Correlation Coefficient (ICC3,1). Concurrent validity was examined by correlating the FMS scores with the Oswestry disability index (ODI) scores and Visual analogue scale (VAS) scores. Results: The raters demonstrated excellent agreement on 7 (above 90%) of the 17 test (72.9 to 97.9%) components. Substantial agreement was seen in 11 of the 17 tests. Two components of the In-line lunge and rotatory stability tests demonstrated moderate agreement. It showed good inter-rater reliability: the Kappa coefficients ranged from 0.42 to 0.97. ICC3,1=0.42~0.99 and 0.93 (total FMS score). Cronbach's alpha for FMS was 0.80. It was not correlated with ODI or VAS. Conclusion: The Korean version of the FMS is a reliable instrument for measuring movement patterns of Korean athletes and for making decisions related to interventions for performance enhancement.

The Study of Corrosion Behavior of Active Screen Plasma Nitrided Stainless Steels

  • Chiu, L.H.;Chang, C.A.;Yeh, S.H.;Chen, F.S.;Chang, Heng
    • Corrosion Science and Technology
    • /
    • 제6권5호
    • /
    • pp.251-256
    • /
    • 2007
  • Plasma nitriding is a surface treatment process which is increasingly used to improve wear, fatigue and corrosion resistance of industrial parts. Active screen plasma nitriding (ASPN) has both the advantages of the classic cold wall and the hot wall conventional dc plasma nitriding (DCPN) method and the parts to be nitrided are no longer directly exposed to the plasma. In this study, AS plasma nitriding has been used to nitride the UNS S31803 duplex stainless steel, AISI 304 and AISI 316 austenitic stainless steel, and AISI 420 martensitic stainless steel. Treated specimenswere characterized by means of microstructural analysis, microhardness measurements and electrochemical tests in NaCl aerated solutions. Hardness of the nitride cases of AISI 420 stainless steel by Knoop test can get up to 1300 HK0.1. From polarization tests, the corrosion current densities of AISI 420 and UNS S31803specimens ASPN at $420^{\circ}C$ were generally lower than those of their untreated substrates. The corrosion resistance of UNS S31803 duplex stainless steel can be enhanced by plasma nitriding at $420^{\circ}C$ Cowing to the formation of the S-phase.

Minimum Hellinger Distance Bsed Goodness-of-fit Tests in Normal Models: Empirical Approach

  • Dong Bin Jeong
    • Communications for Statistical Applications and Methods
    • /
    • 제6권3호
    • /
    • pp.967-976
    • /
    • 1999
  • In this paper we study the Hellinger distance based goodness-of-fit tests that are analogs of likelihood ratio tests. The minimum Hellinger distance estimator (MHDE) in normal models provides an excellent robust alternative to the usual maximum likelihood estimator. Our simulation results show that the Hellinger deviance test (Simpson 1989) based goodness-of-fit test is robust when data contain outliers. The proposed hellinger deviance test(Simpson 1989) is a more direcct method for obtaining robust inferences than an automated outlier screen method used before the likelihood ratio test data analysis.

  • PDF

혈액은행 자동화 장비 도입의 유용성 평가 (Evaluation for the Usefulness of Automated Blood Typing Analyzer)

  • 김하나;김희범;박현상;이현임;홍명국;신경숙;서인범
    • 한국콘텐츠학회논문지
    • /
    • 제19권6호
    • /
    • pp.565-574
    • /
    • 2019
  • 본 연구는 혈액은행 자동화 장비 QWALYS-2 up (Diagast, Loos Cedex, France)의 유용성을 평가하기 위하여 수행되었다. 2013년 10월 1일부터 10월 31말까지 1개월간 강원대학교병원 진단검사의학과에 의뢰된 ABO 및 RhD 혈액형 검사 1,636건, 항체선별검사 1,374건을 대상으로 하였고, ABO 및 RhD 혈액형 검사의 평가는 200건을 대상으로 하였다. 혈액은행 자동화장비의 경제성을 평가하기 위해서는 2018년 12월을 기준으로 장비 도입 전인 2013년 1월부터 장비 도입 후 5개년의 ABO 및 RhD 혈액형 검사와 항체선별검사의 단가를 비교하였다. 본 연구의 주요 결과는 ABO 및 Rh 혈액형 검사 결과, 슬라이드나 시험관을 이용한 수기법의 결과가 100% (200/200) 일치하였고 동종항체 선별검사 결과, 불일치 3검체는 수기법으로 재검을 한 결과, 음성을 보여 QWALYS-2 up에서 위양성의 결과를 나타냈으나, 반응의 정도를 비교한 결과 QWALYS-2 up에서 상대적으로 높게 나타났다. 결론적으로 혈액형자동화 장비 도입 전후의 효과를 평가한 결과, 기존의 수기법과 비교하였을 때 높은 일치율을 보였으며, 정확도 면에서도 신뢰할 만한 것으로 판단되었다. 도입 전후의 시약의 비용은 증가하였지만 인건비의 절감을 감안하면 경제적으로도 유용하다고 평가할 수 있다.

정상 성인의 신체적 특성과 기능적 움직임 검사에 대한 융합적 상관관계 분석 (Convergence Correlation Analysis of Physical Characteristics and Functional Movement Screen in Healthy Adults)

  • 김현승;조성현
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.87-93
    • /
    • 2020
  • 본 연구는 신체적 특성과 기능적 움직임 검사(FMS)의 융합적 상관관계에 대해 알아보고자 한다. 연구대상자는 정상 성인으로 193명을 대상으로 단일측정하였다. 자료분석은 SPSS 26.0 Ver 프로그램으로 T-검증을 실시하였고, 각 변수들 간 피어슨 상관계수로 분석을 하였다. 분석결과, 검사 방법 중 능동 뻗은 다리 올림 검사와 몸통 안정성 푸쉬업 검사 영역에서 성별 간에 유의한 차이가 나타났다(P<.05). 어깨 가동성 검사와 능동 뻗은 다리 올림 검사 영역을 제외한 나머지 FMS의 검사에서 체지방률과 부적 상관관계가 있었다. 능동 뻗은 다리 올림에서 여성이 기능적 움직임의 질이 높았으며, 몸통 안정성 푸쉬업에서는 남성이 기능적 움직임의 질이 높았다. 그러므로 남성은 하지의 유연성을 보강해야하며, 여성은 상체 근력과 몸통의 안정성 운동을 적용해야 한다고 판단된다.

음악 스트리밍 앱 UX디자인의 사용성에 대한 연구 -멜론, 유튜브 뮤직, 지니, FLO앱을 중심으로 (Convergence Study on Usability of Music Streaming App UX Design)

  • 천승재;박진호
    • 한국융합학회논문지
    • /
    • 제12권2호
    • /
    • pp.135-146
    • /
    • 2021
  • 본 연구에서는 음악 스트리밍 서비스의 이용자 수가 점차 늘어가는 추세 속에서 사용자들에게 개선된 사용성을 가진 앱을 제공하고자 Screen Test기법과 실시 전후로 인터뷰를 진행하는 방식으로 사용성 테스트를 실시하고, Performance Measurement방식과 Contextual Inquiry방식을 사용하여 사용성 테스트 진행하였다. 사용성 테스트는 10대부터 50대 사용자 각 1명씩 진행하였으며 서비스 사용자가 많은 멜론, 유튜브 뮤직, 지니, FLO앱에서 진행하였다. 사용성 테스트 결과 아이콘이 기능을 충분히 나타내지 못하고 상호 작용 가능한 버튼으로 인식되지 못하여 사용자가 지나치는 점, 기능이 활성화 되었을 때 시각적 효과 부족으로 사용자가 인지하지 못하는 문제, 기능 배치가 연속적이지 않아 끊기는 사용성을 가지는 문제점을 도출하였다. 이에 대해 각 앱에 대해서 아이콘을 직관적으로 변경하고, 기능 활성화 시 화면의 시각적 효과를 추가하며, 기능이 연속성을 가지도록 위치 조정을 하는 등의 사용자 화면 개선안을 시각적 자료와 함께 제시했다.

다중 병렬 분기관을 이용한 압축공기 방파제의 소파효과에 관한 실험적 연구 (Experimental Study on Wave Attenuating Effect of a Pneumatic Breakwater by Using a Multiple Parallel Manifold)

  • 김종욱;신현수
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.257-262
    • /
    • 2004
  • A series of preliminary model tests are performed to find out the wave attenuating effect of the pneumatic breakwater of environment friendly type, which is a bubble screen generated by releasing compressed air from a submerged multiple parallel manifold Rising bubbles induce vertical current, which produces horizontal currents flowing away from the bubble-screen area in both directions. Near bottom, the corresponding currents flow toward the bubble screen, thus completing the circulation pattern. The surface current moving against the direction of wave propagation causes some attenuation of the waves. It becomes more effective as the relative depth (d/ L) increases (short-period waves in deep water). With the same air-discharge, the multiple parallel manifold can be more effective for the attenuation of longer waves through optimum arrangement of manifold number. installation depth, manifold gap, etc. The pneumatic breakwater will give a wide utilization as a device for protecting harbor facilities and as a simple, mobile breakwater.

  • PDF

촉각 기반 윈도우 인터페이스 (Manipulation of the Windows Interface Based on Haptic Feedback)

  • 이준영;경기욱;박준석
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 1부
    • /
    • pp.366-371
    • /
    • 2008
  • 본 논문에서는 터치스크린이 장착된 윈도우 시스템에서 촉각 피드백을 사용해 윈도우 인터페이스와 상호작용하는 방법 및 체계를 제안한다. 사용자가 터치 스크린을 통해 윈도우 인터페이스와 상호작용할 때 발생하는 주요 이벤트는 윈도우 인터페이스 메시지 필터(Windows Interface Message Filter: WIMF)에 의해 감지되고, 촉각 정보 제공기(Haptic Information Provider: HIP)를 통해 적절한 촉각 정보로 변환되어 본 연구에서 제안한 스타일러스형 햅틱 인터페이스를 통해 사용자에게 촉각 자극을 전달한다. 본 연구에서는 윈도우 환경의 주요한 조작 방법인 버튼 클릭, 메뉴 선택 및 팝업, 창/아이콘 선택 및 끌어놓기(drag & drop), 스크롤에 대하여 촉각 피드백을 구현하였다. 피험자 실험결과 촉각 피드백은 상호작용하는 인터페이스 객체가 선택되었는지에 대한 사용자의 직관을 증대시켰으며, 인터페이스 객체의 위치 및 크기 조절 시 인터페이스의 정교한 조작을 도와 사용성을 증대시켰다.

  • PDF