• Title/Summary/Keyword: scoring matrix

Search Result 35, Processing Time 0.023 seconds

A Study on Technology for Involute Bevel Gear Design (인벌류트 베벨기어 설계 기술에 관한 연구)

  • Cho, Seong-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2003
  • Design method for involute bevel gears is developed. The developed gear design system can design the optimized gear that minimize the number of pinion teeth with face tooth. Method of optimization is MS(matrix search) which is developed from this study. Design variables are pressure angle 20., transmitted power, gear volume, gear ratio, allowable contact stress and allowable bending stress. etc. Gears design method developed this study can be applied to the plane, helicopter, printer, machine tools.

Case Study for Fingerprint ID Doorlock Design Development (지문인식도어락 디자인 개발 사례연구)

  • 서수웅
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.3
    • /
    • pp.115-123
    • /
    • 2004
  • This study suggests the output of the fingerprint doorlock design development through the structured methodology of concept selection in the process of design development, after characterizing the doorlock product itself. All of the early phases of product development are very important on eventual product success. Concept selection is the process of evaluating concepts with respect to customer needs and other criteria, comparing the relative strength and weaknesses of the concepts, and selecting one or more concepts for further investigation or development. To obtain the ideal concept o( new product, this work used a two-stage concept selection methodology which consist of concept screening and concept scoring. As a result, this study represents the fixed design rendering for mass production.

  • PDF

An Approach for a Substitution Matrix Based on Protein Blocks and Physicochemical Properties of Amino Acids through PCA

  • You, Youngki;Jang, Inhwan;Lee, Kyungro;Kim, Heonjoo;Lee, Kwanhee
    • Interdisciplinary Bio Central
    • /
    • v.6 no.4
    • /
    • pp.3.1-3.10
    • /
    • 2014
  • Amino acid substitution matrices are essential tools for protein sequence analysis, homology sequence search in protein databases and multiple sequence alignment. The PAM matrix was the first widely used amino acid substitution matrix. The BLOSUM series then succeeded the PAM matrix. Most substitution matrixes were developed by using the statistical frequency of substitution between each amino acid at blocks representing groups of protein families or related proteins. However, substitution of amino acids is based on the similarity of physiochemical properties of each amino acid. In this study, a new approach was used to obtain major physiochemical properties in multiple sequence alignment. Frequency of amino acid substitution in multiple sequence alignment database and selected attributes of amino acids in physiochemical properties database were merged. This merged data showed the major physiochemical properties through principle components analysis. Using factor analysis, these four principle components were interpreted as flexibility of electronic movement, polarity, negative charge and structural flexibility. Applying these four components, BAPS was constructed and validated for accuracy. When comparing receiver operated characteristic ($ROC_{50}$) values, BAPS scored slightly lower than BLOSUM and PAM. However, when evaluating for accuracy by comparing results from multiple sequence alignment with the structural alignment results of two test data sets with known three-dimensional structure in the homologous structure alignment database, the result of the test for BAPS was comparatively equivalent or better than results for prior matrices including PAM, Gonnet, Identity and Genetic code matrix.

Graded approach to determine the frequency and difficulty of safety culture attributes: The F-D matrix

  • Ahn, Jeeyea;Min, Byung Joo;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2067-2076
    • /
    • 2022
  • The importance of safety culture has been emphasized to achieve a high level of safety. In this light, a systematic method to more properly deal with safety culture is necessary. Here, a decision-making tool that can apply a graded approach to the analysis of safety culture is proposed, called the F-D matrix, which determines the frequency and the difficulty of safety culture attributes recently defined by the IAEA. A hierarchical model of difficulty contributors was developed as a scoring standard, and its elements were weighted via expert evaluation using the analytic hierarchy process. The frequency of the attributes was derived by analyzing reported events from nuclear power plants in the Republic of Korea. Period-by-period comparisons with the F-D matrix can show trends in the change of the maturity level of an organization's safety culture and help to evaluate the effectiveness of previously implemented measures. In the evaluating the difficulty of the attributes in the recently developed harmonized safety culture model, the difficulties of Trending, Benchmarking, Resilience, and Documentation and Procedures were found to be relatively high, while the difficulties of Conflicts are Resolved, Ownership, Collaboration, and Respect is Evident were found to be relatively low. A case study was conducted with an analysis period of 10 years to attempt to reflect the many changes in safety culture that have been made following the Fukushima accident in March 2011. As a result of comparing two periods following the Fukushima accident, the overall frequency decreased by about 40%, providing evidence for the effects of the various improvements and measures taken following the increased emphasis on safety culture. The proposed F-D matrix provides a new analytical perspective and enables an in-depth analysis of safety culture.

The application of simplified risk assessment for tunnel (터널 리스크 평가 기법의 적용성에 대한 연구)

  • Kim, Sang-Hwan;Lee, Chung-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • Unexpected ground conditions have always been a major problem for the construction of tunnel. Therefore, it is necessary to evaluate the risk capacity before and/or during construction of new tunnel. This paper presents the simplified risk assessment system using modified stability number (N), namely Underground Risk Index (URI) system, to evaluate the tunnel risk possibility in the design stage. URI is a scoring system for risk possibility by rating the each appraisal elements. The modified stability number (N) which is one of risk factor in the Interaction Matrix parameters such as RQD, UCS, weathering, overburden, stability number, ground water-table, RMR, permeability and so on, is used in the system. In addition, the case study is performed in order to verify the applicability of URI-system in practice.

  • PDF

Application of Quality Statistical Techniques Based on the Review and the Interpretation of Medical Decision Metrics (의학적 의사결정 지표의 고찰 및 해석에 기초한 품질통계기법의 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.243-253
    • /
    • 2013
  • This research paper introduces the application and implementation of medical decision metrics that classifies medical decision-making into four different metrics using statistical diagnostic tools, such as confusion matrix, normal distribution, Bayesian prediction and Receiver Operating Curve(ROC). In this study, the metrics are developed based on cross-section study, cohort study and case-control study done by systematic literature review and reformulated the structure of type I error, type II error, confidence level and power of detection. The study proposed implementation strategies for 10 quality improvement activities via 14 medical decision metrics which consider specificity and sensitivity in terms of ${\alpha}$ and ${\beta}$. Examples of ROC implication are depicted in this paper with a useful guidelines to implement a continuous quality improvement, not only in a variable acceptance sampling in Quality Control(QC) but also in a supplier grading score chart in Supplier Chain Management(SCM) quality. This research paper is the first to apply and implement medical decision-making tools as quality improvement activities. These proposed models will help quality practitioners to enhance the process and product quality level.

Second Look Arthroscopic Finding after Fibrin Matrix Autologous Chondrocyte Implantation for the Treatment of Articular Cartilage Defect of the Knee - Preliminary Report - (슬관절 연골 결손에 대한 fibrin matrix 자가 연골 세포 이식술 후 이차 관절경 소견 - 예비보고 -)

  • Choi, Sung-Wook;Oh, In-Suk;Kim, Ryuh-Sup;Park, Sun-Won;Lee, Jong-Min;Lee, Moon;Kim, Myung-Ku
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • Purpose: The purpose of this preliminary report is to investigate the short term outcome of performing gel type fibrin matrix autologous chondrocyte implantation to patients who have damaged knee joint cartilage using secondary arthroscopy. Material and Methods: Six patients who have damaged knee joint cartilage were involved. The average size of defect was $5.13\;cm^2$. While performing primary arthroscopy, whole layer of cartilage bone was obtained either from the margin of damaged cartilage or the bilateral margin of a trochlea. The cartilaginous cells were obtained for culture for four to six weeks. While performing secondary minimal invasive arthrotomy, gel type fibrin matrix autologous chondrocyte was implanted on the chondral defect site. Results: 4 among 6 patients to be more than good in Modified Cincinnati Knee Scoring system. Lysholm function score was 59.5 preoperatively, and it improved to 76.25. ICRS grading by performing secondary arthroscopy revealed 4 out of 6 patients to be nearly normal. Conclusion: Gel type fibrin matrix autologous chondrocyte implantation is a treatment for cartilage defect, which takes less time to operate than the conventional implantation. In addition, this method minimizes the size of incision and allows arthroscopic surgery. However, long term follow up and more case study is thought to be necessary.

  • PDF

AN IMPROVED ALGORITHM FOR RNA SECONDARY STRUCTURE PREDICTION

  • Namsrai Oyun-Erdene;Jung Kwang Su;Kim Sunshin;Ryu Keun Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.280-282
    • /
    • 2005
  • A ribonucleic acid (RNA) is one of the two types of nucleic acids found in living organisms. An RNA molecule represents a long chain of monomers called nucleotides. The sequence of nucleotides of an RNA molecule constitutes its primary structure, and the pattern of pairing between nucleotides determines the secondary structure of an RNA. Non-coding RNA genes produce transcripts that exert their function without ever producing proteins. Predicting the secondary structure of non-coding RNAs is very important for understanding their functions. We focus on Nussinov's algorithm as useful techniques for predicting RNA secondary structures. We introduce a new traceback matrix and scoring table to improve above algorithm. And the improved algorithm provides better levels of performance than the originals.

  • PDF

Debris Flow Risk Evaluation and Ranking Method for Drainage Basin adjacent to Road (도로인근 유역의 토석류 위험평가 및 등급화 방안)

  • Kim, Kyung-Suk;Jang, Hyun-Ick
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.279-290
    • /
    • 2010
  • Technical countermeasures against debris flow should be established upon the risk level of the target location. Risk of debris flow should consider the hazard imposed by debris flow and vulnerability of the facilities to debris flow. In this research, we have defined the target location for risk evaluation and suggested scoring method of hazard of debris flow and vulnerability of road to debris flow. By defining risk rank into 6 categories in terms of possibility of damage during rainfall and using the risk scores of 46 debris flow cases, we have suggested risk ranking matrix. The method can be used in ranking the drainage basin adjacent to road by simply determining the hazard with vulnerability score and can be used for planning the debris flow countermeasures.

  • PDF

VALIDATION AND UTILIZATION OF THE SKINTEXTM SYSTEM

  • Gordon, V.C.;Realica, B.;Tolstrup, K.;Puls, B.
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.17 no.1
    • /
    • pp.64-80
    • /
    • 1991
  • The SKINTEX Method is based on a two-compartment physico-chemical model which includes a Biomembrane Barrier in compartment one and an organized macromolecular matrix in compartment two. Test samples absorb onto or permeate through the keratin/collagen Biomembrane Barrier and then can interact with the organized macromolecular matrix. Changes in the integrity of the barrier release a dye indicator: Changes in the matrix can alter its transparency. The sum of these two responses is read spectrophotometrically at 470nm. An early investigation of 950 chemicals and formulations in the SKINTEX System produced results which were 89% concordance to in vivo Draize dermal irritation results obtained with 24-hour occluded application of test samples with-out abrasion and standard scoring. Alkaline materials were analyzed in a specialized SKINTEX AMA Protocol. In this early study, the model did not distinguish nonirritant test materials and formulation with PDII(Primary Dermal Irritation Index)in the range from 0 to 1.2, A High Sensitivity Assay Protocol(HSA)was developed to amplify the changes in both compartments of this model and provide more accurate calibration of these changes. A study of 60 low irritation test samples including cosmetics, household products, chemicals and petro-chemicals distinguished nonirritants with PDII $\leq$ 0.7 for 26 of 30 nonirritants. A second protocol was developed to evaluate the SKINTEX model predictability with respect to human irritation. The Human Response Assay (HRA )has been optimized based on differences in penetration and irritation responses in humans and rabbits. An additional 32 test materials with different mechanisms and degrees of dermal toxicity were evaluated by the HRA. These in vitro results were 86% concordant to human patch test results. In order to further evaluate this model, a Standard Chemical Labelling (SCL) Protocol was developed to optimize this system to predict Draize dermal irritation results after a 4-hour application of the test material. In a study of 52 chemicals including acids, bases, solvents, salts, surfactants and preservatives, the SCL results demonstrated 85% concordance to Draize results for a 4-hour application of test samples on non-abraded rabbit skin. The SKINTEX System, including three specialized protocols, provided results which demonstrated good correlation to the endpoint of dermal irritation in man and rabbits at different application times.

  • PDF