• Title/Summary/Keyword: scintimammography (SMM)

Search Result 2, Processing Time 0.02 seconds

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Comparison of Tc-99m-Tetrofosmin and Tc-99m-MIBI Scintimammography in Differential Diagnosis of Breast Mass (유방종양의 감별진단에서 Tc-99m-Tetrofosmin과 Tc-99m-MIBI 유방신티그라피의 비교)

  • Park, Jung-Mi;Choi, Joon-Young;Lee, Kyung-Han;Choi, Yong;Choe, Yearn-Seong;Kim, Sang-Eun;Kim, Byung-Tae;Nam, Seok-Jin;Yang, Jeong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.393-402
    • /
    • 2000
  • Purpose: Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the diagnosis of breast mass. Materials and Methods: The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. Results: The SMM a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at 3 hr. first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIBI TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MIBI TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not sensitivity and specificity between MIBI and TF SMM. Conclusion: The ability for the differential of breast tumor is similar between MIBI and TF SMM, and delayed image is not necessary. TF may be than MIBI considering the specificity of SMM without clinical information and labeling convenience.

  • PDF