• 제목/요약/키워드: school Size

검색결과 8,754건 처리시간 0.043초

학교(學校) 스포츠홀의 적정규모(適定規模) 범위설정(範圍設定)에 관한 연구(硏究) - 일본(日本), 영국(英國), 독일(獨逸), 미국(美國)의 체육시설(體育施設) 규정(規定)을 중심(中心)으로 - (A Study on Establishing the Range of Optimum Size for School Sports Hall - Focused on the regulations of sports facilities in Japan, England, Germany, U.S.A -)

  • 김효일
    • 교육시설
    • /
    • 제7권3호
    • /
    • pp.23-35
    • /
    • 2000
  • Today the supply of school sports halls for multi-functional use is absolutely insufficient in school facilities of Korea. For economical reasons and efficiency of use, a joint utilization of these halls by schools, sports clubs and other users should be strived for. This will lead, as a result, to a minimization overall in the demand for halls. Above all to satisfy this demand, the regulations of sports facilities suitable to the students' standards of play and physical conditions must be preceded in Korea. And a study on the architectural planning of this hall size for primary, middle and high school is needed. This study aims at establishing the range of optimum size of school sports hall in Korea by surveying and analyzing the regulations of sports facilities about clear height of hall, obstacle-free zone and court area in Japan, England, Germany and U.S.A. Therefore, this study will offer valuable basic data in planning the school sports hall.

  • PDF

습식 환원법에 의한 Ni 분말 합성시 반응조건의 영향 (The Effect of Reaction Conditions on the Preparation of Ni Powder Using Wet Chemical Reduction Process)

  • 김동현;박영민;김이중;진형호;박홍채;윤석영
    • 한국재료학회지
    • /
    • 제14권10호
    • /
    • pp.725-730
    • /
    • 2004
  • Nickel ultrafine powder have been synthesized by chemical reduction of aqueous $NiSO_4$ with hydrazine at various reaction conditions. The effect of reaction conditions such as the amount of surfactant and reductor, and reaction temperature on the particle size and shape was investigated by the mean of XRD, SEM and SEM-PSA. Experiments showed that the ratio of $N_{2}H_4/Ni$ and the reaction temperature were affected on the particle size of the nickel powder. The average particle size of synthesized nickel powder increased with increasing reaction temperature regardless of the ratio of $N_{2}H_4/Ni$. Also the surfactant could influence the size and agglomeration of ultrafine powder with the reaction temperature.

CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰 (A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT)

  • 방승재;김영연;정일선;김정수;김영곤
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.175-180
    • /
    • 2013
  • 목 적: 방사선치료에 있어 환자자세 설정(Set-up) 오차를 줄이기 위하여 많은 장비들이 개발되어 왔다. CBCT 촬영은 Set-up 오차를 줄이고, 정확한 치료를 수행하는 최신 방법 중 하나이다. CBCT의 조사야를 조절하여 영상의질(Image quality) 향상과 피폭선량을 측정하고 분석함으로써 임상에서 최적화하여 사용할 수 있는 치료조사야(Field size)를 제시하고자 한다. 대상 및 방법: Catphan phantom을 이용하여 Half fan, Full fan mode로 조사야를 2~16 cm까지 2 cm 간격으로 촬영하였다. Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (14 cm 이상)으로 구분하여 Image quality를 평가하였다. CTDi는 CTDi phantom과 Ion chamber를 이용하여 측정 및 분석하였다. 결 과: CT값 일치도(CT number linearity)는 Small, Large field size에서 촬영한 값이 Medium field size보다 크게 나타났다. 공간분해능(Spatial resolution)은 Full fan에서 Small field size촬영을 제외하고 나머지 Field size에서 크게 차이가 나지 않았다. Half fan에서는 많은 차이를 보였다. CT 값 균일도(HU uniformity)는 Full fan에서는 Medium size를 제외하고는 제조사에서 권고하는 값을 초과하였으며, Half fan에서는 모든 Field size가 Full fan에서는 Medium field size에서는 안정된 값으로 분석되었다. CT 피폭선량(CTDi)는 Medium field size에서 증가 할수록 루트함수의 그래프의 형태로 나타났다. 결 론:Small field size에서는 Image quality와 실용성의 측면에서도 적절하지 않은 것으로 사료된다. Medium field size는 Large field size에서 보다 Image quality도 우수하고 환자의 피폭선량을 줄일 수 있으므로 본 논문에서는 CBCT 촬영 시 Field size 8~10 cm 촬영이 유용하다고 사료된다.

  • PDF

초등학교 교사의 교실환경 인식에 관한 연구 (A Study on the Elementary School Teachers' Perceptions of Classroom Environments)

  • 석민철;신나민;류호섭
    • 교육시설 논문지
    • /
    • 제20권6호
    • /
    • pp.21-30
    • /
    • 2013
  • This study aimed to identify elementary school teachers' perceptions of various aspects of physical environments of a classroom. For the purpose, a survey questionnaire was administered to 982 classroom teachers(female 82.2%) working at 67 elementary schools(Seoul 55%) located in Seoul and Busan. According to the analyses of the survey data, 50.8% of the respondent teachers suggested 20-25 as an optimum class size. Also, 57% of the teachers were positive about the current size of a classroom($67.5m^2$), but evaluations of a classroom size were divided between the teachers who had more and less than 30 students in class. Furthermore, three factors, labelled as 'uniqueness', 'residential stability' and 'visually pleasing', were extracted from a factor analysis of the Semantic Differential Scale consisting of 24 adjectives evaluating a classroom environment. Teachers from Busan tended to rate higher in the uniqueness domain while female teachers scored higher in the domain of residential stability, respectively, compared to their counterparts. Overall, the teachers perceived their classrooms having no particular characteristics, but rated highly in terms of stability. In addition, it was found out that the teachers' requests for the improvement of a classroom environment were not so much as the increased size of a classroom as a reduced class size as well as educational facilities that are corresponding to a variety of instructional methods. In summary, this study confirmed that elementary school teachers' perceptions of a classroom environment varied according to such factors as sex, teaching career, grade of their concerned class, and class size.

Porosity and pore size distribution in high-viscosity and conventional glass ionomer cements: a micro-computed tomography study

  • Aline Borburema Neves ;Laisa Inara Gracindo Lopes;Tamiris Gomes Bergstrom;Aline Saddock Sa da Silva ;Ricardo Tadeu Lopes ;Aline de Almeida Neves
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.57.1-57.9
    • /
    • 2021
  • Objectives: This study aimed to compare and evaluate the porosity and pore size distribution of high-viscosity glass ionomer cements (HVGICs) and conventional glass ionomer cements (GICs) using micro-computed tomography (micro-CT). Materials and Methods: Forty cylindrical specimens (n = 10) were produced in standardized molds using HVGICs and conventional GICs (Ketac Molar Easymix, Vitro Molar, MaxxionR, and Riva Self-Cure). The specimens were prepared according to ISO 9917-1 standards, scanned in a high-energy micro-CT device, and reconstructed using specific parameters. After reconstruction, segmentation procedures, and image analysis, total porosity and pore size distribution were obtained for specimens in each group. After checking the normality of the data distribution, the Kruskal-Wallis test followed by the Student-Newman-Keuls test was used to detect differences in porosity among the experimental groups with a 5% significance level. Results: Ketac Molar Easymix showed statistically significantly lower total porosity (0.15%) than MaxxionR (0.62%), Riva (0.42%), and Vitro Molar (0.57%). The pore size in all experimental cements was within the small-size range (< 0.01 mm3), but Vitro Molar showed statistically significantly more pores/defects with a larger size (> 0.01 mm3). Conclusions: Major differences in porosity and pore size were identified among the evaluated GICs. Among these, the Ketac Molar Easymix HVGIC showed the lowest porosity and void size.

CAD 시스템을 활용한 여중생의 슬랙스 패턴 그레이딩에 관한 연구 (A Study on the Junior-High School Girls' Slacks Pattern Grading by Using Apparel CAD System)

  • 임지영
    • 대한가정학회지
    • /
    • 제40권11호
    • /
    • pp.1-9
    • /
    • 2002
  • Nowadays, the use of apparel CAD system is important to the mass production of ready to wear Especially, computer-based grading is the most important process to improve the fitness of clothes and to reduce the time needed to make patterns of several sizes. The purpose of this study was to suggest a standard sizing system for junior-high school girls' lower clothes and to suggest a grading method according to the sizing systems. The subjects were 402 junior-high school girls of 13 to 15 year's-old. The size intervals of waist girth and hip girth were 3㎝ and 4㎝ respectively. The sizing system, which had frequencies more than 4.5%, was classified 8 cases. For regular grading, two types of group were classified into 58-82/61-86/64-90/67-94 and 61-82/64-86/67-90/70-94. Among them, 61-86 and 64-86 size were adopted the basic size for the development of grading. According to the sizing system, hand-made patterns were manufactured. By measure of the each part of the slacks, new grading rule patterns were developed by each size. A new grading rule was different from the Moonwha grading rule. This result will contribute to clothing fitness of consumer and the amount of production.

An Optimized CLBP Descriptor Based on a Scalable Block Size for Texture Classification

  • Li, Jianjun;Fan, Susu;Wang, Zhihui;Li, Haojie;Chang, Chin-Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.288-301
    • /
    • 2017
  • In this paper, we propose an optimized algorithm for texture classification by computing a completed modeling of the local binary pattern (CLBP) instead of the traditional LBP of a scalable block size in an image. First, we show that the CLBP descriptor is a better representative than LBP by extracting more information from an image. Second, the CLBP features of scalable block size of an image has an adaptive capability in representing both gross and detailed features of an image and thus it is suitable for image texture classification. This paper successfully implements a machine learning scheme by applying the CLBP features of a scalable size to the Support Vector Machine (SVM) classifier. The proposed scheme has been evaluated on Outex and CUReT databases, and the evaluation result shows that the proposed approach achieves an improved recognition rate compared to the previous research results.

TRIZ 기법을 통한 휴대가 용이한 Drone 설계 (Portable-size Drone Design Using TRIZ Method)

  • 김종형;김형직;정재남;장동휘;권혁동
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.230-237
    • /
    • 2017
  • Various drones have extended application area very fast. In this paper, we define two contradictions in designing a portable-size drone by using TRIZ technique. The first is a physical contradiction between high rigidity and good portability, and the second is a technical contradiction between high stability and good portability. Through TRIZ technique, six design principles, which guide direction for optimal design, were driven. Consequently, an umbrella mechanism and design criteria were proposed for a portable-size drone. Detail design is verified through finite element method. Test results for the portable-size prototype drone show good performance, and prove its usefulness to be equivalent to a general full-size drone.

마이크로에멀젼을 이용한 은 나노입자의 합성 (Synthesis of Silver Nanoparticles by Microemulsion)

  • 윤인영;박흥조;곽광수;정노희
    • 한국응용과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.118-124
    • /
    • 2003
  • Silver nanoparticles was synthesized by the method of W/O microemulsions with AOT (bis(2-ethylhexyl) sodium sulfosuccinate). The nucleation particle growth and aggregation was controlled by the droplet exchange process. The intermicellar exchange reaction is varied by changing the AOT and the $H_2O$ concentration. The synthesized W/O microemulsions was found to give the nanoparticles, which was confirmed by SEM, TEM, particle-size-analyzer, and UV-spectrometer. The most stable particles was obtained at 0.056 mole AOT solution, and the particle size distribution was found in the range from 27 to 31 nm. The mean particle size was reduced by adding Tween 20 significantly, and distribution was found from 14 to 16 nm. And, It's size was reduced by cosurfactants as toluene and benzyl alcohol. In case of toluene and benzyl alcohol, the range of particle size was found 7${\sim}$11 nm and 8${\sim}$12 nm.

An Experimental Study on Angled Injection and Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow

  • Kim, Min-Ki;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.486-491
    • /
    • 2008
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomizer internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD(Sauter Mean Diameters) distribution by using PLLIF(Planar Liquid Laser Induced Fluorescence) technique. The objectives of this research are getting a droplet distribution and drop size measurement of each condition and compare with the other flows effect. As the result, This research have been showed the droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects and normalized distance from the injector exit length.(x/d, y/d)There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF