• Title/Summary/Keyword: scattering distance

Search Result 175, Processing Time 0.026 seconds

Optical Sensor of Coplanar Structure Study and Design for Intravenous Solution Exhaustion Alarm System (수액 소진 알람시스템을 위한 동일평면형 광센서의 연구 및 제작)

  • Park, Hyo Soon;Kim, Tae Yun;Jung, Eui Sung;Seong, Ki Woong;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.113-118
    • /
    • 2015
  • Intravenous (IV) infusion set is one of the most common treatment methods applied to hospitalized patients. However, it is necessary to check the injection of IV solution in order to prevent patients from any possible medical injuries. In this paper, using the optical sensors to detect exhaustion of IV solution was proposed. The optical sensor is coplanar structure composed of LED and photodiode which is installed according to focal distance of the lens. These two elements detect exhaustion of IV solution at the desired point conveniently. Through the results of experiments using various wavelength of LED (R.G.B), the blue LED was selected to the optimum light source. The suggested optical sensor can detect exhaustion of IV solution by the differences in the amount of light which is caused by properties such as total reflection, refractive index and scattering. From the implementation, the detector is applicable to both containers of IV solution, glass bottle and plastic pack. And also the result shows apparent differences according to existence of IV solution even if the IV solution color and illumination were changed.

Shallow Water Acoustic Communication Channel Characteristic Analysis Using PN Sequence with 25 kHz Carrier at the Shore of Geojea Island (25 kHz 대역에서 PN 신호열을 이용한 거제 천해역 수중음향통신 채널 특성 분석)

  • Kim, Jae-Gap;Kim, Sea-Moon;Lim, Young-Kon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.381-389
    • /
    • 2007
  • In this paper, the measuring method of underwater acoustic communication channel characteristics in the shallow water using the autocorrelation characteristic of PN sequence and the undorwater communication channel analysis results from the received signal sample data are described. For measuring the underwater acoustic communication channel characteristics, two PN sequences are used as a transmitted data of I-channel and Q-channel of QPSK symbol and QPSK signal is transmitted with symbol rate of 5 kHz and carrier frequency of 25 kHz. In the receiver the received signal, which pass through 675 m and 1492 m, is sampled and then stored. Using the stored sample data, the scattering function, coherent time, delay power profile, spaced-tone autocorrelation function, delay spread, and coherent bandwidth of each propagation distance cases are analyzed. Based on the analysis results, several guidelines are suggested for the design and implementation of underwater transmission system.

Three-Dimensional Approaches in Histopathological Tissue Clearing System (조직투명화 기술을 통한 3차원적 접근)

  • Lee, Tae Bok;Lee, Jaewang;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • Three-dimensional microscopic approaches in histopathology display multiplex properties that present puzzling questions for specimens as related to their comprehensive volumetric information. This information includes spatial distribution of molecules, three-dimensional co-localization, structural formation and whole data set that cannot be determined by two-dimensional section slides due to the inevitable loss of spatial information. Advancement of optical instruments such as two-photon microscopy and high performance objectives with motorized correction collars have narrowed the gap between optical theories and the actual reality of deep tissue imaging. However, the benefits gained by a prolonged working distance, two-photon laser and optimized beam alignment are inevitably diminished because of the light scattering phenomenon that is deeply related to the refractive index mismatch between each cellular component and the surrounding medium. From the first approaches with simple crude refractive index matching techniques to the recent cutting-edge integrated tissue clearing methods, an achievement of transparency without morphological denaturation and eradication of natural and fixation-induced nonspecific autofluorescence out of real signal are key factors to determine the perfection of tissue clearing and the immunofluorescent staining for high contrast images. When performing integrated laboratory workflow of tissue for processing frozen and formalin-fixed tissues, clear lipid-exchanged acrylamide-hybridized rigid imaging/immunostaining/in situ hybridization-compatible tissue hydrogel (CLARITY), an equipment-based tissue clearing method, is compatible with routine procedures in a histopathology laboratory.

Surface Dose Evaluation According to the Environment Around the Patient after Nuclear Medicine Examination (핵의학 검사 후 환자의 주위 환경에 따른 표면 선량 평가)

  • Lee, Young-Hee;Park, Jae-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.943-948
    • /
    • 2021
  • The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18F by injecting 20 and 10 mCi respectively into the NEMA phantom, and then measuring the surface dose for 60 minutes by positioning the phantom at a height of 1 m above the surface, at a distance of 0, 5 and 10 cm from the wall, and at the same location as the phantom facing the wall. Each experiment was repeated five times for reproducibility of the experiment and one way analysis of variability (ANOVA) was performed for significance testing and Tukey was used as a post-test. The study found that surface doses of 220.268, 287.121, 243.957, and 226.272 mGy were measured at 99mTc, respectively, in the case of empty space and in the case of 0, 5 and 10 cm, while those of 18F were measured at 637.111, 724.469, 657.107, and 640.365 mGy, respectively. In order to reduce changes in surface dose depending on the patient's location while waiting, it is necessary to keep the distance from the ground or the wall where the patient is closely adhered to, or install an air mattress, etc., to prevent the scattered lines as much as possible, considering the scattered lines due to the wall etc. in future setup of the patient waiting room and safety room, and in addition to the examination, the external skin width may be reduced.

Analysis of the Engagement Effects of DIRCM against a Man Portable Air Defense System (휴대용대공유도탄에 대응하는 지향성적외선방해장비의 교전효과 분석)

  • Jeong, Chunsik
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.139-147
    • /
    • 2019
  • A MANPADS(Man Portable Air Defense System), which tracks infrared energy, is light enough for individuals to carry and can against to a variety of aircraft, making it widely deployed around the world, posing a major threat to aircraft. A flare has been developed as an IRCM(Infrared Countermeasures) that protects the life of friendly aircraft and combatants by deceiving such guided missiles. However, DIRCM, which can overcome the problems of existing IRCM, is being developed mainly in some developed countries, and the need for it has been increasing gradually. This paper modeled first generation IR seeker of AM modulation method, the second generation IR seeker of FM modulation method, and the third generation IR seeker of pulse modulation method among various MANPADS, and modeled the scattering light phenomenon in the seeker when laser beams are investigated in DIRCM. Using this, jamming simulations were performed in various engagement environments of the MANPADS and aircraft equipped with DIRCM, and the miss distance of the guided missiles and aircraft were analyzed. Simulation results show that DIRCM, which irradiates a modulated laser beam with one jamming code, deceives both first, second and third generation MANPADS at 1km and 2km of engagement distance. In particular, the survival rate of aircraft equipped with DIRCM increased when the distance of engagement increased from 1km to 2km, and the survival rate was at least 99% at 2km of engagement distance.

He II RAMAN SCATTERED LINE BY NEUTRAL HYDROGEN IN THE BIPOLAR PLANETARY NEBULA M2-9 (나비형 행성상 성운 M2-9에서 He II의 중성 수소에 의한 라만 산란선)

  • 이희원;강영운
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • In the spectrum of the young bipolar planetary nebula M2-9 obtained from the 1.5m telescope at the Cerro Tololo Inter-American Observatory, we detected the He II feature at 6545 $\AA$ that are proposed to be formed via Raman scattering by atomic hydrogen. However, in the same spectrum, the He II emission lines at 6527 $\AA$ and 6560 $\AA$ are absent, which implies that the He II emission region is hidden from our line of sight and that the H I scattering region is pretty much extended not to be obscured entirely. We performed photoionization computations to estimate the physical size of the He II emission line region to be $10^{16}cm$, from which the location and dimension of the obscuring circumstellar region are inferred and the temperature of the central star must exceed $10^5K$. The angular size of the circumstellar region responsible for the obscuration of the He II emission region is ~1" with the assumption of the distance 01 kpc to M2-9, which is consistent with the recent image of M2-9 obtained with the Hubble Space Telescope.

  • PDF

A Small-Angle Neutron Scattering Study for Sizes and Structures of Micelles and Vesicles Formed in Aqueous Solutions of Mixed Surfactants ADS/OTAC (ADS/OTAC 혼합 계면활성제 수용액에서 형성된 마이셀과 층막구형체의 크기 및 구조에 대한 작은 각 중성자 산란 연구)

  • Kim, Hong-Un;Lee, Jin-Kyu;Lim, Kyung-Hee
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.231-237
    • /
    • 2005
  • The sizes and structure of micelles and vesicles formed in ammonium dodecyl sulfate (ADS)/octadecyl trimethyl ammonium chloride (OTAC) mixed aqueous solutions were analyzed by small-angle neutron scattering. In micellar regions of pure ADS and OTAC aqueous solution, the spherical micelles were formed at given concentrations and their sizes were 40 and $61{\AA}$, respectively. The structure transition of pure micelles occurred above 300 mM due to the constancy of the intermicellar distance above 250 mM. The coexisting region of mixed micelles and vesicles in phase diagram of mixed system was also assured. It was investigated that vesicle formed spontaneously took a bilayer structure. The lamellar thickness of vesicles decreased with increasing concentration of vesicle samples. However, the size could not be determined for mixed micelle and vesicle above 100 nm due to limitation of low q ranges. Finally, The 9 mM solution of ADS mole fraction 0.9 (${\alpha}$=0.9) showed bilayer structure compared to phase diagram classified into mixed micelle.

Underwater Laser Communication Using LDPC Coded Method (LDPC 부호화 기술을 이용한 수중 레이저 통신)

  • Lee, A-Hyun;Baek, Chang-Uk;Lee, Dong-Hun;Jung, Ji-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.246-252
    • /
    • 2018
  • Recent studies have been received much attention on underwater laser communication, which is capable of high data rate. However, in underwater laser communication, distortions caused by absorption and scattering induced performance degradation. A typical way to improve performance is to apply channel coding technique. In the beginning of studies, simple methods such as RS and BCH coding techniques were applied. However, due to distance expansion and performance improvement, channel coding methods with low error probability such as LDPC coded method were applied. In this paper, we analyzed the performance according to the size of the code word N, the distance between the transceivers and the size of the M of the M-ary PPM modulation scheme. Simulation results show that parameter M of M-ary PPM is most effect on performance.

A study on Behavior of Turbulent Transient Jets with Butane and Propane (Butane 및 propane의 비정상 난류 제트 특성에 관한 연구)

  • Lee, Beom-Ho;Song, Hak-Hyun;Cho, Seung-Hwan;Hong, Sung-Tae;Lee, Dae-Yup;Lee, Tae-Woo
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.74-82
    • /
    • 2010
  • In order to understand the behavior of transient gaseous injection used in an LPG (Liquefied Petroleum Gas) engine, turbulent incompressible transient jets with butane and propane were measured and analyzed at pressures of 1.5 bar and 2.0 bar with injector diameters of 3 mm and 5 mm. Mie-scattering method with a tracer was used, and images were processed to investigate the behavior of butane and propane jets. Distances from the nozzle to transition region were measured as $L_e/d_{inj}$=4.35~19.4, where $L_e$ and $d_{inj}$ indicate respectively a distance from nozzle to transition point and nozzle diameter. Slits and tubes around jet at near-field were introduced to measure the effect of entrainment and the diameter of jet, which revealed that the entrainment of surrounding air is significant for developing jet diameter. When the entrainment is restricted, the behavior of jet became deviating from the baseline. It was found that the virtual origin located outside of a nozzle towards jet tip within the conditions of this work, and its location was estimated as $x_o/d_{inj}$=0.56~7.25, where $x_o$ is a distance from nozzle to virtual origin.

Design and Implementation of VLID System by Back-Scattering Visible Light (가시광의 후방산란을 이용한 VLID 시스템 설계 및 구현)

  • Yun, Jisu;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.10-18
    • /
    • 2017
  • In this paper, we designed and implemented a visible light identification(VLID) system consisting of a VLID reader and a tag which backscatters incident lights from the reader. A VLID tag sends its ID to the reader by switching an LCD shutter which is located on its surface. The VLID reader consists of six LEDs and a photodiode(PD). The LEDs emit visible light and a PD located in a center position of LEDs receives backscattered light from the VLID tag. A microcontroller and a commercial liquid crystal display(LCD) shutter for 3D-TV glasses are used to implement a VLID tag. Experiments were conducted to confirm VLID system performance. We successfully demonstrated experiments to send NRZ-OOK signal of 100 bps over a distance of 35 cm at daytime. Also, we suggested the theoretical maximum transmission rate and the various methods to enhance the separation distance between a VLID reader and a tag.