• Title/Summary/Keyword: scatter reduction

Search Result 47, Processing Time 0.021 seconds

Probability Distribution Characteristics for Elevated Temperature Mechanical Properties of Stainless Steels (스테인리스강의 고온 기계적 성질에 대한 확률분포 특성)

  • 김선진;곽명규;권상우;공유식
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.64-69
    • /
    • 2004
  • The characteristics of the probability distribution for mechanical properties, e.g. tensile strength, reduction of area, and elongation, for STS304 stainless steel in elevated temperature are investigated. Tensile test is performed by constant crosshead speed controls with 1mm/min. The probability distribution function of measured mechanical properties seems to follow $\alpha$ 3-parameter Weibull, and shows a slight dependence on the temperature. When the temperature is raised, the shape parameter a is increased, but both the scale parameter $\beta$ and location parameter v are decreased.

Experimental Comparisons of Simplex Method Program's Speed with Various Memory Referencing Techniques and Data Structures (여러 가지 컴퓨터 메모리 참조 방법과 자료구조에 대한 단체법 프로그램 수행 속도의 비교)

  • Park, Chan-Kyoo;Lim, Sung-Mook;Kim, Woo-Jae;Park, Soon-Dal
    • IE interfaces
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 1998
  • In this paper, various techniques considering the characteristics of computer memory management are suggested, which can be used in the implementation of simplex method. First, reduction technique of indirect addressing, redundant references of memory, and scatter/gather technique are implemented, and the effectiveness of the techniques is shown. Loop-unrolling technique, which exploits the arithmetic operation mechanism of computer, is also implemented. Second, a subroutine frequently called is written in low-level language, and the effectiveness is proved by experimental results. Third, row-column linked list and Gustavson's data structure are compared as the data structure for the large sparse matrix in LU form. Last, buffering technique and memory-mapped file which can be used in reading large data file are implemented and the effectiveness is shown.

  • PDF

Distribution of the Scatter Ray in Fluoroscopy X-ray Room (투시 검사실 내 공간산란선 분포 측정)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.349-354
    • /
    • 2011
  • The results of the scattery distribution in the fluoroscopy X-ray room were as follows. When the measurement was done at the same height with the table, measured value was 0.78 mGy/min ~ 0.04 mGy/min (95%) within 50 cm and 250 cm. At 50 cm below the table, it was 0.17 mGy/min ~ 0.02mGy/min (86%) and at 50 cm above the table was 1.37 mGy/min ~ 0.05 mGy/min (96%), displaying a decrease. At the same time, the amount of rays were reduced in 50 ~ 60% at the same height with the table than the location 50 cm above the table, 90~95% of reduction rate was observed at 50 cm below the table. For the collimator, comparing to the case when it was completely open, the amount of ray was reduced from 0.78 mGy/min to 0.16 mGy/min at 50cm away and 0.04 mGy/min to 0.01 mGy/min at 250cm away thus approximately 80% on average was reduced when the collimator was reduced to 25%. Comparing with the case when there was a object on the table, the amount of scatter ray was reduced by 96.7% at every location when there is not a object on the table.

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

A Study of Accuracy Improvement for Scattering Analysis of FMM Method (FMM 기법의 산란해석 정확도 향상 연구)

  • Kim, Young-joo;Cho, Young-Ki;Son, Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.972-982
    • /
    • 2001
  • FMM(Fast Multipole Method) is suitable numerical method for radar cross section calculation of arbitrary large conducting bodies due to reduction of computation time. The accuracy of the numerical results, however, can influenced by selection of grouping method and segment length, in particular, far the case that cross section of the scatter is of the narrow width elliptical type. So, we describe the FMM method which can be deal effectively with such difficulties for both TM and TE polarization case. In order to check the present method the results are compared with those obtained by Method of Moments.

  • PDF

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

New strut-and-tie-models for shear strength prediction and design of RC deep beams

  • Chetchotisak, Panatchai;Teerawong, Jaruek;Yindeesuk, Sukit;Song, Junho
    • Computers and Concrete
    • /
    • v.14 no.1
    • /
    • pp.19-40
    • /
    • 2014
  • Reinforced concrete deep beams are structural beams with low shear span-to-depth ratio, and hence in which the strain distribution is significantly nonlinear and the conventional beam theory is not applicable. A strut-and-tie model is considered one of the most rational and simplest methods available for shear strength prediction and design of deep beams. The strut-and-tie model approach describes the shear failure of a deep beam using diagonal strut and truss mechanism: The diagonal strut mechanism represents compression stress fields that develop in the concrete web between diagonal cracks of the concrete while the truss mechanism accounts for the contributions of the horizontal and vertical web reinforcements. Based on a database of 406 experimental observations, this paper proposes a new strut-and-tie-model for accurate prediction of shear strength of reinforced concrete deep beams, and further improves the model by correcting the bias and quantifying the scatter using a Bayesian parameter estimation method. Seven existing deterministic models from design codes and the literature are compared with the proposed method. Finally, a limit-state design formula and the corresponding reduction factor are developed for the proposed strut-andtie model.

Photoelectric Observation of the Long-Period Eclipsing Binaries at Yonsei University Observatory

  • Nha, Il-Seong;Lee, Yong-Sam;Chun, Yong-Woo;Kim, Ho-Il;Kim, Young-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.1-13
    • /
    • 1986
  • A long-term project(ten-year ; 1982-92) for the photoeletric observation in the UBV passbands of selected eclipsing binaries with P$\geq$10 days has initiated at Yonsei University Observatory using 40-cm and 61-cm reflectors. the instrumentatio used and the observation techniques and the reduction procedures applied to this investiagation are described. Out of 39 program stars, successful results have been obtained during our first two years for the 11 stars listed below, with the orbital period in days in the parenthesis, and the incomplete light curves of these stars are presented. SX Cas (36.57) AQ Cas (11.72) UU Cnc (96.71) RY Gem (9.30) V373 Cas (13.42) NY Cep (15.28) RX Cas (32.32) V396 Cas (15.28) ZZ Cnc (25.60) Zet Aur (982.2) Eps Aur (9885.) For the rest of the stars, the observations made in the first two years are not sufficient to attempt any meaning light curve construction ; some of the data are too fragmented and others show large scatter.

  • PDF

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure (중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석)

  • Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF