• Title/Summary/Keyword: scan-lines

Search Result 139, Processing Time 0.026 seconds

Prediction of Postpneumonectomy Pulmonary Function by Lung Scan in Lung Cancer Patient (폐관류스캔을 이용한 폐암환자의 일측 전폐절제술후의 폐기능예측)

  • Hur, Jin;Jang, Bong-Hyun;Lee, Jong-Tae;Kim, Kyu-Tae
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.338-344
    • /
    • 1991
  • If the postoperative pulmonary function can be predicted in the patients undergoing pneumonectomy for lung cancer preoperatively, it will be helpful for identifying them as high or low risk candidates. Perfusion lung scan and spirometry were performed in 12 patients with lung cancer pre-operatively and the predicted postoperative Vital Capacity, FVC, FEV1.0, FEF25 - 75% and MVV were estimated by multiplying the preoperative values by the percentage of perfusion of the nonsurgical lung. Three months postoperation the patients were reinvestigated with spirometry and the obtained values were compared with the predicted values. The linear regression lines derived from the correlation between predicted values [X] and observed values [Y] were as follows; VC; R=0.532, Y=0.48X+1.28, P=0.075 FVC; R=0.566, Y=O 54X+1.15, P=0.055 FEV1.0; R=0.832, Y=0.68X+0.70, P=0.001 FEF25 ~ 75%; R=0.781, Y=0.68X+0.54, P=0.003 MVV; R=0.718, Y=0.67X+34.75, P=0.009 The prediction of postoperative FEV1.0, FEF25 ~ 75% and MVV in lung cancer patients undergoing pneumonectomy appear to be valid for evaluating preoperative pulmonary function.

  • PDF

The Standard Processing of a Time Series of Imaging Spectral Data Taken by the Fast Imaging Solar Spectrograph on the Goode Solar Telescope

  • Chae, Jongchul;Kang, Juhyeong;Cho, Kyuhyoun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.46.1-46.1
    • /
    • 2018
  • The Fast Imaging Solar Spectrograph (FISS) on the Goode Solar Telescope (GST) at Big Bear Solar Observatory is the imaging Echelle spectrograph developed by the Solar Astronomy Group of Seoul National University and the Solar and Space Weather Group of Korea Astronomy and Space Science Institute. The instrument takes spectral data from a region on the Sun in two spectral bands simultaneously. The imaging is done by the organization of intensity data obtained from the fast raster scan of the slit over the field of view. Since the scan repeats many times, the whole set of data can be used to construct the movies of monochromatic intensity at arbitrary wavelengths within the spectral bands, and those of line-of-sight velocity inferred from different spectral lines. So far there are two standard observing configurations: one recording the $H{\alpha}$ line and the Ca II 8542 line simultaneously, and the other recording the Na I D2 line and Fe I 5435 line simultaneously. We have developed the procedures to produce the standard data for each observing configuration. The procedures include the spatial alignment, the correction of spectral shift of instrumental origin, and the lambdameter measurement of the line wavelength. The standard data include the movie of continuum intensity, the movies of intensity and velocity inferred from a chromospheric spectral line, the movies of intensity and velocity inferred from a photospheric line. The processed standard data will be freely available online (fiss.snu.ac.kr) to be used for research and public outreach. Moreover, the IDL procedures will be provided on request as well so that each researcher can adapt the programs for their own research.

  • PDF

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

Development of Pattern Drafting Method for Hip-hugger Tight Skirt and Round Belt (힙 허거(hip-hugger)형 타이트 스커트 및 라운드 벨트 패턴 제도법 개발)

  • Park, Soon-Jee;Kim, Hye-Jin
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.661-671
    • /
    • 2011
  • This study was designed to produce rounded belt pattern and tight-skirt pattern drafting method using 3D body scan data. Subjects were thirty women in their early twenties. In order to figure out the optimum cutting points, namely, where darts are made, using CAD program, curve ratio inflection points on the horizontal curve of waist, abdomen, and hip to find 1 point in the front, two points in the back part. The average length from center front point to maximum curve ratio was 7.7 cm(46.3%) on the waist curve; 7.9 cm(39.4%) on the abdomen curve. And the average length from center back point to maximum curve ratio point was 6.9 cm(39.0%) for first dart and 11.2 cm(63.3%) for second dart on the waist curve; 8.9 cm(35.8%) for first dart and 15.7 cm(63.3%) for second dart on the hip curve respectively. The cutting lines from were made up by connecting curve inflection points. After divided using cutting lines, each patch was flattened onto the plane and all the technical design factors related with patternmaking were measured, such as dart amount, lifting amount of side waist point, etc. Based on the results of correlation analysis among these factors, regression analysis was done to produce equations to estimate the variables necessary to draw up pattern draft method; F1=F8+1.1, $F4=2.5{\times}F2+0.9$, $F5=0.9{\times}F4+1.0$, $F6=0.3{\times}F4+0.4$, $B1=0.9{\times}B8+2.3$, $B4=2.1{\times}B2+1.3$, $B5=0.9{\times}B4+3.5$, and $B6=0.3{\times}B4+0.4$.

Wafer-Level Fabrication of a Two-Axis Micromirror Driven by the Vertical Comb Drive (웨이퍼 레벨 공정이 가능한 2축 수직 콤 구동 방식 마이크로미러)

  • Kim, Min-Soo;Yoo, Byung-Wook;Jin, Joo-Young;Jeon, Jin-A;Park, Il-Heung;Park, Jae-Hyoung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.148-149
    • /
    • 2007
  • We present the design and fabrication prcoess of a two-axis tilting micromirror device driven by the electrostatic vertical comb actuator. A high aspect-ratio comb actuator is fabricated by multiple DRIE process in order to achieve large scan angle. The proposed fabrication process enables a mirror to be fabricated on the wafer-scale. By bonding a double-side polished (DSP) wafer and a silicon-on-insulator (SOI) wafer together, all actuators on the wafer are completely hidden under the reflectors. Nickel lines are embedded on a Pyrex wafer for the electrical access to numerous electrodes of mirrors. An anodic bonding step is implemented to contact electrical lines with ail electrodes on the wafer at a time. The mechanical angle of a fabricated mirror has been measured to be 1.9 degree and 1.6 degree, respectively, in the two orthogonal axes under driving voltages of 100 V. Also, a $8{\times}8$ array of micromirrors with high fill-factor of 70 % is fabricated by the same fabrication process.

  • PDF

The Effect of miR-361-3p Targeting TRAF6 on Apoptosis of Multiple Myeloma Cells

  • Fan, Zhen;Wu, Zhiwei;Yang, Bo
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.197-206
    • /
    • 2021
  • microRNA-361-3p (miR-361-3p) is involved in the carcinogenesis of oral cancer and pancreatic catheter adenocarcinoma, and has anti-carcinogenic effects on non-small cell lung cancer (NSCLC). However, its effect on multiple myeloma (MM) is less reported. Here, we found that upregulating the expression of miR-361-3p inhibited MM cell viability and promoted MM apoptosis. We measured expressions of tumor necrosis factor receptor-associated factor 6 (TRAF6) and miR-361-3p in MM cells and detected the viability, colony formation rate, and apoptosis of MM cells. In addition, we measured expressions of apoptosis-related genes Bcl-2, Bax, and Cleaved caspase-3 (C caspase-3). The binding site between miR-361-3p and TRAF6 was predicted by TargetScan. Our results showed that miR-361-3p was low expressed in the plasma of MM patients and cell lines, while its overexpression inhibited viability and colony formation of MM cells and increased the cell apoptosis. Furthermore, TRAF6, which was predicted to be a target gene of miR-361-3p, was high-expressed in the plasma of patients and cell lines with MM. Rescue experiments demonstrated that the effect of TRAF6 on MM cells was opposite to that of miR-361-3p. Upregulation of miR-361-3p induced apoptosis and inhibited the proliferation of MM cells through targeting TRAF6, suggesting that miR-361-3p might be a potential target for MM therapy.

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

A High-speed Fuzzy Controller with Integer Operations on GUI Environments (GUI 환경에서의 정수형 연산만을 사용한 고속 퍼지제어기)

  • Kim, Jong-Hyuk;Son, Ki-Sung;Lee, Byung-Kwon;Lee, Sang-Gu
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.4
    • /
    • pp.373-378
    • /
    • 2002
  • In fuzzy inferencing, most of conventional fuzzy controllers have problems of speed down in floating point operations of fuzzy membership functions in (0,1) as compared with integer operations. Therefore, in this paper, we propose a high-speed fuzzy controller with only integer operations. In this, for fast fuzzy computations, we use a scan line conversion algorithm to convert lines of each fuzzy linguistic term to the set of the closest integer pixels. We also implement a GUI (Graphic User Interface) application program for the convenient environments to modify and input fuzzy membership functions.

Integrated GUI Environment of Parallel Fuzzy Inference System for Pattern Classification of Remote Sensing Images

  • Lee, Seong-Hoon;Lee, Sang-Gu;Son, Ki-Sung;Kim, Jong-Hyuk;Lee, Byung-Kwon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.2
    • /
    • pp.133-138
    • /
    • 2002
  • In this paper, we propose an integrated GUI environment of parallel fuzzy inference system fur pattern classification of remote sensing data. In this, as 4 fuzzy variables in condition part and 104 fuzzy rules are used, a real time and parallel approach is required. For frost fuzzy computation, we use the scan line conversion algorithm to convert lines of each fuzzy linguistic term to the closest integer pixels. We design 4 fuzzy processor unit to be operated in parallel by using FPGA. As a GUI environment, PCI transmission, image data pre-processing, integer pixel mapping and fuzzy membership tuning are considered. This system can be used in a pattern classification system requiring a rapid inference time in a real-time.

Image Technique of Surface Defects by Using Photoacoustic Signal Processing (광음향 신호처리를 이용한 표면결함의 영상 기술)

  • Yi, Chong-Ho;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.45-49
    • /
    • 1994
  • In this paper, photoacoustic image processing system was constructed by using 2W CW $CO_{2}$ laser of $10.6{\mu}m$ wavelength and PZT 5A acoustic transducer. Stainless steel of 5mm thickness was used as a sample in experiment. Three line cracks of $50{\mu}m$ in each width and depth were made by using plasma on the surface of the sample. Also, each gap among their lines was $200{\mu}m$ and $300{\mu}m$ in width. In the scan range of $2.2mm\times2mm$ including surface defects, a good image of $50{\mu}m$ resolution had been shown when modulation frequency of CW laser was 100Hz.

  • PDF