• Title/Summary/Keyword: scan pattern

Search Result 395, Processing Time 0.033 seconds

Hip Protector Design Process for the Korean Elderly

  • Jeon, Eun-Jin;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.520-530
    • /
    • 2016
  • This research aims to propose an ergonomic design process for hip protector based on previous studies, existing products, multidisciplinary experts opinion, and wearing test. The elderly are more likely to suffer a hip fracture when they fall due to their physical changes in skeletal form, muscle quantity, bone density, and joint movement. A hip protector is an effective product to prevent hip fractures in the elderly but it also has a problem in that it is uncomfortable. Therefore there is a high chance that it won't be able to prevent hip fractures properly. Since the comfort of a hip protector is one of the most critical elements in preventing a hip fracture, we need to keep improving the hip protector for mobility and usability. Based on the previous studies and limitations of current hip protector products, we need to come up with an optimal design for the Korean elderly. First, knowledge has to be built relating to the ergonomic design of the hip protector considering body shape and size analysis using 3D-scan data, and biomechanical analysis on hip fracture. Second, we need to develop a design process including hip protector pattern design, and wearing evaluation with virtual system. Third, we suggest to reevaluate and verify the design procedure from impact evaluation using testing simulator, virtual evaluation of impact, to wearing comfort and usability evaluation. This design process presented in this study would be expected to contribute to the development of ergonomic hip protector which is suitable for the Korean elderly.

A Case of Miliary Tuberculosis Misdiagnosed as Pneumonia and ARDS Due to the Transient Improvement after Intravenous Injection of Levofloxacin (폐렴, 급성호흡곤란증후군으로 오인되어 Levofloxacin 투여 후 호전되어 진단이 지연된 속립성 결핵 1예)

  • Lee, Go Eun;Cho, Young Jun;Cho, Hyun Min;Son, Ji Woong;Choi, Eu Gene;Na, Moon Jun;Kwon, Sun Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.236-240
    • /
    • 2009
  • Miliary tuberculosis is quite a rare but serious cause of acute respiratory distress syndrome (ARDS). Therefore, the early detection of military tuberculosis as the underlying cause of ARDS is very important for the prognosis and survival of the patient. We report a case of military tuberculosis mimicking ARDS. A female patient was admitted due to repeated fever and dyspnea. The initial chest CT scan showed diffuse ground glass opacity, without a miliary pattern. The case was considered to be ARDS caused by pneumonia. She showed improvement after being treated with levofloxacin. However, she was re-admitted with fever seven days after discharge. The follow up chest CT scan showed micronodules in both lungs. An open lung biopsy confirmed the diagnosis of military tuberculosis.

A Study of Applications of 3D Body Scanning Technology - Focused on Apparel Industry - (3차원 바디 스캐너를 활용한 가상착의에 관한 인식 조사 - 업체 실무자 및 소비자를 대상으로 -)

  • Paek, Kyung-Ja;Lee, Jeong-Ran;Kim, Mi-Sung
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.719-727
    • /
    • 2009
  • The ultimate success of commercial applications of body scan data in the apparel industry will be consumers' substantial applications such as automated custom fit, size prediction, virtual try-on, personal shopper services (Loker, S. et al., 2004). In this study, we surveyed fifty consumers and forty-seven apparel industry workers about their recognition and interest in 3D body scanning and virtual try-on. The results are as follows: 55% of the apparel industry workers has recognized 3D body scanning as a convenient technology, but do not know how to use it. To the questions regarding virtual try-on, 53% of the workers give positive answers. The consumers have a more positive view on virtual try-on than the workers do. The workers predict that the application of 3D body scan technology to the apparel industry could offer customers helpful information in their clothing selection by using virtual images of various size and style, and increase mass production of MTM(Made-To-Measure). The answers from the male consumers in their twenties indicate that virtual try-on is useful by 88% on offline shopping and by 100% on online shopping. 53% of the workers and 68% of the consumers gave answers that just by virtual try-on they could judge the quality of the apparel products and purchase them. Absolutely 3D virtual try-on is an effective tool for online shoppers. 85% of the workers anticipate applications of the 3D body scanning also in 'body measurement', 'custom pattern development' as well as 'virtual try-on' in the near future. With the positive reactions and the stimulating interests in virtual try-on, the conditions of contemporary world encourage more active researches and wide usages of the technology in apparel industry.

Sialography and Salivary Scan Study of Salivary Diseases (타액선 질환의 조영촬영법과 방사성동위원소 스캔법을 이용한 임상적 연구)

  • Park Yun-Kyoung;Lee Sang-Rae;Hwang Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.175-189
    • /
    • 1999
  • The purpose of this study was to established the characteristic radiographic features in salivary gland diseases by means of sialography and scintigraphy. Sialograms and scintigrams with diseases of salivary gland were examined. In this group were 5 salivary stones, 14 sialadenitis, 17 Sjogren's syndromes and 8 benign tumors. The obtained results were as follows; 1. In the configuration of the shape of main duct, those revealed that modified curvilinear and curvilinear types were predominant in Sjogren's syndromes but reverse sigmoid and angular types were in sialolithiasis and sialadenitis combined with sialodochitis. 2. In the configuration of the course of main duct, those revealed that smooth types were predominant in sialadenitis and irregular types were predominant in Sjogren's syndromes and benign tumors and irregular types were seen in all salivary stones and sialadenitis combined with sialodochitis, 3. In the type of intraglandular pattern, those revealed that destructive changes of salivary duct system and parenchyma were severe in sialadenitis and salivary stones and predominantly severe in Sjogren's syndromes. 4. The function of salivary gland was decreased severely in Sjogren's syndrome. and also decrease in salivary stone and sialadenitis. In benign tumor, the uptake of radioisotope was not seen in lesion and the function of salivary gland decreased in its remaining normal parenchyma.

  • PDF

A whole genomic scan to detect selection signatures between Berkshire and Korean native pig breeds

  • Edea, Zewdu;Kim, Kwan-Suk
    • Journal of Animal Science and Technology
    • /
    • v.56 no.7
    • /
    • pp.23.1-23.7
    • /
    • 2014
  • Background: Scanning of the genome for selection signatures between breeds may play important role in understanding the underlie causes for observable phenotypic variations. The discovery of high density single nucleotide polymorphisms (SNPs) provide a useful starting point to perform genome-wide scan in pig populations in order to identify loci/candidate genes underlie phenotypic variation in pig breeds and facilitate genetic improvement programs. However, prior to this study genomic region under selection in commercially selected Berkshire and Korean native pig breeds has never been detected using high density SNP markers. To this end, we have genotyped 45 animals using Porcine SNP60 chip to detect selection signatures in the genome of the two breeds by using the $F_{ST}$ approach. Results: In the comparison of Berkshire and KNP breeds using the FDIST approach, a total of 1108 outlier loci (3.48%) were significantly different from zero at 99% confidence level with 870 of the outlier SNPs displaying high level of genetic differentiation ($F_{ST}{\geq}0.490$). The identified candidate genes were involved in a wide array of biological processes and molecular functions. Results revealed that 19 candidate genes were enriched in phosphate metabolism (GO: 0006796; ADCK1, ACYP1, CAMK2D, CDK13, CDK13, ERN1, GALK2, INPP1; MAK, MAP2K5, MAP3K1, MAPK14, P14KB, PIK3C3, PRKC1, PTPRK, RNASEL, THBS1, BRAF, VRK1). We have identified a set of candidate genes under selection and have known to be involved in growth, size and pork quality (CART, AGL, CF7L2, MAP2K5, DLK1, GLI3, CA3 and MC3R), ear morphology and size (HMGA2 and SOX5) stress response (ATF2, MSRB3, TMTC3 and SCAF8) and immune response (HCST and RYR1). Conclusions: Some of the genes may be used to facilitate genetic improvement programs. Our results also provide insights for better understanding of the process and influence of breed development on the pattern of genetic variations.

Recent Development of Rapid and Automation Technology for Food Microbiological Examination

  • Hiroshi Kurata
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1996.06a
    • /
    • pp.33-33
    • /
    • 1996
  • Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.

Adaptive Thresholding Method Using Zone Searching Based on Representative Points for Improving the Performance of LCD Defect Detection (LCD 결함 검출 성능 개선을 위한 대표점 기반의 영역 탐색을 이용한 적응적 이진화 기법)

  • Kim, Jin-Uk;Ko, Yun-Ho;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.689-699
    • /
    • 2016
  • As the demand for LCD increases, the importance of inspection equipment for improving the efficiency of LCD production is continuously emphasized. The pattern inspection apparatus is one that detects minute defects of pattern quickly using optical equipment such as line scan camera. This pattern inspection apparatus makes a decision on whether a pixel is a defect or not using a single threshold value in order to meet constraint of real time inspection. However, a method that uses an adaptive thresholding scheme with different threshold values according to characteristics of each region in a pattern can greatly improve the performance of defect detection. To apply this adaptive thresholding scheme it has to be known that a certain pixel to be inspected belongs to which region. Therefore, this paper proposes a region matching algorithm that recognizes the region of each pixel to be inspected. The proposed algorithm is based on the pattern matching scheme with the consideration of real time constraint of machine vision and implemented through GPGPU in order to be applied to a practical system. Simulation results show that the proposed method not only satisfies the requirement for processing time of practical system but also improves the performance of defect detection.

The Findings of $^{99m}Tc$-MDP Bone Scan in Primary Malignant Bone Tumors (원발성 악성 골종양의 $^{99m}Tc$-MDP 골스캔 소견)

  • Hyun, In-Young;Lee, Kung-Han;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kang, Heung-Sik;Lee, Sang-Hoon;Lee, Han-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.73-78
    • /
    • 1995
  • [ $^{99m}Tc$ ]-MDP bone scan was performed in 31 patients with primary malignant bone tumors, 22 patients with osteogenic sarcoma, 5 patients with chondrosarcoma and 4 patients with Ewing's sarcoma. The findings were classified by isotope intensity of accumulation in tumor as grade 1 to 3, overall pattern of isotope distribution in tumor as grade 1 to 3, and distortion of bony outline as grade 1 to 3. Histologic classifications were cor related with scan findings in 22 patients with osteogenic sarcoma. The results were as follows 1) In 22 patients with osteogenic sarcoma, markedly increased isotope intensity higher than sacroiliac joint with patchy areas of decreased intensity and severe bony distortion were found in 16 patients. The correlations between histologic classification and scan findings were not discovered. 2) In 5 patients with chondrosarcoma, mildly increased isotope Intensity with patchy areas of increased intensity and mild bony distortion were found in 4 patients.. 3) In 4 patients with Ewing's sarcoma, markedly increased homogenous intensity with moderate bony distortion were found in 3 patients. Conclusively there were common findings in each 3 primary malignant bone tumors and $^{99m}Tc$-MDP bone scan was complemented with radiologic studies in differentiating primary malignant bone tumors.

  • PDF

Evaluation of Space-based Wetland InSAR Observations with ALOS-2 ScanSAR Mode (습지대 변화 관측을 위한 ALOS-2 광대역 모드 적용 연구)

  • Hong, Sang-Hoon;Wdowinski, Shimon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.447-460
    • /
    • 2022
  • It is well known that satellite synthetic aperture radar interferometry (InSAR) has been widely used for the observation of surface displacement owing to earthquakes, volcanoes, and subsidence very precisely. In wetlands where vegetation exists on the surface of the water, it is possible to create a water level change map with high spatial resolution over a wide area using the InSAR technique. Currently, a number of imaging radar satellites are in operation, and most of them support a ScanSAR mode observation to gather information over a large area at once. The Cienaga Grande de Santa Marta (CGSM) wetland, located in northern Colombia, is a vast wetland developed along the Caribbean coast. The CGSM wetlands face serious environmental threats from human activities such as reclamation for agricultural uses and residential purposes as well as natural causes such as sea level rise owing to climate change. Various restoration and protection plans have been conducted to conserve these invaluable environments in recognition of the ecological importance of the CGSM wetlands. Monitoring of water level changes in wetland is very important resources to understand the hydrologic characteristics and the in-situ water level gauge stations are usually utilized to measure the water level. Although it can provide very good temporal resolution of water level information, it is limited to fully understand flow pattern owing to its very coarse spatial resolution. In this study, we evaluate the L-band ALOS-2 PALSAR-2 ScanSAR mode to observe the water level change over the wide wetland area using the radar interferometric technique. In order to assess the quality of the interferometric product in the aspect of spatial resolution and coherence, we also utilized ALOS-2 PALSAR-2 stripmap high-resolution mode observations.

Radiologic Evaluation of Intraabdomenal Masses in Childhood (소아복부 종괴의 방사선학적 고찰)

  • Kwon, Hyuk-Po;Byun, Woo-Mok;Hwang, Mi-Soo;Kim, Sun-Yang;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1988
  • The abdominal tumors in children are different from those of adult. These tumors are the third most common one, preceded by leukemia and brain tumors, in children under 15 years. X-ray examination is the most important method among diagnostic approaches. The role of diagnostic imaging is to identify the precise anatomic location and extent of pathologic process with the minimal number of imaging procedures. 23 cases of abdominal tumors were reviewed in respect of age incidence, site of origin, radiologic findings. The results are briefly summarized as follows : 1. Neuroblastoma was the most common(6 cases) and wi1m's tumor(5 cases), choledocal cyst(4 cases), ovarian mass(3 cases), hydronephrosis(2 cases), were descending order in frequency. 2. The most common site was retroperitoneum(60%). Kidney was the single most common site of origin. 3. Radiologic findings. The most common findings of plain radiography was ill defined soft tissue mass and this method was helpful in the presence of calcification especially in neuroblastoma. Ultrasonographic pattern was anechoic(cystic), echoic or mixed pattern, but this method provide less precise anatomical details, nevertheless ultrasonography wes paticullary useful imaging modality for the pediatric abdominal tumors. IVP findings were renal displacement, caliceopelvic system distortion or nonvisualization of kidney, these information was helpful in determining the location of tumors. CT scan showed homogenous or inhomogenous, cystic or solid, mass with their anatomic location. 4. Ultrasonography was the most widely used specific diagnostic method, but had limited value in detecting the anatomic location of tumors. CT scan was superior to ultrasound for determining the extent of tumors.

  • PDF