Evaluating the accuracy of mass scaling method in non-linear quasi-static finite element analysis of RC structures

  • A. Yeganeh-Salman;M. Lezgy-Nazargah
    • Structural Engineering and Mechanics
    • /
    • 제85권4호
    • /
    • pp.485-500
    • /
    • 2023
  • The non-linear static analysis of reinforced concrete (RC) structures using the three-dimensional (3D) finite element method is a time-consuming and challenging task. Moreover, this type of analysis encounters numerical problems such as the lack of convergence of results in the stages of growth and propagation of cracks in the structure. The time integration analysis along with the mass scaling (MS) technique is usually used to overcome these limitations. Despite the use of this method in the 3D finite element analysis of RC structures, a comprehensive study has not been conducted so far to assess the effects of the MS method on the accuracy of results. This study aims to evaluate the accuracy of the MS method in the non-linear quasi-static finite element analysis of RC structures. To this aim, different types of RC structures were simulated using the finite element approach based on the implicit time integration method and the mass scaling technique. The influences of effective parameters of the MS method (i.e., the allowable values of increase in the mass of the RC structure, the relationship between the duration of the applied load and fundamental vibration period of the RC structure, and the pattern of applied loads) on the accuracy of the simulated results were investigated. The accuracy of numerical simulation results has been evaluated through comparison with existing experimental data. The results of this study show that the achievement of accurate structural responses in the implicit time integration analyses using the MS method involves the appropriate selection of the effective parameters of the MS method.

Recent Development of Linear Scaling Quantum Theories in GAMESS

  • Choi, Cheol-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권6호
    • /
    • pp.733-738
    • /
    • 2003
  • Linear scaling quantum theories are reviewed especially focusing on the method adopted in GAMESS. The three key translation equations of the fast multipole method (FMM) are deduced from the general polypolar expansions given earlier by Steinborn and Ruedenberg. Simplifications are introduced for the rotation-based FMM that lead to a very compact FMM formalism. The OPS (optimum parameter searching) procedure, a stable and efficient way of obtaining the optimum set of FMM parameters, is established with complete control over the tolerable error ε. In addition, a new parallel FMM algorithm, requiring virtually no inter-node communication, is suggested which is suitable for the parallel construction of Fock matrices in electronic structure calculations.

아트리움 공간에서의 화재성상에 관한 축소모델 실험연구 (The Experimental Study of Fire Properties in Reduced-scale Atrium Space)

  • 류승관;김충익;유홍선
    • 한국화재소방학회논문지
    • /
    • 제13권4호
    • /
    • pp.30-37
    • /
    • 1999
  • 본 연구에서는 아트리움 공간에서의 화재성상을 파악하기 위해 실물 실현의 대안으로서 축소 모형 실험을 수행하였다. 연속방정식, 운동량 보존 방정식, 에너지 보존 방정식과 같은 지배 방정식의 차원해석으로부터 추론된 $\pi$변수로부터 축소법칙을 얻었다. 이 축소법칙에 따라 일본의 시반스 아트리움을 1/50로 축소한 모형에서 실험을 수행하였다. 여기서 얻어진결과를 실물 실험 결과와 비교하였다. 더 나아가 이러한 결과들은 레이저 관광을 이용한 가시화 시스템에 의해 가시화 되어졌다.

  • PDF

SOAP를 이용한 원격 퍼지 논리 제어시스템 (Remote Fuzzy Logic Control System using SOAP)

  • 이경웅;최한수
    • 제어로봇시스템학회논문지
    • /
    • 제13권4호
    • /
    • pp.329-334
    • /
    • 2007
  • This paper deals with self-tuning of fuzzy control systems. The fuzzy logic controller(FLC) has parameters that an: input and output scaling factors to effect control output. Tuning method is proposed for the scaling factor. In this paper. it is studied to control and to monitor the remote system statues using SOAP for communicate between the server part and the client part. The remote control system is controlled by using a web browser or a application program. The server part is waiting for the request of client part that uses internet network for communication each other and then the request is reached. the server part saves client data to the database and send a command set to the client part and then the client part sends command to controller in a cool chamber. The administrator can control and monitor the remote system just using a web browser. The effects of membership functions, defuzzification methods and scaling factors are investigated in the FLC system.

위상 조절 인자를 고려한 IMC-PID 제어기의 설계 (The Design of IMC-PID Controller Considering a Phase Scaling Factor)

  • 김창현;임동균
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1618-1623
    • /
    • 2008
  • In this paper, a new design method for IMC-PID that adds a phase scaling factor of system identifications to the standard IMC-PID controller as a control parameter is proposed. Based on analytically derived frequency properties such as gain and phase margins, this tuning rule is an optimal control method determining the optimum values of controlling factors to minimize the cost function, integral error criterion of the step response in time domain, in the constraints of design parameters to guarantee qualified frequency design specifications. The proposed controller improves existing single-parameter design methods of IMC-PID in the inflexibility problem to be able to consider various design specifications. Its effectiveness is examined by a simulation example, where a comparison of the performances obtained with the proposed tuning rule and with other common tuning rules is shown.

Optimum amount of additive mass in scaling of operational mode shapes

  • Khatibi, M.M.;Ashory, M.R.;Albooyeh, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.733-750
    • /
    • 2011
  • Recently, identification of modal parameters using the response only data has attracted considerable attention particularly where the classic modal testing methods is difficult to conduct. One drawback of the response only data, also known as Operational Modal Analysis (OMA), is that only the unscaled mode shapes can be obtained which restricts the applications of OMA. The Mass change method is a usual way to scale the operational mode shapes. In this article a new method is proposed to optimize the additive mass for scaling of the unscaled mode shapes from OMA for which a priori knowledge of the Finite Element model of structure is required. It is shown that the total error of the scaled mode shapes is minimized using the proposed method. The method is validated using a numerical case study of a beam. Moreover, the experimental results of a clamped-clamped beam demonstrate the applicability of the method.

PRACTICAL FHE PARAMETERS AGAINST LATTICE ATTACKS

  • Cheon, Jung Hee;Son, Yongha;Yhee, Donggeon
    • 대한수학회지
    • /
    • 제59권1호
    • /
    • pp.35-51
    • /
    • 2022
  • We give secure parameter suggestions to use sparse secret vectors in LWE based encryption schemes. This should replace existing security parameters, because homomorphic encryption (HE) schemes use quite different variables from the existing parameters. In particular, HE schemes using sparse secrets should be supported by experimental analysis, here we summarize existing attacks to be considered and security levels for each attacks. Based on the analysis and experiments, we compute optimal scaling factors for CKKS.

동축 수소 확산화염에서의 NOx 생성 분석 (Analysis of NOx Emissions in Thrbulent Nonpremixed Hydrogen-Air Jet Flames with Coaxial Air)

  • 박양호;김성룡;문희장;윤영빈;정인석
    • 한국연소학회지
    • /
    • 제5권1호
    • /
    • pp.19-30
    • /
    • 2000
  • The characteristics of NOx emissions in pure hydrogen nonpremixed flames with coaxial air are analyzed numerically for the three model cases of coaxial air flames classified by varying coaxial air velocity and/or fuel velocity. In coaxial air flames, the flame length is reduced by coaxial air and can be represented as a function of the ratio of coaxial air to fuel velocity. Coaxial air decreases flame reaction zone, resulting in reducing flame residence time significantly. Finally, the large reduction of EINOx is achieved by the decrease of the flame residence time. It is found that because coaxial air can break down the flame self-similarity law, appropriate scaling parameters, which are different from those in the simple jet flames, are recommended. In coaxial air flames, the flame residence time based on the flame volume produces better results than that based on a cube of the flame length. And some portion of deviations from the 1/2 scaling law by coaxial air may be due to the violation of the linear relationship between the flame volume and the flame reaction zone.

  • PDF

수소 난류확산화염에서 NOx 생성특성에 대한 화염열복사의 영향 (The Effect of Flame Radiation on NOx Emission Characteristics in Hydrogen Thrbulent Diffusion Flames)

  • 김승한;김문기;윤영빈
    • 한국연소학회지
    • /
    • 제5권2호
    • /
    • pp.51-62
    • /
    • 2000
  • The relationship among the flame radiation, NOx emissions, residence time, and global strain rate are examined for turbulent non-premixed jet flames with wide variations in coaxial air conditions. Measurements of NOx emission, flame geometry and flame radiation were made to explain the NOx emission scaling based on global parameters such as flame residence time, global strain rate, and radiant fraction. The overall 1/2-power scaling is observed in coaxial air flames, irrespective of coaxial air conditions, but the degree of deviation from the 1/2-slope curve in each case differs from one another. From the comparison between the results of pure hydrogen flames and those of helium diluted hydrogen flames, it is observed that flame radiation plays a significant role in pure hydrogen flames with coaxial air and the deviation from 1/2-power scaling may be explained in two reasons: the difference in the flame radiation and the difference in jet similarity in coaxial air flames. From the radiation measurements, more detailed explanations on these deviations were suggested.

  • PDF

스케일링-웨이블렛 신경회로망 구조 (The Structure of Scaling-Wavelet Neural Network)

  • 김성주;서재용;김용택;조현찬;전홍태
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 춘계학술대회 학술발표 논문집
    • /
    • pp.65-68
    • /
    • 2001
  • RBFN has some problem that because the basis function isnt orthogonal to each others the number of used basis function goes to big. In this reason, the Wavelet Neural Network which uses the orthogonal basis function in the hidden node appears. In this paper, we propose the composition method of the actual function in hidden layer with the scaling function which can represent the region by which the several wavelet can be represented. In this method, we can decrease the size of the network with the pure several wavelet function. In addition to, when we determine the parameters of the scaling function we can process rough approximation and then the network becomes more stable. The other wavelets can be determined by the global solutions which is suitable for the suggested problem using the genetic algorithm and also, we use the back-propagation algorithm in the learning of the weights. In this step, we approximate the target function with fine tuning level. The complex neural network suggested in this paper is a new structure and important simultaneously in the point of handling the determination problem in the wavelet initialization.

  • PDF