• Title/Summary/Keyword: scaling effects

Search Result 348, Processing Time 0.029 seconds

Efficacy of nonsurgical periodontal therapy on glycaemic control in type II diabetic patients: a randomized controlled clinical trial

  • Telgi, Ravishankar Lingesha;Tandon, Vaibhav;Tangade, Pradeep Shankar;Tirth, Amit;Kumar, Sumit;Yadav, Vipul
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.177-182
    • /
    • 2013
  • Purpose: Diabetes and periodontal disease are two common diseases with high prevalence rates. Recent evidence has shown a bidirectional relationship between diabetes and periodontitis. The aim of this study was to investigate the effects of nonsurgical periodontal therapy on glycemic control in type 2 diabetes mellitus patients. Methods: Sixty subjects aged 35-45 years with blood sugar controlled by oral hypoglycaemic agents were randomly divided equally among 3 groups: group A (scaling, mouthwash, and brushing), group B (mouthwash and brushing), and group C (brushing only). Glycated haemoglobin (HbA1c), fasting blood sugar (FBS), probing pocket depth (PPD), gingival index (GI), plaque index (PI), and the relevant drug history were recorded at baseline and after 3 months of intervention. Comparison of the mean difference among the variables was performed by parametric and nonparametric tests, which were further evaluated using multiple regression analysis. Results: The mean differences between the PPD, FBS, HbA1c, GI, and PI in groups A and B were found to be statistically significant (P<0.001). Multiple regression analysis in group A showed that out of all the independent variables, GI and frequency of drug administration independently (b=0.3761 and b=0.598) showed a significantly greater impact on HbA1c ($R^2$=0.832, P<0.05). Conclusions: Nonsurgical periodontal therapy can effectively decrease HbA1c levels in type 2 diabetes mellitus patients on medication.

Comparative Study on Subgingival Irrigation Using Some Oral Mouth Rinses on Early Healing Process of Periodontal Inflammation (수 종의 구강세정제에 의한 치은연하 세정이 치주염 초기치유에 미치는 영향에 관한 비교 연구)

  • Yun, Gi-Yon;Kim, Kang-Ju;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.465-475
    • /
    • 1998
  • The purpose of this study was to investigate the comparative effects of subgingival irrigation using some oral mouth rinses on early healing process of periodontal inflammation. The study population consisted of 13 patients with periodontal inflammation and distributed into 4 groups. Oral hygiene instruction, delicate scaling and root planing were done and then irrigated per 3 days during 2 weeks in situ with 1 of 4 solutions ; normal saline, C31G, Benzotonium chloride and tetracycline. Examination regarding probing pocket depth, plaque index, sulcular bleeding index, gingival index, gingival recession and leukocytes differential count was performed. Evaluation was made at the baseline and 2 weeks after non-surgical periodontal therapy. The results were as follows : 1. Clinical indices including probing pocket depth, plaque index, sulcular bleeding index, gingival index and gingival recession were significantly improved from baseline to 2 weeks. But there was no significant differences among 4 groups. 2. PMNs percent on leukocytes differential count was significantly decreased from baseline to 2 weeks on all groups. Those of tetracycline and C31G were significantly decreased than those of normal saline group. These results suggest that clinical indices were not different, but the decrease of inflammation were significantly different among some mouth rinses.

  • PDF

Compressible Simulation of Rotor-Stator Interaction in Pump-Turbines

  • Yan, Jianping;Koutnik, Jiri;Seidel, Ulrich;Hubner, Bjorn
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.315-323
    • /
    • 2010
  • This work investigates the influence of water compressibility on pressure pulsations induced by rotor-stator interaction (RSI) in hydraulic machinery, using the commercial CFD solver ANSYS-CFX. A pipe flow example with harmonic velocity excitation at the inlet plane is simulated using different grid densities and time step sizes. Results are compared with a validated code for hydraulic networks (SIMSEN). Subsequently, the solution procedure is applied to a simplified 2.5-dimensional pump-turbine configuration in prototype with different speeds of sound as well as in model scale with an adapted speed of sound. Pressure fluctuations are compared with numerical and experimental data based on prototype scale. The good agreement indicates that the scaling of acoustic effects with an adapted speed of sound works well. With respect to pressure fluctuation amplitudes along the centerline of runner channels, incompressible solutions exhibit a linear decrease while compressible solutions exhibit sinusoidal distributions with maximum values at half the channel length, coinciding with analytical solutions of one-dimensional acoustics. Furthermore, in compressible simulation the amplification of pressure fluctuations is observed from the inlet of stay vane channels to the spiral case wall. Finally, the procedure is applied to a three-dimensional pump configuration in model scale with adapted speed of sound. Normalized Pressure fluctuations are compared with results from prototype measurements. Compared to incompressible computations, compressible simulations provide similar pressure fluctuations in vaneless space, but pressure fluctuations in spiral case and penstock may be much higher.

A study on the practice application of oral hygiene auxiliary supplies and oral health status ofpatients in 'S' university dental clinic (치위생과 실습실 내원환자의 구강위생보조용품 사용유무와 구강건강상태와의 관계)

  • Nam, Sang-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.373-381
    • /
    • 2011
  • Objectives : The purpose of this study was to investigate the relationship among the practice application of oral hygiene auxiliary supplies, oral health state of patients in S university dental clinic. Methods : The subject in this were 261 patients who got a scaling at the oral hygiene practice lab in the department of dental hygiene in S university dental clinic from April 1 to May 31, 2010. For the data analysis, an SPSS WIN 11.5 program was used and its signification level was 0.05. Results : 1. For the oral health state according to sex distinction, it showed the men's 0.78 MT index was higher than women's 0.48 MT index and statistically significant difference. 2. For FT index, women(4.72) was higher than men(3.50) and it showed statistically significant difference(p<0.05). 3. For the oral health state according to sex distinction, Why not use oral hygiene auxiliary supplies showed statistically significant difference(p<0.05). 4. For the practice application of oral hygiene auxiliary supplies according to age distinction, 18.5% more than 30 years replied as I use interdental brush and it showed statistically significant difference. 18.5% more than 30 years replied as I use powered brush and it showed statistically significant difference(p<0.05). 5. For the oral health state according to the practice application of oral hygiene auxiliary supplies distinction, there were significant difference that dental floss, interdental brush, mouth rinse product, Why not use oral hygiene auxiliary supplies(p<0.05). Conclusions : The findings of this study were lower than the utilization of oral hygiene auxiliary supplies. Therefore, to increase the use of oral hygiene auxiliary supplies to patients of the appropriate selection and correct usage of oral hygiene auxiliary supplies and the resulting effects have sufficient training to practice more efficiently should be.

The study of plasma source ion implantation process for ultra shallow junctions (Ulra shallow Junctions을 위한 플라즈마 이온주입 공정 연구)

  • Lee, S.W.;Jeong, J.Y.;Park, C.S.;Hwang, I.W.;Kim, J.H.;Ji, J.Y.;Choi, J.Y.;Lee, Y.J.;Han, S.H.;Kim, K.M.;Lee, W.J.;Rha, S.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.111-111
    • /
    • 2007
  • Further scaling the semiconductor devices down to low dozens of nanometer needs the extremely shallow depth in junction and the intentional counter-doping in the silicon gate. Conventional ion beam ion implantation has some disadvantages and limitations for the future applications. In order to solve them, therefore, plasma source ion implantation technique has been considered as a promising new method for the high throughputs at low energy and the fabrication of the ultra-shallow junctions. In this paper, we study about the effects of DC bias and base pressure as a process parameter. The diluted mixture gas (5% $PH_3/H_2$) was used as a precursor source and chamber is used for vacuum pressure conditions. After ion doping into the Si wafer(100), the samples were annealed via rapid thermal annealing, of which annealed temperature ranges above the $950^{\circ}C$. The junction depth, calculated at dose level of $1{\times}10^{18}/cm^3$, was measured by secondary ion mass spectroscopy(SIMS) and sheet resistance by contact and non-contact mode. Surface morphology of samples was analyzed by scanning electron microscopy. As a result, we could accomplish the process conditions better than in advance.

  • PDF

DC Characteristic of Silicon-on-Insulator n-MOSFET with SiGe/Si Heterostructure Channel (SiGe/Si 이종접합구조의 채널을 이용한 SOI n-MOSFET의 DC 특성)

  • Choi, A-Ram;Choi, Sang-Sik;Yang, Hyun-Duk;Kim, Sang-Hoon;Lee, Sang-Heung;Shim, Kyu-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.99-100
    • /
    • 2006
  • Silicon-on-insulator(SOI) MOSFET with SiGe/Si heterostructure channel is an attractive device due to its potent use for relaxing several limits of CMOS scaling, as well as because of high electron and hole mobility and low power dissipation operation and compatibility with Si CMOS standard processing. SOI technology is known as a possible solution for the problems of premature drain breakdown, hot carrier effects, and threshold voltage roll-off issues in sub-deca nano-scale devices. For the forthcoming generations, the combination of SiGe heterostructures and SOI can be the optimum structure, so that we have developed SOI n-MOSFETs with SiGe/Si heterostructure channel grown by reduced pressure chemical vapor deposition. The SOI n-MOSFETs with a SiGe/Si heterostructure are presented and their DC characteristics are discussed in terms of device structure and fabrication technology.

  • PDF

Effects of EAI and VAS on perceptual judgement and confidence rating by listeners for voice disorders (청지각적 평가 방식에 따른 음성장애 심한 정도 판단과 자가 신뢰도에 대한 차이)

  • Lee, Ok-Bun;Kim, Sun-Hee;Jeong, Hanjin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3046-3050
    • /
    • 2014
  • The purpose of the present study was to evaluate the effect of 7-point interval scale(EAI) and visual analogue scale(VAS) on perceptual judgement and the reliability of severity on voice problems by dysphonic speakers. 30 undergraduate students studying communication disorder were enrolled in the perceptual evaluation. Those listeners judged overall voice severity within the anchored(condition 1) and non-anchored scales(condition 2) for vowel prolongation and reading tasks by 25 speakers with voice disorder. The results of this study showed that the scores by VAS was significantly higher than EAI in both condition 1 and condition 2 for vowel prolongation and reading task. However, the scores by EAI method was higher than by VAS method on voice severity of vowel prolongation (condition 1) and reading task(condition 2). These results suggest auditory-perceptual scaling procedures must be more studied in the aspects of clinical application of voice disorder.

Effects of diet and roughage quality, and period of the day on diurnal feeding behaviour patterns of sheep and goats under subtropical conditions

  • Moyo, Mehluli;Adebayo, Rasheed Adekunle;Nsahlai, Ignatius Verla
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.675-690
    • /
    • 2019
  • Objective: This study investigated the effect of diet and roughage quality (RQ) on dry matter intake, duration and number of daytime and night-time eating bouts, idling sessions and ruminating activities in small ruminants. Methods: In Exp 1 and 2, RQ was improved by urea treatment of veld hay, while diet quality was improved by supplementing with Lucerne hay (Exp 3), sunflower meal and lespedeza (Exp 4), fish meal (Exp 5a), and sunflower meal (Exp 5b). In all experiments goats and sheep were blocked by weight and randomly allocated to experimental diets. Day-time (06:00 to 18:00 h) and night time (18:00 to 06:00 h) feeding behaviour activities were recorded. Results: RQ affected rumination index in Exp 1, but not in Exp 2, 3, and 5. Time spent eating and ruminating was affected by RQ (Exp 1, 3, and 4), period of day (all experiments) and their interaction (Exp 1). Intake rates (g/bout and g/min) were similar across diets. Period of day affected the duration of rumination sessions (Exp 1, 2, and 3); diet or RQ affected the duration of eating bouts (Exp 3) and rumination sessions (Exp 1 and 2). RQ had a significant effect on the duration of eating sessions in Exp 3 only, whilst period of day affected this same behaviour in Exp 2 and 3. Generally, goats and sheep fed on roughage alone ruminate at night and eat more during the day but those fed a roughage and supplemented with Lucerne hay spent more time ruminating than eating. Time spent eating and ruminating had positive correlations to crude protein and feed intake. Intake rates had strong positive correlations to intake. Conclusion: Chewing time, number of eating and ruminating sessions, and duration of eating bouts are physiologically controlled in small ruminants, though chewing time requires isometric scaling during modelling of intake.

Blood clot stabilization after different mechanical and chemical root treatments: a morphological evaluation using scanning electron microscopy

  • Stefanini, Martina;Ceraolo, Edoardo;Mazzitelli, Claudia;Maravic, Tatjana;Sangiorgi, Matteo;Zucchelli, Giovanni;Breschi, Lorenzo;Mazzoni, Annalisa
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.1
    • /
    • pp.54-64
    • /
    • 2022
  • Purpose: This in vitro study was conducted to evaluate the effects of different debridement techniques and conditioning procedures on root surface morphology and blood clot stabilization. Methods: Two debridement techniques (curette [CU] vs. high-speed ultrasound [US]) and 2 conditioning procedures (ethylenediaminetetraacetic acid [EDTA] and phosphoric acid [PA]) were used for the study. Seven experimental groups were tested on root surfaces: 1) no treatment (C); 2) CU; 3) US; 4) CU+EDTA; 5) US+EDTA; 6) CU+PA; and 7) US+PA. Three specimens per group were observed under scanning electron microscopy (SEM) for surface characterization. Additional root slices received a blood drop, and clot formation was graded according to the blood element adhesion index by a single operator. Data were statistically analyzed, using a threshold of P<0.05 for statistical significance. Results: The C group displayed the most irregular surface among the tested groups with the complete absence of blood traces. The highest frequency of blood component adhesion was shown in the CU+EDTA group (P<0.05), while no differences were detected between the CU, US+EDTA, and CU+PA groups (P<0.05), which performed better than the US and US+PA groups (P<0.05). Conclusions: In this SEM analysis, EDTA and conventional manual scaling were the most efficient procedures for enhancing smear layer removal, collagen fiber exposure, and clot stabilization on the root surface. This technique is imperative in periodontal healing and regenerative procedures.

Reynolds number and scale effects on aerodynamic properties of streamlined bridge decks

  • Ma, Tingting;Feng, Chaotian
    • Wind and Structures
    • /
    • v.34 no.4
    • /
    • pp.355-369
    • /
    • 2022
  • Section model test, as the most commonly used method to evaluate the aerostatic and aeroelastic performances of long-span bridges, may be carried out under different conditions of incoming wind speed, geometric scale and wind tunnel facilities, which may lead to potential Reynolds number (Re) effect, model scaling effect and wind tunnel scale effect, respectively. The Re effect and scale effect on aerostatic force coefficients and aeroelastic characteristics of streamlined bridge decks were investigated via 1:100 and 1:60 scale section model tests. The influence of auxiliary facilities was further investigated by comparative tests between a bare deck section and the deck section with auxiliary facilities. The force measurement results over a Re region from about 1×105 to 4×105 indicate that the drag coefficients of both deck sections show obvious Re effect, while the pitching moment coefficients have weak Re dependence. The lift coefficients of the smaller scale models have more significant Re effect. Comparative tests of different scale models under the same Re number indicate that the static force coefficients have obvious scale effect, which is even more prominent than the Re effect. Additionally, the scale effect induced by lower model length to wind tunnel height ratio may produce static force coefficients with smaller absolute values, which may be less conservative for structural design. The results with respect to flutter stability indicate that the aerodynamic-damping-related flutter derivatives 𝘈*2 and 𝐴*1𝐻*3 have opposite scale effect, which makes the overall scale effect on critical flutter wind speed greatly weakened. The most significant scale effect on critical flutter wind speed occurs at +3° wind angle of attack, which makes the small-scale section models give conservative predictions.