정성적/정성적 디자인 가치의 누적평가방법에 관한 기초 연구 (A Study on the Accumulative Evaluation of Qualified Quantified Values in Industrial Design)

  • 박대순;우흥룡
    • 디자인학연구
    • /
    • 제3권1호
    • /
    • pp.17-33
    • /
    • 1990
  • Evaluation plays an essential role in design activity. Many theorist have agreed that designing involves problem solving or decision making. In evaluation, designers attempt to determine the value of a particular proposal arrived at by synthesis. And the results of designing, the product, is evaluated twice, objectively and subjectively.Alternatives in $$\mu$ti-objective decision problems generally possess numerous attributes by which they can be described and compared. The evaluation factors include all attributes that have levels specified by quantitative and qualitative objectives. However since qualitiative factors are difficult to quantify as $$\mu$eral estmates, these factors have tended to be ignored without regard for their importance to human content. Therefore we need some study that convert qualitative attributes into quantitative scale values. Following to Thurstone' s Psychological scaling methods (The method of successive intervals), attribute values of TV set are assigned by rating scale methods. The method of successive intervals, like the method of equal-appearing intervals, requires but a single judgement from each subject for each statement to be scaled. It is, therefore, a convinient method to use when the number of to be scaled is large. We make the assumtion that those cu$$\mu$ative proportion distributions are normal for each statement when they are projected on the unknown psychological continuum. In this study, we have determined the scale values of 42 statements of TV set by the method of successive intervals. Then we can apply a test of internal consistency similar to that used with the method of paired comparisons. We have as our absolute average deviation, -1.748/252= -0.0069. We have reason to believe that our scale values are consistent with the empirical data, because these discrepanicies are very small.

  • PDF

탄소섬유 앵커 X-브레이싱으로 보강된 철근콘크리트 기둥의 구조거동 및 내진보강 효과 (Retrofitting Effects and Structural Behavior of RC Columns Strengthened with X-Bracing Using Carbon Fiber Anchor)

  • 심종성;이강석;권혁우;김현중
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.323-331
    • /
    • 2012
  • 이 논문에서는 콘크리트 기둥에 새로운 보강방법을 제시하여 반복하중에 대한 구조적인 성능시험을 하였다. 두 개의 콘크리트 기둥에 고성능 탄소섬유 다발을 이용하여 X자 형태의 보강을 실시하고, 기둥의 내부에 X-브레이싱을 고정하기 위해 기둥 단면을 천공하여 탄소섬유 다발을 기둥에 삽입한 후 탄소섬유로 단부를 감싸주는 새로운 보강방법인 탄소섬유 앵커 X-브레이싱 보강공법을 이용해 콘크리트 기둥의 구조성능과 보강효과를 시험을 통하여 규명하였다. 이를 위해 탄소섬유로 보강된 휨 파괴형 실험체 기둥과 전단 파괴형 실험체 기둥을 축소모형으로 각각 제작하였다. 휨과 전단저항 기둥에 대해 X-브레이스 보강 유, 무 실험체에 반복하중시험을 통해 기둥의 연성과 강도 보강효과를 확인하였다.

텔레뷰어 암석강도 산출 및 그의 응용성 (Televiewer Rock Strength as an Approach to Estimate the Strength of in situ Rocks)

  • 김중열;김유성;현혜자
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.237-244
    • /
    • 2002
  • Televiewer is a logging tool capable of scanning the borehole wall. The tool uses a rotating acoustic beam generator that acts as both a transmitter and receiver. The beams are sent toward the wall. The amplitude of a returning signal from the wall has nearly a linear relationship with the reflection coefficient R of the borehole wall, when the wall is smooth. As R depends only on rock impedance for fixed water impedance, the amplitude is directly associated with mass density and seismic velocity of rock. Meanwhile, the amplitude can be further reduced by wall roughness that may be caused by drilling procedures, differences in rock hardness, because the rough surface can easily scatter the acoustic energy and sometimes the hole becomes elongated in all directions according to the degree of weathering. In this sense, the amplitude is related to the hardness of rocks. For convenience of analysis, the measured amplitude image(2-D data(azimuth ${\times}$ depth)) is converted, with an appropriate algorithm, to the 1-D data(depth), where the amplitude image values along a predetermined fracture signature(sinusoid) are summed up and averaged. The resulting values are subsequently scaled simply by a scalar factor that is possibly consistent with a known strength. This scaled Televiewer reflectivity is named, as a matter of convenience,“Televiewer rock strength”. This paper shows, based on abundant representative case studies from about 8 years of Televiewer surveys, that Televiewer rock strength might be regarded, on a continuous basis with depth, as a quitely robust indicator of rock classification and in most cases as an approximate uniaxial strength that is comparable to the rebound value from Schmidt hammer test.

  • PDF

야간 영상 감시를 위한 GMM기반의 배경 차분 (Background Subtraction based on GMM for Night-time Video Surveillance)

  • 여정연;이귀상
    • 스마트미디어저널
    • /
    • 제4권3호
    • /
    • pp.50-55
    • /
    • 2015
  • 본 논문에서는 야간 영상 감시(night-time video surveillance)에 특화된 GMM(Gausssian mixture model)기반의 배경 모델링(background modeling)을 이용한 배경 차분(background subtraction)방법을 제안한다. 야간 영상에서는 낮 영상에 비해 배경과 객체의 구분이 뚜렷하지 않아 매우 흡사한 픽셀 값들을 이용하여 배경을 분리해야 한다. 이러한 문제점을 해결하기 위해 전처리 단계에서 조정된 범위의 히스토그램 스트레칭을 이용하여 입력 픽셀 값을 배경 모델링에 이로운 픽셀 값으로 변경해준다. 조정된 픽셀 값을 이용하여 가장 이상적인 배경을 찾기 위해 픽셀 단위로 GMM기반의 배경 모델링 방법을 적용한다. GMM을 기반으로 한 배경모델링 방법에서는 새로운 픽셀 값이 입력되었을 때 어떤 가우시안에도 속하지 않는다면 가장 낮은 가중치를 가진 가우시안 분포를 제거함으로써 이전의 축적된 배경의 정보를 무시하는 결과를 낳게 된다. 따라서 본 논문에서는 낮은 가중치의 가우시안을 제거하는 대신 기존 가우시안의 평균과 입력된 픽셀 값의 차를 이용하여 새로운 평균에 적용함으로써 기존의 쌓여진 정보를 고려한다. 실험결과 제안된 배경 모델링 방법이 기존 방법의 이점을 유지하면서 야간 영상 감지에 특화된 배경 차분 결과를 보였다.

Use of large-scale shake table tests to assess the seismic response of a tunnel embedded in compacted sand

  • Zhou, Hao;Qin, Xiaoyang;Wang, Xinghua;Liang, Yan
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.655-665
    • /
    • 2018
  • Shield tunnels are widely used throughout the world. However, their seismic performance has not been well studied. This paper focuses on the seismic response of a large scale model tunnel in compacted sand. A 9.3 m long, 3.7 m wide and 2.5 m high rigid box was filled with sand so as to simulate the sandy soil surrounding the tunnel. The setup was excited on a large-scale shake table. The model tunnel used was a 1:8 scaled model with a cross-sectional diameter of 900 mm. The effective shock absorbing layer (SAL) on the seismic response of the model tunnel was also investigated. The thickness of the tunnel lining is 60 mm. The earthquake motion recorded from the Kobe earthquake waves was used. The ground motions were scaled to have the same peak accelerations. A total of three peak accelerations were considered (i.e., 0.1 g, 0.2 g and 0.4 g). During the tests, the strain, acceleration and soil pressure on the surface of the tunnel were measured. In order to investigate the effect of shock absorbing layer on the dynamic response of the sand- tunnel system, two tunnel models were set up, one with and one without the shock absorbing layer of foam board were used. The results shows the longitudinal direction acceleration of the model tunnel with a shock absorbing layer were lower than those of model tunnel without the shock absorbing layer, Which indicates that the shock absorbing layer has a beneficial effect on the acceleration reduction. In addition, the shock absorbing layer has influence on the hoop strain and earth pressure of the model tunnel, this the effect of shock absorbing layer to the model tunnel will be discussed in the paper.

Cyclic testing of scaled three-story special concentrically braced frame with strongback column

  • Chen, Chui-Hsin;Tsai, Yi-Rung;Tang, Yao
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.163-173
    • /
    • 2019
  • For Special Concentrically Braced Frame (SCBF), it is common that the damage concentrates at a certain story instead of spreading over all stories. Once the damage occurs, the soft-story mechanism is likely to take place and possibly to result in the failure of the whole system with more damage accumulation. In this study, we use a strongback column which is an additional structural component extending along the height of the building, to redistribute the excessive deformation of SCBF and activate more structural members to dissipate energy and thus avoid damage concentration and improve the seismic performance of SCBF. We tested one-third-scaled, three-story, double-story X SCBF specimens with static cyclic loading procedure. Three specimens, namely S73, S42 and S0, which represent different combinations of stiffness and strength factors ${\alpha}$ and ${\beta}$ for the strongback columns, were designed based on results of numerical simulations. Specimens S73 and S42 were the specimens with the strongback columns, and S0 is the specimen without the strongback column. Test results show that the deformation distribution of Specimen S73 is more uniform and more brace members in three stories perform nonlinearly. Comparing Drift Concentration Factor (DCF), we can observe 29% and 11% improvement in Specimen S73 and S42, respectively. This improvement increases the nonlinear demand of the third-story braces and reduces that of the first-story braces where the demand used to be excessive, and, therefore, postpones the rupture of the first-story braces and enhances the ductility and energy dissipation capacity of the whole SCBF system.

우주 발사체 추진제 탱크 및 축소 1단 모델의 전산 모드 해석 연구 (Computational Modal Analyses for the Propellant Tank and Small-Scaled First-Stage Models of Liquid-Propulsion Launch Vehicles)

  • 심창훈;김근상;김동건;김인걸;박순홍;박재상
    • 항공우주시스템공학회지
    • /
    • 제12권3호
    • /
    • pp.18-25
    • /
    • 2018
  • 액체 추진 우주 발사체의 모드 시험을 대체 혹은 보완할 수 있는 신뢰성 있는 전산 모드 해석 기법의 정립을 위하여 액체 추진제 및 플렌지 조인트의 유한요소 모델링 기법을 정립하였다. 본 연구에서는 추진제 탱크 모델과 발사체 1단 축소 모델에 대하여 MSC.NASTRAN을 이용하여 전산 모드 해석을 수행 후, 모드 시험의 고유 진동수를 비교하여 모델링 및 해석 기법을 검증하였다. 추진제 탱크의 경우 가상질량 기법을 이용하여 액체 추진제를 모델링하였으며, 추진제 탱크의 종 모드 (bell mode)를 잘 예측하였다. 액체 추진제를 포함한 발사체 1단 축소 모델에 대하여, 보정된 재료 물성치와 RBE2 요소를 사용한 플렌지 조인트의 모델링 기법은 각각의 플렌지에서 24개의 볼트 조인트를 사용한 모델에 대하여 10% 이내의 오차의 1차 및 2차 굽힘 모드의 고유 진동수를 적절하게 계산하였다.

단층대에 위치한 근접병설터널의 안정성평가 (Stability Estimation of the Closely-spaced Twin Tunnels Located in Fault Zones)

  • 황재석;김주환;김종우
    • 터널과지하공간
    • /
    • 제28권2호
    • /
    • pp.170-185
    • /
    • 2018
  • 단층대에 위치한 근접병설터널에 대하여 단층의 폭과 경사, 단층암의 물성을 달리한 수치해석과 모형실험을 통해 단층이 터널 안정성에 미치는 영향을 알아보았다. 병설터널 사이에 존재하는 필라의 강도/응력비를 구할 때는 필라 중앙부의 응력, 필라 전체의 평균응력, 필라 좌우단부의 응력을 각각 적용하였는데, 이중 마지막 방법은 단층대의 유무에 관계없이 터널 안정성의 보수적 평가에 적합하였고 터널 굴착시점을 실시간적으로 반영하였다. 필라 좌우단부의 응력을 적용하여 구한 강도/응력비는 단층의 폭과 경사가 커질수록, 단층암의 물성이 연약할수록 감소하는 경향을 보였다. 축소모형실험에서 단층을 포함한 모형은 불포함 모형에 비해 균열개시압력이 작았고, 단층의 폭이 큰 모형일수록 터널 안정성은 낮게 나타났다. 단층은 터널의 파괴거동에도 큰 영향을 미쳤는데, 단층이 없는 모형에서는 필라의 좌우하단부와 양쪽터널 측벽부에서 수평방향의 균열이 발생하였지만, 단층을 포함한 모형에서는 필라부 단층대에서 경사진 균열이 발생하였다.

터널 축소모형실험을 통한 이방성 암반내 록볼트의 보강효과 검토 (Evaluation of Reinforcement Effect of Rock Bolts in Anisotropic Rock Mass Using Tunnel Scaled Model Tests)

  • 김종우
    • 터널과지하공간
    • /
    • 제28권5호
    • /
    • pp.442-456
    • /
    • 2018
  • 본 연구에서는 터널의 축소모형실험을 통해 이방성 암반에 설치되는 록볼트의 보강효과를 검토하였다. 이를 위해 터널규격, 암석강도, 이방성 경사, 측압계수를 달리한 두 가지 터널사례를 실험하였다. 구슬달린 자수용 시침핀을 사용하여 전면접착식 D25 이형봉강 록볼트를 모델링하였고 이들을 모형터널의 천반과 측벽에 체계적으로 설치하였다. 첫 번째 사례에서, 무지보 모형은 터널 천정부에서 초기균열이 발생하였지만 록볼트 설치 모형은 록볼트가 설치되지 않은 영역인 터널 바닥부에서 초기균열이 발생하였다. 또한, 록볼트 설치 모형은 무지보 모형에 비해 균열개시압력과 최대압력이 각각 11%, 7% 더 컸고, 이방성 암반의 불연속면이 터널의 파괴거동에 미치는 영향은 작아져서 록볼트의 보강효과를 실험적으로 검증할 수 있었다. 지보패턴을 달리 적용한 두 번째 사례에서는, 록볼트의 길이와 수량이 큰 모형일수록 균열개시압력이 크고 하중에 따른 터널면적 축소비율은 작게 나타나, 록볼트의 길이와 수량을 증가시킬수록 록볼트의 성능이 향상됨을 알 수 있었다.

축소모형 실험을 통한 벽체의 열관류 측정 (Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test)

  • 장윤성;김세종;심국보;이상준;한영중;박용건;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.884-889
    • /
    • 2015
  • 구조용 부재의 단열성능에 대한 적절한 평가와 냉난방에너지에 대한 합리적 제어는 건물의 에너지효율을 향상시키기 위하여 매우 중요하다. 한국의 일반적인 주택 난방방식은 바닥난방이다. 이와 같은 복사난방방식은 국내의 지정학적인 조건 또는 기후에 적합할 뿐만 아니라 온열감에 따른 정서적 안정감을 준다는 장점을 가진다. 국내의 바닥난방시스템을 적용하여, 목조공간과 콘크리트조 공간을 대상으로 축소모형을 제작하였다. 천장은 스티로폼으로 단열하고 벽과 바닥은 각각 합판과 콘크리트로 구성하였다. 바닥에는 난방필름을 부착하였다. 바닥난방에 따른 실내의 온도분포는 열전대로 측정하였고, 벽체 표면의 온도는 적외선 열화상 카메라로 측정하였다. 목조주택의 에너지효율 향상을 위한 데이터베이스 구축을 위해 축소모형의 단열성능을 평가하였다. 다양한 벽체와 바닥구성을 지닌 모형들의 단열성능평가 자료는 실제 주택의 열환경 분석시 참고기준으로 이용될 수 있을 것으로 기대된다.