• Title/Summary/Keyword: scale removal

Search Result 1,230, Processing Time 0.025 seconds

The awareness of dental hygienist regarding the content of clinical practice education and importance of duty (임상실습 교육내용 및 업무중요도에 관한 치과위생사의 인식)

  • Kim, Chang-Hee;Shin, Sun-Jung;Shin, Myong-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.6
    • /
    • pp.1067-1080
    • /
    • 2017
  • Objectives: This study analyzed the perception towards clinical practice education content held by dental hygiene students in dental institutions and their perceived importance of dental hygienists' clinical duties. Methods: The subjects of this study were 182 dental hygienists who were working at dental institutions in Seoul, Gyeonggi, and Chungcheong areas. A survey was conducted with a self-administered questionnaire. In the questionnaire, the clinical practice contents were classified into observation, preparation, and performance, and the importance of clinical duty was measured with a 3-point scale. For the clinical practice contents and the importance of duty, descriptive statistics and chi-square test were performed, and the study results were analyzed using STATA 11.0. Results: With regard to clinical practice contents, observation was mainly performed in oral & maxillofacilal radiology, preventive dentistry, periodontal medicine and oral medicine. In primary care and infection control, practice and observation were mainly performed. In the department of orthodontics and pediatric dentistry, observation and preparation were mainly conducted, while in oral surgery, conservative dentistry observation, preparation and practice were all conducted. With regard to clinical practice contents according to the dental institution, there were statistically significant differences in the type of dental institution and the duty (p>0.05). In terms of the importance of dental hygienist's duty, infection control, toothbrushing education for each patient, removal of plaque, and patient education after surgery were considered important. Conclusions: For clinical practice of the dental hygiene department, the education contents should be standardized in accordance with the importance of the dental hygienist's duty, a protocol for operation of practice should be developed, and a method of standardization of evaluation should be sought in the future.

Evaluation of the Biogas Productivity Potential of Fish Waste: A Lab Scale Batch Study

  • Kafle, Gopi Krishna;Kim, Sang Hun
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.302-313
    • /
    • 2012
  • Purpose: The biogas productivity potential of fish waste (FW) was evaluated. Methods: Batch trials were carried out in 1.3 L glass digesters kept in a temperature controlled chambers at $36.5^{\circ}C$. The first order kinetic model and the modified Gompertz model were evaluated for biogas production. The Chen and Hashimoto model was used to determine the critical hydraulic retention time (HRT $_{Critical}$) for FW under mesophilic conditions. The feasibility of co-digestion of FW with animal manure was studied. Results: The biogas and methane potential of FW was found to be 757 and 554 mL/g VS, respectively. The methane content in the biogas produced from FW was found to be 73% and VS removal was found to be 77%. There was smaller difference between measured and predicted biogas production when using the modified Gompertz model (16.5%) than using first order kinetic model (31%). The time period for 80%-90% of biogas production ($T_{80-90}$) from FW was calculated to be 50.3-53.5 days. Similarly, the HRT $_{Critical}$ for FW was calculated to be 13 days under mesophilic conditions. The methane production from swine manure (SM) and cow manure (CM) digesters could be enhanced by 13%-115% and 17%-152% by mixing 10%-90% of FW with SM and CM, respectively. Conclusions: The FW was found to be highly potential substrate for anaerobic digestion for biogas production. The modified Gompertz model could be more appropriate in describing anaerobic digestion process of FW. It could be promising for co-digestion of FW with animal manure.

Pain Control for Hydrofluoric Acid Chemical Burn Using EMLA® creams (EMLA® 연고를 이용한 불산 화학 화상의 통증 조절)

  • Choi, Hwan Jun;Song, Jin Woo;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.113-117
    • /
    • 2009
  • Purpose: Although Hydrofluoric acid(HF) is not a strong acid when compared to other hydrogen halides, it is a feared corrosive and is particularly dangerous at higher concentrations. HF burns are characterized by symptoms, often delayed and localized with diluted HF solutions, to include erythema, edema and severe pain. Pain, a well known symptom following exposure to calcium binding. And, EMLA$^{(R)}$ cream is a topical formulation based upon the eutectic mixture of lidocaine and prilocaine and is used in clinical settings to provide pain relief undergoing superficial surgical procedures. The aim of this study is to evaluate effects of EMLA$^{(R)}$ cream, pain - control dressing on the treatment for HF injury wound. Methods: From June 2007 to June 2008, this study was carried out with 10 patients who had HF partial thickness burns. We were applied topically EMLA$^{(R)}$ cream to injured wound with vaseline gauze and 10% calcium gluconate wet gauze dressings. As a principle, in the emergency treatment, partial or complete removal of the bullae along with copious washing with normal saline was done, depending on the degree of HF invasion of the distal digital extremities. The effect of dressing was investigated by visual analogue pain scale. Results: We therefore reviewed 10 cases of HF - induced pain and pain relief treatment principle. The 10 cases who came to the hospital nearly immediately after the injury healed completely without sequelae and EMLA$^{(R)}$ related complications. Conclusion: Proper initial treatment of HF burns are important, if not promptly recognized and properly treated, for produce serious injury. Topical EMLA$^{(R)}$ cream remain a powerful, new advancement for minimizing HF - related pain during dressing procedures. When used appropriately, topical EMLA$^{(R)}$ cream can provide a safe and effective alternative to other forms of HF - pain control treatment.

Performance Enhancement of Anaerobic Treatment of Waste Sludge by Chemical Pretreatment (화학적 전처리를 통한 혐기성 슬러지 처리효율의 향상)

  • 허준무;박종안;손부순
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.16-25
    • /
    • 1998
  • Laboratory-scale experiment using anaerobic fluidized bed reactor was carried out to investigate the prehydrolysis step with caustic soda on the treatment efficiency of anaerobic sludge treatment, since the overall rate-limiting step for the complete anaerobic digestion of sludge was the hydrolysis step by extracellular bacterial enzymes of insoluble polymeric molecules. Reactors received a sludge which had not been pretreated, a 50-50 mixture of pretreated and untreated sludge, and the fully pretreated sludge. Hydraulic retention time of 10, 5, 2.5 days and 1 day were applied with an respective equivalent organic loading rate of 1.17, 2.23, 4.17, 11.24 gCOD/L/d. Reactor with the untreated sludge did not archieve adequate digestion even at the HRT of 5 days, and reactor, which received the 50-50 mixture, operated well at the HRT of 5 days, but began to show signs of unstable digestion at the HRT of 2.5 days. While, reactor, which was fed the hydrolyzed sludge, operated reasonably well at the 2.5 days, but was showing somewhat decrease in removal efficiencies. Results, therefore, have substantiated that the limiting reaction in the anaerobic treatment process is hydrolysis. The soluble COD did not significantly accumulate in the reactor as organic acid form, even when they were highly stressed. It was believed that this resistance to a build-up of organic acids and soluble COD behavior was mainly due to the maintenance of the methane bacteria in the fixed-film system which prevents washout as the organic loading increased. The anaerobic fluidized bed reactor was therefore effective for the digestion of waste activated sludge at short HRT.

  • PDF

Development of an Oil Mist Collector Equipped with Centrifugal De-oiling System (원심력 필터 재생기능을 갖춘 오일 미스트 여과 집진장치 개발)

  • Kim, Tae-Hyeung;Seo, Jeoung-Yoon;Ha, Hyun-Chul;Kim, Jong-Cheul;Cho, Jin-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.166-175
    • /
    • 2005
  • Health effects associated with metal working fluid (MWF) exposures include dermatitis, respiratory disease, hypersensitive pneumonitis, and asthma. Frequently, occupational exposures to MWFs are controlled by ventilating an enclosure with an air cleaning unit that includes a fan preceded by various kinds of filtration. There are several kinds of air cleaning units used in machining centers. But the associated troubles have hindered from efficiently using these devices. The main problem is the relatively short period of filter replacement. The reason is that the air cleaning units usually do not have the de-oiling systems, thus leading the earlier clogging of filters and reducing the flow rate of hood. Thus, the first stage of study was conducted to overcome this problem by developing the new oil mist collector equipped with the easy de-oiling system. The principle of de-oiling is that the centrifugal force generated by spinning the drum covered by filter fabric separates oils from the filter fabric. It would be very similar to the spin-dry laundry. By adopting this de-oiling technique, the problems associated with the conventional oil mist collectors could be solved. Several tests/analyses were performed to make the lab-scale oil mist collector. The collection efficiencies and the de-oiling efficiencies of commercially available filter fabrics were tested. Subsequently, the endurance test were conducted by observing SEM photos of filter fabrics and measuring tensile strength/expansion coefficient after spinning the filter drum for 20 minutes at the different rotation speeds. By doing these experiments, the most appropriate filter fabric and rotation speed/duration were selected. Finally, the new oil mist collector was designed. In the near future, this device must be tested in the real machining center.

A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed (BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가)

  • Yoon, Chun-Gyeong;Shin, Ah-Hyun;Jung, Kwang-Wook;Jang, Jae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.

Immediate Breast Reconstruction using saline implant: Extension of pectoralis major muscle coverage with AlloDerm® (식염수 보형물을 이용한 즉시 유방 재건술: AlloDerm®을 이용한 대흉근 피복의 확장)

  • Hwang, Chang Heon;Kim, Eun Key;Eom, Jin Sup;Ahn, Sei Hyun;Son, Byung Ho;Kim, Tae Gon;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.161-166
    • /
    • 2009
  • Purpose: Using the implant for the breast reconstruction still remains the options, despite the breast reconstruction using autologous tissue is an ideal method. In this study, we used AlloDerm$^{(R)}$ to extend subpectoral pocket for covering implants to reduce implant related complications. Met hods : From January 2005 to June 2007, 18 breasts in 16 patients were reconstructed using implant and AlloDerm$^{(R)}$ immediately after mastectomy. Hospital records, database files, and clinical photographs were reviewed. A ten - point scale was used to evaluate the patient's satisfaction, with a range from 2(poor) to 10(excellent). Results: Mean age of the patients was 38.7 years at the time of operation. Mean weight of removed breast tissue was 287g. AlloDerm$^{(R)}$ was used to extend subpectoral coverage. Any systemic complication was not reported. Breast complication was developed in 4 cases. Implant removal or change was not experienced. Conclusion: Immediate breast reconstruction using Implant is useful methods for certain conditions, when donor tissue is insufficient and breast is non ptotic with round shape. In those cases, extension of muscle coverage using AlloDerm$^{(R)}$ could reduce complications and lead more acceptable results.

Neural Tract Injuries by Penetration of Foreign Body: a Diffusion Tensor Tractography Study

  • Kwon, Hyeok-Gyu;Hong, Ji-Heon;Kwon, Yong-Hyun;Lee, Mi-Young;Kim, Seong-Ho;Jang, Sung-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.3
    • /
    • pp.132-135
    • /
    • 2013
  • We presented with a patient who showed injury of the cingulum and fornix by penetration of a foreign body into the brain on diffusion tensor tractography (DTT). A 63-year-old man suffered a brain injury by a part of a power saw blade that was suddenly detached from a power saw during work. A part of the power saw blade penetrated his right frontal skull and advanced to the right posterior horn of the lateral ventricle. This penetration caused traumatic intracerebral hemorrhage in the right frontal lobe and intraventricular hemorrhage in the lateral ventricle. He underwent craniotomy and removal of intracranial foreign bodies (bony pieces and saw blade). The patient's Memory Assessment Scale scores were 74 (4%ile) for global memory, 78 (7%ile) for verbal memory, and 80 (9%ile) for visual memory. DTTs showed disruptions in the anterior portion of the fornical body, right fornical crus, the anterior portion of the right cingulum, and the middle portion of the left cingulum, compared to the control. It seems that the sustained memory impairment of this patient might be related to injury of the cingulum and fornix.

A Study on the Degradation Properties of MTBE in Solution using Ultrasound (초음파를 이용한 수용액 속의 MTBE 분해 특성 연구)

  • Kim, Heeseok;Yang, Inho;Oh, Jeill;Her, Nam Guk;Jeong, Sangjo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.522-529
    • /
    • 2009
  • To supply safe drinking water to areas lacking in water supply and drainage system, such as rural area and military bases in proximity to Demilitarized Zone, effective method for treating organic contaminants such as MTBE is required. This study focuses on seeking optimal conditions for effective degradation of MTBE using a bath type ultrasound reactor. Effectiveness of MTBE degradation by ultrasound is dependent on the frequency, power, temperature, treatment volume, initial concentration, catalyst, etc. In this study the degradation rate of MTBE by ultrasound was proportional to power/unit volume ratio and removal is relatively more efficient for 0.1 mM than for 1 mM of MTBE solution. Efficiency of ultrasound treatment for 1 mM MTBE solution was enhanced under bath temperature of $30^{\circ}C$ compared to $4^{\circ}C$, but the temperature effect was negligible for 0.1 mM MTBE solution. Also for 0.1 mM MTBE solution, effect of catalyst such as $TiO_2$ and $Fe^0$ on treatment speed was negligible, and zeolite even increases the time taken for the degradation. Under these specific experimental conditions of this study, the most determinant factor for degradation rate of MTBE in solution was frequency and power of ultrasound. The results have shown that a continuous ultrasound reactor system can be used for small scale remediation of organically polluted groundwater, under optimal conditions.

A Study on Ozonation of 4-nonylphenol (4-nonylphenol의 오존산화 처리반응에 관한 연구)

  • Lee, Cheal-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.736-743
    • /
    • 2017
  • In this study, 4-nonylphenol (4-NP), an endocrine disrupting chemical, was removed by ozone treatment processes under the various experimental conditions including UV irradiation, $TiO_2$ addition. The ozone flow rate and concentration were maintained at $1.0L{\cdot}min^{-1}$ and $70{\pm}5mg{\cdot}L^{-1}$. The pH, COD and TOC of the samples were obtained every 10 minutes for 60 minutes in laboratory scale batch reactor. We found that the combination of UV irradiation and $TiO_2$ addition for ozonation improves the removal efficiency of COD and TOC in 4-NP aqueous solution. In case of the $O_3/UV/TiO_2$ system, COD and TOC were greatly reduced to 85.3 ~ 94.0% and 89.2 ~ 97.2%, respectively. 4-NP degradation rate constants, $k_{COD}$ and $k_{TOC}$, were calculated based on the COD and TOC values. Significantly, $k_{COD}$ and $k_{TOC}$ were improved in the $O_3/UV/TiO_2$ treatment process compared with single $O_3$ process, because the oxidation and the mineralization of 4-NP were increased by generating of the hydroxyl radical. The $k_{COD}$ and $k_{TOC}$ were obtained to be $5.81{\times}10^{-4}{\sim}10.8{\times}10^{-4}sec^{-1}$ and $11.9{\times}10^{-4}{\sim}19.4{\times}10^{-4}sec^{-1}$ in the $O_3/UV/TiO_2$ process. Activation energy ($E_a$) of ozone oxidation reaction based on $k_{COD}$ and $k_{TOC}$ were increased in order of $O_3/UV/TiO_2$ < $O3/UV$ < $O_3/TiO_2$ < $O_3$ process. It was confirmed that the addition of $TiO_2$ and UV irradiation to the ozone oxidation reaction significantly reduced the $E_a$ value and the degradation of 4-NP.