• 제목/요약/키워드: scale alternative

검색결과 1,029건 처리시간 0.039초

콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가 (Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements)

  • 박성태;박준영;이재훈;김형배
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

Some Alternative Classes of Shrinkage Estimators for a Scale Parameter of the Exponential Distribution

  • Singh, Housila P.;Singh, Sarjinder;Kim, Jong-Min
    • 응용통계연구
    • /
    • 제25권2호
    • /
    • pp.301-309
    • /
    • 2012
  • This paper proposes some alternative classes of shrinkage estimators and analyzes their properties. In particular, some new shrinkage estimators are identified and compared with Pandey (1983), Pandey and Srivastav (1985) and Jani (1991) estimators. Numerical illustrations are also provided.

Two Sequential Wilcoxon Tests for Scale Alternatives

  • Mishra, Prafulla-Chandra
    • Journal of the Korean Statistical Society
    • /
    • 제30권4호
    • /
    • pp.679-691
    • /
    • 2001
  • Two truncated sequential tests are developed for the two-sample scale problem based on the usual Wilcoxon rank-sum statistic for two different dispersion indices - absolute median deviations, when the medians of the two populations X and Y are equal or known and sums of squared mean deviations, when the medians are either unknown or unequal. The first test is briefly called SWAMD test and the second SWSMD test. For the SWAMD test, the percentile points for both the one-sided and two-sided alternatives, (equation omitted) have been found by Wiener approximation and their values computed for a range of values of a and N; analytical expression for the power function has been derived through Wiener process and its performance studied for various sequential designs for exponential distribution. This test has been illustrated by a numerical example. All the results of the SWAMD test, being directly applicable to the SWSMD test, are not dealt with separately Both the tests are compared and their suitable applications indicated.

  • PDF

프란시스 수차의 설계조건 변동에 따른 수력학적 해석 (Analysis of Hydraulics Power according to Changable Design Conditions for Francis Turbines)

  • 최주석;김일수;문채주;김옥삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.690-692
    • /
    • 2005
  • Among many other alternative energy resources, small scale hydropower has been brought into attention as a reliable source of energy today, which had been relatively neglected since 1960s. Present low head of Francis turbines and small scale hydro turbines, however, have limitations in the minimum required head and flow rate for efficient operation. This study attempts to develope the Francis turbine which is expected to run efficiently even in very low head and small flow rate, so that the limitations on the conventional small scale hydropower could be alleviated and competition with other alternative energy sources in the changable design conditions could be attained. The Francis turbine of a new concept was designed based on changable design conditions, hydrodynamics and theory of power transmission.

  • PDF

프란시스 터어빈의 설계조건 변동에 따른 수력학적 특성해석 (Analysis of Hydraulics Power Characteristics According to Changable Design Conditions for Francis Turbines)

  • 김옥삼;최주석;김일수
    • 동력기계공학회지
    • /
    • 제9권3호
    • /
    • pp.39-43
    • /
    • 2005
  • Among many other alternative energy resources, small scale hydropower has been brought into attention as a reliable source of energy today, which had been relatively neglected since 1960s. Present low head of Francis turbines and small scale hydroturbines, however, have limitations in the minimum required head and flow rate for efficient operation. This study attempts to develope the Francis turbine which is expected to run efficiently even in very low head and small flow rate, so that the limitations on the conventional small scale hydropower could alleviated and competition with other alternative energy sources in the changable design conditions could attained. The Francis turbine of a new concept was designed based on changable design conditions, hydrodynamics and theory of power transmission. The result of the study shows that two stages runner is more efficient, cheaper in construction, faster responding, and easier maintaining than single stage runner of Francis turbine

  • PDF

Noninformative Priors for the Common Scale Parameter in the Inverse Gaussian Distributions

  • Kang, Sang-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제15권4호
    • /
    • pp.981-992
    • /
    • 2004
  • In this paper, we develop the noninformative priors for the common scale parameter in the inverse gaussian distributions. We developed the first and second order matching priors. Next we revealed that the second order matching prior satisfies a HPD matching criterion. Also we showed that the second order matching prior matches alternative coverage probabilities up to the second order. It turns out that the one-at-a-time reference prior satisfies a second order matching criterion. Some simulation study is performed.

  • PDF

고해상도 위성영상을 이용한 축척 1/10,000 수치지도 제작 (1/10,000 Scale Digital Mapping using High Resolution Satellite Images)

  • 이병환;김정희;박경환;정일훈
    • 한국지리정보학회지
    • /
    • 제3권2호
    • /
    • pp.11-23
    • /
    • 2000
  • 본 논문은 항공사진측량이 통제되고 있는 수도권 북부 지역 중 파주시 교하지역을 대상으로 러시아의 2m 급 고해상도 인공위성영상인 Alternative 위성영상을 이용하여 1:10,000 축척의 수치지도제작을 위한 방법과 그 적용에 관한 연구이다. 주요 방법론으로는 MK-4(공간해상도 8m) 스테레오 위성영상으로 수치표고모델(DEM)을 추출하여 정사보정을 하였으며, GPS 측량을 통해 지상기준점(GCP)을 얻어 정밀한 기하보정을 하였다. 한편, 현장 지리조사로 얻은 자료를 이용하여 각 레이어별 스크린 디지타이징을 하였으며 그 정확도는 평면위치에서 평균제곱근(RMS)오차가 ${\pm}0.4m$, 수직에서의 RMS 오차는 ${\pm}15m$였다. 따라서 평면위치 오차에 대해서는 NGIS 수치지도의 정확도를 만족시키는 한편, 지리 조사를 통해 얻은 자료를 추가함으로서 도시계획을 위한 현황도 등으로 활용가치가 충분한 것으로 판단된다.

  • PDF

유로변경식 부상여재 생물여과시스템을 이용한 하수고도처리 (Advanced Wastewater Treatment Using Biofilter System with Floating Media under Alternative Flow)

  • 류홍덕;이정훈;이상일
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.250-257
    • /
    • 2006
  • The objective of this study is to propose an alternative process for the small sewage treatment plants in rural communities. A biofilter has been used for biological wastewater treatment, which is becoming the alternative to the conventional activated sludge system. The proposed process used in this study, which is packed with floating media (i.e. expanded polystylene), has advantages of biofilter system and alternative flow system and they are incorporated into one process. Pilot and bench scale studies were performed using domestic wastewater. In the results of pilot plant study, it was observed that the stable effluent water quality was achieved and it met the present effluent criteria of suspended solid (SS), organic matters, T-N and T-P. In the study for determination of the cycle of backwashing, it was observed that the cycle of backwashing depended on BOD loading rates of influents. In the BOD loading rates of $0.5kg\;BOD/m^3{\cdot}day$ and $1.0kg\;BOD/m^3{\cdot}day$, the backwashing cycle of 28 hour and 16 hour were needed, respectively. The optimum backwashing time was 120~80 seconds at the media expansion rate of 50%. In the removal of SS, organic matters, T-N and T-P, SS removal was rather achieved by physical filtration than biological mechanism and the removal of organic matters except for SS, T-N and T-P were mainly rather achieved by biological mechanism than physical filtration. In bench-scale study, the effects of recirculation rate was investigated on removal of SS, TCOD, T-N and T-P. It was observed that the recirculation made removal efficiencies of SS, TCOD, T-N and T-P increased. Especially, in T-N removal, the increase of T-N removal efficiency of 40% was observed in the reicirculation rate of 1Q compared with 0Q.

간호사의 보완대체요법에 대한 태도 (Nurses' Attitudes Toward Complementary and Alternative Therapies)

  • 손행미
    • 성인간호학회지
    • /
    • 제14권1호
    • /
    • pp.62-72
    • /
    • 2002
  • Purpose: This study was performed to develop a scale for evaluation of attitudes toward complementary and alternative therapies (CAT) and to investigate nurses' attitudes toward CAT. Method: The subjects were 263 nurses working at a university hospital in Seoul and Inchon. The personally designed questionnaire was tested for its reliability and validity. Nurses' attitudes to CAT were evaluated using the questionnaire. Results: Cronbach's $\alpha$ coefficient was 0.7405. 23 items were selected by item analysis and 4 factors including application, therapeutic effect, social interest and communication about CAT were classified by factor analysis. The mean score of attitudes and its subcategories were high, especially that of communication was very high. Nurses had a positive response to CAT in several items; acceptance as nursing intervention, its therapeutic value, complement for conventional medicine, and open communication about CAT. Attitudes were different significantly according to education and number of working years. There were high relationships between attitudes and its subcategories except communication. Conclusion: The Scale of attitudes toward CAT was proven to be reliable and valid. Positive nurses' attitudes toward CAT will help the patients be provided with a proper and safe way to take CAT.

  • PDF