• 제목/요약/키워드: saturation coefficient

검색결과 249건 처리시간 0.026초

A Joint Transform Correlator Encryption System Based on Binary Encoding for Grayscale Images

  • Peng, Kaifei;Shen, Xueju;Huang, Fuyu;He, Xuan
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.548-554
    • /
    • 2019
  • A binary encoding method for grayscale images is proposed to address their unsatisfactory decryption results from joint transform correlator (JTC) encryption systems. The method converts the encryption and decryption of grayscale images into that of binary images, and effectively improves decrypted-image quality. In the simulation, we replaced unencoded grayscale images with their binary encoded counterparts in the JTC encryption and decryption processes, then adopted a median filter to suppress saturation noise while keeping other settings unchanged. Accordingly, decrypted-image quality was clearly enhanced as the correlation coefficient (CC) between a decrypted image and its original rose from 0.8237 to 0.9473 initially, and then further to 0.9937, following the above two steps respectively. Finally, optical experimental results confirmed that the proposed encryption system works correctly.

일방향 탄소섬유강화 복합재료의 기계적 성질에 미치는 수 환경의 영향 (Effect of Water Environment on the Mechanical Properties of Unidirectional CFRP)

  • 손선영;김재동;고성위
    • 한국해양공학회지
    • /
    • 제11권4호
    • /
    • pp.23-30
    • /
    • 1997
  • The purpose of this paper is to investigate the water environmental effect on the mechanical properties of carbon fiber/epoxy composites. Moisture concentration absorbed in CFRP under various water environment was calculated and degradation of mechanical properties for each wet composite laminates is investigated by performing the flexual and tensile test. The results show that moisture absorption is accelerated in higher temperature environment and under the same temperature sea water environment prompts more absorption than fresh water. As increasing the water temperature and moisture concentration tensile and flexual strength decreased as much as 25%-40% compared with dry condition.

  • PDF

에르븀 첨가 광섬유증폭기의 특성측정 (Characterization of Erbium-Doped Fiber Amplifier)

  • 한정희;이재승;주무정;심창섭
    • 전자공학회논문지A
    • /
    • 제30A권5호
    • /
    • pp.45-51
    • /
    • 1993
  • An erbium doped fiber amplifier(EDFA) pumped by aingle 1.48$\mu$m LD was fabricated, and its gain and noise characteristics were measured. As a signal source, 1548 nm wavelength DFB LD was used. The small signal net gain of the EDFA module was 21.8 dB with maximum gain coefficient 0.7dB/mW for the erbium fiber length of 17.6 m, the pump power of 58 mW, and an input signal power of -25 dBm, respectively. The saturation power of the EDFA was 1 dBm for the input signal power of -5 dBm and the noise figure, measured by using an optical spectrum analyzer, was 5.8 dB for the input signal power of -40 dBm.

  • PDF

유한요소법과 프라이자흐 모델을 이용한 동기형 릴럭턴스 전동기(Synchronous Reluctance Motor: SynRM)의 On-line 관측기시스템 특성해석 (The On-line Observer System Characteristics Analysis of Synchronous Reluctance Motor Using a Coupled FEM & Preisach Model)

  • 김홍석;이중호
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2103-2108
    • /
    • 2007
  • This study investigates the dynamic characteristics of Synchronous Reluctance Motor (SynRM), with segmental rotor structure, using finite element method in which the moving mesh technique is considered. The focus of this paper is the efficiency of on-line parameter identification system for position sensorless control of a SynRM considering saturation and iron loss. Comparisons are given with angle of the observer and those of proposed FEM & Preisach model of synchronous reluctance motor, respectively. The position sensorless control using identified motor parameters is realized, and the efficiency of the on-line parameter identification system is verified by experimental results.

포화된 정규압밀 점성토에서 비배수 공극수압의 거동(II) - 점탄성 해석 모델 - (The Behavior of Undrained Pore Water Pressure in Normally Consolidated and Saturated Clay(II) - Visco Elastic Analysis Model -)

  • 임성훈
    • 한국농공학회지
    • /
    • 제45권4호
    • /
    • pp.137-143
    • /
    • 2003
  • The initial condition of $\Delta \sigma_3 \;=\; \Delta u$ is used for analyzing the time dependent behavior of ground. This is based on the concept that the coefficient of pore water B is the unity on the condition of saturation. but some measured consolidation data in the field showed that the pore water pressure was not dissipated as time elapsed but it was maintained constant value or it's dissipation rate was slower than that of the predicted. and so the measured data of pore water pressure was not consistent with that of settlement. In this study, the rheological model for the pore water pressure behavior on undrained condition was induced and compared with the experiment data of the literature. The result showed that the suggested model was consistent well with the result of experiment, but the suggested model could not explain the effect of the decrease of void ratio according to consolidation.

Micro-flown 장비를 이용한 옥상녹화재료 음향 물성치 실험 (Using a Micro-flown device to measure acoustical properties of green roof systems)

  • 양홍석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.870-873
    • /
    • 2014
  • Green roof systems has widely been used on rooftop of buildings by considering environmental benefits in aspects of bio-diversity, storm-water runoff as well as noise reduction. To predict noise reduction effect by green roof systems, it is necessary to measure in-situ acoustical properties of the components by devices enabling in-situ measurements. In this study, Micro-flown, which is the state of the arts device to measure in-situ normalized impedance and absorption coefficient has been used to measure acoustical properties of green roof materials according to different water saturation condition in the materials.

  • PDF

Silk Fibroin 막에 관한 연구 (II) -Silk Fibroin 막에 대한 산성염료의 흡착- (Studies on Silk Fibroin Membranes(II) -Adsorption of Acid Dyes in Silk Fibroin Memberane-)

  • 최해욱;박수민;김경환
    • 한국염색가공학회지
    • /
    • 제6권3호
    • /
    • pp.60-66
    • /
    • 1994
  • With the view of studying on the dual adsorption mechanism of acid dyes in connection with the structural difference of silk fibroin, silk fiber and silk fibroin memberane were used for equilibrium dyeing at $60^{\circ}C$, $70^{\circ}C$, $80^{\circ}C$ and pH 3.2, pH 5.0. The dyes used were C.I.Acid Orange 7 and C.I.Acid Red 88 introduced aromatic hydrocabon into Acid Orange 7. From the adsorption isotherm experiment, the total uptake of dyes can be described by Langmuir sorption and Nernst partition. Nernst partition. Nernst partition coefficient $K_1$ decrease of crystalline regions and orientation. The saturation value S of Acid Red 88 were large than total amino group contents and it was attributed it hydrophobic bond. On the other hand, the standard afficity and enthalpy were increased with the in crease of hydrophobic part of dyes. Both $k_1$ and $K_2$ were decreased with the increase of pH, but $k_2$ were more effected than $K_1$.

  • PDF

Magnetic Properties of Fe3-x MnxO4 Thin Films by FMR

  • Kim, Ki-Hyeon;Kim, Young-Ho;Ha, Tae-Wook;Lee, Jeong-Sik;Park, Mann-Jang
    • Journal of Magnetics
    • /
    • 제2권2호
    • /
    • pp.38-41
    • /
    • 1997
  • Spinel ferrite thin films Fe3-x MnxO4 (x=0.000, 0.006, 0.0010, 0.015, 0.023) were prepared on the coverglass by ferrite plating technique. To investigate the uniaxial anisotrpy of the samples, the saturation and effective magnetization of the thin films were measured by VSM(vibrating sample magnetometer) and FMR(ferromagnetic resonance) measurements respectively. The spectroscopic splitting g factor were estimated from the ferromagnetic resonance curves. For x=0.000, 0.006, the effective magnetization was measured of temperatures form T=77 K to T=300 K. The results were analyzed in terms of Bloch's law Ms(T) = Ms(0) (1-BT3/2-CT5/2). The Bloch coefficient B, C were determined by fitting. Ms(0) was obtained by extrapolating Meff to 0 K. From this result, the spin wave stiffness constants D was also determined.

  • PDF

Wilson Plot을 이용한 만액식 증발기의 열전달계수 측정 (Measurement of Heat Transfer Coefficient in a Flooded Evaporator through Wilson Plot Method)

  • 윤필현;강용태;정진희
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.698-706
    • /
    • 2004
  • Heat transfer coefficients of enhanced tubes in a flooded evaporator are measured through Wilson Plot method. And the correlations are proposed to design a flooded evaporators. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. Usually the experiments have been conducted separately. But there have been many difficulties like setting up the equipments and measuring the wall temperature. Wilson Plot method makes it possible to measure the separated transfer coefficients at the same equipment through experimental skills. So the cost and time can be reduced. And the results are reliable enough to use for design. Heat transfer coefficients inside the tube were able to be correlated uniquely in spite of various outside conditions. Boiling heat transfer of R134a is more dependent on the saturation temperature and much higher than that of R123.

세관내 R-22, R-134a의 증발 전열 특성에 관한 연구 (Evaporation Heat Transfer Characteristics of R-22, R-134a in Small Diameter Tubes)

  • 홍진우;박승준;오종택;오후규
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1081-1089
    • /
    • 2000
  • Evaporating heat transfer coefficients of R-22 and R-134a were measured in smooth horizontal copper tubes with inner diameters of 1.77, 3.36 and 5.35mm, respectively. The experiments were conducted in a closed loop, which was driven by a magnetic gear pump. Experiments were performed for the following range of variables: mass velocity (200 to 400 kg/$m^2$.s), saturation temperature($0^{circ}C,; 5^{\circ}C$) and quality(0 to 1.0). Main results obtained are as follows: evaporating heat transfer coefficients in the small diameter tubes (ID<7mm) were observed to be strongly affected by various diameters and to differ from those in the large diameter tubers. The heat transfer coefficients of the small diameter tubes were higher than those of the large diameter tubs. And it was very difficult to apply some well-known previous predictions (Shah`s, Gungor-Winterton`s and Kandlikar`s correlation) to small diameter tubes.

  • PDF