• Title/Summary/Keyword: saturation coefficient

Search Result 250, Processing Time 0.026 seconds

Experimental detemination of Half-Saturation Coefficient for Nitrifying Bacteria by Infinite Dilution Method (무한희석법(無限稀釋法)을 이용한 질산화(窒酸化) 미생물(微生物) 반포화계수(半飽和係數) 결정(決定)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Byong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.62-69
    • /
    • 1998
  • To remove nitrogen from wastewater, ammonia nitrogen has to be oxidized to nitrate nitrogen before denitrification reaction which converts nitrate nitrogen to nitrogen gas. In order to understand nitrification, several mathematical models had been proposed and Monod type model has been accepted internationally. Since Monod type model consists of maximum substrate utilization rate, substrate concentration and half-saturation coefficient, these values have to be addressed before using Monod type model. Several experimental procedures to determine half-saturation coefficient have been developed, however, Infinite dilution method was known to be time saving procedure. In this study, the mathematical equations and experimantal procedures for Infinite dilution method are presented and this method is used to determine half-Saturation coefficient for nitrifying bacteria. As results, Infinite dilution method is proved that this coefficient can be determined within 8 hours and the values of half-saturation coefficient has a range of 0.728 and $0.455gNH_4{^+}-N/m^3$ and the average has $0.580gNH_4{^+}-N/m^3$ through 5 sets of experiments.

  • PDF

Control of a Segway with unknown control coefficient and input constraint

  • Park, Bong Seok
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.2
    • /
    • pp.140-146
    • /
    • 2016
  • This paper proposes a control method of the Segway with unknown control coefficient and input saturation. To design a simple controller for the Segway with the model uncertainty, the prescribed performance function is used. Furthermore, an auxiliary variable is introduced to deal with unknown time-varying control coefficient and input saturation problem. Due to the auxiliary variable, function approximators are not used in this paper although all model uncertainties are unknown. Thus, the controller can be simple. From the Lyapunov stability theory, it is proved that all errors of the proposed control system remain within the prescribed performance bounds. Finally, the simulation results are presented to demonstrate the performance of the proposed scheme.

Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Variation of Pull-out Resistance of Geogrid with Degree of Saturation of Soil

  • Yoo, Chungsik;ALI, TABISH
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • This paper presents the results of experimental investigation on the effect of degree of saturation of soil on the pullout behavior of a geogrid. Different test variables were taken into account while performing the experiment including the soil physical conditions based on water content and external loading applied. The soil used was locally available weathered granite soil. The tests included variations in saturation of about 90%, 80%, 70% and 45% (optimum moisture content). The pullout tests were performed according to ASTM standard D 6706-01. The results indicate that increasing the degree of saturation in the soil decreases the pull-out capacity, which in turn decreases the interface friction angle and interaction coefficient. The decrease in the pullout interface coefficient was observed to be around 12.50% to 33.33% depending on the normal load and degree of saturation of the soil. The test results demonstrated the detrimental effect of increasing the degree of saturation within the reinforce soil on the pullout behavior of reinforcement, thus on the internal stability. The practical inferences of the outcomes are analyzed in detail.

Measurements of Saturation Energy Denity and Small Signal Gain Coefficient Dependent on the Active Gas Pressure in XeCl Laser Amplifier (XeCl 레이저 증폭기의 활성기체 압력에 따른 포화 에너지 밀도와 소신호 이득계수 측정)

  • 김규옥;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.457-460
    • /
    • 1994
  • Dependence of saturation energy density and small signal gain coefficient on the active gas pressure in XeCl laser amplifier has been investigated. The saturation energy density was increased almost linearly as 1.3, 1.45, 2.0, and $2.3mJ/\textrm{cm}^2$ when the pressure of Xe and He were 30 and 2000 mb, and the pressure of HC] was varied as 34, 52, 73, and 92 mb. Whereas the small signal gain coefficient was measured to be 6.5, 7.5, 7.0, 7.0 %/cm, which shows that the small signal gain did not varies not so much.o much.

  • PDF

Measurement of Gain Coefficient and Saturation Power of CW Waveguide CO_2$$ Laser (연속발진 도파형 이산화탄소 레이저의 이득계수 및 포화출력 측정)

  • 이승걸;김현태;박대윤
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.162-168
    • /
    • 1990
  • Two ZnSe loss plates were installed in the resonator of waveguide CO2 laser which consisted of Pyrex capillary tube in order to change the internal loss. By rotating the loss plates, the output variations with the internalloss was measured on various discharge conditions. The variations could be explained by the Rigrod theory. and the saturation power and the unsaturated gain coefficient were determined by fitting of the experimental results. It was found that the saturation power increased while the unsaturated gain coefficient reduced as the discharge current or the gas flow rate increased.reased.

  • PDF

Optimum thickness of GaAs top layer in AlGaAs-based 850 nm VCSELs for 56 Gb/s PAM-4 applications

  • Yu, Shin-Wook;Kim, Sang-Bae
    • ETRI Journal
    • /
    • v.43 no.5
    • /
    • pp.923-931
    • /
    • 2021
  • We studied the influence of GaAs top-layer thickness on the small-signal modulation response and 56 Gb/s four-level pulse-amplitude modulation eye quality of 850 nm vertical-cavity surface-emitting lasers (VCSELs). We considered the proportionality of the gain-saturation coefficient to the photon lifetime. The simulation results that employed the transfer-matrix method and laser rate equations led to the conclusion that the proportionality should be considered for proper explanation of the experimental results. From the obtained optical eyes, we could determine an optimum thickness of the GaAs top layer that rendered the best eye quality of VCSEL. We also compared two results: one result with a fixed gain-saturation coefficient and the other that considered the proportionality. The former result with the constant gain-saturation coefficient demonstrated a better eye quality and a wider optimum range of the GaAs top-layer thickness because the resultant higher damping reduced the relaxation oscillation.

A simple practical method for determination of moisture transfer coefficient of mature concrete using a combined experimental-numerical approach

  • Chari, Mehdi Nemati;Shekarchi, Mohammad;Ghods, Pouria;Moradian, Masoud
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.367-388
    • /
    • 2016
  • In this paper, a simple practical method is introduced in which a simple weight measurement of concrete and finite element numerical analysis are used to determine the moisture transfer coefficient of concrete with a satisfactory accuracy. Six concrete mixtures with different water-to-cementitious material (w/cm) ratios and two pozzolanic materials including silica fume and zeolite were examined to validate the proposed method. The comparison between the distribution of the moisture content obtained from the model and the one from the experimental data during both the wetting and drying process properly validated the performance of the method.With the proposed method, it was also shown that the concrete moisture transfer coefficient considerably depends on the pore water saturation degree. The use of pozzolanic materials and also lowering w/cm ratio increased the moisture transfer coefficient during the initial sorption, and then, it significantly decreased with an increase in the water saturation degree.

Experimental Study on Evaporation Heat Transfer and Oil Effect in Micro-fin Tube Using $CO_2$ (마이크로핀관 내 $CO_2$의 증발 열전달과 오일 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.106-112
    • /
    • 2008
  • In this paper, the experimental results on evaporation heat transfer characteristics were reported for a micro-fin tube using $CO_2$. An experimental refrigerant loop had been established to measure the evaporation heat transfer coefficient and pressure drop of $CO_2$. Experiments were conducted for mass fluxes, heat fluxes, saturation temperatures and PAG oil concentrations. With increasing the heat flux and the saturation temperature, the evaporation heat transfer coefficient increased. At the higher mass flux, however, the exit vapor quality of the micro-fin tube was to be lower. The peak of the heat transfer coefficient was shifted toward low quality region. The evaporation pressure drop increased as the mass flux increased and the saturation temperature decreased. As PAG oil concentration increased, the evaporation heat transfer coefficient decreased and the dryout was delayed by oil addition.

Experimental Investigation on Flow Boiling of R-22 in a Alumium Extruded Tube (알루미늄 다채널 압출관 내 R-22 대류 비등에 관한 실험 연구)

  • Sim, Yong-Sup;Min, Chang-Keun;Lee, Eung-Ryul;Sin, Tae-Ryong;Kim, Nae-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1340-1345
    • /
    • 2004
  • Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with $D_h=1.41mm$ . The test range covered mass flux from 200 to 600 $kg/m^2s$, heat flux from 5 to 15 $kW/m^2$ and saturation temperature from $5^{\circ}C$ to $15^{\circ}C$ . The heat transfer coefficient curve shows a decreasing trend after a certain quality(critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique 'cross-over' of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations underpredict the low mass flux and overpredict the high mass flux data.

  • PDF