New Approach to Air Quality Management (대기오염관리의 새로운 접근방법)

  • 윤명조
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.25-48
    • /
    • 1993
  • International concern over the environmental pollution is ever increasing, and diversified countermeasures must be devised in Korea also. Global trend, damages, problems and countermeasures with respect to issues mentioned in the Rio Declaration, such as prevention of ozone layer destruction, reduction of migratory atmospheric pollution between neighboring countries, and prevention of global greenhouse effect, were discussed in this report. Conclusion of the report is summarized as follows : A. Measurement, Planning and Monitoring (1) Development and implementation of a global network for measurement and monitoring from the global aspects such factors as related to acid rain(Pioneer substances, pH, sulfate, nitrate), effect of global temperature(Air temperature, $CO_2$, $CH_4$, CFC, $N_2O$) and destruction of ozone layer($CFC_S$). (2) Establishment of network system via satellite monitoring movement of regional air mass, damage on the ozone layer and ground temperature distribution. B. Elucidation of Present State (1) Improvement and development of devices for carbon circulation capable of accurately forecasting input and output of carbon. (2) Developmental research on chemical reactions of greenhouse gas in the air. (3) Improvement and development of global circulation model(GCM) C. Impact Assessment Impact assessment on ecosystem, human body, agriculture, floodgate, land use, coastal ecology, industries, etc. D. Preventive Measures and Technology Development (1) Development and consumption of new energy (2) Development of new technology for removal of pioneer substances (3) Development of substitute matter for $CFC_S$ (4) Improvement of agriculture and forestry means to prevent the destruction of ozone layer and the greenhouse effect of the globe (5) Improvement of housing to prevent the destruction of ozone layer and the greenhouse effect of the globe (6) Development of new technology for probing underground water (7) Preservation of forest (8) Biomass 5. Policy Development (1) Development of strategy model (2) Development of long term forecast model (3) Development of penalty charge effect and expense evaluation methods (4) Feasibility study on regulations By establishing the above mentioned measures for environmentally sound and sustainable development to establish the right to live for humankind and to preserve the one and only earth.

  • PDF

Causes of Waste Problem and Strategics for Recycling in Economic Aspect (폐기물의 처리 및 재활용의 문제점과 대책)

  • 박대문
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.49-64
    • /
    • 1993
  • The present waste problems require a change of thinking with regard to conventional economics. It has been generally believed that competitive markets maximize social welfare. But, the other hand, a few economists argue that "the competitive markets cannot always be relied on to provide all goods in the efficient amount." One of the best examples of the latter contention is the environmental problem. What is the basic thinking of the conventional economics that causes this problems \ulcorner What is the present problem that requires the change of conventional economic thinking \ulcorner The environmental problem result from the conventional economic thinking such as pursuing the limitless of the Gross National Product(GNP), believing the increasing returns in economics of scale and the efficiency of competitive market. This economic principles, howe- ver, does not apply currently to public goods, especially environmental amenity and natural resource because the price of markets does not reflect the natural goods of services. We call this eternality. Externalizes are no considered by either buyers or sellers of goods of which production or use results in an eternality. This leads to market failure are causes an waste problem in the economic activities. Today, it is almost impossible to say in a word what the solution for waste problems is because they are by-products complicated and entangled human activities. In this paper, I have introduced the causes of environmental problems only from the economic point of view. I have also described the needs of conversion of conventional economic thinking. Firstly, sustainable development, maintaining the natural resources, should be the basis of the economic growth rather that pursuing the limitless growth of GNP. Secondly, an appropriate scale of human's production activity should be taken into account to reduce the impact to the natural environment. Thirdly, internalization of eternality is asked to correct the market failure. This requires the public policy such as imposing a talsubsidy, assigning a property right or implement a more detailed environmental quality standard through, because use of the natural resources can be. allocated optimally by the intervention of government or social associations.

  • PDF

A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent (하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구)

  • Paik, Ke-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.36-43
    • /
    • 2005
  • Prior to the study of the sewage treatment methods, water quality for Gwangju sewage of fluent was investigated from January to December, 2004 for sewage water reuse. Monthly mean values of BOD, SS, turbidity, total phosphorus and color were 4.1 mg/L, 2.9 mg/L, 0.8 NTU, 1.3 mg/L, and 27 unit, respectively. Jar-test was performed to investigate the removal efficiency of pollutants under the coagulation conditions of fast mixing for 5 min, slow mixing for 15 min and precipitation for 1hr. Here, alum and polyaluminium chloride (PAC) were used as coagulants to reduce color, turbidity, total phosphorus (TP) and total organic carbon (TOC) in sewage effluents. The results showed that PAC gave better efficiency in removing turbidity and dissolved phosphorus than alum. It was also found from the relative molecular weight (RMW) distribution analysis that organic matter over 1,000 Dalton (Da) was easily removed by coagulation and subsequently MF treatment, while it was not effective for less than 500 Da. Based on tis result, Natural organic matter (NOM) with lower molecular weight (< 500 Da) may cause harmful disinfectant by-product (DBP) after chlorine treatment. Thus, activated carbon adsorption seems to be required for the complete removal of DBP in the hybrid system.

Estimation of Personal Exposure on Nitrogen Dioxide Using Time Activity - Comparative Study between Seoul, Korea and Brisbane, Australia - (시간활동도를 이용한 이산화질소 개인노출 예측 - 한국의 서울과 호주의 브리스베인의 비교 연구 -)

  • 양원호;이기영;손현석;정문호
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.10-17
    • /
    • 2000
  • 현대 생활에서 대부분의 사람들은 90%이상을 실내(가정, 일반사무실, 실내작업장, 공공건물, 지하시설물, 상가, 음식점, 자동차, 지하철 등)에서 생활하기 때문에 실내공기질(indoor air quality)은 개인이 오염물질에 노출되는 주요한 요인이다. 이산화질소($NO_2$)는 고온의 연소과정에서 발생되는 부산물로써 차량, 발전소와 산업장 등에서 발생되고 있다. 실내에서 이산화질소의 농도는 가스레인지, 케로센(kerosene) 난방기, 흡연에 주로 영향을 받는다. $NO_2$는 호흡기 증상과 관련된 각종 질환을 유발시키는 것으로 보고되고 있다. 본 연구는 한국의 서울에서 직장인 95명의 시간활동도가 조사되었으며, 호주 브리스베인에서 직장인 57명의 시간활동도와 동시에 각 가정의 실내.외 및 직장의 $NO_2$ 농도를 측정하였다. 또한 개인 $NO_2$ 노출을 예상하여 각 도시의 빈도분포를 예상하였다. 본 연구의 결과를 보면 다음과 같다. 1. 서울의 95명의 직장인들은 실내에서 약 83.8%의 시간을 보냈으며, 브리스베인의 57명의 직장인들은 실내에서 약 88.3%의 시간을 보냈다. 2. 브리스베인에서 측정된 실내의 NO2 평균농도는 10.5ppb(${\pm}5.6$), 실외의 NO2 평균농도는 14.5ppb(${\pm}5.8$), 직장에서의 $NO_2$ 평균농도는 18.2ppb(${\pm}5.0$)였다. 개인의 $NO_2$ 노출은 평균 15.0ppb(${\pm}5.2$)였다. 개인의 $NO_2$ 노출은 실외의 $NO_2$ 농도(r=0.42)보다 실내의 $NO_2$ 농도(r=0.42)보다 실내의 NO2 농도(r=0.49)에 상관성이 더 높았다. 3. 시간 가중치 모델을 이용한 개인 $NO_2$ 노출은 측정된 개인 NO2 노출과 통계학적으로 상관성을 가지고 있었다(r=0.58). 예측된 개인 $NO_2$ 노출은 측정된 $NO_2$ 노출보다 낮게 나타났으며, 이것은 출퇴근 등에 의한 교통의 이동에 따른 노출 때문인 것으로 생각되었다. 4. $NO_2$ 농도 분포를 log-normal 분포, 시간활동도를 Normal 분포로 가정하고 Monte-Carlo 시뮬레이션을 했을 때 서울의 직장인의 개인 노출은 평균 36.7ppb(${\pm}10.9$)였으며, 브리스베인의 직장인의 개인 노출은 평균 13.7ppb(${\pm}4.1$)였다.

  • PDF

A survey on the content of inorganic materials in ground-water of Northern Gyeonggi area (경기북부지역 지하수의 지역별 미량무기물질 함유실태 조사연구)

  • 오조교;손진석;배용수;정은희;박진호;황선민;정연훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2004
  • Ground water samples were collected from residential, green" industrial, landfill and mining area and analyzed for 23 inorganics from March to October in 2002. The results are as follows; 1. The detection frequencies of inorganic materials such as As, Ba, B, Mo, Ca, Mg, Al, Cu, Fe, Mn, Zn, Na, K were 7.2∼77.1% which showed that these inorganics were detected in many ground waters. 2. The detection frequencies of 7 inorganics(Cd, Cr, Ph, Se, Sb, Be, Tl) were commonly low at ranging from 0.42 to 2.5%. These inorganics were contained in ground water partially. 3. Three inorganics such as Hg, Ni, Ag were not detected in any ground-water samples. 4. Compared to the other areas, ground water samples from landfill area contained greater concentration in many inorgainics and then showed higher levels in industral, residential, mining and green area in order. 5. Compared to noted concentrations of bottled water, inorganic minerals including Ca, Mg, Na, K related to taste were fluent in target samples. The results showed that the average concentrations of Mg, Na, K were 4.0 mg/l, 14.7 mg/l, 1.5 mg/l respectively. 6. The concentrations of inorganics such as Sb, Ba, Mo, Be, Tl, K in some ground water samples exceeded the water quality standards of WHO, the US and UK. Especially, Ba, Mo, K also showed relatively high detection frequencies so these inorganics need to be considered as analytes in Korea Drinking Water Regulation in further study.

The Removal Effect of Fine Particles Applied Platform Screen Door in Seoul Subway Station (지하철 역사 승강장의 PSD 설치에 의한 미세먼지 감소 효과)

  • Sohn, Jong-Ryeul;Jung, Young-Rim;Park, Hyun-Hee;Oh, Youn-Hee;Choi, Won;Kim, Soon-Geun
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.60-68
    • /
    • 2009
  • The most principal approach to improve indoor air quality(IAQ) of subway was to examine the fine particulate(PM-10) from the emission sources. Therefore, this study was carried on the investigation the fine particulate for comparison with the removal efficiency of PM-10 in divided the PSD(Platform Screen Door) and Non-PSD subway station from July, 2007 to May 2008. In the monitoring results, the range of PM-10 concentration of Non-PSD station was $44.6{\sim}116.5{\mu}g/m^3$ and the range of PM-10 concentration of PSD station was $23.9{\sim}81.1{\mu}g/m^3$. And then the range of PM-2.5 concentration of Non-PSD station was $17.4-56.6{\mu}g/m^3$, and then the range of PM-2.5 concentration of PSD station was $17.9{\sim}34.4{\mu}g/m^3$. In comparison with the results of the PSD and Non-PSD subway station, we found that the PM-10 removal efficiency of PSD was 30-40%. In conclusion, the PSD will be applied the effective facilities of decreasing PM-10 in subway station in Korea.

Removal of $NO_x$ by using of $TiB_2$ Photocatalysis ($TiB_2$ 광촉매를 이용한 $NO_x$ 제거)

  • Lee, Yong-Hwan;Choi, Im-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.112-115
    • /
    • 2009
  • This research was performed to purify water quality through removing T-N, and T-P and to estimating rate of $NO_x$ by the response of photocatalyst using ceramics. The ceramics was a mixtures of Titanium Diboride($TiB_2$) which is used to develop armored cars with excellent protective power and lightness, Olivine, and Hwangto with water and was furnaced for an hour at $1160^{\circ}C$. Hwangto and Olivine used in the study are produced at Haenam-gun, Jeonnam, and Andong-city, Gyeongsangbuk-do, respectively. The ground Hwangto and Olivine were seived through PR $100{\times}200$, and $TiB_2$ was a product of SIGMA ALDRICH. The experiment was performed under the sunlight, Mass flow controller was used for constant flow to pass through the pyrex reactor which was fully charged with furnaced ceramics. The concentration of $NO_2$ gas passed through the pyrex reactor was measured by Multi Gas Monitor. The reaction took for 60 minutes, The material was exposed to sunlight for 40 minutes. The sunlight was interrupted before and after the exposure for 10 minutes. The result showed that the concentration of $NO_2$ gas of the ceramics with $TiB_2$ and without $TiB_2$ became reduced and then maintained the same concentration under the sunlight, and became increased when the sunlight is interrupted. The $NO_2$ removing efficiency of the ceramics mixed with $TiB_2$ was 14~43% higher than that of the ceramics without $TiB_2$ under the sunlight. The study showed that the removing rate of $NO_2$ was 80% when the mixture rate of Hwangto, Olivine, and $TiB_2$ was 68%, 30% and 2%.

Environmental Pollution Control Industry in Korea (한국의 환경오염방지산업)

  • 이달우
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.53-68
    • /
    • 1992
  • Since 1962, Korea has made a remarkable progress with continuous success of Five-Year Economic Development Plans. Over the last 30 years, Korea has achieved a fast growth in various industries including heavy industry and chemical industry with rapid urbanization at the same time. The fast industrialization and urbanization brought about huge amount of hazardous/toxic substances and wastes. The environmental pollution problems have now emerged from regional concerns to overall social issues accordingly. The situation has come to a point where pollution control and environment preservation have become one of the nation's major policies. Following the recent Earth Summit of UNCED Conference held in Riode Janeiro in June 1992, where the topic was environmentally sound and sustainable development, awareness upon the importance of environmental preservation has been heightened globally, The environmental issues will gradually influence the international society more and more, politically as well as economically, The environmental pollution control industry in Korea started in the early 70's with the development of the nation's industrialization, As the people's awareness on pollution increases and environmental laws and enforcing regulations were established, demand for pollution control began to increase. The environmental pollution control business came to be recognized as an independent industry in the mid'70's. It should be evaluated properly that over the last 30 years, the Korean pollution control industry has supplied locally manufactured pollution control facilities to the increasing local demand. Concerning the quality and customer satisfaction, however, there are still many aspects which need to be improved compared with those of advanced countries. Although the start of the pollution control industry in Korea is just 10 to 15 years behind the advanced countries such as Japan and European countries, current gap in the environmental technology is rather considerable. And, studies should be made to find out the reasons for the current technology gap, and therefore, to implement solutions to improve the technology and competitiveness of the environmental pollution control industry in Korea.

  • PDF

Han River Management Policy (한강수질의 관리방안)

  • 심영섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.29-36
    • /
    • 1992
  • Among the rivers in Korea, the Han River is the largest, most important one, which runs through the Seoul metropolitan region in the west toward the yellow sea. In the Han River basin there live as many as 17.1 mil. people including appr, 11 mil, citizens in Seoul. The Seoul Metropolitan region, already containing appr. 40% of the nation's total populating, expectedly poses an ever-growing polluting burden to the Han River. Due to Korea's vigorous industrialization and heavy urbanization in the past quarter century, water pollution was observed to be increasing in the Han River until the mid-1980's, but thereafter the Han River began to improve little by little by virtue of the government's massive investment and all-out efforts in water preservation. Public awareness on the importance of environmental protection is increasing unprecedentedly. With a view to meeting people's growing demand for clean water and pleasant environment, the government established the "Comprehensive Mid-Term Environmental Conservation Plan" (1992∼1993) in 1991. According to the plan, 1,315 bil.won(1.7 bil.us$ ) is to be poured into the Han River Basin to install 113 water pollutant abatement plants including 43 treatment facilities. To successfully cope with the future's challenging need for the environmentally sound sustainable development, a variety of measures and an array of policies are going to be incorporated with emphasis on, -redistributing such polluting sources as population and industries -tightening control of the water pollutant discharge -restricting the pollution-accompanying land use -enhancing the assimilation capacity of the river -stirring up the public awareness and participation in the environment protection We hopefully anticipate that with those e(forts the Han River will improve as drawn in the attached "1996's Envisioned Han River Quality".

  • PDF

The measures to reduce sewer odor in South Korea through sewer odor reduction system in Los Angeles and San Francisco (Los Angeles와 San Francisco의 악취 저감 시스템을 통해 본 우리나라 하수도의 악취 저감 방안)

  • Ji, Hyonwook;Yoo, Sungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.445-451
    • /
    • 2018
  • Urban sanitary sewer systems can aid in preventing inundation, and can improve civil health by effectively disposing stormwater and wastewater. However, since sewage odor can cause adverse effects, numerous technical and administrative studies have been conducted for reducing such odor. European countries and the United States of America (USA) built modern sewer systems in the late 19th century, and have since been endeavoring to eliminate sewage odors. Several cities of the USA, such as Los Angeles (LA) that has a separate sewer system and San Francisco (SF) that has a combined sewer system, have produced and distributed odor control master plan manuals. Features common in the odor reduction plans of both these cities are that the odor reduction programs are operated in all the respective local regions and are supported by administrative systems. The primary aspectual difference between the two said programs is that the city of LA employs a sewage air purification system, whereas the city of SF controls the emission of major odor causing compounds. Compared to the existing sewer odor reduction systems of these two cities, South Korea is still in the initial phase of development. Through technical studies and policy implementations for sewer odor reduction, a foundation can be laid for improving the civil health quality.