• Title/Summary/Keyword: sampling rate of frequency

Search Result 276, Processing Time 0.022 seconds

2N-Point FFT-Based Inter-Carrier Interference Cancellation Alamouti Coded OFDM Method for Distributed Antennas systems (분산안테나 시스템을 위한 2N-점 고속푸리에변환 기반 부반송파 간 간섭 자체제거 알라무티 부호화 직교주파수분할다중화 기법)

  • Kim, Bong-Seok;Choi, Kwonhue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1030-1038
    • /
    • 2013
  • The proposed Alamouti coded OFDM effectively cancels Inter Carrier Interference (ICI) due to frequency offset between distributed antennas. The conventional Alamouti coded OFDM schemes to mitigate ICI utilize N-point Inverse Fast Fourier Transform/Fast Fourier Transform (IFFT/FFT) operations for OFDM modulation and demodulation processes with total N subcarriers. However, the performance degrades because ICI is also repeated in N periods due to the property of N-point IFFT/FFT operation. In order to avoid this problem, null data are used at the subcarriers with large ICI and thus, data rate decreases. The proposed scheme employs 2N-point IFFT/FFT instead of N-point IFFT/FFT in order to increase sampling rate. By increasing sampling rate, the amount of interference significantly decreases because the period of ICI also increases. The proposed scheme increases the data rate and improves the performance by reducing amount of ICI and the number of null-data. Furthermore, the gain of the performance and data rate of the proposed scheme is significant with higher modulation such as 16-Quadarature Amplitude Modulation (QAM) or 64-QAM.

The Fundamental Studies of the New Glow Discharge/Inductively Coupled Plasma Interface: Part Ⅰ. Preliminary Studies (새로운 글로우 방전/유도결합 플라스마 장치(GD/ICP Interface)에 대한 기초 연구: Part Ⅰ. 기초 연구)

  • Lee, Gae Ho;Kil, Hyo Shik;Kim, Hyung Seung;Gary M. Hieftje
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.182-192
    • /
    • 1999
  • The new GD/ICP-AES quick change over system has been developed and characterized. Within less than 15 minutes, ICP-AES could be switched to GD-AES and vise a versa. As a result, both solid and liquid samples could be analyzed in a very short period of time by the ICP/GD-AES quick change over system developed in our laboratory. The influences of the experimental variables, such as flow rate of coolant gas, flow rate of auxiliary gas, flow rate of sample carrier gas, sampling depth, orifice size of sampling cone, and rf (radio frequency) power on emission intensity have been presented. The detection limits of Cd(I) 228.8 nm, Mn (II) 257.61 nm, and Fe(II) 259.95 nm were found to be 3.86, 1.49, and 5.79 ppb, respectively. And linealities of the calibration curves were measured to be unity.

  • PDF

Comparison of the Effect of the Interpolation Function on the Performance of the Noise Source Imaging Technology (소음원 영상화 기술의 성능에 보간 함수가 미치는 영향 비교)

  • Park, Kyu-Chil;Yoon, Jong Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.268-274
    • /
    • 2016
  • To find the location of a random noise source present in the three-dimensional space is required at least four microphones. Using four microphones distributed in a three-dimensional space, noise source imaging technique was applied and evaluated on their performance. To compensate resolution problem which comes from both the position of the sensor array is fixed and the sampling frequency is low, up-sampling technique and interpolation function were applied. Five different interpolation methods were applied such as zero-padding, zero-order hold, first-order hold, spline function, and random signal padding. The up-sampling rate were chosen by two, four, eight times, and counting up 16 times. As a result, it was possible to more accurately estimate the position of the noise source according to the higher of the up-sampling rate. It also found that the first-order hold and the spline function's performance were slightly falling relative to other methods.

A Study on the Automatic Recognition of Korean Basic Spoken Digit Using Energy of Special Bandwidth (특정 대역 에너지를 이용한 한국어 기본 수자 음성의 백동 인식에 관한 연구)

  • Han, Hee;Kim, Soon-Hyob;Park, Kyu-Tae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.3
    • /
    • pp.5-12
    • /
    • 1982
  • Through the use of energy ratio of special bandwidths of basic vowels, recognition of Korean basic spoken digit is performed in logical combination with a zero-crossing rate and an energy parameter. In the experiments for recognition of the digits, the speech signal of spoken digits is filtered by a lowpass filter of which the cutoff frequency is 10KHz, and then sampled at 20KHz of sampling rate, In the speech signal processing, we used four FIR digital filters, and the order of filter lengths is 61, 120, 25, 25respectively. The filters are designed by using Remetz exchange algorithm.[13],[14] As a result, the recognition rate of 92% for the three speakers is obstained.

  • PDF

Designation of Bodytypes and Size Specifications for Designing of the Ready-made Jacket (신사복 상의 설계를 위한 체형의 호칭 분류와 사이즈 스팩;36세에서 43세 우리나라 남성을 대상으로)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1240-1247
    • /
    • 1999
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready-made garments especially jacket and dress shirts By the stratified sampling method data were collected by the real anthropometric measurement. Sample size was 263 subjects as the sample and their age range was from 36 to 43 years old 66 variables from the direct anthropometric data were applied to analyze. ANOVA is SPSSWIN 8.0 package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specificatios by the control dimensions. The drop values of 9,12 and 6 have the high coverage rate of 28.52% 23.44% respectively Obese body type ; H type HD type and HE type are composed of the majority of 55.47% of the subjects. According to the drop values size specifications and distribution of control dimensions are predicted About 69.82% of the expected frequency distribution were covered by 19 size specifications.

  • PDF

A Comparative Study on the Impulsive Noise Mitigation Algorithms for Orthogonal Frequency Division Multiplexing Systems (직교 주파수분할다중화 시스템을 위한 충격성 잡음 완화 알고리즘에 대한 비교 연구)

  • Ma, Shuang;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.5
    • /
    • pp.1051-1060
    • /
    • 2014
  • In this paper, performance of an orthogonal frequency division multiplexing (OFDM) system in an impulsive noise environment is analyzed. Here, it is verified that performance of the OFDM system with window nonlinearity, which is one of the impulsive noise mitigation algorithms, is dependent on the over-sampling rate and the size of window. With respect to the variation of those parameters, we also provide an appropriate region of threshold values that control amplitudes of the sampled waveform of received signals. As a result, a new combination of parameters which improves error performance of OFDM system in an impulsive noise environment as compared to the previously reported parameters is presented.

An integrated visual-inertial technique for structural displacement and velocity measurement

  • Chang, C.C.;Xiao, X.H.
    • Smart Structures and Systems
    • /
    • v.6 no.9
    • /
    • pp.1025-1039
    • /
    • 2010
  • Measuring displacement response for civil structures is very important for assessing their performance, safety and integrity. Recently, video-based techniques that utilize low-cost high-resolution digital cameras have been developed for such an application. These techniques however have relatively low sampling frequency and the results are usually contaminated with noises. In this study, an integrated visual-inertial measurement method that combines a monocular videogrammetric displacement measurement technique and a collocated accelerometer is proposed for displacement and velocity measurement of civil engineering structures. The monocular videogrammetric technique extracts three-dimensional translation and rotation of a planar target from an image sequence recorded by one camera. The obtained displacement is then fused with acceleration measured from a collocated accelerometer using a multi-rate Kalman filter with smoothing technique. This data fusion not only can improve the accuracy and the frequency bandwidth of displacement measurement but also provide estimate for velocity. The proposed measurement technique is illustrated by a shake table test and a pedestrian bridge test. Results show that the fusion of displacement and acceleration can mitigate their respective limitations and produce more accurate displacement and velocity responses with a broader frequency bandwidth.

Fabrication of High Frequency Magnetic Characteristics Measurement System Using Digital Oscilloscope and Computer Remote Control (디지털 오실로스코프와 컴퓨터 제어기법을 이용한 고주파 자기특성 측정장치 제작)

  • 김기옥;이재복;송재성;민복기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.6
    • /
    • pp.327-333
    • /
    • 1997
  • We designed and constructed the high frequency magnetic characteristics measurement system to measure core loss, B-H curve, permeability of toroidal ferrite core, amorphous core and various materials for high frequency application. The system consists of universal equipments such as digitizing oscilloscope, signal generator, power amplifier, PC in order to make upgrade easily. The power source is composed of waveform synthesizer and power amplifier ranging from DC to 20 MHz, and output signal H and B from sample core are digitized by oscilloscope with sampling rate 1 GS/ s per channel. Computer controls power source and oscilloscope, reads data from oscilloscope, displays analyzed waveform and saves data with file. The entire procedures finishes within few seconds.

  • PDF

HRTF Measurement and Its Application for 3-D Soung Localization

  • Kang, Kyeong Ok;Kang, Dong-Gyu;Hahn, Minsoo;Jho, Moon Jae;Jeong, Dae-Gwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3E
    • /
    • pp.50-55
    • /
    • 1997
  • Based on the anthropometric data of Korea male adults, a head and torso simulator(HATS) is constructed to measure its head related transfer functions (HRTFs) which can be used for three dimensional (3-D) sound localization. The HRTFs binaural impulse responses, are measured in an anechoic chamber using a burst maximum length sequence (MLS) signal of 65,535 samples and 32,768 samples acquisition at the sampling rate of 75.47kHz. Also measured are the impulse responses of a driving loudspeaker and some headphones for sound reproduction to get the exact HRTF of the HATS-alone. Through a post-processing procedure, the impulse-version HRTFs at the sampling frequency of 44.1 kHz, which have filter lengths of 512 points, are finally obtained. As an application of the measured HRTFs, a 3-D sound processor for headphone reproduction has been developed. The signal intervals to be processed can be selected and each interval is manipulated to have its diretionality and distance information by using corresponding HRTF and energy control.

  • PDF

Baseline Drift Reduction and Suppression of Power Line Noises in ECG Signal by Designing Multirate Digital Filter (다중레이트 디지털 필터 설계 및 심전도 신호의 기저선 변동 및 전원 잡음 제거)

  • Kim, Jeong-Hwan;Kim, Hyun-Tae;Park, Sang-Eun;Lee, Jeong-Whan;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.551-558
    • /
    • 2014
  • Baseline drift reduction and removal of power line noises in electrocardiogram are often necessary to avoid the distortions in extracting the fiducial features. With this aim, the multirate digital filtering algorithm is suggested to design and implement Finite Impulse Response or Infinite Impulse Response Filter by changing the sampling rate with omitting or interpolating intermediate ECG data. After the experimental simulations performed, we can conclude the fact that we can suppress the baseline wander and power line disturbances in ECG signal with reducing the computational complexities in which we do not keep the original and high sampling frequency.