• 제목/요약/키워드: sample points

검색결과 743건 처리시간 0.022초

A Test Procedure for Change in Level Occurring at Unknown Points

  • Lee, Jae-Chang;Song, Il-Seong
    • Journal of the Korean Statistical Society
    • /
    • 제18권1호
    • /
    • pp.38-45
    • /
    • 1989
  • A procedure is considered to the problem of testing whether there exist changes in location at possibly two points in a sequence of independent random variables which are successively drawn from normal population. A test statistics based on modified likelihood ratio is proposed and its asymptotic null distribution is derived through the stochastic process representation. A small sample power comparison is made by Monte Carlo method.

  • PDF

Nonparametric detection algorithm of discontinuity points in the variance function

  • Huh, Jib
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권3호
    • /
    • pp.669-678
    • /
    • 2007
  • An algorithm to detect the number of discontinuity points of the variance function in regression model is proposed. The proposed algorithm is based on the left and right one-sided kernel estimators of the second moment function and test statistics of the existence of a discontinuity point coming from the asymptotic distribution of the estimated jump size. The finite sample performance is illustrated by simulated example.

  • PDF

크리깅 대체모델을 이용한 순차적 신뢰성기반 최적설계를 위한 효율적인 제한조건경계 샘플링 기법 (An Efficient Constraint Boundary Sampling Method for Sequential RBDO Using Kriging Surrogate Model)

  • 김지훈;장준용;김신유;이태희;조수길;김형우;홍섭
    • 대한기계학회논문집A
    • /
    • 제40권6호
    • /
    • pp.587-593
    • /
    • 2016
  • 대체모델을 이용한 신뢰성기반 최적설계에서 최적해와 신뢰도의 정확성은 제한조건경계의 대체모델의 정확도에 영향을 받는다. 기존 제안된 제한조건경계 샘플링 기법은 제한조건경계에 실험점을 생성하여 이러한 정확성을 높일 수 있었다. 하지만, 제한조건경계 샘플링 기법은 최적해와 먼 부근의 제한조건경계에도 불필요한 실험점을 생성하여 과도한 계산비용이 발생한다. 본 논문에서는 크리깅 대체모델의 통계적 정보를 이용하여 최적해 근처의 제한조건경계에 실험점을 생성하는 효율적인 제한조건경계 샘플링 기법을 제안한다. 제안한 기법의 효율성과 정확성은 수학예제를 통하여 확인한다.

Investigation of the superconducting properties of YBCO coated conductor based on LTSLHPM

  • Park, H.Y.;Park, S.K.;Ri, H.C.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2013
  • We transformed the shape of a YBCO sample with striation to reduce hysteresis and ac losses. And we chose several points to analyze in detail and visualized superconducting properties like critical transition temperature, distribution of the magnetic field, distribution of the current density and hysteresis in a non-destructive manner based on Low Temperature Scanning Laser Hall Probe Microscopy (LTSLHPM) to examine the homogeneity of the sample.

Soil sampling plan design of key facilities for denuclearization based on data quality objective process

  • Jeon, Yeoryeong;Kim, Yongmin
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3788-3794
    • /
    • 2022
  • The possibility of denuclearization of the Korean Peninsula has been continuously debated, and the initiative participation of the Republic of Korea has necessitated preemptive measures against neighboring countries. In this study, we present a proposal for formulating a site survey plan when the amount of site information provided is insufficient and the accuracy of the information is not guaranteed. Considering a case wherein "a soil sample analysis is used to determine the presence or absence of nuclear activity" in a radiochemical laboratory, which is a typical key facility for denuclearization, the optimal soil sample collection plan is designed based on international guidelines and public information. In the event of denuclearization, a scenario that is not based on the expertise of the sample collector is set, and the data quality objective (DQO) process is applied to ensure reality. Consequently, the primary sample collection points can be derived in consideration of accessibility, and the sample collection scale can be adjusted according to the cost. By applying the DQO process to ensure sample representativeness and reality, reliable and resource-efficient soil sample collection can be achieved in radiochemical laboratories and other denuclearization facilities.

Estimation of error variance in nonparametric regression under a finite sample using ridge regression

  • Park, Chun-Gun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권6호
    • /
    • pp.1223-1232
    • /
    • 2011
  • Tong and Wang's estimator (2005) is a new approach to estimate the error variance using least squares method such that a simple linear regression is asymptotically derived from Rice's lag- estimator (1984). Their estimator highly depends on the setting of a regressor and weights in small sample sizes. In this article, we propose a new approach via a local quadratic approximation to set regressors in a small sample case. We estimate the error variance as the intercept using a ridge regression because the regressors have the problem of multicollinearity. From the small simulation study, the performance of our approach with some existing methods is better in small sample cases and comparable in large cases. More research is required on unequally spaced points.

Depth-Based rank test for multivariate two-sample scale problem

  • Digambar Tukaram Shirke;Swapnil Dattatray Khorate
    • Communications for Statistical Applications and Methods
    • /
    • 제30권3호
    • /
    • pp.227-244
    • /
    • 2023
  • In this paper, a depth-based nonparametric test for a multivariate two-sample scale problem is proposed. The proposed test statistic is based on the depth-induced ranks and is thus distribution-free. In this article, the depth values of data points of one sample are calculated with respect to the other sample or distribution and vice versa. A comprehensive simulation study is used to examine the performance of the proposed test for symmetric as well as skewed distributions. Comparison of the proposed test with the existing depth-based nonparametric tests is accomplished through empirical powers over different depth functions. The simulation study admits that the proposed test outperforms existing nonparametric depth-based tests for symmetric and skewed distributions. Finally, an actual life data set is used to demonstrate the applicability of the proposed test.

시점 변화에 강인한 특징점 정합 기법 (Feature Matching Algorithm Robust To Viewpoint Change)

  • 정현조;유지상
    • 한국통신학회논문지
    • /
    • 제40권12호
    • /
    • pp.2363-2371
    • /
    • 2015
  • 본 논문에서는 FAST(Features from Accelerated Segment Test) 특징점 검출기와 SIFT(Scale Invariant Feature Transform) 특징점 서술자(descriptor)를 사용하여 시점 변화에 강인한 특징점 정합 기법을 제안한다. 기존의 FAST 기법은 영상의 에지 부분을 따라서 불필요하게 특징점을 많이 추출하게 되는데 이러한 단점을 주곡률(principal curvatures)을 적용하여 개선한다. 추출된 특징점을 SIFT 서술자를 통해 기술하고 시점이 다른 두 영상으부터 구해진 정합쌍에 RANSAC(RANdom SAmple Consensus) 기법을 통하여 호모그래피(homography)를 계산한다. 시점 변화에 강인한 특징점 정합을 위해서 기준 영상의 특징점들을 호모그래피 변환을 통해 변경된 좌표와 시점이 다른 영상의 특징점 좌표간의 유클리디언(Euclidean) 거리를 통해 정합쌍을 분류한다. 같은 물체나 장소에 대해 시점이 변화된 여러 영상에 대한 실험을 통해서 제안하는 정합 기법이 적은 계산량으로 기존의 특징점 정합 기법보다 우수한 성능을 보여주는 것을 확인하였다.

원샷 시스템의 저장 신뢰성 추정 정확성에 대한 샘플링 시점의 영향 분석 (Influence Analysis of Sampling Points on Accuracy of Storage Reliability Estimation for One-shot Systems)

  • 정용호;오봉식;이홍철;박희남;장중순;박상철
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권1호
    • /
    • pp.32-40
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the effect of sampling points on accuracy of storage reliability estimation for one-shot systems by assuming a weibull distribution as a storage reliability distribution. Also propose method for determining of sampling points for increase the accuracy of reliability estimation. Methods: Weibull distribution was divided into three sections for confirming the possible to estimate the parameters of the weibull distribution only some section's sample. Generate quantal response data for failure data. And performed parameter estimation with quantal response data. Results: If reduce sample point interval of 1 section, increase the accuracy of reliability estimation although sampling only section 1. Even reduce total number of sampling point, reducing sampling time interval of the 1 zone improve the accuracy of reliability estimation. Conclusion: Method to increase the accuracy of reliability estimation is increasing number of sampling and the sampling points. But apply this method to One-shot system is difficult because test cost of one-shot system is expensive. So propose method of accuracy of storage reliability estimation of one-shot system by adjustment of the sampling point. And by dividing the section it could reduce the total sampling point.

담배 중 멘톨 분석에 대한 불확도 측정 (Uncertainty in Determination of Menthol from Mentholated Cigarette)

  • 장기철;이운철;백순옥;한상빈
    • 한국연초학회지
    • /
    • 제22권1호
    • /
    • pp.91-98
    • /
    • 2000
  • This study was carried out to evaluate the uncertainty in the analysis of menthol content from the mentholated cigarette. Menthol in the sample cigarette was extracted with methanol containing an anethole as an internal standard, and then analyzed by gas chromatography. As the sources of uncertainty associated with the analysis of menthol, were the following points tested, such as the weighing of sample, the preparation of extracting solution, the pipetting of extracting solution into the sample, the preparation of standard solution, the precision of GC injections for standard & sample solution, the GC response factor of standard solution, the reproducibility of menthol analysis, and the determination of water content in tobacco, etc. For calculating the uncertainties, type A of uncertainty was evaluated by the statistical analysis of a series of observation, and type B by the information based on supplier's catalogue and/or certificated of calibration. Sources of uncertainty were subsequently included and mathematically combined with the uncertainty arising from the assessment of accuracy to provide the overall uncertainty. It was shown that the main source of uncertainty came from the errors in the reproducibility of menthol and water determination, the purity of menthol reference material in the preparation of standard solution, and the precision of GC injections for sample solution. The errors in sample weighing and volume measurement contributed relatively little to the overall uncertainty. The expanded uncertainty in the mentholated cigarettes, Korean and American brand, at 0.95 level of statistical confidence was $\pm$0.06 and $\pm$0.07 mg/g for a menthol content of 1.89 and 2.32 mg/g, respectively.

  • PDF