• Title/Summary/Keyword: same distance effect

Search Result 307, Processing Time 0.025 seconds

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Effect of Difference between Soil- and Air-temperatures on Agronomic Characters of a Barley Cultivar Kangbori(Hordeum vulgare L. Emend. Lamark) (기온과 지온의 차이가 강보리생육 및 수량에 미치는 영향)

  • 하용웅
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.4
    • /
    • pp.358-363
    • /
    • 1989
  • This experiment was carried out to analyze the effect of different air- and soil-temperatures on the major traits of barley including grain yield. Outdoor growth cabinet and soil temperature equipment were used for this study to control the air- and soil-temperatures during the plant growth. Earlier heading appeared at the higher soil-temperature under same air-temperature, and more stems showed when conbined with 25$^{\circ}C$ of air-temperature and l0$^{\circ}C$ soil-temperature than any treatment. There appeared, however, the longest spike length, awn length, distance from flag-leaf to spike and culm length at 20$^{\circ}C$ of air-temperature and 10$^{\circ}C$ or 15$^{\circ}C$ of soil-temperatures. As far as grain yields are concerned, there showed the highest yield on the condition combined with 20$^{\circ}C$ of air-temperature and 10$^{\circ}C$ of soil-temperature.

  • PDF

An Experimental Study on the Application of End-Expanded Soil Nailing Method (선단확장식 소일네일링 공법의 적용성에 관한 실험적 연구)

  • Lee, Sang-Eun;Jang, Yun-Ho;Moon, Chang-Yeul;Jeong, Gyo-Cheol;Park, Young-Sun
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 2007
  • The peculiarity of end-expanded soil nailing method(EESNM) is in fixing the wedge-type steel body spreaded by collars and grouting its surroundings by cement milk within soils, after extending hole bottom over drilling hole diameter with top drill bit. The present study was done to establish the effect of this method. Laboratory model test were carried out to investigate the behavior characteristics with the performance of the pull-out test and failure experiment, after preparing soil test box having 1,300mm length, width 1,000mm, and height 1,100mm, and the same experimental condition was set up to compare with the general soil nailing method(GSNM). The pull-out force of about 23 percentage was increased, and the horizontal displacements 1.2 from 9.1 percentage in soil-nailed wall decreased in EESNM compare with GSNM. The axial force acting on nail increased considerably at load level over 7 ton in EESNM and 5 ton in GSNM. The predicted failure line from the maxima analyzed by axial tensile strain located at long distance from soil-nailed wall in EESNM. The EESNM demonstrated the superiority of reinforcement effect in comparison with GSNM from the results above mentioned.

Effect of Scatter Media on Small Gamma Camera Imaging Characteristics (방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구)

  • Seo, Hyun-Kwan;Choi, Yong;Im, Ki-Chun; Woo, Sang-Geun;Lee, Jun-Soo;Song, Tae-Yong;Choi, Yeon-Sung;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Young-Il
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2002
  • Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(T1) crystal(60$\times$60$\times$6 ㎣), PSPMT(position sensitive photomultimplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness(0~8 cm) and materials(air and acrylic) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10%(air) and 54%(acryl) with the parallel hole collimator and by 35%(air) and 63%(acryl) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera.

  • PDF

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

The Effect of Synchronous CMC Technology by Task Network: A Perspective of Media Synchronicity Theory (개인의 업무 네트워크 특성에 따른 동시적 CMC의 영향 : 매체 동시성 이론 관점)

  • Kim, Min-Soo;Park, Chul-Woo;Yang, Hee-Dong
    • Asia pacific journal of information systems
    • /
    • v.18 no.3
    • /
    • pp.21-43
    • /
    • 2008
  • The task network which is formed of different individuals can be recognized as a social network. Therefore, the way to communicate with people inside or outside the network has considerable influence on their outcome. Moreover, the position on which a member stands in a network shows the different effects of the information systems supporting communication with others. In this paper, it is to be studied how personal CMC (computer-mediated communication) tools affect the mission that those who work for a network perform through diverse task networks. Especially, we focused on synchronicity of CMC. On this score, the perspective of Media Synchronicity Theory was taken that had been suggested by criticizing Media Richness Theory. It is the objective, from this perspective, to find which characteristics of networks make the value of IT supporting synchronicity high. In the research trends of social networks, there have been two traditional perspectives to explain the effect of network: embeddedness and diversity ones. These differ from the aspect which type of social network can provide much more economic benefits. As similar studies have been reported by various researchers, these are also divided into the bonding and bridging views which are based on internal and external tie, respectively, Size, density, and centrality were measured as the characteristics of personal task networks. Size means the level of relationship between members. It is the total number of other colleagues who work with a specific member for a certain project. It means, the larger the size of task network, the more the number of coworkers who interact each other through the job. Density is the ratio of the number of relationships arranged actually to the total number of available ones. In an ego-centered network, it is defined as the ratio of the number of relationship made really to the total number of possible ones between members who are actually involved each other. The higher the level of density, the larger the number of projects on which the members collaborate. Centrality means that his/her position is on the exact center of whole network. There are several methods to measure it. In this research, betweenness centrality was adopted among them. It is measured by the position on which one member stands between others in a network. The determinant to raise its level is the shortest geodesic that represents the shortest distance between members. Centrality also indicates the level of role as a broker among others. To verify the hypotheses, we interviewed and surveyed a group of employees of a nationwide financial organization in which a groupware system is used. They were questioned about two CMC applications: MSN with a higher level of synchronicity and email with a lower one. As a result, the larger the size of his/her own task network, the smaller its density and the higher the level of his/her centrality, the higher the level of the effect using the task network with CMC tools. Above all, this positive effect is verified to be much more produced while using CMC applications with higher-level synchronicity. Among the a variety of situations under which the use of CMC gives more benefits, this research is considered as one of rare cases regarding the characteristics of task network as moderators by focusing ITs for the operation of his/her own task network. It is another contribution of this research to prove empirically that the values of information system depend on the social, or comparative, characteristic of time. Though the same amount of time is shared, the social characteristics of users change its value. In addition, it is significant to examine empirically that the ITs with higher-level synchronicity have the positive effect on productivity. Many businesses are worried about the negative effect of synchronous ITs, for their employees are likely to use them for personal social activities. However. this research can help to dismiss the concern against CMC tools.

Protection effect of metal balls against high energy photon beams (고에너지 광자선에 대한 금속구의 차폐효과)

  • 강위생;강석종
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.137-141
    • /
    • 1998
  • The purposes of this report are to evaluate whether lead ball and steel ball could be used as protective material of radiation and to acquire physical data of them for protecting 4-10 MV X-ray beams. Lead balls of diameter 2.0~2.5mm or steel balls of diameter 1.5~2.0 mm were filled in an acrylic box of uniform width. An MV radiograph of metal balls in a box were taken to ascertain uniformity of ball distribution in the box. Average density of metal ball and linear attenuation coefficient of metal balls for 4~10 MV X -rays were measured. At the time of measurement of linear attenuation coefficient, Farmer ionization chamber was used and to minimize the scatter effect, distance between the ball and the ionization chamber was 70 cm and field size was 5.5cm${\times}$5.5cm. For comparison, same parameters of lead and steel plates were measured. The distribution of metal balls was uniform in the box. The density of a mixture of lead-air was 6.93g/cm$^3$, 0.611 times density of lead, and the density of a mixture of steel-air was 4.75g/cm$^3$, 0.604 times density of steel. Half-value layers of a mixture of lead-air were 1.89 cm for 4 MV X-ray, 2.07 cm for 6 MV X-ray and 2.16 cm for 10 MV X-ray, and approximately 1.64 times of HVL of lead plate. Half-value layers of a mixture of steel-air were 3.24 cm for 4 MV X-ray, 3.70 cm for 6 MV X-ray and 4.15 cm for 10 MV X-ray, and approximately 1.65 times of HVL of lead plate. Metal balls can be used because they could be distributed evenly. Average densities of mixtures of lead-air and steel-air were 6.93g/cm$^3$, 4.75g/cm$^3$ respectively and approximately 1.65 times of densities of lead and steel. Product of density and HVL for a mixture of metal-air are same as the metal.

  • PDF

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

Effects of Planting Data and Planting Density on Growth and Tuber Yield of Yacon in the Middle Region (中部地方에서 Yacon의 定植時期와 裁植密度가 生育 및 收量에 미치는 영향)

  • 송인규
    • Korean Journal of Plant Resources
    • /
    • v.10 no.1
    • /
    • pp.17-23
    • /
    • 1997
  • This experiment was conducted to investigate the effect of planting date and planting density on the growth and yield characters of yacon (Polymnia sonchifolia POEPP) and to establish cultivation method in the middle region of Korea. An introduced variety of yacon was used. Seeding dates were from April 5 to April 7,and seedlings were trasplanted three times on the May 25, june 5, and June 15 with the intervals of 10 days. Planting densities were 80(width) $\times$ 35(distance) cm, 80 $\times$ 45cm, and 80 $\times$ 55cm. Plant height was not significant among planting dates, but was longer in the order of 80 $\times$ 55cm, 80 $\times$ 35cm, and 80 $\times$ 35cm among planting densities. Fresh weight of top part was heavier as the planting dates were faster and planting densities were narrower. Total yeid of tuber had no significant among planting dates and was higher in the density with 80 $\times$ 45cm and had the same tendency in the yeild of commercial goods. Correlation coefficient between plant height and yeild of commercial goods was highly positive(r= 0.927**).

  • PDF

AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF A CALCIUM HYDROXIDE PLUG TREATED WITH DENTIN BONDING AGENT (상아질 결합제로 처리된 수산화칼슘 plug의 근단부 폐쇄능에 관한 연구)

  • Kim, Pyung-Sik;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.187-201
    • /
    • 1996
  • The purpose of this study was to evaluate the sealing ability of a calcium hydroxide plug treated with a bonding agent. Ninety extracted human anterior teeth and premolars with single canal were used in this study. Crowns were removed. the canal's were instrumented. and the roots were randomly divided into three groups of 30 each. In control group. a single apical seat was prepared with #60 K file 1mm short of the apex and the root canal was obturated with Gutta-percha and Sealapex by the lateral condensation method. In experimental group 1 and group 2. to prepare an apical isthmus of 1mm in length. the first apical seat was prepared with a #45 K file 1mm short of the anatomical apex and with a #60 K file 2mm short for the second apical seat. Dry calcium hydroxide powders were packed in the apical isthmus with a hand plugger and #60 K file and then. the root canal was obturated with Gutta-percha and Seal apex by the lateral condensation method. In experimental group 2. following an application of the bonding agent to the plug. the root canal was obturated in the same way. The teeth of each group were immersed in a 2% methylene blue dye solution. for 1, 2, and 4 weeks. The distance from the tip of the cone to the deepest penetration was measured using the Tool maker's microscope. The results were as follows : 1. The teeth having the calcium hydroxide plug treated with the dentin bonding agent (experimental group 2) showed the lowest leakage with 1.4705mm and the control group without apical plug(no apical isthmus) showed the highest leakage with 3.1735mm. 2. The control group without apical plug showed higher leakage than experimental group 1 having the calcium hydroxide plug treated without the dentin bonding agent(p>0.05). 3. The control group without apical plug and experimental group 1, having the calcium hydroxide plug treated without the dentin bonding agent. showed higher leakage than experimental group 2. having the calcium hydroxide plug treated with the dentin bonding agent(p<0.001). 4. The immersion time had no significant effect on the degree of leakage. In conclusion, the results showed that the calcium hydroxide plug treated with the dentin bonding agent could decrease the microleakage from the root apex effectively.

  • PDF