• Title/Summary/Keyword: sag

Search Result 702, Processing Time 0.026 seconds

Synchronous PI control scheme for DVR against a voltage sag in the power system (전력 계통내에서 순간 전압 강하에 빠른 응답 특성을 가진 DVR의 제어)

  • Kim M.B.;Lee S.H.;Moon G.W.;Youn M.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.554-559
    • /
    • 2003
  • A new control strategy for dynamic voltage restorer (DVR) is proposed. It is based on synchronous PI control strategy which features fast response. Therefore, the proposed control strategy takes faster action against a voltage sag. Experimental results, executed by DSP, are shown to validate the proposed control strategy.

  • PDF

A New Control Algorithm for Instantaneous Voltage Sag Corrector (순시전압강하 보상기의 새로운 제어 기법)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

Analysis of Geometric Shape and Displacement in Coastal Structure (해안 구조물의 기하형상과 변위 해석)

  • Mun, Do-Yeoul;Baek, Tae-Kyung;Lee, Tack-Gon;Lee, Sung-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.114-123
    • /
    • 2012
  • This study is aimed to assess the stability of cable bridge by determining the geometric shape of the suspension bridge among the domestic coastal structures in public use after their completion of construction and the displacement of the target suspension bridge after public use. For this purpose, this study calculated the length between pylon piers for each period, sag, sag ratio and the displacement of pylon. Compared to the management standards for each step across different pylon behaviors of the target suspension bridge, this study found that the target suspension bridge behaves stably within the maintenance standards. To identify the behaviors of a suspension bridge accurately, the priority is put on the determination of geometric shape. Therefore, it is required to determine the surveyed shape model on a regular basis across public use period and increased traffics, which is expected to contribute considerably to ensuring the stability of the suspension bridge in its maintenance.

Prediction of Firmness and Strength of Low-ester Pectin Gel from Chemical Composition (Low-ester Pectin Gel의 단단함과 강도(强度)의 예측)

  • Kim, Woo-Jung;Smit, C.J.B.;Rao, V.N.M.
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.364-371
    • /
    • 1986
  • High-ester pectin was demethylated by the treatments of HCl alone and a combination of HCl and $NH_4OH$. The low-ester pectin prepared were analyzed for chemical composition and the pectin gels were evaluated for firmness by sag values and strength by puncture stress. Gels made from HCl demethylated sample showed brittle, weak and poor elastic characteristics while the $HCl-NH_4OH$ treated samples generally resulted in a smooth and elastic gels except those samples having very low content of ester group or acid amide group. Statistical analysis showed that significant correlations were found between sag values and ester content or molecular weight, and puncture stress and ester content, acid amide groups or molecular weight. The equations derived for sag, puncture stress and sag/puncture stress from chemical data could be useful for prediction of some of the physical properties of low-ester pectin gel.

  • PDF

Aeroelastic Behaviors of Self-anchored Suspension Bridge with Lateral Sag of Main Cable(I) -Focused on the Behavior of Girder- (횡방향 새그를 가진 자정식 현수교의 공탄성 거동(I) -주형의 거동을 중심으로-)

  • Kwon, Soon Duck;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.259-267
    • /
    • 1997
  • Wind tunnel test results and their interpretations focused on the behavior of girder, which were performed to study the aerodynamic stability of a self-anchored suspension bridge with lateral sag of main cable, are presented in this paper The shape of the girder which has the best aerodynamic stability was selected based on the section model test under uniform and turbulent flow conditions. Good performance of the selected section was confirmed in the full bridge model test. Measured flutter derivatives are presented for further study. Buffeting response was investigated to check the fatigue problem and serviceability of the bridge but it was found to be acceptable from the engineering point of view. Even though the drag coefficient of the girder had high value, the amplitude of the lateral vibration was found to be very low. This may be due to the restraint provided by the lateral sag of the cables.

  • PDF

Power Quality Measurement for LED-based Green Energy Lighting Systems (LED 기반 그린에너지 조명시스템을 위한 전력품질 측정)

  • Yu, Hyung-Mo;Choi, Jin-Won;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.174-184
    • /
    • 2013
  • For the successful R&D and deployment of LED-based green energy lighting systems, the real-time power quality measurement of both various non-linear power signals including pulse waveform, spike waveform, etc and the undesired-signals including harmonics, sag, swell, etc is required. In this paper, we propose a low-cost power quality measurement (PQM) method for low- (60Hz-several KHz) to high-frequency (several tens KHz) power signals, which are generated by green-energy lighting systems, and implement a PQM testbed using TI TMS320F28335 MCU. The proposed algorithm is programmed using C in the CCS (Code Composer Studio) 3.3 environment and is verified using test signals generated by an arbitrary signal generator, NF-WF1974. In the implemented testbed, we can measure various non-linear current signals that LED SMPS generates, analyze harmonics by fast Fourier transform, and test sag, swell, and interruption using wavelet transform.

Analysis of Control Algorithm for Instantaneous Voltage Sag Corrector (순시적인 전압 sag 보상기에 대한 제어 알고리즘의 해석)

  • 이상훈;김재식;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.173-179
    • /
    • 2001
  • This paper represents the control algorithm of the instantaneous voltage sag corrector for the power quality enhancement in distribution line. Especially, a novel detection technique of the symmetrical components is proposed for the analysis of the three-phase unbalanced and asymmetrical problems caused by the single line ground fault which is he most frequent event. This proposed method is based on the simple calculation and the control references of the symmetrical components for voltage compensation can be described as dc value without any other phase detection procedure. And also, for the generation of the reference voltages, the UF and MF defined by IEC is considered. Using this proposed control algorithm, the compensator has the fast dynamic characteristics and the THD of the compensated voltage waveform is very low. Finally, the validity of the proposed algorithm is proved by the PSCAD/EMTDC simulation and experimental results.

  • PDF

Effect of Change in Water Content and NCO Index on the Static Comfort of Polyurethane Seat Foam Pad for Automobiles (물 함량과 NCO Index 변화가 자동차용 폴리우레탄 시트 폼 패드의 정적 안락감에 미치는 영향 고찰)

  • Lee, Byoung Jun;Lee, Sung Hoon;Choi, Kwon Yong;Kim, Sang-bum
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • In this study, we identified how the water content change in various NCO index affects the static comfort of polyurethane seat foam pad for automobiles. In order to identify factors that affect the static comfort, a static load test was performed using UTM to plot a hysteresis curve. The hardness of the foam when it was modified by 25, 65%, hysteresis loop area, hysteresis loss (%), and Sag factor were also obtained. By measuring the swelling ratio, it was confirmed that, as the water content increased in a fixed NCO index, the hardness and crosslinking density increased while the restoring force decreased due to the increase of urea bond. Also the Sag factor decreased due to the increase of surface hardness. As the NCO index increased in a fixed water content, the urethane and urea bond reacted more with isocyanate, leading to an increase in hardness and decrease in restoring force.

A study on analysis of DVR(Dynamic Voltage Restorer) in electric traction network by using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전기철도급전계통에 DVR(Dynamic Voltage Restorer)해석에 관한 연구)

  • Choi, J.H.;Kim, J.C.;Park, S.M.;Kim, T.S.;Choo, D.W.;Chung, I.Y.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.283-286
    • /
    • 2003
  • The electric traction load is quite differ from general power system load which is single-phase, high-speed heavy load receiving power from 3-phase power system and also has variable load characteristics over time and space. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. In addition, it is expected that transient voltage sag could affect the safety of feeding system. Thus, in this paper transient analysis and voltage sag compensation of AT(Auto Transformer) feeding system are studied. The fault study of traction network is analysed by using PSCAD/SMTDC simulation tool. In addition, application of DVR in electric traction system is proposed to compensate the voltage sag of traction network which is occurred by the fault of utility source. The results of fault study will be a useful research works for operation and setting of electric traction relay. Also, it can be shown that application of the DVR in electric system is very useful to compensate the voltage sag from the result of related simulated work. The results of study will be a useful research works for management and planning of power quality in electric traction system.

  • PDF

Effect of Anterior Guidance Change on the Condylar Path in Skeletal Class I Young Adult Women Using a Splint with Flat or Steep Anterior Guidance

  • Choi, Byung-Taek;Baek, Seung-Hak
    • Journal of Korean Dental Science
    • /
    • v.5 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • Purpose: To investigate the effects of anterior guidance (AG) change on the working (WCP) and non-working condylar paths (NWCP), and lower incisor path (LIP) using a splint with flat (FAG) or steep AG (SAG). Materials and Methods: The samples consisted of six young adult women (mean age=$23.5{\pm}3.3$ years). Inclusion criteria were skeletal Class I and normodivergent pattern, normal overbite/overjet, minimal slide from retruded cuspal position to intercuspal position, no temporomandibular disorder signs and symptoms, mutually protected occlusion, and minimal tooth wear. After the values of natural AG (NAG) were obtained as a reference for each patient, two types of splints ($15^{\circ}$ flatter and steeper than NAG) were made. After insertion of the splints with FAG or SAG, the WCP, NWCP, and LIP were recorded five times for each patient using an ultrasonic AQR (SAM, Munich, Germany) and statistical analysis was subsequently performed. Result: NAG exhibited postero-superior movement in the WCP and did not show a noticeable immediate side shift (ISS) or difference between the eccentric (EP) and returning paths (RP) in the NWCP. FAG was associated with an irregular and excessive WCP, an increase in ISS, and a difference between EP and RP in the NWCP. SAG showed minimal WCP movement and a decrease in the extent of difference between EP and RP in the NWCP. LIP showed significant differences in EP and in RP (P<0.001, all; FAG