• 제목/요약/키워드: sag

검색결과 706건 처리시간 0.025초

전압품질이 저압 전기기기 운전에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.33-35
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

Toxoplasma gondii virulence prediction using hierarchical cluster analysis based on coding sequences (CDS) of sag1, gra7 and rop18

  • Subekti, Didik T;Ekawasti, Fitrine;Desem, Muhammad Ibrahim;Azmi, Zul
    • Journal of Veterinary Science
    • /
    • 제22권6호
    • /
    • pp.88.1-88.6
    • /
    • 2021
  • Toxoplasma gondii consists of three genotypes, namely genotype I, II and III. Based on its virulence, T. gondii can be divided into virulent and avirulent strains. This study intends to evaluate an alternative method for predicting T. gondii virulence using hierarchical cluster analysis based on complete coding sequences (CDS) of sag1, gra7 and rop18 genes. Dendrogram was constructed using UPGMA with a Kimura 80 nucleotide distance measurement. The results showed that the prediction errors of T. gondii virulence using sag1, gra7 and rop18 were 7.41%, 6.89% and 9.1%, respectively. Analysis based on CDS of gra7 and rop18 was able to differentiate avirulent strains into genotypes II and III, whereas sag1 failed to differentiate.

Cable sag-span ratio effect on the behavior of saddle membrane roofs under wind load

  • Hesham Zieneldin;Mohammed Heweity;Mohammed Abdelnabi;Ehab Hendy
    • Wind and Structures
    • /
    • 제36권3호
    • /
    • pp.149-160
    • /
    • 2023
  • Lightness and flexibility of membrane roofs make them very sensitive to any external load. One of the most important parameters that controls their behavior, especially under wind load is the sag/span ratio of edge cables. Based on the value of the pretension force in the edge cables and the horizontal projection of the actual area covered by the membrane, an optimized design range of cable sag/span ratios has been determined through carrying on several membrane form-finding analyses. Fully coupled fluid structure dynamic analyses of these membrane roofs are performed under wind load with several conditions using the CFD method. Through investigating the numerical results of these analyses, the behavior of membrane roofs with cables sag/span ratios selected from the previously determined optimized design range has been evaluated.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

A Rapid Diagnostic Test for Toxoplasmosis using Recombinant Antigenic N-terminal Half of SAG1 Linked with Intrinsically Unstructured Domain of GRA2 Protein

  • Song, Kyoung Ju;Yang, Zhaoshou;Chong, Chom-Kyu;Kim, Jin-Soo;Lee, Kyung Chan;Kim, Tong-Soo;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • 제51권5호
    • /
    • pp.503-510
    • /
    • 2013
  • Toxoplasma gondii is an apicomplexan parasite with a broad host range of most warm-blooded mammals including humans, of which one-thirds of the human population has been infected worldwide which can cause congenital defects, abortion, and neonatal complications. Here, we developed a rapid diagnostic test (RDT) for T. gondii infection. Antigenic N-terminal half of the major surface antigen (SAG1) was linked with intrinsically unstructured domain (IUD) of dense granule protein 2 (GRA2). The recombinant GST-GRA2-SAG1A protein was successfully expressed and purified as 51 kDa of molecular weight. Furthermore, antigenicity and solubility of the rGST-GRA2-SAG1A protein were significantly increased. The overall specificity and sensitivity of GST-GRA2-SAG1A loaded RDT (TgRDT) were estimated as 100% and 97.1% by comparing with ELISA result which uses T. gondii whole cell lysates as the antigen. The TgRDT tested with Uganda people sera for field trial and showed 31.9% of seroprevalence against T. gondii antibody. The TgRDT is proved to be a kit for rapid and easy to use with high accuracy, which would be a suitable serodiagnostic tool for toxoplasmosis.

Providing Efficient Secured Mobile IPv6 by SAG and Robust Header Compression

  • Wu, Tin-Yu;Chao, Han-Chieh;Lo, Chi-Hsiang
    • Journal of Information Processing Systems
    • /
    • 제5권3호
    • /
    • pp.117-130
    • /
    • 2009
  • By providing ubiquitous Internet connectivity, wireless networks offer more convenient ways for users to surf the Internet. However, wireless networks encounter more technological challenges than wired networks, such as bandwidth, security problems, and handoff latency. Thus, this paper proposes new technologies to solve these problems. First, a Security Access Gateway (SAG) is proposed to solve the security issue. Originally, mobile terminals were unable to process high security calculations because of their low calculating power. SAG not only offers high calculating power to encrypt the encryption demand of SAG's domain, but also helps mobile terminals to establish a multiple safety tunnel to maintain a secure domain. Second, Robust Header Compression (RoHC) technology is adopted to increase the utilization of bandwidth. Instead of Access Point (AP), Access Gateway (AG) is used to deal with the packet header compression and de-compression from the wireless end. AG's high calculating power is able to reduce the load on AP. In the original architecture, AP has to deal with a large number of demands by header compression/de-compression from mobile terminals. Eventually, wireless networks must offer users "Mobility" and "Roaming". For wireless networks to achieve "Mobility" and "Roaming," we can use Mobile IPv6 (MIPv6) technology. Nevertheless, such technology might cause latency. Furthermore, how the security tunnel and header compression established before the handoff can be used by mobile terminals handoff will be another great challenge. Thus, this paper proposes to solve the problem by using Early Binding Updates (EBU) and Security Access Gateway (SAG) to offer a complete mechanism with low latency, low handoff mechanism calculation, and high security.

Design formulas for vibration control of sagged cables using passive MR dampers

  • Duan, Yuanfeng;Ni, Yi-Qing;Zhang, Hongmei;Spencer, Billie F. Jr.;Ko, Jan-Ming;Dong, Shenghao
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.537-551
    • /
    • 2019
  • In this paper, a method for analyzing the damping performance of stay cables incorporating magnetorheological (MR) dampers in the passive control mode is developed taking into account the cable sag and inclination, the damper coefficient, stiffness and mass, and the stiffness of damper support. Both numerical and asymptotic solutions are obtained from complex modal analysis. With the asymptotic solution, analytical formulas that evaluate the equivalent damping ratio of the sagged cable-damper system in consideration of all the above parameters are derived. The main thrust of the present study is to develop an general design formula and a universal curve for the optimal design of MR dampers for adjustable passive control of sagged cables. Two sag-affecting coefficients are derived to reflect the effects of cable sag on the maximum attainable damping ratio and the optimal damper coefficient. For the cable configurations commonly used in cable-stayed bridges, the sag-affecting coefficients are directly expressed in terms of the sag-extensibility parameter to facilitate the control design. A case study on adjustable passive vibration control of the longest cable (536 m) on Stonecutters Bridge is carried out to demonstrate the influence of the sag for the damper design, and to figure out the necessity of adjustability of damper coefficients for achieving maximum damping ratio for different vibration modes.

Small Molecule-Based Strategy Promotes Nucleus Pulposus Specific Differentiation of Adipose-Derived Mesenchymal Stem Cells

  • Hua, Jianming;Shen, Ning;Wang, Jingkai;Tao, Yiqing;Li, Fangcai;Chen, Qixin;Zhou, Xiaopeng
    • Molecules and Cells
    • /
    • 제42권9호
    • /
    • pp.661-671
    • /
    • 2019
  • Adipose tissue-derived mesenchymal stem cells (ADSCs) are promising for regenerating degenerated intervertebral discs (IVDs), but the low efficiency of nucleus pulposus (NP)-specific differentiation limits their clinical applications. The Sonic hedgehog (Shh) signaling pathway is important in NP-specific differentiation of ADSCs, and Smoothened Agonist (SAG) is a highly specific and effective agonist of Shh signaling. In this study, we proposed a new differentiation strategy with the use of the small molecule SAG. The NP-specific differentiation and extracellular matrix (ECM) synthesis of ADSCs were measured in vitro, and the regenerative effects of SAG pretreated ADSCs in degenerated IVDs were verified in vivo. The results showed that the combination of SAG and transforming growth factor-${\beta}3$ ($TGF-{\beta}3$) is able to increase the ECM synthesis of ADSCs. In addition, the gene and protein expression levels of NP-specific markers were increased by treatment with SAG and $TGF-{\beta}3$. Furthermore, SAG pretreated ADSCs can also improve the disc height, water content, ECM content, and structure of degenerated IVDs in vivo. Our new differentiation scheme has high efficiency in inducing NP-specific differentiation of ADSCs and is promising for stem cell-based treatment of degenerated IVDs.

요추 MR영상에 포함된 경흉추 시상T2강조영상의 효용성 평가 (The Value of Additional Cervicothoracic Spine Sagittal T2-weighted Images Included in Routine Lumbar Spine MR Imaging)

  • 서지운;박소영;이준우;이근영;강흥식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.91-100
    • /
    • 2013
  • 목적: 요추 MR 영상에 추가된 경흉추 시상T2강조영상(CT SAG T2WI)의 임상적 효용성을 평가하고자 한다. 대상과 방법: 2005년 1월부터 2005년 12월까지 요추 MRI를 시행하였던 2,113명의 환자를 대상으로 하였다. 경흉추 시상T2강조영상을 후향적으로 분석하였고, 의무기록을 후향적으로 검토하여 경추 또는 흉추 병변의 추가적인 평가를 위한 MRI 또는 CT 시행여부와 이러한 병변에 대한 치료 및 경과를 알아보았다. 결과: 2,113명중 139명의 환자에게서 총 142개의 병변이 경흉추 시상T2강조영상에서 관찰되었다. 요추 MRI 촬영시, 환자의 자세변화 없이 2분 이내에 경흉추 시상T2강조영상을 추가적으로 얻었다. 13명의 환자만이 경추 또는 흉추의 병변에 대해 MR영상 또는 CT를 시행하였고, 7명의 환자는 T2강조영상 고신호강도 여부에 상관 없이 척추관협착증 또는 추간판탈출증에 대해 수술적 치료를 받았다. 결론: 요추 MRI촬영 시, 2분 이내로 소요되는 경흉추 시상T2강조영상의 추가촬영은 요추의 증상으로 오인된 경흉추의 병변을 평가하는데 유용하다.

대두 Arabinogalactan으로부터 갈락토올리고당의 생산과 그 특성에 관한 연구 (Study on Production and Properties of Galactooligosaccharide from Soybean Arabinogalactan)

  • 신해헌;최형택;최동원
    • 한국식품영양학회지
    • /
    • 제10권4호
    • /
    • pp.497-502
    • /
    • 1997
  • 대두 및 두유박의 주요 다당류인 대두 arabinogalactan(SAG)을 이용하여 갈락토올리고당을 생산하고자 SAG 가수분해효소인 $\beta$-1, 4-galactanase를 이용하여 대두 갈락토올리고당(SOS)의 생산조건 및 그 특성을 연구 검토하였다. SOS는 SAG 1%(w/v), pH 8.0, 5$0^{\circ}C$인 조거에서 $\beta$-1, 4-galactanase를 20unit/g SAG를 첨가하여 24-40시간 반응하여 생산하였다. 생산된 SOS 용액(75%)은 11,000cp의 점도를 나타내어 같은 농도의 설탕용액 140cp의 값에 비해 80배 큰 값을 나타내었다. 점도의 온도의존성은 5$0^{\circ}C$ 이하에서는 온도의존 함수(B) 값이 11,037 cp.K로 설탕용액의 2,760보다 약 4.6배 크지만 5$0^{\circ}C$ 이상에서는 3,400으로 큰 차이를 보이지 않았다. 또한 올리고당의 농도가 50 Brix 이하에서는 설탕용액의 점도 20-30 cp와 유사한 20-40cp로 차이를 보이지 않지만 농도가 증가함에 따라 차이가 커져 Brix 70에서는 1,280cp로 설탕용액의 90cp보다 15배 높은 값을 나타내었다. 생산된 SOS는 pH 및 온도에 대해 매우 안정하여 pH 3,14$0^{\circ}C$인 조건하에서도 분해로 인하여 생산되는 galactose가 없었다.

  • PDF