• Title/Summary/Keyword: safety-critical

Search Result 2,175, Processing Time 0.029 seconds

Monte Carlo Simulation of Irradiation Treatment of Peaches (Prunus persica L. Batsch) (몬테카를로 시뮬레이션을 이용한 복숭아의 방사선 조사)

  • Kim, Jongsoon;Kim, Dong-Hyun;Park, Jong-Min;Choi, Won-Sik;Kwon, Soon Hong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.337-344
    • /
    • 2018
  • Food irradiation is important not only in ensuring safety but also improving antioxidant activity of peaches. Our objective was to establish the best irradiation treatment for peaches by calculating dose distribution using Monte Carlo simulation. 3-D geometry and component densities of peaches, extracted from CT scan, were entered into MCNP to obtain simulated dose distribution. Radiation energies for electron beam were 1.35 MeV (low energy) and 10 MeV (high energy). Co (1.25 MeV) and the Husman irradiator, containing three sealed Cs source rods in an annular array, were used for gamma irradiation. At 1.35 MeV electron beam simulation, electrons penetrated well beyond the peach skin, enough for surface treatment for microorganisms and allergens. At 10 MeV electron beam simulation, for top-beam only treatment, doses at the core were the highest and for double beam treatment, the electron energy was absorbed by the entire sample. At Co source, the radiation doses were presented on the whole area. At Cs source, the dose uniformity ratios were 2.78 for one source and 1.48 for three ones at 120 degrees interval. Proper control of irradiation treatment is critical to establish confidence in the irradiation process.

Development of Mechanical Construction Method of Road Deck Middle Slab of Double Deck Tunnel in Great Depth (대심도 복층터널 중간슬래브의 기계화 시공법 개발)

  • Lee, Doo Sung;Kim, Young Jin;Kim, Tae Kyun;Kim, Chang Yeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.451-460
    • /
    • 2019
  • It is critical for Korea to make effective use of limited space as it has dense population and high traffic volume compared to its terrestrial area. To resolve this issue, diverse types of underground structures have increasingly been applied so far, and one of the most representative structures is double-deck tunnel. The construction period of the middle slab in the double deck tunnel constructed at the great depth can be considered as an important part after the tunnel lining construction in the whole process. In order to minimize the construction period required for construction of the middle slab in the double deck tunnel, it was proposed a method of the precast intermediate slab. In this study, it is suggested a mechanical construction process with dedicated equipments developed to improve the safety and the workability of erection of the precast middle slab than the current construction method using the existing mobile crane.

Treatment of Mycobacterium avium Complex Pulmonary Disease

  • Kwon, Yong-Soo;Koh, Won-Jung;Daley, Charles L.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.1
    • /
    • pp.15-26
    • /
    • 2019
  • The pathogen Mycobacterium avium complex (MAC) is the most common cause of nontuberculous mycobacterial pulmonary disease worldwide. The decision to initiate long-term antibiotic treatment is difficult for the physician due to inconsistent disease progression and adverse effects associated with the antibiotic treatment. The prognostic factors for the progression of MAC pulmonary disease are low body mass index, poor nutritional status, presence of cavitary lesion(s), extensive disease, and a positive acid-fast bacilli smear. A regimen consisting of macrolides (clarithromycin or azithromycin) with rifampin and ethambutol has been recommended; this regimen significantly improves the treatment of MAC pulmonary disease and should be maintained for at least 12 months after negative sputum culture conversion. However, the rates of default and disease recurrence after treatment completion are still high. Moreover, treatment failure or macrolide resistance can occur, although in some refractory cases, surgical lung resection can improve treatment outcomes. However, surgical resection should be carefully performed in a well-equipped center and be based on a rigorous risk-benefit analysis in a multidisciplinary setting. New therapies, including clofazimine, inhaled amikacin, and bedaquiline, have shown promising results for the treatment of MAC pulmonary disease, especially in patients with treatment failure or macrolide-resistant MAC pulmonary disease. However, further evidence of the efficacy and safety of these new treatment regimens is needed. Also, a new consensus is needed for treatment outcome definitions as widespread use of these definitions could increase the quality of evidence for the treatment of MAC pulmonary disease.

Development of smart HACCP effectiveness analysis model (스마트 HACCP 효과 분석 모델 개발)

  • Lee, Han-Cheol;Kang, Ju-Yeong;Park, Eun-Ji;Park, Min-Ji;Oh, Do-Gyung;Kim, Chan-Yeong;Jeong, Eun-Sun;Kim, Jai-Moung;Ahn, Yeong-Soon;Kim, Jung-Beom
    • Food Science and Industry
    • /
    • v.54 no.3
    • /
    • pp.184-195
    • /
    • 2021
  • Smart HACCP is a system that can check the monitoring of critical control point (CCP) in real time to implement improvement measures immediately after departure from limit criteria and prevent falsification of data by digitizing handwritten records. In this study, we developed the analysis model for the effectiveness ofsmart HACCP to compare and analyze with existing HACCP. By introducing of smart HACCP system, the evaluation index value of HACCP effectiveness for HACCP-certificated companies on a small scale increased by 9.25 points, corresponding to 11.52% of increase rate. General HACCP-certificated companies showed 4.52 point and 5.00% of increase rate by introducing of smart HACCP system. Thus, it was confirmed that the introduction of smart HACCP system contributes to the improvement of food safety management and especially it would be more effective for HACCP-certificated companies on a small scale than general HACCP-certificated companies.

Automated detection of corrosion in used nuclear fuel dry storage canisters using residual neural networks

  • Papamarkou, Theodore;Guy, Hayley;Kroencke, Bryce;Miller, Jordan;Robinette, Preston;Schultz, Daniel;Hinkle, Jacob;Pullum, Laura;Schuman, Catherine;Renshaw, Jeremy;Chatzidakis, Stylianos
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.657-665
    • /
    • 2021
  • Nondestructive evaluation methods play an important role in ensuring component integrity and safety in many industries. Operator fatigue can play a critical role in the reliability of such methods. This is important for inspecting high value assets or assets with a high consequence of failure, such as aerospace and nuclear components. Recent advances in convolution neural networks can support and automate these inspection efforts. This paper proposes using residual neural networks (ResNets) for real-time detection of corrosion, including iron oxide discoloration, pitting and stress corrosion cracking, in dry storage stainless steel canisters housing used nuclear fuel. The proposed approach crops nuclear canister images into smaller tiles, trains a ResNet on these tiles, and classifies images as corroded or intact using the per-image count of tiles predicted as corroded by the ResNet. The results demonstrate that such a deep learning approach allows to detect the locus of corrosion via smaller tiles, and at the same time to infer with high accuracy whether an image comes from a corroded canister. Thereby, the proposed approach holds promise to automate and speed up nuclear fuel canister inspections, to minimize inspection costs, and to partially replace human-conducted onsite inspections, thus reducing radiation doses to personnel.

Relationship between the Series named OTC Products and Pharmacist's Professional Workloads in Community Pharmacy (지역약사의 시리즈형 OTC 약물에 대한 약사의 직능 수행에 대한 평가)

  • Kim, Jeong Eun;Lim, Sung Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.30 no.4
    • /
    • pp.226-233
    • /
    • 2020
  • Background: Currently, the over-the-counter (OTC) drug market is flooded with series OTC products. The pharmacist must follow the OTC product's indication, given that the most critical role of a pharmacist is the right selection and recommendation of an OTC drug for a patient's symptoms in a dynamic pharmacy environment. Therefore, pharmacists must know each OTC product information precisely to avoid any ambiguity due to several OTC series brand names. Objective: We evaluated the risk and effectiveness of OTC series medicines. Methods: From December 5 to December 18, 2019, an online survey was conducted among 145 community pharmacists. Results: A total of 51.0% of pharmacists knew the difference between products named in a series and could explain it spontaneously. Only 0.7% of the pharmacists admitted to not knowing the difference between products named in a series. While 42.9% of pharmacists who owned a pharmacy opined that the OTC medicines named in a series have health benefits for patients, 50.0% of employee pharmacists admitted that they were rather confused because there are several OTC series medicines. In contrast, 69.2% of pharmacists who owned pharmacies and 72.2% of employee pharmacists admitted that OTC series drugs with names similar to popular OTC drugs sell better. Conclusion: While pharmacists had different opinions regarding OTC series drugs per employment status, they opined that OTC series are more helpful in pharmacy management than completely new brand names. Further studies in this regard are needed.

The Monitoring System of Temperature and Humidity on Vehicle for HACCP (HACCP을 위한 차량용 온습도 모니터링 시스템)

  • Kim, Joon-bae;Kang, Moon-sung
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.168-172
    • /
    • 2018
  • HACCP is scientific Sanitary control system to ensure food safety with autonomous, systematic and effective way by analysing hazard element that can be occurred in each steps until an end consumer takes food including raw material status, manufacturing, processing, storing, distributing, cooking and specifying the critical control point. In this paper, the temperature and humidity are measured during the transport of food, the stage of its distribution, to ensure systematic and effective management of HACCP, and we designed a monitoring terminal that uses this information to send it to servers periodically and a firmware that implements it. We have confirmed that the data transmitted by the terminal, including the information measured in sub-net, was well stored on the server and the response from the server is well received by the terminal. It is expected to be used for the management of food history, data tracking and statistical data in the future. This system is also considered to be an applicable system for group cafeteria such as schools or workplaces and logistics warehouses for raw materials or food storage and so on.

The development of nurses' core competencies and the analysis of validity and importance-performance (간호사 핵심역량 개발 및 타당도와 중요도 대비 수행도 분석)

  • Seomun, GyeongAe;Bang, Kyung-Sook;Kim, Hee Sook;Yoo, Cheong Sook;Kim, Woon Kyung;Park, Jin Kyung
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.27 no.1
    • /
    • pp.16-28
    • /
    • 2021
  • Purpose: The purpose of this study was to develop nurses' core competencies and sub-competencies and to verify the validity and importance-performance of core competencies. Methods: The core competencies of nurses were derived through an analysis of strengths, weaknesses, opportunities, and threats, as well as a literature analysis of domestic and foreign accreditation institutions. Validity and importance-performance analyses were conducted on the core competencies derived from nursing colleges nationwide. Results: Six core competencies of nurses were revealed: integration of knowledge and nursing skills, critical thinking, communication, leadership, safety management, and global competency. Further, eighteen sub-competencies were derived. The content validity ratio values for the core competencies were higher than 0.74. Communication skills among multidisciplinary teams and communication skills among nursing teams were shown to be the most important competencies to be improved. Conclusion: The results of this study are meaningful in terms of how the core competencies of nurses were derived and evaluated for the fourth cycle of nursing education accreditation according to the changes of time and culture.

MuGenFBD: Automated Mutant Generator for Function Block Diagram Programs (MuGenFBD: 기능 블록 다이어그램 프로그램에 대한 자동 뮤턴트 생성기)

  • Liu, Lingjun;Jee, Eunkyoung;Bae, Doo-Hwan
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.4
    • /
    • pp.115-124
    • /
    • 2021
  • Since function block diagram (FBD) programs are widely used to implement safety-critical systems, effective testing for FBD programs has become important. Mutation testing, a fault-based testing, is highly effective in fault detection but computationally expensive. To support testers for FBD programs, we propose an automated mutant generator for FBD programs. We designed the MuGenFBD tool with the cost and equivalent mutant issues in consideration. We conducted experiments on real industrial examples to present the performance of MuGenFBD. The results show that MuGenFBD can generate mutants for FBD programs automatically with low probability of equivalent mutants and low cost. This tool can effectively support mutation analysis and mutation-adequate test generation for FBD programs.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.