• 제목/요약/키워드: safety inspection criteria

검색결과 131건 처리시간 0.021초

QC담당자의 인식 및 실행이 사후관리에 미치는 영향에 관한 연구: KS인증 공장심사 평가항목을 중심으로 (A Study on the Effect of Perception and Practice of QC Personnel on Post-Management: Focusing on KS Certified Factory Evaluation Criteria)

  • 유연택;홍정의;김광수
    • 대한안전경영과학회지
    • /
    • 제26권2호
    • /
    • pp.107-115
    • /
    • 2024
  • This study conducted frequency analysis, reliability analysis, descriptive statistics, and correlation analysis to determine the impact of quality control managers' perception and implementation of KS certification factory inspection evaluation items on follow-up management. Through a multiple linear regression model, the influence of KS certification officer's awareness and implementation of KS certification factory inspection on post management was found to have a positive (+) influence on post management, with implementation having a greater influence on post management than awareness. It was having an impact. The independent variable (perception) has a statistically significant impact on the mediating variable (execution), and in the stage of verifying the mediating effect, the influence of the independent variable (perception) on the dependent variable (follow-up management) has a statistically significant impact. , In the stage where the independent variable (perception) and the mediator (implementation) are input simultaneously, both the independent variable and the mediator have a statistically significant effect on the dependent variable, indicating that there is a mediation effect.

낙하시험에 의한 폴리에틸렌 보트의 구조 안전성 평가 (Evaluation of Structural Safety of Polyethylene Boats by Drop Test Method)

  • 이성룡;강경주;조석수
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.531-542
    • /
    • 2017
  • 강선이나 강화플라스틱선 등의 선박 재료는 선박안전법에 규정된 규격재료를 사용하는 경우로서 판두께 측정시험이나 종굽힘강도시험을 통하여 제작 선체의 구조 안전성을 쉽게 확인할 수 있다. 한편, 염가의 폴리에틸렌 등과 같은 비규격재료를 선체 전장이 짧은 플레저 보트의 선체로 사용하는 경우 역학적 특성을 파악하기 쉬워 선체 설계를 수행하기에 매우 유리하고, 대량 생산 시스템을 갖추는 경우 제작 비용이 낮아 해당 제품의 가격 경쟁력을 가질 수 있다. 그러나 폴리에틸렌 선체의 경우 비규격재료를 사용함에 따라 기존의 소형선체에 대한 종굽힘강도시험을 이용하여 선체의 구조 안전성을 평가할 수 없다. 이러한 문제점을 해결하기 위하여 본 연구에서는 플레저 보트의 낙하시험 표준절차인 플레저 보트 검사 기준과 ISO 12215-5를 기초로 폴리에틸렌 선체에 대한 낙하시험을 수행한 후 이것을 기초로 정적구조해석을 수행하여 비규격재료로 개발된 선체의 구조 안전성을 확인함으로서 플레저 보트 검사 기준과 ISO 12215-5의 낙하시험방법이 선체 구조설계에 이용될 수 있음을 보였다.

조적조 건축물의 균열양태 및 등급판정과의 상관성에 관한 연구 (An Analysis on the Correlation between Crack Condition and Safety Grades in Masonry Buildings)

  • 권기혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.101-110
    • /
    • 2005
  • 서울지역에, 건축물의 열화는 1960년 이전에 지어진 조적조 건축물에 영향이 크다. 그러나 대부분이 유지관리가 되지 않고 있다, 결과적으로, 열화율은 더 빨리 진행되며, 근접 건축물과 이웃에게 위험한 상황을 야기 시킬지 모른다. 이 연구의 목적은 조적조 건축물에 발생한 결함 형태 중 벽체균열의 진행 상태를 연구하고, 건축물의 안전 등급을 제정하기 위한 기초 자료로 제안하기 위해 안전등급과의 상호관계를 분석하여, 개선하고자 함이다. 결과로서는 안전등급과 균열 폭의 높은 상관성을 나타나지만, 균열길이와는 다소 낮게 나타난다. 균열패턴에서는 수직균열이 안전등급에 더 많은 영향을 주는 것으로 분석되었다.

증기발생기 전열관 확관천이부위 축방향 관통균열의 관막음 기준에 관한 연구 (Study on Plugging Criteria for Thru-wall Axial Crack in Roll Transition Zone of Steam Generator Tube)

  • 박명규;김영종;전장환;김종민;박준수
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2894-2900
    • /
    • 1996
  • The stream generator tubes represent an integral part of a major barrier against the fission product release to the environment. So, the rupture of these tubes could permit flow of reactor coolant into the secondary system and injure the safety of reactor coolant system. Therefore, if the crack was detected during In-Service Inspection of tubes the cracked tube should be evaluated by the pulgging criteria and plugged or not. In this study, the fracture mechanics evaluation is carried out on the thru-wall axial crack due to Primary Water Stress Corrosion Cracking in the roll transition aone of steam generator tube to help the assurence the integrity of tubes and estabilish the plugging criteria. Due to the Inconel which is used as tube material is more ductile than others, the plastic instability repture theory was used to calculate the critical and allowable crack length. Based on Leak Before Break concept the leak rate for the critical crack length and the allowable leak rate are compared and the safety of tubes was given.

Hydraulic and Structural Analysis for APR1400 Reactor Vessel Internals against Hydraulic Load Induced by Turbulence

  • Kim, Kyu Hyung;Ko, Do Young;Kim, Tae Soon
    • International Journal of Safety
    • /
    • 제10권2호
    • /
    • pp.1-5
    • /
    • 2011
  • The structural integrity assessment of APR1400 (Advanced Power Reactor 1400) reactor vessel internals has been being performed referring the US Nuclear Regulatory Commission regulatory guide 1.20 comprehensive vibration assessment program prior to commercial operation. The program is composed of a hydraulic and structural analysis, a vibration measurement, and an inspection. This paper describes the hydraulic and structural analysis on the reactor vessel internals due to hydraulic loads caused by the turbulence of reactor coolant. Three-dimensional models were built for the hydraulic and structural analysis and then hydraulic loads and structural responses were predicted for five analysis cases with CFX and ANSYS respectively. The structural responses show that the APR1400 reactor vessel internals have sufficient structural integrity in comparison with the acceptance criteria.

  • PDF

자외선 검출 카메라를 이용한 전력시스템의 안전진단에 관한 연구 (A Study on the Safety Diagnosis for Power Systems Using a UV Camera)

  • 유병열;김찬오
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.7-13
    • /
    • 2012
  • This paper describes the diagnosis techniques using UV images taken in the field under energized condition of power equipments in order to figure out and analyze the abnormal states on the terminals of power equipments. To classify the features of the terminals, the counted No. of the corona generated at the terminals is defined. According to the result detected, the No. of corona detected on the power equipments installed inside a building is less than that installed outside a building, and it strongly depends on the environment and installed condition. Thus, the environmental condition needs enhanced, and stable operation by the periodic inspection under energized condition of the power equipments is required. Especially, the event counting technique using UV camera is useful for the power equipments apart more than 20 m to apply, and there can be an error due to the features of the sensing techniques when the distance between the user and the objects is close less than 15 m. Therefore, the experimental result shows that event counting technique is employed in the case of the distance more than 15 m. The electrical safety can be ensured by using the UV detection technique and the criteria.

A Design-Decision Support Framework for Evaluation of Design Options in Passenger Ship Engine Room

  • 김수웅
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.277-280
    • /
    • 2006
  • Most real world design evaluation and risk-based decision support combine quantitative and qualitative (linguistic) variables. Decision-making based on conventional mathematics that combines qualitative and quantitative concepts always exhibit difficulty in modelling actual problems. The successful selection process for choosing a design/procurement proposal is based on a high degree of technical integrity, safety levels and low costs in construction, corrective measures, maintenance, operation, inspection and preventive measures. However, the objectives of maximising the degree of technical performance, maximising the safety levels and minimising the costs incurred are usually in conflict, and the evaluation of the technical performance, safety and costs is always associated with uncertainties, especially for a novel system at the initial concept design stage. In this paper, a design-decision support framework using a composite structure methodology grounded in approximate reasoning approach and evidential reasoning method is suggested for design evaluation of machinery space of a ship engine room at the initial stages. It is a Multiple Attribute Decision-Making (MADM) or Multiple Criteria Decision Making (MCDM) framework, which provides a juxtaposition of cost, safety and technical performance of a system during evaluation to assist decision makers in selecting the winning design/procurement proposal that best satisfies the requirement in hand. An illustrative example is used to demonstrate the application of the proposed framework.

  • PDF

나팔형 여수로를 가진 기존댐의 수리·수문학적 안전성평가에 관한 연구 (A Study on Evaluation for Hydraulic and Hydrologic Safety of an Existing Dam with Morning Glory Spillway)

  • 신은우;김경덕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.269-278
    • /
    • 2004
  • 본 연구에서는 절대적인 안전성이 요구되는 댐의 홍수방어능력을 확보하기 위해서 나팔형 여수로를 가진 기존댐에 대한 수리 수문학적 안전성을 평가하였다. 검토결과 현재의 설계홍수량인 520cms(EL. 170.30m)에 대해서는 홍수소통과 연직관의 부압발생의 문제가 없는 것으로 나타났으나, 오리피스 흐름으로 변환되는 EL. 170.70m를 초과하는 방류에는 한계가 있는 것으로 나타났으며, 웨어의 정점 부근에서 부압발생의 가능성이 있는 것으로 판단된다. 여유고를 고려한 댐최고수위는 EL. 170.5m를 넘지 않아야 하는데, 금번 저수지 홍수추적 결과 댐최고수위 EL. 172.46m로 약 2m 상회하는 것으로 나타나 이에 대한 근본적인 대책이 필요하다고 판단된다.

공동주택의 증축형 리모델링 안전진단 내구성 평가의 표본 수 최적화 방안 연구 (A Study on the Optimization of Field Sampling Number of the Durability Evaluation Method for the Extension Remodeling of the Apartment Housing)

  • 신희철;최기봉;윤상천
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권3호
    • /
    • pp.60-68
    • /
    • 2018
  • 주택법에 근거하여 철근콘크리트 공동주택의 리모델링 시 최대 3개층의 수직증축 및 기존 세대수의 15%까지 증축이 가능하게 되었다. 수직증축 리모델링 가능 여부는 안전진단 기준 및 매뉴얼을 바탕으로 기울기 및 침하, 내하력, 내구성 평가 부문에 대한 조사를 통하여 평가하고 판정하도록 되어 있다. 그러나 현행 증축형 리모델링 안전진단 기준 및 매뉴얼은 재건축 안전진단 기준과 비교하여 조사대상표본 수를 증대시키는 등 보수적인 것으로 평가되고 있으며, 특히 내구성 평가 부문에 검토 및 개선이 필요한 것으로 생각된다. 따라서 본 연구에서는 수도권 지역 공동주택의 증축형 리모델링 안전진단 조사 사례에 대한 내구성 조사 항목 중 콘크리트 탄산화를 대상으로 통계적인 수법에 의해 표본 수 합리화 방안을 제시하였다.

고속선 궤도회로 결함진단을 위한 개선방안 연구 (A Study on the Improvement for a Defect Diagnosis of Track Circuit on HSL)

  • 박기범;이태훈;이기천
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1656-1664
    • /
    • 2007
  • 본 논문에서는 고속선에 사용 중인 UM71C 궤도회로의 결함진단을 위한 개선방안을 연구하였다. 고속선 궤도회로는 구간이 길어 유지보수자에 의한 점검 시 많은 시간과 노력이 소요된다. 따라서 주기적으로 검측차를 운행하고 있다. 그러나, 궤도회로 결함 시 차상검측데이터의 변화를 정확히 알 수 없으므로 실제, 고속선 운행선상의 샘플개소를 선정하여 환경에 따른 선로정수를 구하고 전송라인의 특성임피던스와 전파정수를 반영시켜 단락전류에 대한 시뮬레이션을 수행하였으며, 임의의 지점에 결함을 발생시켜 측정한 결과와 시뮬레이션 수행한 결과를 비교하였다. 이렇게 검증된 시뮬레이션 프로그램을 이용하여 보상콘덴서의 기능저하 수량 및 용량변경에 따른 차상검측데이터를 예측하였다. 이것은 보상콘덴서의 기능저하를 사전 예측하여 열차의 안전운행을 확보하기 위해 필요하다. 또한 차상검측시스템에서 얻어진 검측데이터와의 비교를 통해 유지보수에 활용 가능한 활용지침 및 분석기준을 작성하기 위해 필요하다.

  • PDF