• Title/Summary/Keyword: safety etc.

Search Result 2,305, Processing Time 0.024 seconds

A Study on Concentration Analysis for Decreasing Air Pollutants (대기오염물질 저감을 위한 농도분석에 관한 연구)

  • Kim, Yun-Seon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.28-33
    • /
    • 2007
  • Often Regular Measurement Target 32 Spots which are distributed at Seo-gu in Incheon Metropolitan and Odour Emission Target 100 Factories based on the task instruction of Ministry of Environment in Korea were selected by considering to atmosphere phenomena and regional characteristics etc. This paper aims at building the Decreasing Prediction System of Odour which is capable of comparing and examining the concentration distribution by odour compounds, the distribution maps of odour diffusion and the contribution degree of sphere of influence, which is discharged from these above spots and factories.

The stress positioning control method for slim CRTs glass design using FEM

  • Hwang, Yoing-Ik;Lee, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1053-1057
    • /
    • 2007
  • One of the important roles of glass is safety guarantee in CRTs. It is working under high vacuum and has to be maintained continuously for the atmosphere pressure, humidity, and excitation etc,. This paper propose to CRTs glass design method via the stress positioning control for slim CRTs using FEM to ensure the national safety standard and newly demanded safety standard by CRTs set makers.

  • PDF

Improvement Direction of Construction Field Inspections : A Survey-Based (건설공사 현장점검 개선방안 마련을 위한 기초연구(설문조사 중심))

  • Han, Jae-Goo;Lee, Soo-Kyong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.188-189
    • /
    • 2015
  • This study was conducted a survey for suggesting direction of improvement of on­site inspections in Korean construction industry. The survey is limited perspective of owners, contractors and construction managers (including supervisors) about existing 'construction field inspection manual' with field inspections (eg. central inspection, central quality safety unit inspection etc.): focusing on stakeholder's perception and actual state of inspections.

  • PDF

A Study on Technology for Involute Bevel Gear Design (인벌류트 베벨기어 설계 기술에 관한 연구)

  • Cho, Seong-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2003
  • Design method for involute bevel gears is developed. The developed gear design system can design the optimized gear that minimize the number of pinion teeth with face tooth. Method of optimization is MS(matrix search) which is developed from this study. Design variables are pressure angle 20., transmitted power, gear volume, gear ratio, allowable contact stress and allowable bending stress. etc. Gears design method developed this study can be applied to the plane, helicopter, printer, machine tools.

A Study on the Protection of Electric Shock, in Low Voltage (저전압에서의 감전보호에 관한 연구)

  • 이재인
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.83-90
    • /
    • 1989
  • Recently, due to the increase of 220V distribution lines and equipments preventive measures to cope with several kinds of electric accidents is revealed as an urgent problem. This study investigates the following matters; the cause and present condition of e1ectric shock accident, the influence of electric shock on human body, the safety limit of electric shock, the method of distribution voltage, the insulation of electrical load apparatus, the teachnics of electric shock prevention and foreign materials concerned with this subject etc. This paper present the fundamental cause of electric shock and syntbetic preventive counter measure of electric shock, too.

  • PDF

Need for Reinforcement of Safety Assessment on Genetically Modified Organisms (GMO 안전성평가제도의 고찰)

  • Kim Eun-Jin;Choi Dong-Keun
    • Korean Journal of Organic Agriculture
    • /
    • v.14 no.2
    • /
    • pp.139-157
    • /
    • 2006
  • Biotechnology has reached the level of giving birth to new forms of life and with this is a growing controversy in the conflict between science and ethics. Especially, GMOs are closely linked to the food products we consume and thus, the majority of the public shows a very sensitive reaction to the safety of GMO food products. Many perspectives arose surrounding the issues of safety on the human body and the ecology. This outlines diverse structural mechanisms to be set up to ensure safety such as risk assessment, risk management etc. Despite the precautionary principle guaranteed in many ways, the problem arises whether and how this principle can be taken in the safety assessment. GMOs due to its uniqueness do not end with just the possession of the technology involved but must also be considered with the prerequisite that they could be cultured again. Therefore the reinforcement of safety assessment system is necessary. That is, the reinforcement of risk assessment including field tests, the consideration of socio-economic effects, the coordinated system of relevant authorities, the development of technology for safety assessment.

  • PDF

Investigation of Safety Standards for Motorcycle Stand, Rear Registration Plate and Anti-tampering Measures (이륜자동차 스탠드/번호판/튜닝금지 안전기준에 관한 연구)

  • Shin, Jaeho;Kim, Kyungjin;Yong, Boojoong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2018
  • Recently, many drivers of two-wheeled motorcycles in leisure and express delivery industries etc. brought increasing issues for the motorcycle safety. This paper has studied the structural safety of two-wheeled motorcycles considering the regulations for stand, rear registration plate and anti-tampering measures. The authors have investigated and compared a variety of international and domestic regulations and specifications for structural safety of those components. Detailed experimental procedures of stand, mounting for rear registration plate and anti-tampering measures are proposed to secure the two-wheeled motorcycle safety and the outcomes of this study can be used to confirm the Korean motor vehicle safety standards.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle (수소연료전지자동차의 절연성능 평가방법에 관한 고찰)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.810-818
    • /
    • 2011
  • This paper analyzed the suitability about the isolation performance criteria which was based on human impedance and effect of current in IEC 60479-1 on the safety of human being was examined. The method of evaluation by megger and DC voltmeter was analyzed. The differences of isolation performance according to design of high-voltage system were analyzed. The factors which affect the insulation performance were analyzed for HFCV, EV, HEV, etc. through analysis of the isolation performance evaluation method. Finally, design for improved isolation performance was proposed.

A Safety Analysis on the Fire Endurance of Concrete Structures (화재에 대한 콘크리트구조물의 안전성 해석)

  • Bang, Myung-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • Fire disasters have frequently happened in concrete structures, which resulted in severe structural damages and unsafety. In this case, the method which had evaluated the safety of damaged structures was often unaccepted from most of stakeholders and engineers. The objective of this study is to develope the procedure and method to be able to determine the safety. Numerical simulation was applied to produce the maximum temperature and temperature distribution. Nextly, temperature propagation analysis was performed to plot temperature gradients at each depth and location. The material strength curve versus temperature was applied to determine the safety of concrete structures damaged by fire. The maximum temperature should be calibrated considering real fire records ; magnitude, intensity, situation etc. The results shows that the selected procedure and method was applicable and practical.

The analysis of field condition for electrical equipments in places containing sauna heaters, public bath and etc. (찜질방의 전기설비 현장실태조사 결과 분석)

  • Yi, Geon-Ho;Hwang, Kwang-Su;Kim, Han-Sang;Bae, Seok-Myung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.239-244
    • /
    • 2005
  • 불특정 다수의 사람들이 이용하고 있는 찜질방은 업소의 특성에 적합한 시설기준이 미비한 상태이므로 언제든지 감전사고와 같은 안전사고의 위험이 도사리고 있다. 본 논문에서는 찜질방의 전기설비와 관련된 국내 외 시설규정을 참고하여 실제 적용 가능한 시설기준을 제시하고, 현장실태조사 결과를 분석하여 나타난 문제점을 파악하고 점검, 유지 및 관리에 있어서의 착안 사항을 제시하고자 한다.

  • PDF