• Title/Summary/Keyword: safety equipment

Search Result 2,939, Processing Time 0.03 seconds

The Special Plan of the Traffic Accident Treatment in the Emergency Car Concerning Fire Fighting (소방관련 긴급자동차의 교통사고처리 특례방안)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The traffic accident of Fire engine takes place very much, compared with that of the past. The reason is that there is a lot of the increase of the demand in the fire, rescue, first aid, and the public request. Also, because the Fire engine should go out at the place of the accident very quickly, it should inevitably violate the traffic regulations. Therefore, this is due to the traffic accident. Despite the urgent situation in the infringement motive of traffic regulations, the outbreak of the traffic accident does not vary largely from the degree of the disadvantage. Accordingly, a fire officer should take charge of his social and economic disadvantage by himself. In this situation, a fire officer has no choice but to start moving passively not to be afflicted with his own disadvantage. Most of the situations concerning the fire fighting are the ones to be controlled urgently. Nevertheless, because of the disadvantage of the traffic accident, passive mobilization of the fire fighting equipment is the heavy burden of all the people of the nation. Therefore, Special institutional safety device should be ready for the protection of the life and property of all people. The special law concerning the processing in the accident of the emergency car needs to be revised. By establishing this special law, the government should not provide the officer who drives the fire engine with the disadvantage caused by traffic accident.

Studies of application of artificial ground freezing for a subsea tunnel under high water pressure - focused on case histories - (고수압 해저터널 건설을 위한 동결공법 적용성에 관한 연구 - 사례를 중심으로 -)

  • Son, Young-Jin;Lee, Kyu-Won;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.5
    • /
    • pp.431-443
    • /
    • 2014
  • In this paper case studies of artificial ground freezing, which have not been applied in Korea, have been investigated for the water cut-off in a subsea tunnel under high water pressure and the most commonly used cooling mediums of brine and liquid nitrogen are examined. Since sea water with pressure has the lower freezing point than pure water, the lower temperature cooling medium is required in the application of subsea tunnel. Also, the cooling medium must have refrigeration safety and is able to reduce executing time. Brine freezing system can reuse cooling medium and is safer than liquid nitrogen freezing. But it takes more time to freeze ground and needs complex circulation plants. On the other hand, liquid nitrogen freezing system can't recycle cooling medium and may cause breathing problems or asphyxiation through oxygen deficiency. But, freezing with liquid nitrogen is fast and requires simple refrigeration equipment. Principal elements of design for ground freezing in subsea tunnel have been extracted and these elements are needed further research.

Analysis of Slope Fracturing using a Terrestrial LiDAR (지상라이다를 이용한 사면파괴 거동분석)

  • Yoo, Chang-Ho;Choi, Yun-Soo;Kim, Jae-Myeong
    • Spatial Information Research
    • /
    • v.16 no.3
    • /
    • pp.279-290
    • /
    • 2008
  • Landslide, one of the serious natural disasters, has Incurred a large loss of human and material resources. Recently, many forecasting or alarm systems based on various kinds of measuring equipment have been developed to reduce the damage of landslide. However, only a few of these equipments are guaranteed to evaluate the safety of whole side of land slope with their accessibility to the slope. In this study, we performed some experiments to evaluate the applicability of a terrestrial LiDAR as a surveying tool to measure the displacement of a land slope surface far a slope collapsing protection system. In the experiments, we had applied a slope stability method to a land slope and then forced to this slope with a load increasing step by step. In each step, we measured the slope surface with both a total station and a terrestrial LiDAR simultaneously. As the result of Slope Fracturing analysis using all targets, the LiDAR system showed that three was 1cm RMSE on X-axis, irregularity errors on Y-axis and few errors on Z-axis compare with Total Station. As the result of Slope Fracturing analysis using continuous targets, the pattern of Slope Fracturing was different according to the location of continuous targets and we could detect a continuous change which couldn't be found using Total station. The accuracy of the LiDAR data was evaluated to be comparable to that of the total station data. We found that a LiDAR system was appropriate to measuring the behaviour of land slope. The LiDAR data can cover the whole surface of the land slope, whereas the total station data are available on a small number of targets. Moreover, we extracted more detail information about the behavior of land slope such as the volume and profile changes using the LiDAR data.

  • PDF

Evaluation of Installation Length of CWR Considering Rail Tenser's Capacity And Track Maintenance (레일긴장기의 성능을 고려한 효율적인 장대레일 설정방법)

  • Park, Ok-Jeong;Kim, Eung-Rok
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.72-79
    • /
    • 2010
  • The significant of continuous welded rail (CWR) management is growing because KORAIL has the plan to convert the whole of conventional railway lines into CWRs through continuous activities since constructed the CWR track with 1.8km in Gyeongbu line in 1966. The CWR recently is needed a efficient management method because it is difficult to manage the CWR by the poor of technic and equipment, limited maintain labor force and shorted the maintain work time of CWR caused by industrialization, greenhouse effect and global warming In this point, The 70ton Tenser's which is using in the rail site has been analysised with no extra tenser's capacity in case of the under low temperature and exceed the length of 1km as a result of reviewing the CWR-related rules and standards, a series of records of safety accidents, operation obstacles, and the situation of broken rails published by KORAIL, existing rail temperature measurements, and CWR researches. Therefore avoid the excessive plan of the first set-up section, choice the proper time in the normal temperature that is possible to weld the rail, turning the difference of rail temperature and Installation temperature down is desirable.

  • PDF

Evaluation of Microbiological Hazard of Cooking Utensils and Environment of Large Foodservice Establishments in Daegu city (대구지역 대형 식품접객업소 조리기기 및 환경에 대한 미생물학적 위해분석)

  • Nam Eun-Jeong;Kang Young-Jae;Lee Yeon-Kyung
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.234-240
    • /
    • 2006
  • The purpose of this study was to evaluate microbiologically cooking utensils, equipment employees, and environment in 12 large Korean, Western, Chinese, and Japanese restaurant. Microbiological testing was conducted for pathogens including E. coli, Samolnella, L. monocytogenes, S. aureus, E. coli O157:H7, V. parahaemolyticus, B. cereus, and Y. enterocolitica as well as total plate count and coliforms. The results showed cooking water and drinking water in some Korean restaurants and drinking water in some Western and Japanese restaurants were unsatisfactory, especially, barley tea, which was cooled after being boiled, was unsatisfactory. Most cooking utensils such as knives, cutting boards, kitchen towels, tongs, and basket had total plate and coliforms count in excess of standards, and knives and cutting boards at some Chinese restaurant had E. coli. At some restaurant, S. aureus was found on some food worker's hands. Also, the total plate count of the air showed a high count around worktables, inside the refrigerator, and in the kitchen in most restaurants. These result suggest that sanitation needs improvement in the environments in these foodservice establishment.

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

Proposal on for Response System to primary leaders' Terrorism (국가요인 테러리즘의 대응체제 구축방안)

  • Suh, Sang-Yul
    • Korean Security Journal
    • /
    • no.11
    • /
    • pp.61-86
    • /
    • 2006
  • Various terrorism in modern society against nation's dignitaries are constantly existing. They damage severely to the society and the nation's security, and they cause disorganizations of social and national rule orders. In order to provide the key figures' perfect protection, the threatening terroizing environment for primary leaders and the route of terrorism should be intercepted. Effective methods of these are summarized as follow. First, recent terrorism against the primary leaders are mostly assassinations, bomb attacks, and suicide bomb attacks, which terminate in a moment. Therefore, security service agents should keep in mind that protection is the best, and government's anti-terrorism agencies should develop policies and set the directions within a new paradigm to the advance anti-terrorism. Second, advance prevention activities against nation's VIP terrorism should be strengthened, such as strengthening security informational activities, constructing cooperative systems of domestic and international facilities, considering continuous system to prevent terrorism, and intensifying safety counterplans of human and material weak points. Third, international cooperative system should be set to apply economical and political sanctions to nations which support terror organizations in direct or indirect ways, and this system needs to strengthen the punishment against terrorists. Fourth, security systems to protect nation's primary leaders should complement, and developing programs for coping with the terrorism and establishing laws for anti-terrorism should be made. Also, educational training of agents who perform anti-terrorism duties should be strengthened, and scientific techniques and equipment for security should be made to protect primary leaders from terrorism.

  • PDF

Counter-Terrorism Strategy of Terrorism and Developmental plan of Private Security in Korea (한국의 테러리즘의 대테러전략과 민간시큐리티의 역할증대방안)

  • Park, Jun-Seok
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.195-214
    • /
    • 2007
  • The purpose of this research is to suggest a construction device that can transform a public safety, security service, security system on counter-terrorism device system, from government leading type to private management type. There are purpose on this thesis to research for the bringing up counter-terrorism experts certification system and about all sorts of developed device among our country's counter-terrorism situation and through comparing developed country's private security's developing device. This summary of thesis is like below. First we need to establish total counter-terrorism center, like developed country on national corresponding strategy. Second, we need to make an organization as a country security department unified as an America's President directly belonging organization. Third, it is to legislate about an counter-terrorism. Fourth, we need to make a coorperate system according to counter-terrorism duty come under private management, so that can recover a trust among people. Fifth, a terror warning system is necessary. Private security's mutual relationship and developing devices is First, it is necessary to bring up counter-terrorism expert. Second, it is necessary to bring in counter-terrorism experts certification system. Third, counter-terrorism research center that come under private management is necessary. The university, private security related academy, should establish research center for the private security industry's specialization, subdivision. It is considered that various research need to be continued after by bringing up counter-terrorism experts, transforming a consciousness, counter-terrorism education, building an equipment and education center, not for a special group, that can minimize human infringement.

  • PDF

Application for Fire Protection Regulation based on Risk-Informed and Performance-Based Analysis (위험도 및 성능기반 분석방법에 의한 원전 화재방호규정 적용 방안)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.65-70
    • /
    • 2006
  • From the beginning of the construction stage, the fire protection regulation for the nuclear power plants conforms to the design requirements for the acquisition of the license permit. This regulation is based on the plant status of the normal operation, but it is not enough to be used as an application standard for fire protection at the transient mode of the plant and the outage time for refueling as well as for the plant decommissioning. While the advanced fire protection requirement that has been developed in America recently suggests the performance-based requirement and management rule applicable to the overall life time of the plant, it simply represents the conceptual application. It means that it can not be treated as appropriate standards because it does not deal with the qualitative and quantitative approach in specific ways. By the way, with the use of the performance-based fire risk analysis, the dynamic behavior of the heat and smoke at the fire compartment of the nuclear power plants can be analyzed and the thermal effect to the safety-related equipment and cables can be evaluated as well. At this paper, it suggests the ways to change the applicable fire protection regulations and the required evaluation items for the fire risk resulted from the plant configuration change with an intent to introduce the state-of-the-art quantitative fire risk analysis technology at the domestic nuclear power plants.

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise