• Title/Summary/Keyword: safe performance

Search Result 1,183, Processing Time 0.034 seconds

Performance Analysis of Simultaneous Liftable 3D Concrete Printing Based on Statistical Analysis Algorithm (통계분석 알고리즘 프로그램을 활용한 동시 인상 3D 콘크리트 프린팅의 성능 분석)

  • Yoon-Chul Kim;Sung-Jo Kim;Bongsik Kim;Yongsoo Ji;Tong-Seok Han
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.6
    • /
    • pp.407-414
    • /
    • 2023
  • In this study, an automated jack-up system, applicable to various fields, was employed for 3D concrete printing and developed as a simultaneous liftable 3D concrete printing system. This developed printing system enables safe and precise jack-up by monitoring the measured jack-up distance using Pearson correlation coefficient analysis and a hydraulic system with interquartile range analysis in real-time during 3D concrete printing operations. It is possible to secure the quality of 3D concrete printing structures, which is essential for expanding the application of 3D concrete printing to construct larger structures. Specimens were printed using both conventional 3D concrete printing and simultaneous liftable 3D concrete printing to evaluate the system performance. The printed specimens were investigated using a 3D scanner. The layer-wise diameter and angle of intersection of the scanned specimens were measured, and an analysis was performed to verify the advantages of the simultaneous liftable 3D concrete printing.

Development of Evaluation Indicators for Optimizing Mixed Traffic Flow Using Complexed Multi-Criteria Decision Approaches (다기준 복합 가중치 결정 기반 혼재 교통류 최적화 평가지표 개발)

  • Donghyeok Park;Nuri Park;Donghee Oh;Juneyoung Park
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.157-172
    • /
    • 2024
  • Autonomous driving technology, when commercialized, has the potential to improve the safety, mobility, and environmental performance of transportation networks. However, safe autonomous driving may be hindered by poor sensor performance and limitations in long-distance detection. Therefore, cooperative autonomous driving that can supplement information collected from surrounding vehicles and infrastructure is essential. In addition, since HDVs, AVs, and CAVs have different ranges of perceivable information and different response protocols, countermeasures are needed for mixed traffic that occur during the transition period of autonomous driving technology. There is a lack of research on traffic flow optimization that considers the penetration rate of autonomous vehicles and the different characteristics of each road segment. The objective of this study is to develop weights based on safety, operational, and environmental factors for each infrastructure control use case and autonomous vehicle MPR. To develop an integrated evaluation index, infra-guidance AHP and hybrid AHP weights were combined. Based on the results of this study, it can be used to give right of way to each vehicle to optimize mixed traffic.

Fluoroscopy-Guided Percutaneous Transthoracic Pleural Forceps Biopsy in Patients With Exudative Pleural Effusion

  • Doo Ri Kim;In Chul Nam;Hye Jin Baek;Jeong Jae Kim;Im Kyung Hwang;Jeong Sub Lee;Duk Ju Kim;Chang Lim Hyun;Sung Eun Park;Sung Wook Song
    • Korean Journal of Radiology
    • /
    • v.25 no.8
    • /
    • pp.706-714
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic performance and procedural characteristics of fluoroscopy-guided percutaneous transthoracic pleural forceps biopsy (PTPFB) in patients with exudative pleural effusion. Materials and Methods: Patients with exudative pleural effusion who underwent PTPFB between May 1, 2014, and February 28, 2023, were included in this retrospective study. The interval between percutaneous catheter drainage (PCD) and PTPFB, number of biopsies, procedural time, and procedure-related complications were evaluated. The sensitivity, specificity, and accuracy of diagnosing malignancy were computed for pleural cytology using PCD drainage, PTPFB, and combined PTPFB and pleural cytology. Results: Seventy-one patients, comprising 50 male and 21 female (mean age, 69.5 ± 15.3 years), were included in this study. The final diagnoses were benign lesions in 48 patients (67.6%) and malignant in 23 patients (32.4%). The overall interval between PCD and biopsy was 2.4 ± 3.7 days. The interval between PCD and biopsy in the group that underwent delayed PTPFB was 5.2 ± 3.9 days. The mean number of biopsies was 4.5 ± 1.3. The mean procedural time was 4.4 ± 2.1 minutes. Minor bleeding complications were reported in one patient (1.4%). The sensitivity, specificity, and accuracy for pleural cytology, PTPFB, and combined PTPFB and pleural cytology were 47.8% (11/23), 100% (48/48), and 83.1% (59/71), respectively; 65.2% (15/23), 100% (48/48), and 88.7% (63/71), respectively; and 78.3% (18/23), 100% (48/48), and 93.0% (66/71), respectively. The sensitivity and accuracy of cytology combined with PTPFB were significantly higher than those of cytological testing alone (P = 0.008 and 0.001, respectively). Conclusion: Fluoroscopy-guided PTPFB is an accurate and safe diagnostic technique for patients with exudative pleural effusion, with acceptable diagnostic performance, low complication rates, and reasonable procedural times.

External Beam Radiotherapy in the Management of Low Grade Astrocytoma of the Brain (뇌 성상세포종 환자의 외부 방사선치료)

  • Chun, Ha-Chung
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effectiveness of postoperative radiotherapy for patients with low-grade astrocytomas and to define an optimal radiotherapeutic regimen and prognostic factors. Materials and Methods: A total of 69 patients with low-grade astrocytomas underwent surgery and postoperative radiotherapy immediately following surgery at our institution between October 1989 and September 2006. The median patient age was 36 years. Forty-one patients were 40 years or younger and 28 patients were 41 years or older. Fourteen patients underwent a biopsy alone and the remaining 55 patients underwent a subtotal resection. Thirty-nine patients had a Karnofsky performance status of less than 80% and 30 patients had a Karnofsky performance status greater than 80%. Two patients were treated with whole brain irradiation followed by a coned down boost field to the localized area. The remaining 67 patients were treated with a localized field with an appropriate margin. Most of the patients received a dose of $50\sim55$ Gy and majority of the patients were treated with a dose of 54 Gy. Results: The overall 5-year and 7-year survival rates for all of the 69 patients were 49% and 44%, respectively. Corresponding disease free survival rates were 45% and 40%, respectively. Patients who underwent a subtotal resection showed better survival than patients who underwent a biopsy alone. The overall 5-year survival rates for patients who underwent a subtotal resection and patients who underwent a biopsy alone were 57% and 38%, respectively (p<0.05). Forty-one patients who were 40 years or younger showed a better overall 5-year survival rate as compared with 28 patients who were 41 years or older (56% versus 40%, p<0.05). The overall 5-year survival rates for 30 patients with a Karnofsky performance status greater than 80% and 39 patients with a Karnofsky performance status less than 80% were 51% and 47%, respectively. This finding was not statistically significant. Although one patient was not able to complete the treatment because of neurological deterioration, there were no significant treatment related toxicities. Conclusion: Postoperative radiotherapy following surgery is a safe and effective treatment for patients with low-grade astrocytomas. The extent of surgery and age were noted as significant prognostic factors in this study. However, further effective treatment might be necessary in the future to improve long-term survival rates.

N- and P-doping of Transition Metal Dichalcogenide (TMD) using Artificially Designed DNA with Lanthanide and Metal Ions

  • Kang, Dong-Ho;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.292-292
    • /
    • 2016
  • Transition metal dichalcogenides (TMDs) with a two-dimensional layered structure have been considered highly promising materials for next-generation flexible, wearable, stretchable and transparent devices due to their unique physical, electrical and optical properties. Recent studies on TMD devices have focused on developing a suitable doping technique because precise control of the threshold voltage ($V_{TH}$) and the number of tightly-bound trions are required to achieve high performance electronic and optoelectronic devices, respectively. In particular, it is critical to develop an ultra-low level doping technique for the proper design and optimization of TMD-based devices because high level doping (about $10^{12}cm^{-2}$) causes TMD to act as a near-metallic layer. However, it is difficult to apply an ion implantation technique to TMD materials due to crystal damage that occurs during the implantation process. Although safe doping techniques have recently been developed, most of the previous TMD doping techniques presented very high doping levels of ${\sim}10^{12}cm^{-2}$. Recently, low-level n- and p-doping of TMD materials was achieved using cesium carbonate ($Cs_2CO_3$), octadecyltrichlorosilane (OTS), and M-DNA, but further studies are needed to reduce the doping level down to an intrinsic level. Here, we propose a novel DNA-based doping method on $MoS_2$ and $WSe_2$ films, which enables ultra-low n- and p-doping control and allows for proper adjustments in device performance. This is achieved by selecting and/or combining different types of divalent metal and trivalent lanthanide (Ln) ions on DNA nanostructures. The available n-doping range (${\Delta}n$) on the $MoS_2$ by Ln-DNA (DNA functionalized by trivalent Ln ions) is between $6{\times}10^9cm^{-2}$ and $2.6{\times}10^{10}cm^{-2}$, which is even lower than that provided by pristine DNA (${\sim}6.4{\times}10^{10}cm^{-2}$). The p-doping change (${\Delta}p$) on $WSe_2$ by Ln-DNA is adjusted between $-1.0{\times}10^{10}cm^{-2}$ and $-2.4{\times}10^{10}cm^{-2}$. In the case of Co-DNA (DNA functionalized by both divalent metal and trivalent Ln ions) doping where $Eu^{3+}$ or $Gd^{3+}$ ions were incorporated, a light p-doping phenomenon is observed on $MoS_2$ and $WSe_2$ (respectively, negative ${\Delta}n$ below $-9{\times}10^9cm^{-2}$ and positive ${\Delta}p$ above $1.4{\times}10^{10}cm^{-2}$) because the added $Cu^{2+}$ ions probably reduce the strength of negative charges in Ln-DNA. However, a light n-doping phenomenon (positive ${\Delta}n$ above $10^{10}cm^{-2}$ and negative ${\Delta}p$ below $-1.1{\times}10^{10}cm^{-2}$) occurs in the TMD devices doped by Co-DNA with $Tb^{3+}$ or $Er^{3+}$ ions. A significant (factor of ~5) increase in field-effect mobility is also observed on the $MoS_2$ and $WSe_2$ devices, which are, respectively, doped by $Tb^{3+}$-based Co-DNA (n-doping) and $Gd^{3+}$-based Co-DNA (p-doping), due to the reduction of effective electron and hole barrier heights after the doping. In terms of optoelectronic device performance (photoresponsivity and detectivity), the $Tb^{3+}$ or $Er^{3+}$-Co-DNA (n-doping) and the $Eu^{3+}$ or $Gd^{3+}$-Co-DNA (p-doping) improve the $MoS_2$ and $WSe_2$ photodetectors, respectively.

  • PDF

Effects of Visiting Prehabilitation Program against Functional Decline in the Frail Elderly: A Prospective Randomized Community Trial (허약노인을 위한 방문재활 프로그램의 장애발생예방 효과에 대한 연구)

  • Kim, Chang-O;Lee, Heeyeon;Ho, Seung Hee;Park, Hyunsuk;Park, Chulwoo
    • 한국노년학
    • /
    • v.30 no.4
    • /
    • pp.1293-1309
    • /
    • 2010
  • This study is aimed to evaluate the effects of community-based prehabilitation program developed to prevent functional decline in the frail elderly and to provide a basis to practically operate this program in the public health care service. From March to August 2009, 110 frail elderly people were recruited among the registered participants of the home visit program in Korea to perform a prospective randomized community trial. We randomly assigned these people into two groups. One group (n=50) participated in the visiting prehabilitation program for 3 months focusing on improving their muscle strength of upper and lower limbs, walking ability, and balancing. The other group (n=60) underwent our visiting fall prevention program for control. To assess the effectiveness of prehabilitation program, physical functioning (PF) and short physical performance battery (SPPB) were measured for the primary outcomes and also some other indicators: exercise performance, nutritional status, emotional functioning, experience of admission, and events of fall. As a result, significant improvements of geriatric functional status were noticed among the participants. After 3 months, PF increased by 1.3 ± 3.8 points in prehabilitation group and decreased by 1.1 ± 5.4 points in controls (p=.020). SPPB improved by 2.4 ± 2.0 points in prehabilitation group and increased only 0.3 ± 1.5 points in controls (p<.001). Significant effects were also shown in their exercise performance tests and emotional status, the number of multiple falls, and the experience of functional decline after the fall (p .002-.038). Visiting prehabilitation program is safe and effective program for frail older adults. Thus, it is strongly recommended to universally adopt this program to prevent functional decline in the frail elderly.

Quantitatation of Benzoic and Sorbic Acids in Some Processed Foods of Korea (일부 한국 가공식품의 벤조산과 소르빈산의 함량 조사)

  • Mitra, Sanika;Han, Jang-Il;Lee, Ki-Teak;Kim, Seong-Ai
    • Food Science and Preservation
    • /
    • v.16 no.6
    • /
    • pp.789-796
    • /
    • 2009
  • Benzoic acid (BA) and sorbic acid (SA) are the preservatives most commonly used in food. Although BA and SA are generally safe, some previous studies have shown that consumption of excessive amounts of these food additives can be a health hazard. The aim of this study was to determine the amounts of BA and SA in processed foods in Korea. Different brands of fruit juice, yogurt, cheese, dried fruits, jam, and margarine were purchased at a local market in Daejeon, Korea. Samples were analyzed by high-performance liquid chromatography (HPLC) using a UV detector. Chromatographic separation was achieved with a C18 column. Methanol acetate buffer (pH 4.4) at a 35:65 v/v ratio was used as the initial mobile phase to elute BA and SA. The detector wavelength was set at 254 nm. The average test results observed for BA concentrations in fruit juice, yogurt, cheese, dried fruits, jam, and margarine were $40.26{\pm}0.02$, $2.07{\pm}0.06$, $0.02{\pm}0.09$, $0.36{\pm}08$, $265.30{\pm}0.02$, and $27.34{\pm}0.08\;mg/kg$, respectively. Average concentrations of SA in these samples were $0.92{\pm}0.06$, $1.06{\pm}0.07$, $7.30{\pm}0.01$, $14.14{\pm}0.08$, $25.65{\pm}0.06$, and $4.81{\pm}0.07\;mg/kg$, respectively. Thus, the average levels of BA and SA in the studied food items were lower than the KFDA-permitted limits. Moreover, the estimated daily intake of both BA and SA by a typical consumer were below the maximum recommended daily values.

A Design of Low Cost Differential GPS System based on Web-Service (웹서비스 기반의 저가형 위성항법보정시스템 설계)

  • Jung, Se-Hoon;Seo, Ho-Seok;Park, Dong-Gook;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.487-498
    • /
    • 2013
  • A variety of location-based services applications, such as missing children search, emergency rescue requests and so on that requiring high-precision location information are increasing. Precision of GPS that can be used in most systems, however, is still low. In this paper, we design and propose a low cost differential global positioning system(DGPS) based on Web services using object-oriented modeling technique which can offer useable location service, variety device and safe service in wireless environment. The proposed system is designed with UML based on object-oriented modeling to maximize system recyclability and system scalability. In addition, we would like to improve the precision of the GPS in accordance with mobile station location when build low cost mobile station, location differential framework and server. We implement a communication interface based on web-service which is available in the form of a variety of services and can offer stable according to mobile environments. Finally, as performance evaluation results, we can obtain precision location within 1 ~ 2m through proposed system and 88.5% probability of less than 2m.

Effects of Different Dietary Cadmium Levels on Growth and Tissue Cadmium Content in Juvenile Parrotfish, Oplegnathus fasciatus

  • Okorie, Okorie E.;Bae, Jun Young;Lee, Jun-Ho;Lee, Seunghyung;Park, Gun-Hyun;Mohseni, Mahmoud;Bai, Sungchul C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • This feeding trial was carried out to evaluate the effects of different dietary cadmium levels on growth and tissue cadmium content in juvenile parrotfish, Oplegnathus fasciatus, using cadmium chloride ($CdCl_2$) as the cadmium source. Fifteen fish averaging $5.5{\pm}0.06$ g (mean${\pm}$SD) were randomly distributed into each of twenty one rectangular fiber tanks of 30 L capacity. Each tank was then randomly assigned to one of three replicates of seven diets containing 0.30 ($C_0$), 21.0 ($C_{21}$), 40.7 ($C_{41}$), 83.5 ($C_{83}$), 162 ($C_{162}$), 1,387 ($C_{1,387}$) and 2,743 ($C_{2,743}$) mg cadmium/kg diet. At the end of sixteen weeks of feeding trial, weight gain (WG), specific growth rate (SGR) and feed efficiency (FE) of fish fed $C_{21}$ were significantly higher than those of fish fed $C_{83}$, $C_{162}$, $C_{1,387}$ and $C_{2,743}$ (p<0.05). Weight gain, SGR and FE of fish fed $C_0$, $C_{21}$ and $C_{41}$ were significantly higher than those of fish fed $C_{162}$, $C_{1,387}$ and $C_{2,743}$. Protein efficiency ratio of fish fed $C_0$, $C_{21}$ and $C_{41}$ were significantly higher than those of fish fed $C_{1,387}$ and $C_{2,743}$. Average survival of fish fed $C_0$, $C_{21}$, $C_{41}$ and $C_{162}$ were significantly higher than that of fish fed $C_{2,743}$. Tissue cadmium concentrations increased with cadmium content of diets. Cadmium accumulated the most in liver, followed by gill and then muscle. Muscle, gill and liver cadmium concentrations of fish fed $C_0$, $C_{21}$, $C_{41}$ and $C_{83}$ were significantly lower than those of fish fed $C_{162}$, $C_{1,387}$ and $C_{2,743}$. Based on the ANOVA results of growth performance and tissue cadmium concentrations the safe dietary cadmium level could be lower than 40.7 mg Cd/kg diet while the toxic level could be higher than 162 mg Cd/kg diet.

Injury Study for Q6 and Q10 Child Dummies (Q6, Q10 어린이 인체모형의 상해치 연구)

  • Sun, Hongyul;Lee, Seul;Seok, Juyup;Yoo, Wonjae;Yoon, Ilsung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.8 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • The Child Occupant Safety Assessment was first introduced and carried out by Euro NCAP in 2003, with the goal of ensuring manufacturers to develop safe vehicles for passengers of all ages; the objective was to evaluate the safety and protection offered by different Child Restraint Systems (CRS) in the event of a crash. In 2013, the formerly used P child dummy series was replaced by newer and more biofidelic Q1.5 and Q3 child dummies, representing 1.5 and 3 year old children respectively. The frontal and side impact dynamic performances of the Q1.5 and Q3 were tested within all classes of vehicles assessed by Euro NCAP at the time. As an extension to that initiative, Q6 and Q10 child dummies were later developed representing children of 6 and 10 years old. Since the protection of larger children during vehicle crashes relies greatly on the interaction of vehicle restraint systems such as seat belt and the CRS, instrumented Q6 and Q10 dummies will be used to assess the protection offered in the event of front and side impact crashes. In this paper, we focused on injury criteria of Q6 and Q10 child dummies at 64 kph 40% offset frontal crash test. The whole procedure was designed with DFSS analysis. The full vehicle sled test results of both dummies were conducted with different restraint systems settled through previous sled test. It showed that several injury criteria and image data were collected as the result of the full vehicle sled test. Based on the results of these investigations, this paper describes which factor is most important and combination shows the best performance when evaluating rear seat occupant protection for Q6 and Q10 child dummies.