• Title/Summary/Keyword: running average

Search Result 279, Processing Time 0.028 seconds

The Effect of Ozonized Water Irrigation in the Circuits of Professional Ultrasonic Scalers for Causal Therapy of Stage I Periodontitis: A Randomized Clinical Study

  • Simone Marconcini;Enrica Giammarinaro;Giacomo Oldoini;Annamaria Genovesi
    • Journal of dental hygiene science
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2023
  • Background: Periodontitis is a chronic inflammatory condition associated with dysbiosis of the oral microbiota. The aim of the present clinical study was to explore the adjunctive effect of ozonized water irrigation in the circuits of ultrasonic scalers for the full-mouth decontamination of patients with periodontitis Stage I or II. Methods: The study was a randomized, single-blinded, parallel-group clinical trial. The test group (n=25) was treated with ultrasonic scalers irrigated with ozonized water, whereas the control group (n=25) received normal tap water irrigation within the ultrasonic scalers used during the professional mechanical debridement. Full mouth plaque score, bleeding score, probing pocket depth, and the gingival index were evaluated at baseline, two, and 4 weeks after treatment. The pain perceived and dental anxiety were also assessed after treatment by means of the visual analog scale (VAS). Results: All periodontal parameters resulted in significant improvement for both study groups. The effect of the treatment group on the gingival index was significant, in particular, patients in the test group experienced a greater reduction in this score. No significant differences could be observed with regards to the average probing depth, full mouth plaque index and bleeding score. Patients treated with ozonized water running in the circuits of ultrasonic scalers displayed also lower scores for pain and dental anxiety. Conclusion: The present study showed a significant clinical effect on gingival inflammation attributable to adjunctive ozone irrigation during nonsurgical periodontal therapy. Further studies, including patients with severe periodontitis and greater sample sizes, are recommended to test the clinical effect of ozonized water in the circuits of ultrasonic scalers.

Winning Rate Improvement of the Korea Professional Baseball teams on Pythagorean method and Record (피타고라스 지수의 추정과 기록을 통한 한국프로야구 구단의 승률향상 방안)

  • Bae, Jung-Sup;Shin, Sun-Yun
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.6
    • /
    • pp.361-373
    • /
    • 2016
  • The winning rate is the most important indicator for running a professional baseball team because it directly affects the spectator. James(1980) suggests that the Pythagorean method is almost identical to the actual winning rate, which is known as a way of helping to establish a team strategy. In this study, it was analyzed what kind of detail difference produced difference between real winning rate and winning rate based on Pythagorean method for 10 years from 2005 to 2014. The purpose of this study is to derive a plan to improve the performance of Korean professional baseball team. The results show that the expected winning rate differs from the actual winning rate by +.062 to -.054. In the process of this result, records of base on balls of the hitter, strikeout of the hitter, base on balls of the pitcher, batting average, sacrifice fly, etc. were found to affect the performance of professional baseball team. Therefore professional baseball teams should improve their batting eye so they can get a base on balls and reduce strikeouts. In the case of a pitcher, it should be instructed to reduce the base on balls by improving the control.

Thermal Dynamics of Core and Periphery Temperature during Treadmill Sub-maximal Exercise and Intermittent Regional Body Cooling (트래드밀에서의 최대하 부하 운동과 간헐적 부위별 인체 냉각 시 심부와 말초 부위의 체온 변화)

  • Lee, Joo-Young;Koscheyev, Victor S.;Kim, Jung-Hyun;Warpeha, Joe M.
    • Journal of Korean Living Environment System
    • /
    • v.16 no.2
    • /
    • pp.89-100
    • /
    • 2009
  • The present study was designed to observe the thermal dynamics of core and skin temperatures during sub-maximal treadmill exercise; to investigate the effect of regional body cooling during short rest after the treadmill exercise on the thermal dynamics. Three conditions (No cooling, Head/Hand cooling, Leg cooling) were simulated in a climatic chamber at 24±1℃ and 50±5%RH. Subjects performed two bouts of treadmill exercise at a rate of 80%HRmax followed by rest. Body cooling with a hood, long gloves, and a blanket that circulated water set at 15℃ was assigned during two bouts of rest. The results showed that (1) rectal temperature (Tre) did not show significant difference between three conditions; (2) Skin temperatures had specific features, depending on body regions. In particular, the initial fall phenomena of skin temperatures at the onset of exercise were noteworthy in the chest, thigh, calf, and finger tip. Of these, the most significant initial fall was found in finger temperature (Tfing). (3) During the period of the initial fall in skin temperatures, Tre gradually increased. (4) The magnitude of the fall of Tfing at the onset of 2nd running was on average 4.8, 5.1 and 3.4℃ for Control, HH cooling, and Leg cooling, respectively (p<0.05). The initial drop of Tfing at the onset of running was maintained for an average of 8.1, 7.9 and 6.3 minutes for Control, HH cooling, and Leg cooling, with no significant differences. In conclusion, the initial fall phenomena at the onset of treadmill exercise reflected non-thermal factors, as opposed to internal thermal status. The magnitude of the initial fall in Tfing was affected by legs cooling. Therefore, the initial fall phenomenon should be considered when interpreting the thermal status of the shell during heavy works/exercises that assigned with intermittent regional body cooling.

Characteristics of Size-segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings (대학건물 실내 에어로졸입자의 입경별 질량농도 특성)

  • Suh, Jeong-Min;Wang, Bin;Jang, Seong-Ho;Park, Jeong-Ho;Choi, Kum-Chan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.453-461
    • /
    • 2014
  • Objective: Based on the fact that fine particles are more likely to produce negative influences on the health of occupants as well as the quality of indoor air compared to coarse particles, it is critical to determine concentrations of aerosol particles with different sizes. Thus, this study focused on the size distribution and concentrations of aerosol particles in university buildings. Method: Aerosol particles in indoor air were collected from four areas: corridors in buildings(In-CO), lecture rooms(In-RO), laboratories(In-LR), and a cafeteria(In-RE). Samples were also collected from outside for comparison between the concentrations of indoor and outdoor particles. For the collection of the samples, an eight stage non-viable cascade impactor was used. Result: The average concentration of $PM_{10}$ in the samples collected from indoor areas was $34.65-91.08{\mu}g/m^3$,and the average for $PM_{2.5}$ was $22.65-60.40{\mu}g/m^3$. The concentrations of the aerosol particles in the corridors, lecture rooms, and laboratories were relatively higher than the concentrations collected from other areas. Furthermore, in terms of mass median aerodynamic diameter(MMAD), the corridors and lecture rooms had higher numbers due to their characteristics, showing $2.36{\mu}m$ and $2.11{\mu}m$, respectively. Laboratories running an electrolysis experiment showed $1.58{\mu}m$, and the cafeteria with regular maintenance and ventilation had $1.96{\mu}m$. Conclusion: The results showed that the $PM_{10}$ concentrations of all samples did not exceed indoor air quality standards. However, the $PM_{2.5}$ concentration was over the standard and, in particular, the concentration of fine particles collected from the laboratories was relatively higher, which could be an issue for the occupants. Therefore, it is important to improve the quality of the indoor air in university buildings.

Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains (도시철도 차량 하부의 풍속 및 미세먼지 농도 특징)

  • Kim, Jong Bum;Woo, Sang Hee;Jang, Hong-Ryang;Chou, Jin-Won;Hwang, Moon Se;Park, Hyung-Koo;Yoon, Hwa Hyeon;Jung, Joon-Sig;Bae, Gwi-Nam
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • Since operation of railway trains is a major source of particle pollution in tunnel air, a particle removal device can be an effective measure to remove wear particles. To obtain design conditions of the particle removal device that will be installed underneath the railway trains, the wind speed and particle concentration underneath the trains were investigated using a three-dimensional ultrasonic anemometer and a DustTrak aerosol monitor, respectively. The measurements were made for the trains running on Seoul Metropolitan Subway Line 5 on February 10, 2015. The data were analyzed according to the track geometry (straight, curved) and train speed pattern (acceleration, cruising, and deceleration) between stations. Train speed was also analyzed. The average wind speed and $PM_{10}$ concentration underneath the trains were ~30% of the train speed and ${\sim}200{\mu}g/m^3$ for both straight and curved sections. Average $PM_{10}$ concentration for deceleration sections was higher than that for acceleration sections.

A Study on Foodservice Facilities, Utilities, and Physical Environment in the Chonbuk Area of Korea (전북 지역 학교급식소의 시설.설비 및 물리적 환경에 대한 연구)

  • Kook, Sook-Ja;Choi, Byung-Sook;Rho, Jeong-Ok
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.4
    • /
    • pp.497-507
    • /
    • 2009
  • The principal objective of this study was to assess the situation of foodservice facilities, utilities, and physical environment in the Chonbuk area. Self-administered questionnaires were collected from 252 nutrition teachers and school dietitians. Statistical data analysis was completed using the SPSS v. 11.5 program. The results were summarized as follows: Approximately 99.2% of the subjects were women 76.6% were married, over 87% were between the ages of 30 and 40(p<0.01) and 56.8% had more than 11 years of experience(p<0.001). Among the 252 school foodservice systems evaluated, 51.6% of the schools were located in urban areas and 48.0% were in rural areas(p<0.01). Approximately 68.0% of the schools prepared meals in the conventional way, and 32.3% prepared them in the commissary way(p<0.001). The number of employees at each institution was separated into the following categories: 1 to 3(37.7%), 4 to 6(27.8%), and 7 to 9(25.4%, p<0.01). Approximately 54.0% of schools had been running a school meal service for longer than 11 years(p<0.001). However, 67.5% of those facilities had not been remodeled since the initial implementation of foodservices. Approximately 94.0% of the school foodservice facilities were located on the first floor. 72.2% among them were constructed of reinforced concrete and 16.7% were prefabricated(p<0.001). As the result of our evaluation of related physical evidence and the atmosphere of the space, the average importance grade was $4.41{\pm}0.46$, and the average performance grade was $2.78{\pm}0.67$. Most nutrition teachers and school dietitians in elementary, middle, & high schools responded that the related physical evidence and the atmosphere of the space in school foodservice facilities were important, but the satisfaction level among the nutrition teachers and school dietitians was quite low. Therefore, it's important and necessary to analyze the opinions of the stakeholders in the foodservice industry prior to the remodeling of school foodservice facilities and utilities.

A Study on the Firm Performances Regarding Technology and Employment of Government-financed SME R&D (정부지원 R&D의 중소기업 기술 및 고용 성과에 대한 연구)

  • Noh, Yong-Hwan;Hong, Sung Cheol
    • Journal of Technology Innovation
    • /
    • v.24 no.2
    • /
    • pp.57-89
    • /
    • 2016
  • This paper used individual establishment level data to estimate the effects of government support for the research and development of 'small and medium enterprises'(SMEs). We analyzed, on the establishment level, the degree of technical advancement, strength of private R&D incentives, and the effect on employment levels of firms which participated in the 2010 government R&D support project. The results of this study are as follows. First, the size and frequency of government investment in the R&D of SMEs were both positively correlated with the amount of patent registrations. Furthermore, we found that the amount of patent registrations were positively correlated with the size of the establishments, but the average level of technological advancement for the firms running the research was lower than the average level of technological advancement for the firms merely participating in the project. Second, the government's R&D policy was found to be complementary to private R&D incentives, and a 1% increase in government R&D investment resulted in an inelastic increase (0.193~0.245%) of the firms' post-program R&D spending. Third, we found that R&D support from the government contributed to an increase of employment by the participating firms. Additionally, we found that the impact of R&D support on job creation varied for the firm size and technological characteristics. Therefore, it is important for governments to take into consideration each type of small business, when setting R&D policies.

Development of a Community-Based Management System of Home-Stay Cancer Patients (지역사회 재가 암환자 관리 체계 구축 - 일 시 지역을 중심으로 -)

  • Kim, Boon-Han;Jung, Yun
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.2
    • /
    • pp.154-160
    • /
    • 2001
  • Purpose : This study, as the first year project of setting up a community based management system, was attempted for the cancer patients and their family to improve their quality of life; investigating and managing the cancer patients, educating volunteers and connecting the patients with the volunteers were performed. Method and result : The education of managing cancer patients for the volunteers was done once in lune for 2 days to the 80 volunteers. Questions about education effect, volunteer motivation and so on were made up. The survey showed, generally, education satisfaction level was high and a longer education and an intensive course were needed and was suggested that organizing a volunteer community be needed for the continuous further education and systematic management. As the result, after the public health center and volunteers deliberated, a volunteer community consisting of 4 teams, 28 members was organized, launched in Oct. and operated for the cancer patients and their family. For investigating and enrolling the patients, advertising on a local information paper, recommending of local doctors, publicizing by educating the heads of a subdivision of the city, the heads of a neighborhood association and the people in charge of the related local communities such as women's society, and surveying the community by volunteers were performed and the total, 41 patients were registered. Management of cancer patients was carried out by volunteers in a community and in a nursing school. A regional volunteers' community is composed of 23 members and they have worked 87 times, that is 3.8 times per capita on an average. The content of duties is attending the education (41.1%) the most. A volunteers' community of nursing students composed of 12 members have worked 135 times, that is 11.3 times per capita on an average. The content of duties - consulting with patients and home visiting (37.8 %) were the most and survey for investigating the cancer patients was the second. Conclusion : This study has the meaning that this is the guiding attempt in building a community based management system, and especially the achievement of this study is that a regional society organized a volunteer community for the cancer patients by itself and went into action for the cancer patients and their family. Furthermore, to activate this volunteering, it is necessary to keep managing volunteers and running continuing education or the intensive course of the volunteers. Indeed we should let the patients have good impression on this program through publicity and education for the residents to keep track of more cancer patients. For that, systematic and powerful cooperation of a self-administrative organization is required.

  • PDF

Assessment of the Potential Water Supply Rate of Agricultural Irrigation Facilities Using MODSIM - For Geum River Basin - (MODSIM을 이용한 농업용 수리시설의 용수공급율 평가 - 금강권역을 중심으로 -)

  • Ahn, So-Ra;Park, Geun-Ae;Shin, Young-Ho;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.10
    • /
    • pp.825-843
    • /
    • 2009
  • To prepare for agricultural droughts, the potential discharge to the water supply of irrigation facilities during drought periods is important. Using the MODSIM (Modified SIMYLD) model, water balance networks that consider irrigation facilities were designed for the Geum River Basin, and the potential discharge to the agricultural water supply of irrigation facilities were evaluated by running the model using data for 36 years (1967-2002). It was found that agricultural water deficiencies occurred during the drought years more than in the other years. The agricultural water deficiencies in 1994, 1995, and 2001, the representative drought years, were 745.8 million m$^3$, 661.1 million m$^3$, and 696.8 million m$^3$, respectively. The average potential discharge to the water supply of the sub-basin was 99.1 % in the cases of municipal and industrial water, and 84.4 % in the case of agricultural water. The potential discharge to the water supply in 1994, 1995, and 2001 were 74.8 %, 79.2 %, and 77.9 %, respectively, which are lower than those of the other years' sub-basin average. In the analysis of the contribution of each irrigation facility, the contributions of pumping stations and diversions were calculated as 32.5 %, and of culverts and wells, 4.0 %. During the drought periods, the pumping stations and diversions contributed to a certain level.

Temperature-Aware Microprocessor Design for Floating-Point Applications (부동소수점 응용을 위한 저온도 마이크로프로세서 설계)

  • Lee, Byeong-Seok;Kim, Cheol-Hong;Lee, Jeong-A
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.6
    • /
    • pp.532-542
    • /
    • 2009
  • Dynamic Thermal Management (DTM) technique is generally used for reducing the peak temperature (hotspot) in the microprocessors. Despite the advantages of lower cooling cost and improved stability, the DTM technique inevitably suffers from performance loss. This paper proposes the DualFloating-Point Adders Architecture to minimize the performance loss due to thermal problem when the floating-point applications are executed. During running floating-point applications, only one of two floating-point adders is used selectively in the proposed architecture, leading to reduced peak temperature in the processor. We also propose a new floorplan technique, which creates Space for Heat Transfer Delay in the processor for solving the thermal problem due to heat transfer between adjacent hot units. As a result, the peak temperature drops by $5.3^{\circ}C$ on the average (maximum $10.8^{\circ}C$ for the processor where the DTM is adopted, consequently giving a solution to the thermal problem. Moreover, the processor performance is improved by 41% on the average by reducing the stall time due to the DTM.