• Title/Summary/Keyword: rotational finger joint

Search Result 4, Processing Time 0.019 seconds

An Experiment of Structural Performance of Expansion Joint with Rotation Finger (가변형 핑거 조인트를 가지는 신축이음장치의 구조 성능 실험)

  • Yoo, Sung won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.170-175
    • /
    • 2018
  • For the seismic performance, it is necessary to prevent the destruction of the expansion joint device due to the appropriate deformation of the expansion joint device due to the seismic force. Recently, the hinge is installed on the fingering of the expansion joint device in Korea, New products are being developed. In this paper, we have experimentally evaluated the real scale resistance of the expansion joints with rotational finger joints against load at right angle to the bridge axis. Experimental results show that the maximum horizontal displacement is about 21.1mm for conventional stretch joints and 51.00mm for seismic stretch joints. It is presumed that the existing expansion joint test specimen is resistant to the load in a direction perpendicular to the throat axis, and then the bending and shear deformation of the finger are excessively generated and the fracture phenomenon is likely to occur. On the other hand, in the case of the seismic expansion joint, the deformation of the load due to the load is absorbed by the hinge of the finger with respect to the load in the direction perpendicular to the throat, so that only horizontal deformation in the direction of load action.

Recurrent Volar Rotatory Dislocation of the Proximal Interphalangeal Joint of the Finger in Judo Player - A Case Report - (유도 선수에서 발생한 수지 근위 지관절의 재발성 전방 회전 탈구 - 1례 보고 -)

  • Hwang, Jung-Chul;Chung, Duke-Whan;Han, Chung-Soo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.51-55
    • /
    • 2009
  • Volar rotatory dislocation of the proximal interphalangeal joint(PIP) of the finger is rare. We report a female judo player who had volar rotatory dislocation of the PIP joint of the middle finger. She had dislocation of PIP joint total 4 times. At operation, the central tendon was identified as being distension, with the ulnar collateral ligament ruptured. The ruptured ulnar collateral ligament was interposed within the joint. The ruptured ulnar collateral ligament was repaired and extensor expansion was repaired. At last follow-up, she didn't have recurrent dislocation during judo. Accurate diagnosis, early intervention and progressive rehabilitation of this injury are very important as other dislocations.

  • PDF

Research of Stable Grapsing in Field Robot (Field-Robot의 안정적 파지운동 제어에 관한 연구)

  • 박경택;심재군;한현용;양순용;이병룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.492-495
    • /
    • 1997
  • This paper aims to derive a mathematical model of the dynamics of handling task in field robot which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraints of tight area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of contact-area are discussed. Finally, it is shown that even in the simplest case of dual single D.O.F. manipulators there exists a sensory feedback from sensing data of he rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that he object is of rectangular shape and motion is confined to a horizontal

  • PDF

A Study on Stable Grasping Control of Dual-fingers with Soft-Tips (소프트-팁이 장착된 듀얼-핑거의 안정적 파지 제어에 관한 연구)

  • 심재군;한형용;양순용;이병룡;안경관;김성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.219-224
    • /
    • 2002
  • This paper aims to derive a mathematical model of the dynamics of handling tasks in robot finger which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of area-contact is discussed. Finally, it is shown that even in the simplest case of dual single D.O.F manipulators there exists a sensory feedback from sensing data of the rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that the object is of rectangular shape and motion is confined to a horizontal plane.

  • PDF